potentialpaper

STANCE: Scene-Consistent Real-Time Motion Estimation from Sparse Wearables via Posterior-Corrected Residual Diffusion

Import ICLR 2027 submission B32kixKT6j: 23 notes

@openreview[bot] · 2026-11-22 20:25 UTC · 57e7d8a6090e

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,19 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "B32kixKT6j"
+ }
+ ],
+ "title": "STANCE: Scene-Consistent Real-Time Motion Estimation from Sparse Wearables via Posterior-Corrected Residual Diffusion",
+ "authors": [],
+ "abstract": "Wearable tracking began as a way to drive game avatars and has since become an instrument for embodied intelligence, where human demonstrations captured from a few body-worn sensors train agents inside simulated environments. Configurations vary widely: a headset and two controllers give three 6-DoF signals, and optional hip and foot trackers extend this to six. Methods that accept arbitrary sensor sets fix each tracker's influence in advance, zero-padding or masking absent channels with hand-crafted weights that encode measurement presence rather than reliability. A second gap opens only inside the scene: signals captured in a physical room are replayed in a virtual one, and the mismatch surfaces as limbs passing through the very geometry the motion is meant to interact with.\n\nWe present STANCE, which predicts and then corrects. A configuration-agnostic predictor forecasts a temporally coherent prior from a fixed set of core sites, so continuity never depends on which trackers are present, while a single-frame residual denoiser rewrites only what the trackers contradict, keeping accuracy and latency from trading against each other. How far a partial inverse-kinematics solve travels from the prior, and how closely it meets the trackers, give each joint a continuous trust gating how much the denoiser may rewrite; a configuration change then alters feature values and nothing else. Inside the denoiser, a training-free posterior-sampling procedure corrects the predicted residual against scene geometry at every diffusion step, removing penetration without retraining or a learned collision model. STANCE runs in real time, reaches state-of-the-art accuracy across most tracker counts, and holds continuity through dynamic reconfiguration.",
+ "year": 2027,
+ "venue": "ICLR 2027 (under review)",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/b32kixkt6j/forms.json added

+++ b/reviews/openreview/b32kixkt6j/forms.json
@@ -0,0 +1,183 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "additional_comments_on_reviewer_discussion",
+ "label": "Reviewer discussion",
+ "type": "text"
+ },
+ {
+ "key": "recommendation",
+ "label": "Recommendation",
+ "type": "choice"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "soundness",
+ "presentation",
+ "informativeness"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "soundness",
+ "label": "Soundness",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "presentation",
+ "label": "Presentation",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "informativeness",
+ "label": "Informativeness",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "paper_summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "critical_strengths",
+ "label": "Strengths",
+ "type": "text"
+ },
+ {
+ "key": "critical_weaknesses",
+ "label": "Weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions_for_authors",
+ "label": "Questions for the authors",
+ "type": "text"
+ },
+ {
+ "key": "flag_for_ethics_review",
+ "label": "Flag for ethics review",
+ "type": "choice",
+ "omitWhen": [
+ "No",
+ "No ethics review needed."
+ ]
+ },
+ {
+ "key": "details_of_ethics_concerns",
+ "label": "Ethics concerns",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/2ejyx77kqr.json added

+++ b/reviews/openreview/b32kixkt6j/notes/2ejyx77kqr.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "2eJYx77Kqr",
+ "replyTo": "RyVsLfUjzy",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer dJdg",
+ "content": {
+ "title": "Official Comment of by Reviewer dJdg",
+ "comment": "Thank you for the author’s detailed explanation to my concerns and efforts to provide additional experiments. I improve my score to weak reject. Though the paper is improved and the additional experiments show effectiveness, the readability concern remains, and more experiments on public datasets may further strengthen the scene consistency design."
+ },
+ "createdAt": "2026-11-19T05:47:06.118Z",
+ "modifiedAt": "2026-11-19T05:47:06.118Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=2eJYx77Kqr",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/5bptthiasr.json added

+++ b/reviews/openreview/b32kixkt6j/notes/5bptthiasr.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "5BpTthIasR",
+ "replyTo": "TEqnoLsHbB",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you for your valuable feedbacks.(Q3)",
+ "comment": "**Q3: Preventing the mesh from floating in space**\n\nWe thank the reviewer for raising this important question. **Foot floating can be addressed by contact detection and IK post-processing alone**, without involving the posterior correction. To verify this, we conducted a controlled ablation on standing sequences with valid foot-tracker observations, comparing results with and without contact-aware IK post-processing (foot anchoring, leg IK, and a small pelvis-height adjustment). Both settings retain the same anti-penetration processing and share identical support labels derived independently from raw tracker measurements.\n\n| Metric | w/o contact IK | w/ contact IK |\n|---|---:|---:|\n| Floating ratio, clearance > 1 cm | 8.39% | **0.00%** |\n| Floating ratio, clearance > 5 mm | 49.60% | **1.21%** |\n| Mean clearance | 5.37 mm | **2.12 mm** |\n| P95 clearance | 10.18 mm | **2.11 mm** |\n| Max. ground penetration | 0.00 mm | 0.00 mm |\n\nClearance is measured from the lowest skinned foot vertex to the ground and time-weighted over both feet. This causal post-processing stage adds only 0.76 ms per displayed frame.\n\n**The two mechanisms serve complementary roles**. Our posterior energy is one-sided by construction: it penalizes penetration and provides no attraction toward scene geometry. We therefore handle attraction separately, where the target contact is unambiguous. **Foot-ground contact during standing is a well-defined planar constraint** that local IK can resolve when reliable foot-tracker observations are available. In contrast, **interactions with scene objects involve multiple body regions**, differently oriented surfaces, and dynamically changing contacts. Such constraints are difficult to resolve through isolated IK corrections without disrupting other body configurations. STANCE's posterior correction instead incorporates scene geometry into the reverse diffusion process, jointly balancing these constraints against motion fidelity. Thus, **the two mechanisms are complementary rather than interchangeable**.\n\nMaskedMimic pursues a different objective: **it synthesizes physically plausible motion**, with sparse targets serving as guidance that the policy is encouraged to follow. In this setting, deviations from the targets can be acceptable if they improve physical plausibility. STANCE, in contrast, aims to **faithfully reconstruct the user's actual motion**, making such deviations a direct reconstruction error. \n\nThis ablation is limited to standing sequences with both foot trackers valid, where support states can be determined directly from sensor measurements. Scenarios with non-planar support surfaces would require a dedicated contact predictor to provide support labels."
+ },
+ "createdAt": "2026-11-15T06:28:05.454Z",
+ "modifiedAt": "2026-11-15T06:28:05.454Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=5BpTthIasR",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/7iyrha72xd.json added

