potentialpaper

Code, Not Chains-of-Thought: Localizing Guideline-Adherence Risk by Compiling Guidelines into MedCode

Import ICLR 2027 submission K3JiuXy43u: 4 notes

@openreview[bot] · 2026-11-22 21:06 UTC · 28bade5c90a0 ·

Evidence

reviews/openreview/k3jiuxy43u/forms.json added

+++ b/reviews/openreview/k3jiuxy43u/forms.json
@@ -0,0 +1,183 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "additional_comments_on_reviewer_discussion",
+ "label": "Reviewer discussion",
+ "type": "text"
+ },
+ {
+ "key": "recommendation",
+ "label": "Recommendation",
+ "type": "choice"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "soundness",
+ "presentation",
+ "informativeness"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "soundness",
+ "label": "Soundness",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "presentation",
+ "label": "Presentation",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "informativeness",
+ "label": "Informativeness",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "paper_summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "critical_strengths",
+ "label": "Strengths",
+ "type": "text"
+ },
+ {
+ "key": "critical_weaknesses",
+ "label": "Weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions_for_authors",
+ "label": "Questions for the authors",
+ "type": "text"
+ },
+ {
+ "key": "flag_for_ethics_review",
+ "label": "Flag for ethics review",
+ "type": "choice",
+ "omitWhen": [
+ "No",
+ "No ethics review needed."
+ ]
+ },
+ {
+ "key": "details_of_ethics_concerns",
+ "label": "Ethics concerns",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/k3jiuxy43u/notes/598gviwnyf.json added

+++ b/reviews/openreview/k3jiuxy43u/notes/598gviwnyf.json
@@ -0,0 +1,25 @@
+{
+ "schema": "review/1",
+ "id": "598gViWnYF",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer ayGB",
+ "content": {
+ "paper_summary": "This paper tries to address unsupported recommendations from clinical LLMs, which the authors attribute partly to the same model both interpreting the evidence and emitting the clinical action. They propose MedCode, which compiles NCCN guidelines into citation-bound Python rules, restricts the LLM to extracting a typed patient state, and lets a rule engine select an action from a closed set, abstaining when evidence is missing. The evaluation covers TNM staging on LungCURE and an in-house esophageal cohort, treatment-plan coverage on a 202-case lung subset scored by an LLM judge, and the distillation of a 27B teacher into a 4B student with SFT and GRPO using a rule-engine reward. The authors report large staging gains for several open-weight models and coverage gains for all evaluated models.",
+ "presentation": 1,
+ "informativeness": 1,
+ "soundness": 1,
+ "critical_strengths": "I think the direction is reasonable. Keeping the reading of the record apart from the application of the guideline, and making the latter deterministic and tied to a verbatim citation, is a sensible route towards clinical recommendations that can be audited. The authors are also candid about what their gates do not certify and about the limits of their coverage metric.",
+ "critical_weaknesses": "My main concern is that the contribution amounts to prompt engineering combined with hand-written rules, and that it is not evaluated against the alternatives that matter. The paper itself describes the design as restricting the LLM to structured extraction, with the decision left to the rule engine. Executable guideline representations have a long history, which the paper acknowledges, and the only learning component, the distillation, draws almost all of its gain from supervised fine-tuning on extractions, while the rule-based GRPO step that the paper calls decisive adds about one point (Table 6). At the same time, the comparison is thin: there is a single prompting condition whose prompt and guideline text are not specified, no other prompting strategy such as chain-of-thought, few-shot examples or code generation is tried, and none of the guideline-grounded systems discussed in the paper is actually run.\n\nI am also not persuaded by the results that are reported. The method does not help a frontier model: for GPT-5.5 it is level with guideline prompting on lung staging and clearly worse on esophageal staging (75.90 vs. 68.27), and the paper's own ablation attributes the drop to restricting the model to typed extraction (Tables 3-4). The large gains in the abstract are measured against a no-guideline baseline and become much smaller against guideline prompting, and the treatment comparison uses a coverage-only metric judged by an LLM, on cases selected to be guideline-conformant, which does not penalize extraneous or harmful recommendations. More fundamentally, the properties the paper is built around, namely auditability, localized updates, abstention and consistent answers, are not measured. Runnable rules exist only for NSCLC, although the paper provides catalog scaffolds for 68 guidelines and evaluates esophageal staging, and it reports nothing about the number of rules or the effort of writing and maintaining them. When a new therapy enters a guideline, new rules, tests and citations would have to be written and verified by clinicians, and this authoring and maintenance burden, long the main obstacle for computable guidelines, is not addressed.\n\nBeyond these points, the reporting needs substantial work. Several numbers cannot be traced to any table, statements in the text disagree with the tables, the paper contradicts itself on its data sources and on how the GRPO reward is computed, important results are deferred to a supplement that is not part of the paper, and variance and statistical tests are largely missing.",
+ "questions_for_authors": "How does MedCode compare with other prompting strategies (chain-of-thought, few-shot, code generation and execution) and with an existing guideline-grounded system on the same data?\n\nWhy does MedCode reduce GPT-5.5's accuracy, and what does it offer a strong model?\n\nHow many rules are there, which of them implement esophageal staging, and is there any evidence for the update and abstention claims?",
+ "flag_for_ethics_review": "Yes",
+ "details_of_ethics_concerns": "Research integrity. Several references could not be verified as cited. I have sent the details to the AC in a confidential comment.",
+ "rating": 1,
+ "confidence": 4
+ },
+ "createdAt": "2026-11-03T01:11:49.042Z",
+ "modifiedAt": "2026-11-06T12:16:28.965Z",
+ "url": "https://openreview.net/forum?id=K3JiuXy43u&noteId=598gViWnYF",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/k3jiuxy43u/notes/laruqm7i79.json added

