Prevalence Determines Precision: Silent Contamination in Detector-Defined Datasets
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 19:11 UTC · bb6617a45b3f ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "l6vE1BzJi6"- }- ],- "title": "Prevalence Determines Precision: Silent Contamination in Detector-Defined Datasets",- "authors": [],- "abstract": "A large share of machine learning datasets are not observed but constructed: a detector, heuristic, or model is run\nover a pool of candidates, and whatever it accepts becomes the dataset. Weak and distant supervision, pseudo-labelling,\nevent extraction, and most anomaly-detection benchmarks all have this form. The precision of the resulting dataset is\nnot a property of the detector. It is governed by the prevalence π of true positives in the pool the detector is deployed on,\nthrough elementary Bayes. This is textbook, and it is nonetheless almost never measured end-to-end, for a structural\nreason: from inside a detector-defined dataset the false positives are unidentifiable, so the quantity that matters cannot\nbe estimated by the people who need it. We report a case in which it can be measured. For the same instrument\nand period we hold both a detector-defined event dataset and an independent official index that reveals, for every\ndetected item, whether it is real. One detector, three candidate pools, three datasets: phantom rates of 81.7%, 9.0%,\nand 0.0%. A practitioner transferring precision from the two high-π pools to the low-π pool predicts 0.955 against\na measured 0.183, an error of +422%; the Bayes expression predicts within 3.3% across all three pools. Beyond\nconfirming the mechanism we report three findings that we believe are new. First, the detected dataset’s response\ncurve is an exact convex combination of a true-event and a phantom component (identity residual 1.1 × 10−16), with\nphantoms outnumbering true events 473 to 308 — contamination is not noise added to signal but a second signal with\nits own shape, inherited from the detector’s acceptance rule. Second, the direction of contamination is a property of\nthe estimator, not of the data: on identical windows, one statistic shows contamination diluting the effect and another\nshows it inflating the effect, because the second statistic’s denominator is itself contaminated. Third, a normalisation\nin common use turns the estimator into a mean of ratios whose expectation does not exist; on the same 335 events it\nreturns 0.40 where the well-defined estimator returns 0.10.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "00f7b310-1d98-4bac-bbb9-b178beaa3fde"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "Prevalence Determines Precision: Silent Contamination in Detector-Defined Datasets",+ "authors": [],+ "abstract": "A large share of machine learning datasets are not observed but constructed: a detector, heuristic, or model is run\nover a pool of candidates, and whatever it accepts becomes the dataset. Weak and distant supervision, pseudo-labelling,\nevent extraction, and most anomaly-detection benchmarks all have this form. The precision of the resulting dataset is\nnot a property of the detector. It is governed by the prevalence π of true positives in the pool the detector is deployed on,\nthrough elementary Bayes. This is textbook, and it is nonetheless almost never measured end-to-end, for a structural\nreason: from inside a detector-defined dataset the false positives are unidentifiable, so the quantity that matters cannot\nbe estimated by the people who need it. We report a case in which it can be measured. For the same instrument\nand period we hold both a detector-defined event dataset and an independent official index that reveals, for every\ndetected item, whether it is real. One detector, three candidate pools, three datasets: phantom rates of 81.7%, 9.0%,\nand 0.0%. A practitioner transferring precision from the two high-π pools to the low-π pool predicts 0.955 against\na measured 0.183, an error of +422%; the Bayes expression predicts within 3.3% across all three pools. Beyond\nconfirming the mechanism we report three findings that we believe are new. First, the detected dataset’s response\ncurve is an exact convex combination of a true-event and a phantom component (identity residual 1.1 × 10−16), with\nphantoms outnumbering true events 473 to 308 — contamination is not noise added to signal but a second signal with\nits own shape, inherited from the detector’s acceptance rule. Second, the direction of contamination is a property of\nthe estimator, not of the data: on identical windows, one statistic shows contamination diluting the effect and another\nshows it inflating the effect, because the second statistic’s denominator is itself contaminated. Third, a normalisation\nin common use turns the estimator into a mean of ratios whose expectation does not exist; on the same 335 events it\nreturns 0.40 where the well-defined estimator returns 0.10.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}