potentialpaper

Representation Symmetries and Architectural Constraints on Probe Identifiability

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 19:15 UTC · 47d3286d0235 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "cVAyq1VS0A"
- }
- ],
- "title": "Representation Symmetries and Architectural Constraints on Probe Identifiability",
- "authors": [],
- "abstract": "A central question in neural representation analysis is when observations of hidden representations uniquely determine an associated symbolic assignment. A symbolic label may be predicted accurately from a representation without being uniquely determined by the observed information. Architectural information can restrict hidden-coordinate changes that preserve a neural model and its observations, but invariance under known symmetries does not by itself imply identifiability. We distinguish observational identifiability, symmetry invariance, and agreement of fixed linear sign-probe predictions. A general observation-factorization criterion characterizes exact extractability, while full-space and boundary-local probe criteria identify the positive-ray condition for exact agreement. We then study finite representation calibration, where allowed orthogonal transformations fix specified hidden states pointwise. For an explicit norm-and-inner-product observation protocol on a known linear subspace, we classify every observational fibre and characterize both global and fibrewise probe identifiability. Under Gaussian evaluation, the largest disagreement over all calibration-preserving transformations has a closed form determined by the uncalibrated component of the effective probe and is attained by a Householder reflection. Independent Gaussian calibration gives an exact finite-sample law governed by the support dimension. Architectural stabilizers provide upper bounds, not automatic completeness certificates. Controlled FP64 experiments agree with the finite-calibration predictions. Calibration-preserving weight changes in Pythia-1.4B and Pythia-2.8B still change fixed-probe predictions, while complete-forward checks identify a reproducible numerical deviation under one joint intervention.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "3a718513-8348-431e-869d-209e2b44b837"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "Representation Symmetries and Architectural Constraints on Probe Identifiability",
+ "authors": [],
+ "abstract": "A central question in neural representation analysis is when observations of hidden representations uniquely determine an associated symbolic assignment. A symbolic label may be predicted accurately from a representation without being uniquely determined by the observed information. Architectural information can restrict hidden-coordinate changes that preserve a neural model and its observations, but invariance under known symmetries does not by itself imply identifiability. We distinguish observational identifiability, symmetry invariance, and agreement of fixed linear sign-probe predictions. A general observation-factorization criterion characterizes exact extractability, while full-space and boundary-local probe criteria identify the positive-ray condition for exact agreement. We then study finite representation calibration, where allowed orthogonal transformations fix specified hidden states pointwise. For an explicit norm-and-inner-product observation protocol on a known linear subspace, we classify every observational fibre and characterize both global and fibrewise probe identifiability. Under Gaussian evaluation, the largest disagreement over all calibration-preserving transformations has a closed form determined by the uncalibrated component of the effective probe and is attained by a Householder reflection. Independent Gaussian calibration gives an exact finite-sample law governed by the support dimension. Architectural stabilizers provide upper bounds, not automatic completeness certificates. Controlled FP64 experiments agree with the finite-calibration predictions. Calibration-preserving weight changes in Pythia-1.4B and Pythia-2.8B still change fixed-probe predictions, while complete-forward checks identify a reproducible numerical deviation under one joint intervention.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}