potentialpaper

Nef-Net v2: Adapting Electrocardio Panorama in the wild

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 18:43 UTC · 202042cbeb34 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,26 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "JzZhhhxniR"
- }
- ],
- "title": "Nef-Net v2: Adapting Electrocardio Panorama in the wild",
- "authors": [
- "Zehui Zhan",
- "Yaojun Hu",
- "Jiajing Zhang",
- "Wanchen Lian",
- "Wanqing Wu",
- "Jintai Chen"
- ],
- "abstract": "Conventional multi-lead electrocardiogram (ECG) systems capture cardiac signals\nfrom a fixed set of anatomical viewpoints defined by lead placement. However, cer-\ntain cardiac conditions (e.g., Brugada syndrome) require additional, non-standard\nviewpoints to reveal diagnostically critical patterns that may be absent in standard\nleads. To systematically overcome this limitation, Nef-Net was recently introduced\nto reconstruct a continuous electrocardiac field, enabling virtual observation of\nECG signals from arbitrary views (termed Electrocardio Panorama). Despite\nits promise, Nef-Net operates under idealized assumptions and faces in-the-wild\nchallenges, such as long-duration ECG modeling, robustness to device-specific\nsignal artifacts, and suboptimal lead placement calibration. This paper presents\nNEF-NET V2, an enhanced framework for realistic panoramic ECG synthesis that\nsupports arbitrary-length signal synthesis from any desired view, generalizes across\nECG devices, and compensates for operator-induced deviations in electrode place-\nment. These capabilities are enabled by a newly designed model architecture that\nperforms direct view transformation, incorporating a workflow comprising offline\npretraining, device calibration tuning steps as well as an on-the-fly calibration step\nfor patient-specific adaptation. To rigorously evaluate panoramic ECG synthe-\nsis, we construct a new Electrocardio Panorama benchmark, called Panobench,\ncomprising 4470 recordings with 48 views per subject, capturing the full spatial\nvariability of cardiac electrical activity. Experimental results show that NEF-NET\nV2 delivers substantial improvements over Nef-Net, yielding an increase of around\n6 dB in PSNR in real-world settings. Our data and code are publicly available at\nhttps://github.com/HKUSTGZ-ML4Health-Lab/NEFNET-v2.",
- "year": 2026,
- "venue": "ICLR 2026",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "9aae1ba1-9804-48f9-9677-77f8ddcd41c5"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,16 @@
+{
+ "title": "Nef-Net v2: Adapting Electrocardio Panorama in the wild",
+ "authors": [
+ "Zehui Zhan",
+ "Yaojun Hu",
+ "Jiajing Zhang",
+ "Wanchen Lian",
+ "Wanqing Wu",
+ "Jintai Chen"
+ ],
+ "abstract": "Conventional multi-lead electrocardiogram (ECG) systems capture cardiac signals\nfrom a fixed set of anatomical viewpoints defined by lead placement. However, cer-\ntain cardiac conditions (e.g., Brugada syndrome) require additional, non-standard\nviewpoints to reveal diagnostically critical patterns that may be absent in standard\nleads. To systematically overcome this limitation, Nef-Net was recently introduced\nto reconstruct a continuous electrocardiac field, enabling virtual observation of\nECG signals from arbitrary views (termed Electrocardio Panorama). Despite\nits promise, Nef-Net operates under idealized assumptions and faces in-the-wild\nchallenges, such as long-duration ECG modeling, robustness to device-specific\nsignal artifacts, and suboptimal lead placement calibration. This paper presents\nNEF-NET V2, an enhanced framework for realistic panoramic ECG synthesis that\nsupports arbitrary-length signal synthesis from any desired view, generalizes across\nECG devices, and compensates for operator-induced deviations in electrode place-\nment. These capabilities are enabled by a newly designed model architecture that\nperforms direct view transformation, incorporating a workflow comprising offline\npretraining, device calibration tuning steps as well as an on-the-fly calibration step\nfor patient-specific adaptation. To rigorously evaluate panoramic ECG synthe-\nsis, we construct a new Electrocardio Panorama benchmark, called Panobench,\ncomprising 4470 recordings with 48 views per subject, capturing the full spatial\nvariability of cardiac electrical activity. Experimental results show that NEF-NET\nV2 delivers substantial improvements over Nef-Net, yielding an increase of around\n6 dB in PSNR in real-world settings. Our data and code are publicly available at\nhttps://github.com/HKUSTGZ-ML4Health-Lab/NEFNET-v2.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}