Import ICLR 2027 submission vkPcBShwv4: 3 notes
@openreview[bot] · 2026-11-22 21:49 UTC · 37f9cd11d08b ·
reviews/openreview/vkpcbshwv4/forms.json added
+++ b/reviews/openreview/vkpcbshwv4/forms.json@@ -0,0 +1,183 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "additional_comments_on_reviewer_discussion",+ "label": "Reviewer discussion",+ "type": "text"+ },+ {+ "key": "recommendation",+ "label": "Recommendation",+ "type": "choice"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "soundness",+ "presentation",+ "informativeness"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "soundness",+ "label": "Soundness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "presentation",+ "label": "Presentation",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "informativeness",+ "label": "Informativeness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "paper_summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "critical_strengths",+ "label": "Strengths",+ "type": "text"+ },+ {+ "key": "critical_weaknesses",+ "label": "Weaknesses",+ "type": "text"+ },+ {+ "key": "questions_for_authors",+ "label": "Questions for the authors",+ "type": "text"+ },+ {+ "key": "flag_for_ethics_review",+ "label": "Flag for ethics review",+ "type": "choice",+ "omitWhen": [+ "No",+ "No ethics review needed."+ ]+ },+ {+ "key": "details_of_ethics_concerns",+ "label": "Ethics concerns",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/vkpcbshwv4/notes/b0qvajlrvv.json added
+++ b/reviews/openreview/vkpcbshwv4/notes/b0qvajlrvv.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "B0QVajLRvV",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer eNid",+ "content": {+ "paper_summary": "This paper presents KneeForce, a longitudinal knee osteoarthritis radiograph forecasting framework built on Diffusion Forcing. The method is evaluated on the OAI dataset and an external in-house cohort, with additional ablation studies and a blinded clinician evaluation. The problem is clinically meaningful, and the empirical evaluation is relatively comprehensive.",+ "presentation": 2,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "1. The paper addresses a clinically meaningful and relatively underexplored problem: predicting longitudinal KOA radiographic trajectories rather than only scalar KL grades or isolated future images.\n\n2. The use of Diffusion Forcing is well motivated for long-horizon sequence generation, and explicit time conditioning is a sensible design for irregular clinical follow-up. The TRA formulation using inter-frame relationships from a knee-specific foundation model is also technically coherent.\n\n3. The experimental evaluation is relatively strong for a medical generative modeling paper, including OAI, an external cohort, multiple longitudinal baselines, ablations, and a blinded clinician study.",+ "critical_weaknesses": "1. KneeForce mainly combines Diffusion Forcing with time conditioning, representation alignment to a pretrained knee foundation model, and a separately trained trajectory-ranking module. Each component is reasonable, but the paper does not yet establish a sufficiently distinct learning principle beyond adapting existing techniques to longitudinal knee imaging. The distinction from representation-guided diffusion and prior irregular-time longitudinal generation methods should be made much sharper.\n\n2. Most OAI experiments follow a predefined acquisition schedule, and the paper itself shows that time encoding provides only marginal improvement in this setting. \n\n3. The external cohort is small and the reported results are averaged across available follow-ups rather than explicitly evaluating unseen target intervals. A stronger test would evaluate interpolation and extrapolation to acquisition times not observed during training.\n\n4. The ranking model is trained using the distance between generated trajectories and the ground-truth future sequence, and then selects among multiple diffusion schedules at inference. This is a reasonable selection strategy, but it introduces additional supervision and inference-time search. The paper should report random selection, the best fixed schedule, a simple image-quality-based selector, and an oracle upper bound to clarify how much of the final gain comes from the generator versus candidate selection.",+ "questions_for_authors": "The author can consider responding to the comments in Weakness, and I will consider changing my rating.",+ "flag_for_ethics_review": "No",+ "rating": 2,+ "confidence": 4+ },+ "createdAt": "2026-10-21T15:51:29.268Z",+ "modifiedAt": "2026-11-06T12:18:21.709Z",+ "url": "https://openreview.net/forum?id=vkPcBShwv4¬eId=B0QVajLRvV",+ "license": "CC-BY-4.0"+}
reviews/openreview/vkpcbshwv4/notes/iokyp9rggr.json added
+++ b/reviews/openreview/vkpcbshwv4/notes/iokyp9rggr.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "IoKyP9RGGR",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer 5CFT",+ "content": {+ "paper_summary": "KneeForce adapts Diffusion Forcing to longitudinal knee osteoarthritis X-ray prediction by integrating explicit time-interval encoding, a DINO-based Temporal Relational Alignment strategy, and a Trajectory Selection mechanism to handle unevenly sampled clinical follow-ups and generate clinically plausible disease progressions.",+ "presentation": 2,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "The incorporation of explicit time-interval encoding addresses the non-uniform clinical follow-up schedules inherent in real-world longitudinal data, preventing miscalibrated progression rates.\n\nUtilizing a DINO-based knee foundation model (OrthoFoundation) for Temporal Relational Alignment ensures that the diffusion model focuses on high-level pathological evolution (such as joint space narrowing) rather than superficial texture synthesis.\n\nThe Trajectory Selection strategy successfully mitigates generative stochasticity by filtering candidate trajectories to identify the most clinically probable progression path, which is further validated by a rigorous blinded reader study.",+ "critical_weaknesses": "The performance of Temporal Relational Alignment heavily relies on the representation capacity of the pre-trained DINO knee foundation model; any domain biases or errors present in the expert model risk propagating directly into the generative trajectories.