+++ b/reviews/openreview/k3jiuxy43u/notes/laruqm7i79.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "LARuQM7I79",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer wWKK",
+ "content": {
+ "paper_summary": "The main idea of the paper is to use EMR data to automatically fill out a document for the patient process it through a guideline constructing Python executable versions using LLMs.",
+ "presentation": 1,
+ "informativeness": 1,
+ "soundness": 1,
+ "critical_strengths": "The paper addresses a timely problem.",
+ "critical_weaknesses": "**Major Issues**\n\n1. The main contribution of the paper is to limit the LLMs output to machine readable format for EMR data; constructing Python executable decision graphs which then are checked by some predetermined steps. Training the smaller model and showing similar performance doesn't really have novelty as they are already widely known. I don't think the paper is novel enough for ICLR.\n2. The figure doesn't match up to ICLR standards.\n3. The manuscript reads more like a report rather then a scientific paper.\n4. The evaluation is being done by another LLM without any human validation\n5. The accuracy of the generated graphs are not evaluated. \n6. The accuracy of the generated EMR's are not reported.\n\n**Minor Issues**\n\n1. The code type font on ``ClinicalAction'' should be removed.\n2. The usage of the word ``diff'' is informal.\n3. The third contribution is not mentioned at all in the abstract.\n4. The table presented should be self sufficient whereas the code type fonts makes it harder and the caption doesn't provide enough information.\n5. Phrases such as ``What is covered in this submission'' should be removed.",
+ "questions_for_authors": "1. How accurate is the LLM at filling in the patient record on its own?\n2. How accurate is the LLM at writing rules from the guidelines?\n3. Did you check that the GPT-5.4 judge agrees with human doctors?",
+ "flag_for_ethics_review": "No",
+ "rating": 1,
+ "confidence": 4
+ },
+ "createdAt": "2026-10-05T01:43:34.060Z",
+ "modifiedAt": "2026-11-06T12:16:33.577Z",
+ "url": "https://openreview.net/forum?id=K3JiuXy43u&noteId=LARuQM7I79",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/k3jiuxy43u/notes/u2mixanv5r.json added