+++ b/reviews/openreview/b32kixkt6j/notes/7iyrha72xd.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "7IYRHA72XD",
+ "replyTo": "TEqnoLsHbB",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Looking forward to your improving the final score in the system.",
+ "comment": "Dear Reviewer Cn7B,\n\nThank you for your efforts and valuable comments on improving the quality of our manuscript. We kindly remind that the discussion time is coming to an end. We are also glad to hear that you are willing to raise the score, and we look forward to your editing the final score in the system. Thank you again for your efforts and please feel free to contact us if you have any further questions.\n\nBest regards,\n\nThe Authors of STANCE"
+ },
+ "createdAt": "2026-11-18T07:12:02.591Z",
+ "modifiedAt": "2026-11-18T07:12:02.591Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=7IYRHA72XD",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/dmnkovy4di.json added

+++ b/reviews/openreview/b32kixkt6j/notes/dmnkovy4di.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "DMNKoVY4DI",
+ "replyTo": "qy1e6LQ6ed",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer hADe,\n\nThank you again for the great efforts and valuable comments. We hope you find the response satisfactory. As the discussion phase is about to close, we are eagerly looking forward to hearing from you regarding any further feedback. We will be more than happy to address any additional concerns you may have.\n\nBest,\n\nSTANCE Authors"
+ },
+ "createdAt": "2026-11-17T08:34:05.109Z",
+ "modifiedAt": "2026-11-17T08:34:05.109Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=DMNKoVY4DI",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/e54ljlxzxd.json added

+++ b/reviews/openreview/b32kixkt6j/notes/e54ljlxzxd.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "e54lJLXzxD",
+ "replyTo": "kqgmGgrmDh",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for acknowledging our additional analyses. We would like to further clarify the motivation and novelty of the kinematics-based confidence estimator.\n\n**Motivation.** Binary availability masks indicate whether a tracker is present, but cannot capture the reliability of its measurements. Our estimator uses the discrepancy between tracker observations and kinematically constrained IK solutions to derive continuous, joint-level confidence scores, allowing STANCE to adapt its residual corrections to measurement reliability.\n\n**Novelty.** To the best of our knowledge, prior sparse-tracker motion reconstruction methods primarily use binary tracker availability, whereas STANCE explicitly incorporates kinematic consistency into continuous confidence estimation and uses these scores to guide residual reconstruction.\n\n**Evidence.** **Our confidence-versus-binary ablation(in Q2)** demonstrates consistent improvements in reconstruction accuracy under both 3-point and 6-point configurations. **The supplementary demonstrations** further illustrate how confidence-guided reconstruction responds to varying tracker reliability.",
+ "title": "Clarification of Kinematics-Based Confidence(Q6)"
+ },
+ "createdAt": "2026-11-18T06:37:48.094Z",
+ "modifiedAt": "2026-11-19T09:50:28.986Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=e54lJLXzxD",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/fx5xucgd2q.json added

+++ b/reviews/openreview/b32kixkt6j/notes/fx5xucgd2q.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "fx5xUCgd2q",
+ "replyTo": "qy1e6LQ6ed",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you for your valuable feedbacks. (Q1&Q2)",
+ "comment": "We sincerely thank **Reviewer hADe** for the careful reading, and in particular for recognising that \"confidence is a distinguishing factor of this work\". We take the novelty concern seriously and use this response to state our claim more precisely than the submission did.\n\n**Q1: Clarification on the conceptual novelty**\n\nWe agree that both the single-frame residual DiT and test-time posterior sampling are established tools. **Our contribution is a predict-confidence-correct mechanism** for real-time motion estimation from sparse sensors, where both tracker configurations and observation reliability can change dynamically. Crucially, **these components are tightly coupled rather than independently assembled**: the predictor provides the reference pose for residual construction, while the confidence $\\mathbf{m}_n$ defines the gated residual target during training, conditions the denoiser, and gates the posterior correction. Moreover, performing diffusion and posterior correction in this shared residual space anchors scene guidance to the denoiser's motion estimate. Thus, each component is designed to work in concert with the others. Specifically, our innovations are threefold:\n1. We **decouple a configuration-independent motion prior from an observation-dependent correction**, allowing a single set of weights to support tracker configurations that change at run time. The same checkpoint achieves state-of-the-art performance on most metrics under both 3- and 6-tracker configurations.\n2. We **propose kinematic consistency-driven confidence**, replacing binary availability with a per-joint trust score derived from partial inverse kinematics (IK). The key insight is that **a reliable tracker measurement should be consistent with the body's kinematic structure**: its constraint should be satisfiable when propagated through the corresponding kinematic chain. We therefore use the gap between the partial-IK solution and the tracker target to quantify confidence, with a larger gap indicating lower confidence. This confidence is propagated to the joints governed by each tracker, enabling targeted corrections based on observation reliability.\n3. We **impose scene constraints through training-free posterior correction at every reverse diffusion step**, rather than applying a post-hoc collision fix to the final SMPL pose. Each step balances motion fidelity against scene consistency while the pose is being refined. Since no scene information is required during training and no weights are updated, the same checkpoint can accommodate different scene geometries at inference without retraining.\n\n**Q2: Comparison against a binary availability mask**\n\nWe thank the reviewer for this suggestion and agree that this comparison is necessary. We therefore added an ablation under the same A-P2 protocol as Tab. 1, replacing continuous confidence $\\mathbf{m}_n$ with a binary availability mask while keeping all else fixed.\n\n$$\n\\\\begin{array}{llcccc}\n\\\\hline\n\\\\textbf{Config} & \\\\textbf{Variant} & \\\\textbf{MPJRE}\\\\downarrow\\\\, & \\\\textbf{MPJPE}\\\\downarrow\\\\, & \\\\textbf{MPJVE}\\\\downarrow\\\\, & \\\\textbf{Jitter}\\\\downarrow \\\\\\\\\n\\\\hline\n\\\\text{3-point} & \\\\text{binary mask} & 4.99 & 5.58 & 21.92 & 0.962 \\\\\\\\\n\\\\text{3-point} & \\\\text{confidence} & \\\\mathbf{4.66} & \\\\mathbf{5.31} & \\\\mathbf{21.23} & \\\\mathbf{0.958} \\\\\\\\\n\\\\hline\n\\\\text{6-point} & \\\\text{binary mask} & 3.73 & 1.16 & 8.41 & 1.17 \\\\\\\\\n\\\\text{6-point} & \\\\text{confidence} & \\\\mathbf{3.37} & \\\\mathbf{1.07} & \\\\mathbf{8.29} & \\\\mathbf{1.16} \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$\n\nContinuous confidence consistently improves accuracy in both configurations, with larger gains at 6 trackers: MPJRE improves by 9.7% vs. 6.6%, and MPJPE by 7.8% vs. 4.8%, under 6- and 3-point settings, respectively. **This is counterintuitive**, as more trackers might be expected to reduce the need to distinguish among readings. However, **tracker drift and noise can make additional readings mutually inconsistent. Binary gating admits every available reading at full strength, so more trackers can introduce more conflicting constraints.** In contrast, continuous confidence can downweight unreliable measurements, explaining its increasing advantage as the number of trackers grows. The largest gains are in rotation accuracy, consistent with confidence helping resolve rotational ambiguity along kinematic chains, which is important for motion retargeting and replay. Jitter changes little, as expected: $m_n$ controls the joint-wise residual correction strength, whereas the ramped temporal admission $\\alpha_n^k$, which smooths tracker reconfiguration, remains unchanged. Overall, these results demonstrate the advantage of reliability-aware correction over binary availability."
+ },
+ "createdAt": "2026-11-14T13:03:31.499Z",
+ "modifiedAt": "2026-11-14T13:03:31.499Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=fx5xUCgd2q",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/grtsd3re3s.json added

