SCOPE-4D: Endoscopic 4D Geometry Foundation Models
Update ICLR 2027 submission Y0HJnuGgus: 1 note
@openreview[bot] · 2026-11-24 15:42 UTC · c765e7cdfed2 ·
reviews/openreview/y0hjnuggus/notes/whqixbjue1.json modified
+++ b/reviews/openreview/y0hjnuggus/notes/whqixbjue1.json@@ -13,12 +13,12 @@"critical_strengths": "The tracking claim is measured against feed-forward 4D trackers, not only against depth networks, and the prose does not treat the Sano end-point-error loss as a win. On StereoMIS the full model reports end-point error 5.022 against 6.266 for 4RC. The ablation separates a zero-motion anchor from the common–residual step. That is the part of the paper that speaks to the stated ambiguity between camera motion and tissue deformation.\n\nHeld-out checks are not only the training distribution. The colon phantom uses an external tracker. Hamlyn is an existing laparoscopic set. Six experts rank the same 128-frame outputs on ten real colonoscopy clips that the metric tables cannot score. Read as preference, that study is evidence the tables do not contain.","critical_weaknesses": "In-domain depth on EndoMapper-Real is scored against the MapAnything annotations that produced the labels, and that score enters the Table 1 average presented as depth accuracy. The paper does not say the reference is its own annotator. The claim of leading in-domain geometry is not supported for that cell until the average is recomputed on references the model did not train against.\n\nThe long-sequence claim has two unreonciled numbers for the same RealSynCol setting: 27.65 mm in Figure 1 and 71.17 mm in Table 4. A reader cannot tell which number the claim uses. Either figure should be explained, or one of them should be withdrawn.","questions_for_authors": "1. Is EndoMapper-Real depth in Table 1 and Table 15 computed against the MapAnything labels described in Section 3? If so, what is the in-domain absolute-relative error and δ_1.25 with that set removed from the depth average?\n2. What protocol produces the Figure 1 Colon 2 ATE of 27.65 mm, and why does Table 4 report 71.17 mm for long-sequence RealSynCol? Which number supports the long-sequence claim?\n3. For SCARED, which frames are scored, and are the poses the original kinematic poses? The paper already says depth is propagated under a static-scene assumption. SCARED-C (Han et al., arXiv 2605.16628, row 16 of the retrieved literature) is an arXiv preprint and cannot by itself support rejection. The answer still changes how much weight the SCARED numbers can carry.\n4. Should Section 3.2's \"clinical validation\" be read as geometric accuracy, or as the visual preference described in Appendix D.3?","flag_for_ethics_review": "No",- "rating": 2,+ "rating": 3,"confidence": 2},"createdAt": "2026-10-14T13:01:17.992Z",- "modifiedAt": "2026-11-14T12:02:47.104Z",+ "modifiedAt": "2026-11-24T01:51:52.360Z","url": "https://openreview.net/forum?id=Y0HJnuGgus¬eId=whqiXbJUE1","license": "CC-BY-4.0"}