+++ b/reviews/openreview/k3jiuxy43u/notes/u2mixanv5r.json
@@ -0,0 +1,25 @@
+{
+ "schema": "review/1",
+ "id": "U2mIXaNV5R",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer pWcq",
+ "content": {
+ "paper_summary": "This paper proposes MEDCODE, which restricts the LLM to structured patient-state extraction while deterministic, citation-bound Python rules map the extracted state to a closed set of clinical actions, with explicit abstention and six static compliance gates. It is evaluated on TNM staging (LungCURE-EN, EsophagusPKUCH) and treatment-plan coverage (a 202-case LungFAHGMU subset), with large gains for smaller open-weight models but not for frontier models. The rule engine is also used as a GRPO reward to post-train a Qwen3.5-4B student (MEDCODE-LM).",
+ "presentation": 1,
+ "informativeness": 2,
+ "soundness": 2,
+ "critical_strengths": "1. **The evaluation uses real clinical datasets and popular model families**. The experiments are conducted on real-world patient records and cover multiple widely used models, including GPT-5.5, DeepSeek-V4-Pro, Qwen3.6, and Gemma-4. The paper reports substantial gains for smaller and open-weight models, and candidly acknowledges that frontier models do not benefit and can even slightly degrade.",
+ "critical_weaknesses": "1. **The novelty is limited**. The core mechanism where an LLM extracts typed variables and deterministic code executes clinical rules already exists in the similar benchmarks. LungCURE's LCAgent extracts T, N, and M evidence separately and aggregates them with a deterministic rule-based node. CDR-Agent extracts variables from clinical notes and executes Python clinical-decision-rule scripts. However, neither method is included as a baseline.\n2. **The effective scope of the method is limited, and its results are difficult to reproduce**. On TNM staging, the gains are concentrated on smaller open-weight models, while the stronger models (GPT-5.5 and Qwen3.5-397B) show no improvement or even a decline. The authors attribute this to frontier models having \"memorized the staging thresholds,\" but this explanation would predict no change rather than a decline, so the drop remains unexplained. In addition, two of the three datasets (LungFAHGMU and EsophagusPKUCH) appear to be private in-house cohorts, and all treatment results rely entirely on private data, which makes the main findings difficult to reproduce.",
+ "questions_for_authors": "1. Can the authors compare against LCAgent on LungCURE TNM staging and against a simple baseline of structured extraction plus a standard AJCC staging calculator (or a PAL-style code baseline), to show what MEDCODE contributes beyond deterministic aggregation of extracted fields?\n2. Can the authors substantially revise the manuscript’s organization and exposition? Despite having some familiarity with medical LLMs, I found the paper difficult to follow for reasons beyond domain knowledge: clinical terminology, software contracts, evaluation settings, and training claims are introduced together without sufficient separation or definition. Given ICLR’s broad readership, the paper should clearly separate the clinical background and assumptions from the technical contributions, define terms such as TNM and NCCN at first use, and distinguish the 68-guideline scaffold from the actually authored executable rules, the runtime MEDCODE system, and MEDCODE-LM training.",
+ "flag_for_ethics_review": "Yes",
+ "details_of_ethics_concerns": "**Research integrity: inaccurate or unverifiable references**\n\nI verified some examples against public records below:\n1. **CancerGUIDE (Yang et al., 2025)**. The listed title and authors do not match the public paper, and the cited arXiv identifier, 2508.04114, resolves to an unrelated applied-physics paper on terahertz communications. The public CancerGUIDE paper is CancerGUIDE: Cancer Guideline Understanding via Internal Disagreement Estimation by Unell et al. (arXiv:2509.07325).\n2. **Staniek et al. (2025)**. I could not locate the cited survey, Computable Clinical Guidelines: A Survey. The cited arXiv identifier, 2503.07291, resolves to an unrelated materials-science paper.\n3. **MedKP (cited as Wang et al., 2024a)**. The paper lists this work with a title, authors, and venue (NAACL 2024) that do not match the actual MedKP paper, which is \"MedKP: Medical Dialogue with Knowledge Enhancement and Clinical Pathway Encoding\" by Wu et al. (arXiv:2403.06611).\n4. **CDR-Agent (Chen et al., 2025)**. The cited title, authors, and venue (JAMIA) do not match the actual paper by Xiang et al. (arXiv:2505.23055, AMIA 2025), and its description as guideline-graph reasoning does not reflect its content, which extracts variables from clinical notes and executes Python clinical-decision-rule scripts.\n\nI recommend that the AC should verify the bibliography carefully.",
+ "rating": 1,
+ "confidence": 2
+ },
+ "createdAt": "2026-10-30T15:47:53.181Z",
+ "modifiedAt": "2026-11-06T12:16:30.932Z",
+ "url": "https://openreview.net/forum?id=K3JiuXy43u&noteId=U2mIXaNV5R",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/k3jiuxy43u/notes/xs1lpljmak.json added