+++ b/reviews/openreview/b32kixkt6j/notes/grtsd3re3s.json
@@ -0,0 +1,25 @@
+{
+ "schema": "review/1",
+ "id": "GrtSd3RE3S",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer dJdg",
+ "content": {
+ "paper_summary": "This paper studies human motion reconstruction (HMR) from body-worn IMU sensor trackers under a configuration-agnostic setting: 3 compulsory trackers (always available) and 3 optional trackers (whose signals may occasionally be lost). To mitigate occasional signal loss, it proposes STANCE, a diffusion-based framework. It starts from a coarse pose prediction, calculates the per-joint confidence using available tracker measurements, and refines the poses through diffusion refinement. It also designs training-free guidance based on scene geometry to reduce scene penetration, but it does not show how to obtain this scene. Overall, the methodology design is not clearly structured and is questionable.",
+ "presentation": 1,
+ "informativeness": 2,
+ "soundness": 2,
+ "critical_strengths": "The research tries to improve the robustness of IMU-based HMR and improve temporal consistency and accuracy during sensor signal loss. It is a meaningful research direction for real-world deployment.\n\nThe proposed method is claimed to support real-time Unity rendering.",
+ "critical_weaknesses": "1. Mathematical symbols are not well organized: lower-case s_n^k, upper-case S^c, and u^k_m all stand for sensor measurements. H stands for both the future window size and the feature representation. Both n and m are used in timestamps. In Equation 5, the historical poses x are input to the model rather than \\bar{x}. Please clarify whether you use GT history or predicted history. These misuses of symbols make the method difficult to comprehend.\n\n2. Missing important details: How do you obtain y_floor for coordinate transformation? Moreover, FABRIK is undefined, and there is no reference. Do you use human limb lengths during IK? How do you obtain or estimate GT human limb lengths?\n\n3. The geometric term on the reconstructed pose in L_geo is undefined.\n\n4. The paper does not describe how the prior scene is constructed in Sec. 3.5. If it is not estimated from head observations, it raises fairness concerns since other methods do not have access to this prior scene.",
+ "questions_for_authors": "No",
+ "flag_for_ethics_review": "No",
+ "details_of_ethics_concerns": "No",
+ "rating": 2,
+ "confidence": 4
+ },
+ "createdAt": "2026-10-20T04:39:21.109Z",
+ "modifiedAt": "2026-11-19T06:06:24.260Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=GrtSd3RE3S",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/hzhu8fprxw.json added

+++ b/reviews/openreview/b32kixkt6j/notes/hzhu8fprxw.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "HzHU8fPrxW",
+ "replyTo": "TEqnoLsHbB",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "**Q1: Comparison with existing opportunistic guidance mechanisms**\n\nWe thank Reviewer Cn7B for pointing out the lack of comparisons with existing guidance mechanisms. To address this concern, we conduct controlled comparisons with two alternative scene-correction strategies: an LM-based optimizer, motivated by EgoAllo [2], and a $\\Pi$GDM-based guidance mechanism, motivated by InPose [3].\n\nWe compare three mechanisms while keeping the Predictor, DiT weights, input conditions, DDIM sampling schedule, and final pose projection unchanged:\n\n- **Ours:** Gradient-based optimization of the predicted clean motion residual at each reverse diffusion step.\n- **LM:** Replaces the inner gradient-descent optimizer with a Levenberg–Marquardt solver, retaining the same objective and correction location.\n- **$\\Pi$GDM:** Replaces clean-residual editing with diffusion posterior guidance, propagating the scene constraint through the reverse process and applying the guidance increment to the noisy-state update.\n\nAll three methods share the same implementation framework and automatic-differentiation backend. Their respective inner iterations, step sizes, damping factors, guidance strengths, and covariance scales are independently tuned.\n\n| Method | Sampling time ↓ (ms/frame) | Relative time | Mean penetration depth ↓ (mm) |\n|---|---:|---:|---:|\n| LM correction | 67.76 | 2.50× | **0.010** |\n| $\\Pi$GDM scene guidance | 37.39 | 1.38× | 4.704 |\n| Ours | **27.09** | **1.00×** | 0.335 |\n\nAll results are measured on the same GPU under the same sampling schedule and scene configuration. Sampling time includes condition preparation, denoising, scene correction, and final projection, but excludes the Predictor. Penetration depth is averaged over valid capsule–box pairs.\n\n**LM achieves the lowest penetration depth but at substantially higher computational cost.** It further reduces the mean penetration depth by 0.325 mm compared with ours, while requiring 2.50× the sampling time. Its repeated Jacobian construction and damped linear solves at every denoising step introduce considerable overhead, making the sampler alone exceed the per-frame budget; the actual end-to-end latency is higher because Predictor time is excluded.\n\n**$\\Pi$GDM is both slower and less effective in this few-step setting.** Unlike our approach, which edits the predicted clean residual before the DDIM update, $\\Pi$GDM applies its guidance to the noisy state after the update. Each correction is therefore partly re-noised by the following step, with limited opportunities for recovery under a short sampling schedule. Moreover, computing the pseudo-inverse requires differentiation through the denoiser, whereas our correction only differentiates through forward kinematics and the SDF lookup.\n\nOverall, these results show that directly correcting the predicted clean residual **offers a more favorable trade-off between scene consistency and computational efficiency** for real-time, few-step motion tracking.\n\n**Q2: Clarification of the pipeline illustration in Fig. 2**\n\nWe thank the reviewer for this helpful suggestion. Fig. 2 is organized into three parts. The left part shows (a) the Predictor followed by (b) the Kinematic-Consistency Confidence Estimator, which operate sequentially. The middle part illustrates two consecutive DiT denoising steps, with red and blue indicating steps \\(T\\) and \\(T-1\\), respectively. **Each denoising step includes (d) the M-step Posterior Correction**, which is shown separately on the right for clarity. **The output of each posterior correction is fed into the subsequent denoising step**. We have added number in the Fig. 2 to make this organization and iterative data flow clearer. The revised Fig. 2 is added to the supplementary materials.",
+ "title": "Thank you for your valuable feedbacks.(Q1&Q2)"
+ },
+ "createdAt": "2026-11-15T06:21:11.233Z",
+ "modifiedAt": "2026-11-15T06:21:48.554Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=HzHU8fPrxW",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/igpko9u3mx.json added

