potentialpaper

Learning the specimen structure in single-molecule localization microscopy

Update ICLR 2027 submission Radj1Kb5YH: 1 note

@openreview[bot] · 2026-11-26 13:45 UTC · 56eb7b3d248c ·

Evidence

reviews/openreview/radj1kb5yh/notes/v0a0kaux7v.json modified

+++ b/reviews/openreview/radj1kb5yh/notes/v0a0kaux7v.json
@@ -13,12 +13,19 @@
"critical_strengths": "1. Acquisition-wide adaptation is useful and empirically supported. Under external calibration, Ours-structure improves high-SNR lateral/axial RMSE from 29.0/33.4 to 22.5/19.3 nm and E3D from 0.725 to 0.796 relative to Ours-fixed (Table 1). At low SNR, RMSE also improves, although Jaccard does not. This is meaningful evidence for the combined spatial/count adaptation.\n2. The unified acquisition-specific framework learns several nuisance quantities and provides a continuous representation. The paper compares four relevant baselines under two calibration regimes and acknowledges mixed real-data metrics and feedback-loop limitations. This makes the application contribution credible and potentially useful.",
"critical_weaknesses": "1. Independent validation of the learned structure is incomplete. Table 2 evaluates localization point clouds, whereas Figure 3 shows the learned density against baseline point clouds. Smoother images therefore do not establish better structural fidelity. Appendix F.2 splits localizations for FRC, but does not establish that model fitting is independent across halves; a shared acquisition-trained prior could induce correlated errors. RSP uses a low-resolution temporal-SD reference, which cannot validate nanoscale geometry.\n2. The source and reliability of adaptation gains remain insufficiently isolated. Ours-structure learns both spatial density and emitter count. Full acquisition-only experiments further change photophysics, PSF, and background. Appendix A's variational PSF target and its proposal-corrected marginal-evidence target are distinct, and Eq. (40) introduces a further proposal approximation. Their practical effects are not quantified. These gaps limit confidence in the central mechanism.",
"questions_for_authors": "1. Clarification/validation: Were FRC halves processed with independently trained spatial densities and calibration models? Please clarify shared training and, if shared, report independent-half training with comparable data budgets.\n2. Validation: Can the learned density itself be quantitatively evaluated on synthetic ground truth, with matched rendering or post-processing for baselines? Please assess both recovery of true fine structures and suppression of false structures.\n3. Attribution: Please separate spatial-only and count-only adaptation under external calibration, and quantify calibration-component effects in the full method. How sensitive are results to the mixture cap and uncertainty-dependent density gate?\n4. Theory/implementation: Under what conditions does replacing pi_theta in Eq. (13) by pi_eta in Eq. (21) preserve the intended optimization? How does replacing the mixture proposal by stop-gradient q_psi in Eq. (40) affect calibration or stability? Please also specify axial scaling used for reported nm errors and per-acquisition compute cost.",
"flag_for_ethics_review": "No",
- "rating": 2,
+ "rating": 3,
"confidence": 3
},
"createdAt": "2026-10-22T11:58:35.040Z",
- "modifiedAt": "2026-11-18T19:55:34.668Z",
+ "modifiedAt": "2026-11-26T13:01:36.166Z",
"url": "https://openreview.net/forum?id=Radj1Kb5YH&noteId=v0A0KAux7V",
- "license": "CC-BY-4.0"
+ "license": "CC-BY-4.0",
+ "scoreChanges": [
+ {
+ "field": "rating",
+ "from": 2,
+ "at": "2026-11-26T13:45:48.319Z"
+ }
+ ]
}