potentialpaper

ObserveTrace: Explicit Evidence States for Partially Observed EHR Decisions

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 19:04 UTC · 082d307caa7f ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "EW91pUvWfG"
- }
- ],
- "title": "ObserveTrace: Explicit Evidence States for Partially Observed EHR Decisions",
- "authors": [],
- "abstract": "At the moment a renal-risk medication is ordered, no local creatinine can mean never measured, advertised by an external exchange but unavailable, or too old for dosing; a note-derived value can be present yet uncertain. Standard code--value timelines collapse these conditions even though they imply different evidence needs and safety actions. ObserveTrace makes the observation process a first-class model interface: activated evidence requirements become canonical, round-trip-parseable events with value, units, time, provenance, and one of five evidence states. The same event object drives a 7B decoder, constrained alerts, frozen safety rules, and reviewer cards. Observability-aware denoising (OAD) reconstructs workflow-conditioned evidence losses, while incremental clinical consistency (ICC) regularizes adjacent-prefix decisions only when a frozen clinical protocol detects no rule or threshold change. Across 847K high-risk orders from 312K patients at seven health systems, ObserveTrace-7B records 3.2 (2.8--3.7) queue-reaching misses per 1,000 eligible orders, versus 3.8 (3.3--4.4) for an information-, backbone-, and training-budget-matched structured long-context model (paired difference -0.6 (-1.0 to -0.2), $P=0.003$); its false-alert point estimate is also lower, 42.3 versus 43.7. In a fully crossed study, replacing a plain timeline with the complete interface transformation lowers misses from 9.1 to 5.1 before either objective. On 128,640 held-out gate-stable prefix pairs, ICC lowers argmax changes from 0.218 (0.206--0.231) to 0.129 (0.121--0.138), while the action-update rate on 34,920 gate-changing pairs is 0.924 (0.912--0.935). Endpoint concordance is 95.6% with blinded re-adjudication agreement $\\kappa=0.84$; a later 184.4K-order silent study preserves 2.9--3.4 logged queue-reaching misses per 1,000 across Epic, Cerner, and MEDITECH workflows. These results establish explicit evidence state as an effective common boundary for partially observed longitudinal decisions.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "bebad039-ff94-4d56-8c6c-1f712208bd30"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "ObserveTrace: Explicit Evidence States for Partially Observed EHR Decisions",
+ "authors": [],
+ "abstract": "At the moment a renal-risk medication is ordered, no local creatinine can mean never measured, advertised by an external exchange but unavailable, or too old for dosing; a note-derived value can be present yet uncertain. Standard code--value timelines collapse these conditions even though they imply different evidence needs and safety actions. ObserveTrace makes the observation process a first-class model interface: activated evidence requirements become canonical, round-trip-parseable events with value, units, time, provenance, and one of five evidence states. The same event object drives a 7B decoder, constrained alerts, frozen safety rules, and reviewer cards. Observability-aware denoising (OAD) reconstructs workflow-conditioned evidence losses, while incremental clinical consistency (ICC) regularizes adjacent-prefix decisions only when a frozen clinical protocol detects no rule or threshold change. Across 847K high-risk orders from 312K patients at seven health systems, ObserveTrace-7B records 3.2 (2.8--3.7) queue-reaching misses per 1,000 eligible orders, versus 3.8 (3.3--4.4) for an information-, backbone-, and training-budget-matched structured long-context model (paired difference -0.6 (-1.0 to -0.2), $P=0.003$); its false-alert point estimate is also lower, 42.3 versus 43.7. In a fully crossed study, replacing a plain timeline with the complete interface transformation lowers misses from 9.1 to 5.1 before either objective. On 128,640 held-out gate-stable prefix pairs, ICC lowers argmax changes from 0.218 (0.206--0.231) to 0.129 (0.121--0.138), while the action-update rate on 34,920 gate-changing pairs is 0.924 (0.912--0.935). Endpoint concordance is 95.6% with blinded re-adjudication agreement $\\kappa=0.84$; a later 184.4K-order silent study preserves 2.9--3.4 logged queue-reaching misses per 1,000 across Epic, Cerner, and MEDITECH workflows. These results establish explicit evidence state as an effective common boundary for partially observed longitudinal decisions.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}