+++ b/reviews/openreview/b32kixkt6j/notes/igpko9u3mx.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "igpkO9U3MX",
+ "replyTo": "yjrBb4LVz1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you for your valuable feedbacks.(Q5)",
+ "comment": "**Q5: Notation and Undefined Operators**\n\nWe thank the reviewer for highlighting these readability issues. We have systematically revised the notation throughout the manuscript and appendix.\n\n**Undefined operators**. In Eqs. (11) and (12), $\\operatorname{slerp}$ denotes **spherical linear interpolation** between rotations, implemented using **scipy.spatial.transform.Slerp**, while $\\operatorname{clip}$ denotes **elementwise value clamping**, implemented using **torch.Tensor.clamp**. Both operators and their associated parameters are now explicitly defined in the revised manuscript.\n\n**Notation consistency**. We have made the following changes to eliminate ambiguity:\n\n1. Renamed the confidence-controlled correction amplitude from $m_n^j$ and $\\mathbf{m}_n$ to $g_n^j$ and $\\mathbf{g}_n$, distinguishing them from the historical frame index $m$.\n\n2. Replaced the posterior-correction iteration indices $(m)$ and $(m+1)$ with $(i)$ and $(i+1)$, while retaining $M$ for the total number of iterations.\n\n3. Renamed the token representations $\\mathbf{Z}^{\\mathrm{m}}$ and $\\mathbf{Z}^{\\mathrm{s}}$ to $\\mathbf{Z}^{\\mathrm{motion}}$ and $\\mathbf{Z}^{\\mathrm{tracker}}$, respectively.\n\nAll corresponding equations and references have been updated consistently throughout the manuscript and appendix."
+ },
+ "createdAt": "2026-11-18T03:42:12.432Z",
+ "modifiedAt": "2026-11-18T03:42:12.432Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=igpkO9U3MX",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/kqgmggrmdh.json added

+++ b/reviews/openreview/b32kixkt6j/notes/kqgmggrmdh.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "kqgmGgrmDh",
+ "replyTo": "DMNKoVY4DI",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer hADe",
+ "content": {
+ "comment": "Thank you for the detailed response. I now have a clearer understanding of what the AUJ metric measures and the advantages of using confidence scores over binary availability masks. I also appreciate the expanded experiments on scene consistency; these additions certainly strengthen the paper. However, I still have lingering concerns regarding the novelty and impact of the kinematics-based confidence, which I consider to be the most distinguishing aspect of this work. For now, I will maintain my current score and look forward to participating in the reviewer discussion."
+ },
+ "createdAt": "2026-11-18T04:47:31.942Z",
+ "modifiedAt": "2026-11-18T04:47:31.942Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=kqgmGgrmDh",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/mpqmcsbbup.json added

+++ b/reviews/openreview/b32kixkt6j/notes/mpqmcsbbup.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "MpQmcsbBup",
+ "replyTo": "qy1e6LQ6ed",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you for your valuable feedbacks. (Q5)",
+ "comment": "**Q5: Kinematics-based confidence vs. learned probabilistic uncertainty**\n\nWe thank the reviewer for this insightful suggestion. STANCE targets motion tracking and reconstruction, where **faithfully following user-provided observations is essential**. This differs from motion generation (e.g., MaskedMimic), where **tracker inputs can serve as flexible guidance toward plausible motions**. Learned uncertainty based primarily on a motion prior may **favor prior-plausible motions over valid but less common user inputs**. In contrast, STANCE first uses the motion prior to predict a reference pose, then **assesses observation reliability through kinematic consistency**. This allows us to selectively correct unreliable measurements while preserving reliable user inputs. Our ablation results in Q2 further demonstrate the benefit of continuous kinematics-based confidence over binary availability masks."
+ },
+ "createdAt": "2026-11-15T01:27:03.584Z",
+ "modifiedAt": "2026-11-15T01:27:03.584Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=MpQmcsbBup",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/qy1e6lq6ed.json added

+++ b/reviews/openreview/b32kixkt6j/notes/qy1e6lq6ed.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "qy1e6LQ6ed",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer hADe",
+ "content": {
+ "paper_summary": "This paper proposes a framework to estimate full-body motion from a varying set of sparse trackers. To this end, a temporal predictor first generate a full-body motion prior using only fixed core trackers. Then per-joint confidence weights are determined from the gap between the motion prior and IK solution. A residual diffusion transformer refines the prior conditioned on the confidence-gated features. During diffusion inference, a posterior correction optimizes the denoised pose residual by using SDF of the scene to remove penetration.",
+ "presentation": 3,
+ "informativeness": 1,
+ "soundness": 3,
+ "critical_strengths": "The strategy to support varying number of trackers without training networks for each case is practical for VR applications where tracker failure occurs often. Addressing abrupt transitions and snapping artifacts due to tracker dropout and reconnection also raises the practicality of the framework. The adoption of single-frame residual denoising rather than multi-frame trajectory generation keeps the diffusion sampling relatively compact. Overall, the framework is well-motivated for real-time applications.",
+ "critical_weaknesses": "- The overall pipeline is largely an engineering integration of known components, such as single-frame residual DiT and test-time Diffusion Posterior Sampling. I could not find conceptually novel aspect from the framework.\n\n- Confidence is a distinguishing factor of this work, but the way it determine confidence is rather hueristic. I wonder how the method will improve if it used a learned probabilistic uncertainty as confidence rather than kinematic distance.\n\n- Scene consistency is highlighted in the text, but the way it solves for scene consistency does not seem novel. In addition, it has been validated only for a very limited case.",
+ "questions_for_authors": "- How does the proposed confidence compare empirically agains simple binary availability mask? As the authors argues that simple binary mask approach is limiting, such comparion would be necessary.\n\n- Please clarify why the Area Under Jerk during tracker loss is substantially higher than RPM baselines. Wouldn't this lead to visible sluggishness or floating artifacts during sudden dropouts?",
+ "flag_for_ethics_review": "No",
+ "rating": 2,
+ "confidence": 3
+ },
+ "createdAt": "2026-10-22T11:38:26.401Z",
+ "modifiedAt": "2026-11-06T12:20:52.655Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=qy1e6LQ6ed",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/ryvslfujzy.json added

