potentialpaper

QuPID: Quantum Parameter-Efficient Input-Dependent Retrieval Adaptation for Medical RAG

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 19:07 UTC · 6d6ea45d341c ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "hH7usE20o0"
- }
- ],
- "title": "QuPID: Quantum Parameter-Efficient Input-Dependent Retrieval Adaptation for Medical RAG",
- "authors": [],
- "abstract": "Fidelity-based quantum retrieval ranks candidates by the fidelity between query and archive states. Applying a shared input-independent unitary after fixed state encoding leaves that fidelity unchanged, so training the circuit cannot alter the ranking. Quantum parameter-efficient input-dependent retrieval adaptation (QuPID) repairs this by making the circuit input-dependent through data re-uploading and by comparing measurement readouts, vectors of local Pauli expectations, rather than states. The result is a small readout for adapting frozen image features to a local archive with limited data: training simulates the circuit classically, and inference runs on a GPU with fixed learned parameters. We characterize the class as a structured factorization of input-modulated quadratic feature maps, bound the frequency support of its re-uploading channel, and give a parameter-count generalization bound that motivates its small budget. Under a shared frozen backbone and a label-free protocol, QuPID's 60 parameters give higher precision-at-5 (P@5) on ChestX-ray14 and MURA than frozen medical encoders, and than adapters and low-rank adaptation (LoRA) with up to 5.25 million trainable parameters. On ChestX-ray14, the P@5 gain over the frozen encoder is $+0.116$, the lead over retuned adapters is widest at 512 adaptation examples ($+0.040$), and the full-budget margin over an equally compact classical rotation-plane head is $+0.023$ with a 95\\% interval excluding zero. Medical imaging is the primary testbed; the pattern recurs on two non-medical benchmarks, in report generation, and under simulated gate noise and finite-shot readout.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "40d21df1-0d3b-45ed-aa94-81af2f8b54ae"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "QuPID: Quantum Parameter-Efficient Input-Dependent Retrieval Adaptation for Medical RAG",
+ "authors": [],
+ "abstract": "Fidelity-based quantum retrieval ranks candidates by the fidelity between query and archive states. Applying a shared input-independent unitary after fixed state encoding leaves that fidelity unchanged, so training the circuit cannot alter the ranking. Quantum parameter-efficient input-dependent retrieval adaptation (QuPID) repairs this by making the circuit input-dependent through data re-uploading and by comparing measurement readouts, vectors of local Pauli expectations, rather than states. The result is a small readout for adapting frozen image features to a local archive with limited data: training simulates the circuit classically, and inference runs on a GPU with fixed learned parameters. We characterize the class as a structured factorization of input-modulated quadratic feature maps, bound the frequency support of its re-uploading channel, and give a parameter-count generalization bound that motivates its small budget. Under a shared frozen backbone and a label-free protocol, QuPID's 60 parameters give higher precision-at-5 (P@5) on ChestX-ray14 and MURA than frozen medical encoders, and than adapters and low-rank adaptation (LoRA) with up to 5.25 million trainable parameters. On ChestX-ray14, the P@5 gain over the frozen encoder is $+0.116$, the lead over retuned adapters is widest at 512 adaptation examples ($+0.040$), and the full-budget margin over an equally compact classical rotation-plane head is $+0.023$ with a 95\\% interval excluding zero. Medical imaging is the primary testbed; the pattern recurs on two non-medical benchmarks, in report generation, and under simulated gate noise and finite-shot readout.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}