potentialpaper

REPRIOR: MEASUREMENT-RECONCILED PRIOR CORRECTION FOR SPARSE-VIEW CBCT RECONSTRUCTION

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 19:05 UTC · 92d7dc87d770 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "0xIxCBHyHY"
- }
- ],
- "title": "REPRIOR: MEASUREMENT-RECONCILED PRIOR CORRECTION FOR SPARSE-VIEW CBCT RECONSTRUCTION",
- "authors": [],
- "abstract": "Sparse-view cone-beam computed tomography (CBCT) is severely under-\nconstrained by limited X-ray projections. Learned reconstruction can provide\ncomplementary anatomical information, but using it as a prior in patient-specific\nGaussian reconstruction introduces two challenges. First, the discrepancy between\nthe learned prior and current reconstruction is spatially non-uniform: some local\ndifferences contain useful missing 3D information, whereas others reflect prior\nbias. Second, even a volumetrically beneficial correction can conflict with the\nobserved X-ray measurements. Since X-ray measurements are line integrals, spa-\ntially separated corrections may affect overlapping rays, with their signed projec-\ntion responses reinforcing or partially canceling in the measurement residual, so\ntheir feasibility cannot always be assessed independently. In this paper, we intro-\nduce RePrior, a multi-stage progressive prior-correction framework that addresses\ncorrection actionability, measurement feasibility, and representation expressivity.\nSelective Correction Proposal (SCP) first identifies actionable signed local correc-\ntions from prior–reconstruction discrepancies. Measurement-Constrained Recon-\nciliation (MCR) then jointly enforces their consistency with patient-specific X-\nray measurements, while Hybrid Residual Enhancement (HRE) recovers addi-\ntional correction capacity through complementary voxel- and Gaussian-domain\ndegrees of freedom around the reconciled anchor. RePrior requires neither test-\ntime ground truth nor case-specific network fine-tuning. RePrior gains approx-\nimately 2.6 dB in 3D PSNR over R2-Gaussian across LUNA16, PANORAMA,\nand PENGWIN. Beyond prior-assisted reconstruction, it delivers additional gains\nin volumetric quality and observed-view projection fidelity, with consistent gains\nin held-out-view fidelity in the backbone-matched evaluation.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "60d190dc-0fe2-46a0-9179-b4ef1b6e8aac"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "REPRIOR: MEASUREMENT-RECONCILED PRIOR CORRECTION FOR SPARSE-VIEW CBCT RECONSTRUCTION",
+ "authors": [],
+ "abstract": "Sparse-view cone-beam computed tomography (CBCT) is severely under-\nconstrained by limited X-ray projections. Learned reconstruction can provide\ncomplementary anatomical information, but using it as a prior in patient-specific\nGaussian reconstruction introduces two challenges. First, the discrepancy between\nthe learned prior and current reconstruction is spatially non-uniform: some local\ndifferences contain useful missing 3D information, whereas others reflect prior\nbias. Second, even a volumetrically beneficial correction can conflict with the\nobserved X-ray measurements. Since X-ray measurements are line integrals, spa-\ntially separated corrections may affect overlapping rays, with their signed projec-\ntion responses reinforcing or partially canceling in the measurement residual, so\ntheir feasibility cannot always be assessed independently. In this paper, we intro-\nduce RePrior, a multi-stage progressive prior-correction framework that addresses\ncorrection actionability, measurement feasibility, and representation expressivity.\nSelective Correction Proposal (SCP) first identifies actionable signed local correc-\ntions from prior–reconstruction discrepancies. Measurement-Constrained Recon-\nciliation (MCR) then jointly enforces their consistency with patient-specific X-\nray measurements, while Hybrid Residual Enhancement (HRE) recovers addi-\ntional correction capacity through complementary voxel- and Gaussian-domain\ndegrees of freedom around the reconciled anchor. RePrior requires neither test-\ntime ground truth nor case-specific network fine-tuning. RePrior gains approx-\nimately 2.6 dB in 3D PSNR over R2-Gaussian across LUNA16, PANORAMA,\nand PENGWIN. Beyond prior-assisted reconstruction, it delivers additional gains\nin volumetric quality and observed-view projection fidelity, with consistent gains\nin held-out-view fidelity in the backbone-matched evaluation.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}