+++ b/reviews/openreview/b32kixkt6j/notes/ryvslfujzy.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "RyVsLfUjzy",
+ "replyTo": "yjrBb4LVz1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you for your valuable feedbacks.(Q6)",
+ "comment": "**Q6: Broader Evaluation of Scene Consistency**\n\nWe thank the reviewer for this constructive suggestion. We agree that scene consistency, as a core contribution of STANCE, deserves broader evaluation beyond the single-sequence visualization in Fig. 5.\n\n**1. Scope of Scene Consistency.** In STANCE, scene consistency refers to reducing body-scene penetration while maintaining geometrically plausible body-scene interactions during motion. \n\n**2. Additional Scenarios and Quantitative Evaluation.** To address this concern, we have added two complementary scenarios: (1) sitting on a chair, involving coupled contacts between the back and thighs and the chair's backrest and seat; and (2) leaning against a wall, testing horizontal non-penetration constraints. Together with the original armrest-tapping scenario, which captures dynamic, localized contact, these cover diverse interaction configurations and scene geometries.\n\nWe further quantify scene consistency using three mutually exclusive frame-level metrics. Over manually verified frames in which contact is expected, each frame is classified according to the minimum signed distance of the evaluated body region as Penetration ($s_{\\min}<-\\varepsilon$), Contact Preservation ($-\\varepsilon\\leq s_{\\min}\\leq\\delta$), or Separation ($s_{\\min}>\\delta$), with $\\varepsilon=1$ mm and $\\delta=5$ mm. The three ratios sum to 100%, and both methods use identical frame sets within each scenario. We additionally report mean penetration depth over violating frames to distinguish penetration severity from its frequency.\n\n| Scene / Region | Method | Penetration ↓ | Contact ↑ | Separation ↓ | MeanDepth ↓ (mm) |\n| ------------------ | ------------------ | ------------- | --------- | ------------ | ---------------- |\n| Armrest / Left arm | Without correction | 45.79% | 26.64% | 27.57% | 5.51 |\n| | STANCE | 0.00% | 55.14% | 44.86% | 0.00 |\n| Chair / Back | Without correction | 99.43% | 0.57% | 0.00% | 12.91 |\n| | STANCE | 19.54% | 39.66% | 40.80% | 2.69 |\n| Chair / Thighs | Without correction | 100.00% | 0.00% | 0.00% | 29.21 |\n| | STANCE | 42.59% | 57.41% | 0.00% | 1.90 |\n| Wall / Back | Without correction | 100.00% | 0.00% | 0.00% | 35.31 |\n| | STANCE | 75.44% | 24.56% | 0.00% | 4.42 |\n\nPenetration decreases and contact preservation increases in all four evaluated regions. The remaining penetration is substantially shallower, as the correction performs a fixed number of gradient steps within each denoising step, reducing deep violations without necessarily eliminating every violation. Separation in the armrest and chair-back scenarios also corresponds to physically reasonable postures: the arm naturally moves away from the armrest between taps, while the backrest provides only horizontal support and the seat continues to support the body's weight.\n\nAll three scenarios use the same checkpoint, without scene-specific training or weight updates. **Qualitative demonstrations of all three scenarios are provided in the supplementary material, with visualizations shown in Appendix Fig. 8**.\n\n**3. Scene Transfer Without Retraining.** We would like to clarify the distinction between **generalization across motion datasets** and **adaptation to different scene geometries**. The former concerns motion reconstruction performance, for which Tables 1–3 demonstrate STANCE's superior performance against state-of-the-art baselines **under the cross-dataset A-P2 evaluation protocol mentioned in Sec.4.1**. The latter concerns the ability of the proposed scene-consistency correction to handle different environments, which is more directly evaluated using diverse scene geometries described above.\n\nImportantly, STANCE achieves scene consistency through **training-free posterior correction rather than scene-specific learning**. The correction module has no learned scene-dependent parameters: it queries the signed distance field $s$ and its gradient $\\nabla s$ at body sample points (Eq. 15). Consequently, changing the environment only requires providing the corresponding scene geometry, without retraining or fine-tuning the model. To evaluate this capability directly, the three scenarios above were newly **captured in our laboratory and are not included in either the training or test sets** of the motion dataset. They involve distinct scene geometries and interaction configurations, yet all use the same checkpoint without scene-specific adaptation."
+ },
+ "createdAt": "2026-11-18T03:42:37.512Z",
+ "modifiedAt": "2026-11-18T03:42:37.512Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=RyVsLfUjzy",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/sga2bqdziz.json added

+++ b/reviews/openreview/b32kixkt6j/notes/sga2bqdziz.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "sGA2Bqdziz",
+ "replyTo": "YmSFFBAvZt",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you for your valuable feedbacks.(Q4)",
+ "comment": "**Q4: FABRIK and Its Relation to the Posterior Correction**\n\nWe thank the reviewer for raising this important question.\n\n**1. Role of FABRIK in STANCE.** Yes, FABRIK refers to the Forward And Backward Reaching Inverse Kinematics algorithm proposed by Aristidou and Lasenby (2011), and its full name and original reference have been added to the revised manuscript. In STANCE, FABRIK performs the partial IK solve described in Sec. 3.3. Importantly, **its output is an intermediate measurement representation** rather than the final rendered pose. It propagates tracker observations through the skeleton so that the distance between each solved endpoint and its corresponding tracker target can be computed. These distances are then used to estimate per-joint confidence and provide conditioning information to the denoiser.\n\n**2. Why FABRIK is not used for penetration correction.** We do not use FABRIK for penetration correction because scene penetration is not an endpoint-target problem. It can involve **multiple body regions interacting simultaneously with surfaces of different orientations**. For example, in the additional chair-sitting experiment included in the supplementary material, the back and thighs simultaneously interact with the chair's backrest and seat, respectively. Handling such interactions with FABRIK would require specifying and coordinating multiple contact targets, whose independent solutions could conflict and distort other body configurations.\nOur posterior correction instead **treats scene geometry as a soft constraint**: Eq. (15) penalizes penetration rather than projecting contact points to prescribed locations, allowing penetration constraints from multiple body regions to be jointly optimized within a unified objective. Eq. (16) then **optimizes this penalty jointly with motion fidelity** at each reverse diffusion step. Subsequent denoising steps continue to refine the corrected motion under the learned motion prior, rather than relying on a separate terminal IK projection.\n\n**3. Joint Constraints.** Although the original FABRIK algorithm supports joint limits, we do not explicitly enable them in our implementation. This is because the solve is **initialized from the prior prediction**, $\\mathrm{IK}(\\bar{\\mathbf{x}}_n,\\mathbf{p}^{k}_n)$ in Sec. 3.3, rather than from an arbitrary configuration. More importantly, its output is an intermediate measurement used for confidence estimation and denoiser conditioning, not the final rendered pose. We therefore rely on the prior initialization and subsequent motion reconstruction rather than explicitly imposing joint-angle limits in this auxiliary solve.\n\nSimilarly, the posterior correction does not impose hard joint-angle limits. Instead, **joint plausibility is encouraged by the learned motion prior and maintained through the motion-fidelity term** in Eq. (16), confidence-weighted updates, and subsequent denoising steps. These mechanisms discourage large deviations from the predicted motion but do not guarantee that every joint angle remains within predefined anatomical limits. We will clarify this distinction in the revised manuscript."
+ },
+ "createdAt": "2026-11-16T08:14:11.383Z",
+ "modifiedAt": "2026-11-16T08:19:02.773Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=sGA2Bqdziz",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/teqnolshbb.json added

