Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 19:12 UTC · 7345503c5137 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "Ciqf5sZi7l"- }- ],- "title": "READ-ECG: ECG Printout Digitisation via Structured Visual Sequence Regression for Cardiovascular Analysis",- "authors": [],- "abstract": "Electrocardiograms (ECGs) are a primary cardiovascular diagnostic modality, but recordings available only as scanned or photographed printouts cannot be directly processed by signal-based AI tools. Direct image analysis entangles signal extraction with clinical interpretation, while multi-stage digitisation pipelines rely on brittle segmentation steps. We formulate ECG printout digitisation as a structured visual sequence regression problem within a decoupled Image → Signal → Analysis pipeline. We introduce READ-ECG (Reconstruction and Extraction via Attention-based Decoding of ECGs), an end-to-end framework that bypasses intermediate trace segmentation, employing a topology-aware attention-based decoder to directly regress spatial features into continuous multi-lead waveforms. To support future quality-control workflows, we incorporate aleatoric uncertainty modelling to identify potentially unreliable reconstructions. Evaluated across diverse benchmarks, READ-ECG achieves high-fidelity reconstruction on the combined PhysioNet evaluation (PCC: 0.998, SNR: 28.83 dB) and can adapt to severe real-world visual artefacts using only 81 real training images. Across three PTB-XL classification task families, a residual 1D CNN trained on original signals retains a mean AUROC of 0.927 on READ-ECG reconstructions. Evaluation with two pre-trained ECG foundation models further suggests that the digitised signals retain diagnostic information. By decoupling signal “reading” from “interpretation”, READ-ECG provides reusable waveforms to the signal-based cardiac AI ecosystem.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "8b7cdd2f-09c2-4bdd-b19f-e4f34dafddec"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "READ-ECG: ECG Printout Digitisation via Structured Visual Sequence Regression for Cardiovascular Analysis",+ "authors": [],+ "abstract": "Electrocardiograms (ECGs) are a primary cardiovascular diagnostic modality, but recordings available only as scanned or photographed printouts cannot be directly processed by signal-based AI tools. Direct image analysis entangles signal extraction with clinical interpretation, while multi-stage digitisation pipelines rely on brittle segmentation steps. We formulate ECG printout digitisation as a structured visual sequence regression problem within a decoupled Image → Signal → Analysis pipeline. We introduce READ-ECG (Reconstruction and Extraction via Attention-based Decoding of ECGs), an end-to-end framework that bypasses intermediate trace segmentation, employing a topology-aware attention-based decoder to directly regress spatial features into continuous multi-lead waveforms. To support future quality-control workflows, we incorporate aleatoric uncertainty modelling to identify potentially unreliable reconstructions. Evaluated across diverse benchmarks, READ-ECG achieves high-fidelity reconstruction on the combined PhysioNet evaluation (PCC: 0.998, SNR: 28.83 dB) and can adapt to severe real-world visual artefacts using only 81 real training images. Across three PTB-XL classification task families, a residual 1D CNN trained on original signals retains a mean AUROC of 0.927 on READ-ECG reconstructions. Evaluation with two pre-trained ECG foundation models further suggests that the digitised signals retain diagnostic information. By decoupling signal “reading” from “interpretation”, READ-ECG provides reusable waveforms to the signal-based cardiac AI ecosystem.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}