ReStack-Mamba: Stage-wise Residual Refinement for Volume Electron Microscopy Registration
Update ICLR 2027 submission 1iu1dFNbR5: 1 note
@openreview[bot] · 2026-11-26 04:28 UTC · 59150bac7588 ·
reviews/openreview/1iu1dfnbr5/notes/733zq65lbs.json modified
+++ b/reviews/openreview/1iu1dfnbr5/notes/733zq65lbs.json@@ -13,12 +13,19 @@"critical_strengths": "1. It addresses a practical problem: small alignment errors can disrupt the reconstructed 3D structure.\n\n2. The design makes sense, combining local alignment with information from three viewing directions without requiring labeled deformation fields.\n\n3. The full pipeline shows consistent improvements across six simulated volumes, with an additional example on real data.","critical_weaknesses": "1. The contribution of the learned modules is unclear. Table 2 shows a substantial gain from the final smoothing step, while Stage 2 adds very little. How much of the improvement comes from better alignment? It would help to apply the same post-processing to the baselines and compare the results.\n\n2. The real-data evaluation is limited. The paper only shows qualitative results on one 1,024-slice real-data crop. Testing on more and larger real volumes would strengthen the results. Even without registration labels, downstream tasks such as segmentation could provide quantitative comparisons.\n\n3. The choice of regularization weights needs more explanation. The paper gives the values but does not explain how they were chosen. How sensitive are the results to these weights, and are the same settings used across all datasets and both stages?\n\n4. The computational cost is unclear. There are no runtime or memory comparisons with other methods. The paper should report the cost of the full pipeline, since a large increase in inference time could make the accuracy gains less compelling.\n\n5. The reason for choosing Mamba needs stronger support. Its linear complexity is a reasonable motivation, but the paper does not compare it with other architectures. Comparisons with alternatives such as 3D CNNs or Transformers should report both accuracy and inference cost.\n\n6. Lack of some related works, such as \"Fast and Accurate Electron Microscopy Image Registration\" (MICCAI2019), \"Electron Microscopy Image Registration Using Correlation Volume\" (ISBI2023), and more.","questions_for_authors": "Please refer to \"Critical Weaknesses\".","flag_for_ethics_review": "No",- "rating": 2,+ "rating": 3,"confidence": 4},"createdAt": "2026-10-22T05:47:54.742Z",- "modifiedAt": "2026-11-06T12:17:56.234Z",+ "modifiedAt": "2026-11-26T03:19:58.858Z","url": "https://openreview.net/forum?id=1iu1dFNbR5¬eId=733zQ65LBS",- "license": "CC-BY-4.0"+ "license": "CC-BY-4.0",+ "scoreChanges": [+ {+ "field": "rating",+ "from": 2,+ "at": "2026-11-26T04:28:55.582Z"+ }+ ]}