+++ b/reviews/openreview/b32kixkt6j/notes/teqnolshbb.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "TEqnoLsHbB",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer Cn7B",
+ "content": {
+ "paper_summary": "This paper tackles the problem of estimating full-body pose from sparsely placed 6DoF trackers in the presence of 3D scene geometry that constrains the human pose. The authors use a Diffusion framework to solve this problem. Unlike traditional diffusion-based pose estimation algorithms, the authors first predict a rough pose sequence using a neural network prior. The diffusion model is then used to refine the original prediction, guided by the scene geometry and other posterior-refinement losses.\n\nThe prior neural network model assumes that three trackers are always present: the head and the wrists. The sparse 6Dof signals from these three trackers are fed directly into the prior model to produce the initial pose sequence. The predicted poses are then individually corrected using a posterior-guided diffusion framework. One of the guidance terms is the presence of other trackers that are used opportunistically when available. This correction is performed using an Inverse-Kinematic guidance signal that refines the prior pose predictions within the sequence, one by one. To allow for opportunistic tracker signal dropouts without causing discontinuous transitions, the authors propose a slerp-based pose interpolation algorithm.\n\nTo incorporate scene geometry constraints, a signed distance field of the scene is first constructed in advance. During inference, if the predicted pose mesh intersects the scene geometry, an additional posterior guidance signal is used to modify the pose so that the mesh is pushed away from the geometry it intersects. This removes the need for any training-based method for incorporating the scene.\n\nThe proposed method compares favorably with other baselines in real-world datasets.",
+ "presentation": 2,
+ "informativeness": 2,
+ "soundness": 3,
+ "critical_strengths": "The authors propose a new SoTA technique for full-body pose estimation using sparse 6DOF sensors. Their technique manages to beat existing baselines with a neural network that runs with comparable latency to existing works.\n\nSecondly, the authors propose a training-free strategy to account for 3D scene geometry. Unlike prior works that require encoding the scene using a trained model, this training-free strategy can be applied at inference time to any previously unseen 3D scenes to prevent generated pose meshes from penetrating the scene geometry.",
+ "critical_weaknesses": "The main weakness, in my opinion, is the lack of comparison between the opportunistic tracker incorporation mechanism proposed in the paper, and existing techniques in the literature. The authors propose using a PostEdit[1] style guidance mechanism. But there have been previously proposed guidance mechanisms such as EgoAllo[2], which uses a Levenberg-Marquardt solver to opportunistically incorporate tracking signals, and InPose[3], which uses a $\\Pi$-GDM-Based diffusion inverse guidance mechanism.\n\nA minor weakness is the pipeline explanation in Figure 2, which is hard to follow and doesn't show the numbering used in the labels.\n\n[1] Feng Tian, Yixuan Li, Yichao Yan, Shanyan Guan, Yanhao Ge, and Xiaokang Yang. Postedit: Posterior sampling for efficient zero-shot image editing. In the International Conference on Learning Representations, 2025.\n\n[2] Brent Yi, Vickie Ye, Maya Zheng, Yunqi Li, Lea Müller, Georgios Pavlakos, Yi Ma, Jitendra Malik and Angjoo Kanazawa. Estimating Body and Hand Motion in an Ego-sensed World. In CVPR 2025.\n\n[3] Sahil Bhandary Karnoor and Romit Roy Choudhury. Zero-shot Human Pose Estimation using Diffusion-based Inverse Solvers. In the International Conference on Learning Representations, 2026.",
+ "questions_for_authors": "See weaknesses.\n\nOne question is whether the authors can pull the pose mesh towards the scene geometry to prevent the mesh from floating in space. This has previously been achieved using physics-based pose generation methods such as MaskedMimic [1].\n\n[1] Chen Tessler, Yunrong Guo, Ofir Nabati, Gal Chechik and Xue Bin Peng. MaskedMimic: Unified Physics-Based Character Control Through Masked Motion Inpainting. In SIGGRAPH Asia 2024.",
+ "flag_for_ethics_review": "No",
+ "rating": 3,
+ "confidence": 4
+ },
+ "createdAt": "2026-10-21T06:26:24.123Z",
+ "modifiedAt": "2026-11-06T12:20:53.996Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=TEqnoLsHbB",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/um9jvszdhb.json added

+++ b/reviews/openreview/b32kixkt6j/notes/um9jvszdhb.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Um9jvSzdhb",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal summary for the Reviewers and Area Chair.",
+ "comment": "We thank all reviewers for their careful reading and the Area Chair for overseeing the discussion. Our responses address every point raised; here we summarise what we take to be the substance of the paper and the evidence added during the discussion. All additions appear in the revised manuscript.\n\n**What is distinctive.** STANCE is a predict-confidence-correct framework for real-time reconstruction from sparse trackers whose configuration and reliability change at runtime. Its components are coupled, not independently assembled: the predictor gives the residual's reference pose; confidence defines the gated training target, conditions the denoiser, and gates the posterior correction; and a shared residual space anchors scene guidance to the denoiser's estimate. This integration enables two capabilities that, to our knowledge, no prior sparse-tracker method supports jointly. First, one set of weights handles tracker configurations that change within a session, at SOTA accuracy with 3 and 6 trackers and fixed per-frame cost. Second, scene constraints are enforced with no scene seen in training, so the room may change without retraining or a learned collision model. **Together they suit collecting embodied-interaction data**, where a demo whose hand passes through the object it grasps teaches an agent nothing. **Both are illustrated in the supplementary demos.**\n\n**Confidence from kinematic consistency.** A binary mask indicates tracker presence, not measurement reliability. We derive continuous per-joint confidence from the discrepancy between tracker targets and kinematically constrained IK solutions, enabling reliability-aware correction; to our knowledge, prior sparse-tracker methods primarily rely on binary availability. **We addressed this in Q6 for Reviewer hADe, who maintained the concern.** A matched-condition ablation compares continuous confidence against binary availability, all else fixed, and shows improvements in every metric under both configurations: MPJPE from 5.58 to 5.31 cm and MPJVE from 21.92 to 21.23 cm/s under 3 trackers, and from 1.16 to 1.07 cm and 8.41 to 8.29 cm/s under 6.\n\n**Scene consistency without training.** Beyond the armrest sequence of Fig. 5 we added two scenarios (Fig. 8, appendix): sitting on a chair, with coupled contact across a backrest and seat in different planes, and leaning against a wall, a horizontal constraint with no support. Over manually verified contact frames in the 4 regions we report 3 mutually exclusive frame-level metrics plus mean penetration depth, separating severity from frequency. Penetration frames fall and contact frames rise in every region, with mean depth dropping from 5.51-35.31 mm to 0.00-4.42 mm, all on one checkpoint with no scene-specific training or weight updates. Measured in our laboratory, these scenarios show that **a training-free correction transfers to geometry the model never saw**, though they are not a large-scale benchmark, which does not exist for sparse-tracker capture. Where the correction acts also matters: against a Levenberg-Marquardt optimizer (EgoAllo lineage) and a ΠGDM-based mechanism (InPose lineage), everything else held fixed, we sample at 27.09 ms/frame against 67.76 ms (2.50×) and 37.39 ms (1.38×), at 0.335 mm mean depth against 0.010 and 4.704 mm. LM's additional 0.325 mm reduction comes at 2.50× the sampling cost, while ΠGDM corrects the noisy state after the DDIM update and is partly re-noised at each step. Both comparisons are in the revised appendix.\n\n**Interpreting the dropout AUJ.** AUJ accumulates the frame-wise absolute difference from ground-truth jerk, registering deviation in high-order dynamics, not roughness; jitter, our smoothness metric, is the lowest in Tab. 1. All AUJ contributions arise from frames whose predicted jerk is below ground truth, and we evaluated the half second after each of 702 dropout events in the 138 A-P2 sequences. Despite a higher AUJ, STANCE keeps the largest fraction of ground-truth wrist speed (0.853 vs 0.795 and 0.831), the lowest wrist error (12.25 cm vs 16.14 and 16.54), and the least foot sliding (17.02 cm/s vs 21.84 and 22.85). A plausible explanation is that it preserves the dominant wrist trajectory while attenuating small-amplitude, high-frequency secondary motions, so a higher AUJ need not imply poorer trajectory fidelity.\n\n**Presentation.** The notation problems raised are now resolved throughout: no symbol serves as both gate and frame index, the inner iterations of the correction carry their own index, token matrices are labelled by type, slerp, clip, $y_\\mathrm{floor}$ and both loss terms are defined, FABRIK is cited, and Fig. 2 is redrawn with numbered stages. We are grateful these were pointed out; they concern how the method is described rather than what it does.\n\nWe welcome any remaining questions in the final hours. If the revised manuscript and the added evidence address your concerns, we would be grateful if you would reconsider your assessments."
+ },
+ "createdAt": "2026-11-19T07:49:08.829Z",
+ "modifiedAt": "2026-11-19T10:02:44.134Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=Um9jvSzdhb",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/uowulcfixo.json added