+++ b/reviews/openreview/k3jiuxy43u/notes/xs1lpljmak.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "Xs1lpLjmaK",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer QTW8",
+ "content": {
+ "paper_summary": "MedCode compiles oncology guidelines into executable Python rules and restricts LLMs to structured patient-information extraction. The paper evaluates cancer staging and treatment-plan coverage and uses the rules to train a smaller model.",
+ "presentation": 2,
+ "informativeness": 1,
+ "soundness": 1,
+ "critical_strengths": "1. The paper addresses an important problem: making guideline-based recommendations easier to inspect and trace to their sources.\n\n2. The staging gains for several smaller models suggest practical value for tasks with clear rules and sufficient coverage.",
+ "critical_weaknesses": "1. It is unclear whether the added control is worth the loss of flexibility and rule-maintenance costs. Missing context and extraction errors can still lead to wrong decisions. These trade-offs need evaluation in cases with exceptions or conflicting evidence.\n\n2. The training contribution is not clearly distinguished from MedGuideX [1], which already uses executable guidelines to generate training data and rewards. The paper should explain what its training method adds.\n\n3. A key missing baseline is an LLM that can use the same rule tools, revisit the record, and explicitly abstain. The current comparison does not show why the LLM must be removed from decision-making.\n\n4. The ablation should separate extraction quality from execution, keeping the rules fixed and using both model-extracted and clinician-checked patient states. The performance drop for GPT-5.5 also needs error analysis. Saying that strong models have memorized the rules does not explain this loss.\n\n[1] Shen, Y., Cao, L., Du, S., Wang, Y., Zhou, J., Peng, H., & Guo, Y. (2026). MedGuideX: Internalizing Decision Logic from Executable Guidelines into Large Language Models for Clinical Reasoning. arXiv preprint arXiv:2605.26567.",
+ "questions_for_authors": "Please refer to the weaknesses above.",
+ "flag_for_ethics_review": "No",
+ "rating": 1,
+ "confidence": 2
+ },
+ "createdAt": "2026-10-18T23:01:43.465Z",
+ "modifiedAt": "2026-11-06T12:16:32.407Z",
+ "url": "https://openreview.net/forum?id=K3JiuXy43u&noteId=Xs1lpLjmaK",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/k3jiuxy43u/submission.json added

+++ b/reviews/openreview/k3jiuxy43u/submission.json
@@ -0,0 +1,18 @@
+{
+ "schema": "submission/1",
+ "id": "K3JiuXy43u",
+ "venue": {
+ "id": "ICLR.cc/2027/Conference",
+ "name": "ICLR 2027",
+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference"
+ },
+ "number": 7323,
+ "keywords": [
+ "executable clinical guidelines",
+ "rule-based verification",
+ "oncology treatment recommendation",
+ "verifiable reinforcement learning"
+ ],
+ "url": "https://openreview.net/forum?id=K3JiuXy43u",
+ "license": "CC-BY-4.0"
+}

versions/v_7v7b64wr.json modified

+++ b/versions/v_7v7b64wr.json
@@ -1,7 +1,20 @@
{
+ "date": "2026-09-01",
"kind": "submitted",
"label": "ICLR 2027 (under review)",
+ "submissions": [
+ {
+ "venue": "ICLR 2027",
+ "status": "under_review",
+ "number": 7323,
+ "url": "https://openreview.net/forum?id=K3JiuXy43u",
+ "reviews": "openreview/k3jiuxy43u",
+ "evidence": [
+ "https://openreview.net/forum?id=K3JiuXy43u"
+ ]
+ }
+ ],
"url": "https://openreview.net/forum?id=K3JiuXy43u",
"pdf": {
"source": "https://openreview.net/forum?id=K3JiuXy43u",
"license": "CC-BY-4.0"