MedVision-X: Unifying Medical Image Analysis and Synthesis through Generative Modeling
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 19:03 UTC · 71416a227461 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "WztUti733r"- }- ],- "title": "MedVision-X: Unifying Medical Image Analysis and Synthesis through Generative Modeling",- "authors": [],- "abstract": "Medical image analysis and synthesis are served by separate specialist models:\nsegmentation networks predict label maps, restoration networks recover\nintensities, and translation or editing networks synthesize new images, each\nwith its own architecture, objective, and output head. We ask how far a single\ngenerative model with one image output pathway can go across these\nheterogeneous tasks. We present \\model{}, which casts segmentation,\nsuper-resolution, cross-modal translation, virtual immunohistochemical staining,\nCT denoising, and lesion editing as instruction-conditioned image generation.\nMasks are rendered as color-coded images with an optional text legend and\ncontinuous targets are generated directly, so every task is trained with the\nsame flow-matching objective and decoded by the same image decoder, without\ntask-specific heads or losses. Starting from the SenseNova-Vision unified\nmultimodal model, \\model{} is adapted in two stages: broad adaptation on 1.04M\nmedical records, followed by balanced joint training on the training folds of\n16 benchmarks. Across 14 test benchmarks and 62 scored baseline entries,\n\\model{} obtains the best primary endpoint on 8 and ranks second on 2 more. The\ngains are largest for physically meaningful targets: one checkpoint reduces\nbody HU MAE from 99.0 to 39.1 on low-dose CT and from 83.1 to 55.2 on MRI-to-CT\nsynthesis, and improves PSNR by 4.0\\,dB on LoDoPaB-CT and 3.2\\,dB on IXI.\nDataset-specific segmentation checkpoints lead on BUSI and Kvasir-SEG, while\nISIC, DRIVE, and pixel-fidelity super-resolution remain behind the strongest\nspecialists. A mask round-trip diagnostic shows that the image representation\npreserves thin structures, locating the remaining gap in conditional spatial\nprecision rather than in the unified output format.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "f3e6f7db-6e2e-4420-979e-7f48d26b2af7"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "MedVision-X: Unifying Medical Image Analysis and Synthesis through Generative Modeling",+ "authors": [],+ "abstract": "Medical image analysis and synthesis are served by separate specialist models:\nsegmentation networks predict label maps, restoration networks recover\nintensities, and translation or editing networks synthesize new images, each\nwith its own architecture, objective, and output head. We ask how far a single\ngenerative model with one image output pathway can go across these\nheterogeneous tasks. We present \\model{}, which casts segmentation,\nsuper-resolution, cross-modal translation, virtual immunohistochemical staining,\nCT denoising, and lesion editing as instruction-conditioned image generation.\nMasks are rendered as color-coded images with an optional text legend and\ncontinuous targets are generated directly, so every task is trained with the\nsame flow-matching objective and decoded by the same image decoder, without\ntask-specific heads or losses. Starting from the SenseNova-Vision unified\nmultimodal model, \\model{} is adapted in two stages: broad adaptation on 1.04M\nmedical records, followed by balanced joint training on the training folds of\n16 benchmarks. Across 14 test benchmarks and 62 scored baseline entries,\n\\model{} obtains the best primary endpoint on 8 and ranks second on 2 more. The\ngains are largest for physically meaningful targets: one checkpoint reduces\nbody HU MAE from 99.0 to 39.1 on low-dose CT and from 83.1 to 55.2 on MRI-to-CT\nsynthesis, and improves PSNR by 4.0\\,dB on LoDoPaB-CT and 3.2\\,dB on IXI.\nDataset-specific segmentation checkpoints lead on BUSI and Kvasir-SEG, while\nISIC, DRIVE, and pixel-fidelity super-resolution remain behind the strongest\nspecialists. A mask round-trip diagnostic shows that the image representation\npreserves thin structures, locating the remaining gap in conditional spatial\nprecision rather than in the unified output format.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}