+++ b/reviews/openreview/b32kixkt6j/notes/uowulcfixo.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "uoWuLcfIXO",
+ "replyTo": "GrtSd3RE3S",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Looking forward to your improving the final score in the system.",
+ "comment": "Dear Reviewer dJdg,\n\nThank you for your efforts and valuable comments on improving the quality of our manuscript. We kindly remind that the discussion time is coming to an end. We are also glad to hear that you are willing to raise the score, and we look forward to your editing the final score in the system. Thank you again for your efforts and please feel free to contact us if you have any further questions.\n\nBest regards,\n\nThe Authors of STANCE"
+ },
+ "createdAt": "2026-11-18T07:13:31.783Z",
+ "modifiedAt": "2026-11-18T07:13:31.783Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=uoWuLcfIXO",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/vf3pxsjafh.json added

+++ b/reviews/openreview/b32kixkt6j/notes/vf3pxsjafh.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "vF3pxsJafh",
+ "replyTo": "GrtSd3RE3S",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you for your valuable feedbacks.(Notice1&Q1)",
+ "comment": "We thank reviewer dJdg for the careful reading and for pointing out several aspects that require clarification. \n\n**Notice 1: Fundamental Clarification of the Input Modality**\n\nWe would first like to clarify a fundamental misunderstanding in the review: STANCE does not use IMU signals at all. It operates exclusively on body-worn position trackers that provide positional observations, not inertial measurements. The three compulsory and three optional sensors described in the paper are all position trackers, with the optional trackers potentially becoming unavailable during motion. This distinction is fundamental, not merely terminological: IMU-based motion reconstruction relies on inertial signals, whereas STANCE addresses motion reconstruction from sparse and intermittently missing positional observations. Consequently, characterizing our work as IMU-based HMR misrepresents the input modality, the underlying problem setting, and the technical motivation of the proposed method. We respectfully ask that this distinction be taken into account when evaluating the paper.\n\n**Q1: Organization of Mathematical Symbols**\n\n**Clarifications of Existing Notation.** The three sensor symbols represent successive levels of the same data pipeline, rather than three names for the same quantity. Specifically, $s^k_n$ denotes the raw measurement from tracker $k$ at frame $n$ (Eq. 2). $u^k_m$ denotes the single-frame encoding derived from this measurement for the Predictor, incorporating frame-to-frame rotation and displacement (Eq. 4). $S^c_m$ concatenates these encodings across the three core trackers at frame $m$, and the Predictor takes the window $S^c_{n-L:n}$ as input. Thus, these symbols represent three successive levels of the same data pipeline, from an individual tracker's raw measurement to its per-frame encoding and finally to the Predictor's windowed input.\n\nThe two time indices also have distinct meanings: $n$ denotes the current frame being estimated, whereas $m$ indexes individual frames within the input window $n-L,\\ldots,n$. This separate index is necessary because the encoding involves frame-to-frame differences at each position in the window, rather than only at the current frame.\n\n**Corrections in the Revised Manuscript.** We acknowledge that reusing $H$ for the prediction horizon and token matrices could cause ambiguity, as they were distinguished only by boldface. We have therefore renamed the token matrices as $\\mathbf{Z}^{s}$, $\\mathbf{Z}^{m}$, and $\\mathbf{Z}$, reserving $H$ exclusively for the prediction horizon.\n\nWe have also corrected Eq. (5) and the corresponding denoiser conditioning in Sec. 3.4. Throughout the paper, $\\mathbf{x}$ denotes the ground-truth pose, $\\bar{\\mathbf{x}}$ denotes the Predictor's prior prediction, and $\\hat{\\mathbf{x}}=\\bar{\\mathbf{x}}+\\hat{\\mathbf{r}}$ denotes the reconstructed pose after residual refinement. Therefore, the historical input should consist of reconstructed poses, and Eq. (5) should use $\\hat{\\mathbf{x}}\\_{n-L:n-1}$ instead of $\\mathbf{x}\\_{n-L:n-1}$. Accordingly, the denoiser conditioning in Sec. 3.4 is corrected to $(\\hat{\\mathbf{x}}\\_{n-L:n-1},\\bar{\\mathbf{x}}\\_{n:n+H})$."
+ },
+ "createdAt": "2026-11-15T15:25:54.149Z",
+ "modifiedAt": "2026-11-15T15:25:54.149Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=vF3pxsJafh",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/yhdspxa3ni.json added

