Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 18:53 UTC · a8655c9cec59 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "FgiqVjHFe3"- }- ],- "title": "FlowSeed: Continuous-Time Contrast-Enhanced CT Synthesis via Organ-Aware Gaussian-Weighted Residual Splatting",- "authors": [],- "abstract": "Multiphase contrast-enhanced computed tomography (CECT) sparsely samples a continuous, organ-dependent enhancement process. However, existing synthesis methods treat arterial, venous, and delayed scans as discrete targets and reconstruct anatomy already available in non-contrast CT (NCCT). We introduce FlowSeed, a continuous-time residual contrast-rendering framework that retains NCCT as the anatomical base and renders only its time-dependent enhancement. FlowSeed uses soft organ maps to route time-conditioned affine modulation at each voxel. A slice-aware Gaussian residual decoder then predicts intensity, opacity, axis-aligned scale, and center offset to render enhancement onto queried axial slices. Physiology-inspired ordinal constraints regularize liver and aortic enhancement, while a conditional PatchGAN provides adversarial supervision for local appearance fidelity. On held-out MCT-LTDiag studies, FlowSeed reduces mean absolute error by 6.7--18.8\\% relative to the strongest comparator across three anatomical groups. On external WAW-TACE data, it achieves the lowest mean absolute error and highest SSIM in all groups. Ablations support the contributions of organ-aware temporal routing and Gaussian-weighted residual decoding. Dense-query visualizations further show that FlowSeed can synthesize continuous enhancement sequences with distinct organ-dependent responses across time.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "f9d0fc33-f9d7-42f3-bf69-d7ce6da2dff2"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "FlowSeed: Continuous-Time Contrast-Enhanced CT Synthesis via Organ-Aware Gaussian-Weighted Residual Splatting",+ "authors": [],+ "abstract": "Multiphase contrast-enhanced computed tomography (CECT) sparsely samples a continuous, organ-dependent enhancement process. However, existing synthesis methods treat arterial, venous, and delayed scans as discrete targets and reconstruct anatomy already available in non-contrast CT (NCCT). We introduce FlowSeed, a continuous-time residual contrast-rendering framework that retains NCCT as the anatomical base and renders only its time-dependent enhancement. FlowSeed uses soft organ maps to route time-conditioned affine modulation at each voxel. A slice-aware Gaussian residual decoder then predicts intensity, opacity, axis-aligned scale, and center offset to render enhancement onto queried axial slices. Physiology-inspired ordinal constraints regularize liver and aortic enhancement, while a conditional PatchGAN provides adversarial supervision for local appearance fidelity. On held-out MCT-LTDiag studies, FlowSeed reduces mean absolute error by 6.7--18.8\\% relative to the strongest comparator across three anatomical groups. On external WAW-TACE data, it achieves the lowest mean absolute error and highest SSIM in all groups. Ablations support the contributions of organ-aware temporal routing and Gaussian-weighted residual decoding. Dense-query visualizations further show that FlowSeed can synthesize continuous enhancement sequences with distinct organ-dependent responses across time.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}