\n\nThe requirement to generate and evaluate multiple candidate trajectories under varying schedules during inference introduces significant computational overhead, which could limit its practicality in real-time clinical workflows.\n\nWhile validated on OAI and an in-house dataset, the framework's reliance on standard Kellgren-Lawrence grading and common progression patterns may constrain its ability to accurately predict atypical, rapid, or multi-factorial joint degeneration cases.",+ "questions_for_authors": "See Weakness",+ "flag_for_ethics_review": "No",+ "rating": 1,+ "confidence": 2+ },+ "createdAt": "2026-10-21T06:21:39.306Z",+ "modifiedAt": "2026-11-06T12:18:23.109Z",+ "url": "https://openreview.net/forum?id=vkPcBShwv4¬eId=IoKyP9RGGR",+ "license": "CC-BY-4.0"+}
reviews/openreview/vkpcbshwv4/notes/xdvw6fjo7b.json added
+++ b/reviews/openreview/vkpcbshwv4/notes/xdvw6fjo7b.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "XDVW6fJO7B",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer gnqn",+ "content": {+ "paper_summary": "The manuscript proposes a diffusion forcing-based framework designed for longitudinal Knee OA radiographic prediction. The design is with three major components to adapt the diffusion forcing to this specific application. First, the time-index is encoded into the latent state to accommodate irregular clinical follow-up schedules. Second, temporal relation alignment distills structural prior knowledge from a frozen pre-trained expert model by aligning frame-to-frame similarity matrices. Third, based on the random nature of the diffusion setting, trajectory candidates are created and selected based on the specific criteria. The authors compare with the existing generation approaches and achieve the best results on two datasets (one public and one in-house) in image generation metrics and OA longitudinal grading accuracy.",+ "presentation": 2,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "- A reasonable engineering practice to adapt GenAI with longitudinal medical image prediction. \n- The problem is worthwhile for exploration and clinically meaningful.",+ "critical_weaknesses": "- The overall framework looks incremental and lacks sufficient new insights to the domain. There are exisiting studies conducting knee OA image prediction in a longitudinal manner using diffusion models. Such generation results are further used for KL grading prediction. \n\n- The design of the proposed components is not well justified and verified.",+ "questions_for_authors": "- The choice of DF is considered by its general flexibility. I was wondering if there is any theoretical or empirical proof that it is superior to other relevant sequential generation strategies.\n\n- The delay $d$ controls the denoising process. Yet, its alignment with actual disease progression is not demonstrated. Using this to predict clinical-meaningful sequence is not well justified.\n\n- What evidence supports the candidate ranking and its selected output as the \"most clinically probable progression\"?\n\n- Missing \"Direct-Forecasting\" baseline: The paper lacks a comparison against classic direct prediction (e.g., using historical frames to directly predict future KL grades). I hope to see that the generated-image-based prediction can outperform this baseline to demonstrate the clinical values.\n\n- While an SSIM of 0.81 suggests the images look similar, in a clinical context, it still indicates noticeable differences (roughly 20% structural mismatch). The authors need to further analyze such differences and their clinical impacts, especially with the discussions of failure cases.\n\n- Can the authors provide an external-cohort ablation of time encoding and controlled experiments at follow-up intervals unseen during training? \n\n- How does performance vary by baseline severity, progression rate, and prediction horizon?\n\n- The human study only proves relative preference among different methods, not absolute clinical usability. It lacks the perspecitve whether generated images improve actual clinical decision-making.\n\n- The methods is with multiple components and with somehow complex designs. The reviewer has the concern regarding the reproducibility, while only the appendix states that 'For detailed implementation please refer to the source code.'\n\n- While SOTA, the absolute KL accuracy drops to ~62% at 96 months (nearly 40% of the predictions are misgraded and two-year observation has been conducted already). The image metric gains are marginal. These raise concerns about whether the generated images are reliable enough for real-world clinical use.",+ "flag_for_ethics_review": "No",+ "rating": 1,+ "confidence": 3+ },+ "createdAt": "2026-10-19T15:09:13.342Z",+ "modifiedAt": "2026-11-06T12:18:23.996Z",+ "url": "https://openreview.net/forum?id=vkPcBShwv4¬eId=XDVW6fJO7B",+ "license": "CC-BY-4.0"+}
reviews/openreview/vkpcbshwv4/submission.json added
+++ b/reviews/openreview/vkpcbshwv4/submission.json@@ -0,0 +1,18 @@+{+ "schema": "submission/1",+ "id": "vkPcBShwv4",+ "venue": {+ "id": "ICLR.cc/2027/Conference",+ "name": "ICLR 2027",+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference"+ },+ "number": 12129,+ "keywords": [+ "Longitudinal Medical Image Prediction",+ "Diffusion Forcing",+ "Knee Osteoarthritis",+ "Disease Progression Modeling"+ ],+ "url": "https://openreview.net/forum?id=vkPcBShwv4",+ "license": "CC-BY-4.0"+}
versions/v_epg75dm6.json modified
+++ b/versions/v_epg75dm6.json@@ -1,7 +1,20 @@{+ "date": "2026-09-09","kind": "submitted","label": "ICLR 2027 (under review)",+ "submissions": [+ {+ "venue": "ICLR 2027",+ "status": "under_review",+ "number": 12129,+ "url": "https://openreview.net/forum?id=vkPcBShwv4",+ "reviews": "openreview/vkpcbshwv4",+ "evidence": [+ "https://openreview.net/forum?id=vkPcBShwv4"+ ]+ }+ ],"url": "https://openreview.net/forum?id=vkPcBShwv4","pdf": {"source": "https://openreview.net/forum?id=vkPcBShwv4","license": "CC-BY-4.0"