Medical-4D: 4D Cardiac MRI Vision-Language Models for Cardiac Function Understanding
Update ICLR 2027 submission 86qMayAaaT: 1 note
@openreview[bot] · 2026-11-24 20:24 UTC · a05a5bb72660 ·
reviews/openreview/86qmayaaat/notes/ageghe5vlb.json modified
+++ b/reviews/openreview/86qmayaaat/notes/ageghe5vlb.json@@ -14,12 +14,12 @@"critical_weaknesses": "- The novelty of the core contributions is limited. Most of the elements (factorized attention, contrastive alignment with hard negatives, masked cross-modal recovery) that constitute the framework are well established. The two contributions that could be considered novel, the clinically structured masking stage and the use of the full cine sequence (30 phases per slice), are not supported by the results. For the first one, the improvements it brings are limited (up to 0.8 points). For the second one, while the standard approach in clinical practice is to use ED and ES, the paper fails to demonstrate that the extra phases bring added value.\n\n- Multiple aspects of the evaluation need to be revised. To start with, the method is tested on a single split and does not report standard deviations from multiple runs or statistical tests. As some differences are narrow, it is not possible to establish if those are simply due to noise. Second, Q&As are generated from reports by an LLM (Qwen) with only a rough manual screening. Therefore, the evaluation measures whether the model can reproduce the information in the report, not whether cardiac function is correctly assessed. Lastly, it seems that some baselines do not get a fair evaluation (see questions for a clarification).","questions_for_authors": "1. How does Medical-4D perform when restricted to ED and ES frames, or to fewer phases (e.g., 10, 15)? This would show whether the additional phases bring added value over standard clinical practice.\n2. Can the authors report mean and standard deviation over multiple runs or cross-validation folds, with statistical tests for the key comparisons, particularly where differences are below one point?\n3. Was CineMA given both ED and ES frames, as in its original design, or a single time point? Were CMR-CLIP and CMR-Transformer evaluated with their original multi-slice inputs?","flag_for_ethics_review": "Yes","details_of_ethics_concerns": "The paper uses clinical data from three different centers. I suppose that, for anonymization purposes, full details cannot be disclosed at this stage. If the paper goes further and it is accepted, the authors would need to disclose information about IRB approval of the study and consent on the usage of the data.",- "rating": 1,+ "rating": 2,"confidence": 2},"createdAt": "2026-10-23T14:43:44.807Z",- "modifiedAt": "2026-11-06T12:18:23.064Z",+ "modifiedAt": "2026-11-24T19:50:30.977Z","url": "https://openreview.net/forum?id=86qMayAaaT¬eId=aGEGHe5VLB","license": "CC-BY-4.0"}