potentialpaper

Trajectory-Consistent Calibration for Cache-Accelerated Diffusion Models

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 18:52 UTC · fd13629d6be1 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "CIIEG8BPo5"
- }
- ],
- "title": "Trajectory-Consistent Calibration for Cache-Accelerated Diffusion Models",
- "authors": [],
- "abstract": "Diffusion Transformers require repeated denoiser evaluations during iterative sampling, making inference computationally expensive. Cache-based acceleration reduces this cost by reusing intermediate representations across denoising steps, but the resulting cache-side features can deviate from those produced by fresh computation and degrade generation quality. We identify two coupled calibration challenges. First, a reused or approximately computed feature can differ from its full-computation counterpart at the current calibration site. Second, applying an earlier correction changes the subsequent cache-side trajectory, so a later calibration operator may encounter a feature distribution different from the one used to fit it. We refer to these challenges as direct cache mismatch and trajectory-induced calibration mismatch, respectively. To address them, we propose Trajectory-Consistent Calibration (TCC), which fits closed-form, site-specific calibration operators from paired cache-side and full-computation features without modifying the denoiser parameters or the base cache strategy. Rather than fitting all operators on a single uncorrected cache trajectory, TCC processes selected denoising timesteps sequentially: it probes cache-side features, fits the corresponding operators, and replays and commits the calibrated step before estimating any later operators. Experiments on PixArt-α and DiT-XL/2 report lower FID values across the evaluated cache-based acceleration settings. In a representative PixArt-α setting based on FORA, TCC reduces FID from 29.83 to 27.35, slightly surpassing the corresponding full-computation baseline in terms of FID.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "d49ad26d-77c6-4f60-b8ea-a3b64ec38cec"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "Trajectory-Consistent Calibration for Cache-Accelerated Diffusion Models",
+ "authors": [],
+ "abstract": "Diffusion Transformers require repeated denoiser evaluations during iterative sampling, making inference computationally expensive. Cache-based acceleration reduces this cost by reusing intermediate representations across denoising steps, but the resulting cache-side features can deviate from those produced by fresh computation and degrade generation quality. We identify two coupled calibration challenges. First, a reused or approximately computed feature can differ from its full-computation counterpart at the current calibration site. Second, applying an earlier correction changes the subsequent cache-side trajectory, so a later calibration operator may encounter a feature distribution different from the one used to fit it. We refer to these challenges as direct cache mismatch and trajectory-induced calibration mismatch, respectively. To address them, we propose Trajectory-Consistent Calibration (TCC), which fits closed-form, site-specific calibration operators from paired cache-side and full-computation features without modifying the denoiser parameters or the base cache strategy. Rather than fitting all operators on a single uncorrected cache trajectory, TCC processes selected denoising timesteps sequentially: it probes cache-side features, fits the corresponding operators, and replays and commits the calibrated step before estimating any later operators. Experiments on PixArt-α and DiT-XL/2 report lower FID values across the evaluated cache-based acceleration settings. In a representative PixArt-α setting based on FORA, TCC reduces FID from 29.83 to 27.35, slightly surpassing the corresponding full-computation baseline in terms of FID.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}