Flow-Matching Based Refiner for Molecular Conformer Generation
Import the versions from OpenReview: the same title at other venues
@openreview[bot] · 2026-11-22 19:56 UTC · e85dbf8f79fa ·
versions/v_dt2zmeu9.json added
+++ b/versions/v_dt2zmeu9.json@@ -0,0 +1,18 @@+{+ "date": "2026-09-10",+ "kind": "submitted",+ "label": "ICLR 2027",+ "submissions": [+ {+ "venue": "ICLR 2027",+ "status": "under_review",+ "url": "https://openreview.net/forum?id=D8ewD7A7dL"+ }+ ],+ "title": "Flow-Matching Based Refiner for Molecular Conformer Generation",+ "url": "https://openreview.net/forum?id=D8ewD7A7dL",+ "evidence": [+ "https://openreview.net/forum?id=D8ewD7A7dL"+ ],+ "abstract": "Low-energy molecular conformer generation (MCG) is a foundational yet challenging problem in drug discovery. Denoising-based generative models, including diffusion and flow matching, have become the dominant paradigm for MCG and achieved state-of-the-art performance by transporting samples from a simple base distribution to the molecular conformer distribution. However, sequential sampling can accumulate errors, especially in low-SNR regimes where inference states deviate from their timestep-conditioned training distributions. This train-inference mismatch makes vector-field prediction on off-trajectory states unreliable, further propagating errors through denoising.\nTo address this issue, we propose a mismatch-aware flow-matching framework for molecular conformer refinement. Trained on data-centered perturbations, the refiner corrects upstream conformers without requiring explicit estimates of their residual error. Experiments on GEOM-QM9 and GEOM-Drugs show consistent quality improvements across strong denoising-based generators, while preserving diversity and reducing the total number of sampling steps."+}
versions/v_jnxgwf9m.json added
+++ b/versions/v_jnxgwf9m.json@@ -0,0 +1,18 @@+{+ "date": "2025-09-20",+ "kind": "submitted",+ "label": "ICLR 2026",+ "submissions": [+ {+ "venue": "ICLR 2026",+ "status": "rejected",+ "url": "https://openreview.net/forum?id=yLiL7iv5bO"+ }+ ],+ "title": "Flow-Matching based Refiner for Molecular Conformer Generation",+ "url": "https://openreview.net/forum?id=yLiL7iv5bO",+ "evidence": [+ "https://openreview.net/forum?id=yLiL7iv5bO"+ ],+ "abstract": "Low-energy molecular conformers generation (MCG) is a foundational yet challenging problem in drug discovery. \nDenoising-based methods include diffusion and flow-matching methods that learn mappings from a simple base distribution to the molecular conformer distribution. However, these approaches often suffer from error accumulation during sampling, especially in the low SNR steps, which are hard to train. To address these challenges, we propose a flow-matching refiner for the MCG task. \nThe proposed method initializes sampling from mixed-quality outputs produced by upstream denoising models and reschedules the noise scale to bypass the low-SNR phase, thereby improving sample quality. On the GEOM-QM9 and GEOM-Drugs benchmark datasets, the generator–refiner pipeline improves quality with fewer total denoising steps while preserving diversity."+}