potentialpaper

PhysioSkeptic: Skeptical Reasoning Grounded in Signal Quality for Multimodal Rhythm Analysis

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 18:51 UTC · 5e4ba887c1c4 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "Ytw4pWrGGW"
- }
- ],
- "title": "PhysioSkeptic: Skeptical Reasoning Grounded in Signal Quality for Multimodal Rhythm Analysis",
- "authors": [],
- "abstract": "Large language models can reason over physiological summaries, but standard waveform-to-text interfaces often discard beat-level reliability, limiting performance under noise and cross-modal conflict. We introduce PhysioSkeptic for retrospective ECG–PPG rhythm classification. Its PhysioPatch encoder aligns waveform patches to cardiac landmarks and emits heartbeat-level tokens and a Patch Report containing rhythm cues, confidence estimates, and signal quality. This interface exposes beat-level quality as auditable evidence for conflict checks and quality-conditioned belief revision. On MIMIC-III-Ext-PPG, PhysioSkeptic reaches 0.886 Macro-F1, 6.2 percentage points above generic Debate and 4.1 points above an encoder-matched control; it has the lowest observed ECE among GPT-5.2 methods and reduces anchor-trap retention from 56.6% to 16.8%. Removing SQI anchoring produces the largest observed reduction among reasoning controls. In a zero-shot SQI proxy-transfer audit on MC-MED, learned SQI remains informative without retraining, while an auxiliary weak-label AF stress test improves AUROC from 0.913 to 0.934. A distilled Llama-1B student reaches 0.847 Macro-F1 with local inference. These results show that exposing beat-level signal quality can improve the auditability of multimodal rhythm reasoning under degraded measurements.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "1597dd96-b3d1-4766-93c6-c2e834feefd0"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "PhysioSkeptic: Skeptical Reasoning Grounded in Signal Quality for Multimodal Rhythm Analysis",
+ "authors": [],
+ "abstract": "Large language models can reason over physiological summaries, but standard waveform-to-text interfaces often discard beat-level reliability, limiting performance under noise and cross-modal conflict. We introduce PhysioSkeptic for retrospective ECG–PPG rhythm classification. Its PhysioPatch encoder aligns waveform patches to cardiac landmarks and emits heartbeat-level tokens and a Patch Report containing rhythm cues, confidence estimates, and signal quality. This interface exposes beat-level quality as auditable evidence for conflict checks and quality-conditioned belief revision. On MIMIC-III-Ext-PPG, PhysioSkeptic reaches 0.886 Macro-F1, 6.2 percentage points above generic Debate and 4.1 points above an encoder-matched control; it has the lowest observed ECE among GPT-5.2 methods and reduces anchor-trap retention from 56.6% to 16.8%. Removing SQI anchoring produces the largest observed reduction among reasoning controls. In a zero-shot SQI proxy-transfer audit on MC-MED, learned SQI remains informative without retraining, while an auxiliary weak-label AF stress test improves AUROC from 0.913 to 0.934. A distilled Llama-1B student reaches 0.847 Macro-F1 with local inference. These results show that exposing beat-level signal quality can improve the auditability of multimodal rhythm reasoning under degraded measurements.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}