Fair Protocol Reveals Collapse of Medical Hallucination Detectors-and Two Detectors That Survive It
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:52 UTC · f6af1fb065f4 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "zeryzsUbdR"- }- ],- "title": "Fair Protocol Reveals Collapse of Medical Hallucination Detectors-and Two Detectors That Survive It",- "authors": [],- "abstract": "State-of-the-art hallucination detectors for medical VQA fail to reliably measure whether answers are grounded in the image. We show that reported progress is largely an artifact of benchmark leakage: detectors exploit surface statistics like answer length, formatting, and sampling dispersion that correlate with hallucination only within the benchmarks used for tuning. We introduce a fair evaluation protocol that strips away these shortcuts via length- and type-matched negatives, image-level splits, and language-leakage controls. Under this protocol, all prior methods collapse to near-chance performance. VASE, SE, RadFlag, and a frozen LMM all score an AUROC of 0.47--0.57 across three benchmarks. A plain trainable MLP reaches 0.70--0.97, so model capacity is not the bottleneck; an input ablation shows that the residual signal comes from question-answer statistics, not image grounding. We then ask what survives. QCE-Net, an interpretable detector that pools image patches with both question and answer as attention queries, matches or exceeds the MLP baseline, recovering the grounding signal that frozen encoders can provide. LLaVA-LoRA, which fine-tunes the medical LMM with LoRA to emit per-sample grounding judgments, goes further: it reaches 0.885 AUROC on VQA-RAD, the first detector under a leakage-free protocol to clear the clinical bar of 0.8 that no frozen-CLIP method reaches.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "71a78e81-8fb9-45bc-b590-3a8dbfb8f3aa"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "Fair Protocol Reveals Collapse of Medical Hallucination Detectors-and Two Detectors That Survive It",+ "authors": [],+ "abstract": "State-of-the-art hallucination detectors for medical VQA fail to reliably measure whether answers are grounded in the image. We show that reported progress is largely an artifact of benchmark leakage: detectors exploit surface statistics like answer length, formatting, and sampling dispersion that correlate with hallucination only within the benchmarks used for tuning. We introduce a fair evaluation protocol that strips away these shortcuts via length- and type-matched negatives, image-level splits, and language-leakage controls. Under this protocol, all prior methods collapse to near-chance performance. VASE, SE, RadFlag, and a frozen LMM all score an AUROC of 0.47--0.57 across three benchmarks. A plain trainable MLP reaches 0.70--0.97, so model capacity is not the bottleneck; an input ablation shows that the residual signal comes from question-answer statistics, not image grounding. We then ask what survives. QCE-Net, an interpretable detector that pools image patches with both question and answer as attention queries, matches or exceeds the MLP baseline, recovering the grounding signal that frozen encoders can provide. LLaVA-LoRA, which fine-tunes the medical LMM with LoRA to emit per-sample grounding judgments, goes further: it reaches 0.885 AUROC on VQA-RAD, the first detector under a leakage-free protocol to clear the clinical bar of 0.8 that no frozen-CLIP method reaches.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}