+++ b/reviews/openreview/b32kixkt6j/notes/yhdspxa3ni.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "YHDSPxA3ni",
+ "replyTo": "GrtSd3RE3S",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you for your valuable feedbacks.(Q2&Q3&Q4)",
+ "comment": "**Q2: Missing details**\n\n$y_{\\mathrm{floor}}$ is the height of the floor plane in the world frame and is a session constant rather than a per-frame quantity. In the live system it comes from the headset's room calibration, which places the floor at zero; on AMASS it is read from the capture. It enters only the origin of the local frame $F_{n}$ in Eq. (3), so what matters is that the same convention holds at training and at deployment, which calibration guarantees.\n\nFABRIK is Forward And Backward Reaching Inverse Kinematics (Aristidou & Lasenby, 2011), a classical and widely used IK solver whose name we had taken to be common knowledge and therefore left unexpanded, which we agree is not appropriate for a general audience. The reference will be given in the revised paper.\n\nThe solve does use bone lengths, and they are an input rather than a quantity we estimate: on AMASS the per-sequence rest skeleton supplied with the dataset, and in the live system the calibrated avatar skeleton of the session. No limb length is inferred from the tracker readings, so the solve has nothing subject-specific to estimate at run time.\n\n**Q3: Definition of the Geometric Loss**\n\nWe have now explicitly defined both terms. $\\mathcal{L}\\_{\\mathrm{res}}$ uses an MSE loss to measure the error between the confidence-gated target residual and the residual predicted by the denoiser, aggregated over all joints. $\\mathcal{L}\\_{\\mathrm{geo}}$ is a weighted combination of position MSE, squared rotational-angle error, Huber loss, and cosine loss, evaluated on the reconstructed pose $\\bar{\\mathbf{x}}\\_n+\\hat{\\mathbf{r}}\\_n$ against the ground-truth pose $\\mathbf{x}\\_n$. The two terms provide complementary supervision: $\\mathcal{L}\\_{\\mathrm{res}}$ supervises pose residuals, while $\\mathcal{L}\\_{\\mathrm{geo}}$ explicitly constrains the geometric and rotational consistency of the reconstructed motion. The full set of components and their weights is given in the revised appendix.\n\n**Q4: Construction of the Prior Scene and Fairness**\n\nThe scene is authored rather than estimated. We reconstruct the real furniture geometry from photographs and dimensional references, place it in Unity, and attach collision proxies whose signed distance fields (SDFs) provide the distance and gradient queried by the correction module. This design matches our target application: when motion is replayed in a virtual room, the room geometry is already available as part of the environment, making it an input rather than something that must be recovered from head observations. Estimating unknown scene geometry is a separate problem and is outside the scope of this work.\n\nImportantly, our main quantitative comparisons **do not give STANCE access to scene information unavailable to other methods**. The evaluations in Tables 1–3 use AMASS under the A-P2 protocol, where no scene geometry is involved and the scene correction module is inactive. Thus, **all reported accuracy, velocity, and jitter results are obtained using the same input information available to the baselines**. **Scene geometry is introduced only in the additional scene-consistency evaluation**, where we compare STANCE with and without posterior correction under the same scene conditions. We therefore present scene consistency as an additional capability of STANCE, rather than as an advantage in the main benchmark comparisons."
+ },
+ "createdAt": "2026-11-16T06:00:32.632Z",
+ "modifiedAt": "2026-11-16T06:00:43.600Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=YHDSPxA3ni",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/yjrbb4lvz1.json added

+++ b/reviews/openreview/b32kixkt6j/notes/yjrbb4lvz1.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "yjrBb4LVz1",
+ "replyTo": "YHDSPxA3ni",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer dJdg",
+ "content": {
+ "title": "Follow-up review",
+ "comment": "I appreciate the authors' detailed explanations of the unclear parts. I sincerely apologize for my careless misuse of the terms IMU-based and tracker-based HMR. Apart from the difference in input modalities, I am fully aware that the main research problem is to tackle intermittently missing observations from optional trackers while maintaining the core tracker observations. I believe the proposed confidence module and scene-consistency correction are well motivated, and the visualization indeed shows that the posterior correction can reduce scene penetration. However, my core concerns remain the readability of the methodology. The sufficiency of the experimental evaluation also becomes an issue:\n\n1. Apart from the mathematical notation issues I mentioned earlier, there are still many confusing symbols and insufficiently explained operations in the equations that make the method difficult to comprehend. For example, slerp(·) and clip(·) are not explained in Eqs. (11) and (12); m_n represents the confidence-controlled correction amplitude, while (m) is also used as a frame index; Z^m represents the zero-padded motion tokens from tracker tokens Z^s. In Eq. (16), the superscript (m) in (\\hat r_n^{(m)}) instead represents an inner posterior-correction iteration, reusing the same symbol (m) for a different purpose. The organization of mathematical symbols is a major readability issue. \n\n\n2. I appreciate the clarification that Tables 1–3 do not use scene information, which addresses my original fairness concern regarding these comparisons. However, scene consistency is presented as a core contribution in the title and introduction, while Tables 1–3 do not evaluate this component. Meanwhile, Figure 5 only reports penetration depth for a single sequence. Although the visualization results appear effective, this is still insufficient to verify whether the proposed method can generalize to broader datasets or scene geometries."
+ },
+ "createdAt": "2026-11-17T10:45:18.088Z",
+ "modifiedAt": "2026-11-17T10:45:18.088Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=yjrBb4LVz1",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/ymsffbavzt.json added

+++ b/reviews/openreview/b32kixkt6j/notes/ymsffbavzt.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "YmSFFBAvZt",
+ "replyTo": "5BpTthIasR",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer Cn7B",
+ "content": {
+ "comment": "I thank the authors for their detailed response to my questions. I still have one question regarding their partial inverse-kinematics solver, FABRIK, that reviewer dJdg raised. I assumed it was the same technique as the inverse guidance mechanism that was used for geometry penetration removal. \n\nSince this doesn't seem to be the case, can the authors elaborate on what FABRIK is? Is it the \"FABRIK: A fast, iterative solver for the Inverse Kinematics problem\" algorithm by Andreas Aristidou and Joan Lasenby? Why not use this algorithm to solve for geometry penetration, since both fundamentally solve the same partial inverse kinematics problem?\n\nFurthermore, are body joint constraints respected by the inverse guidance mechanisms and by FABRIK? Do they affect joint angles in such a way that a joint could exceed the joint limits defined by the prior?"
+ },
+ "createdAt": "2026-11-16T05:56:24.179Z",
+ "modifiedAt": "2026-11-16T06:05:29.997Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=YmSFFBAvZt",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/zokujbarmj.json added

+++ b/reviews/openreview/b32kixkt6j/notes/zokujbarmj.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "zokUjBarMJ",
+ "replyTo": "GrtSd3RE3S",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer dJdg,\n\nThank you again for the great efforts and valuable comments. We hope you find the response satisfactory. As the discussion phase is about to close, we are eagerly looking forward to hearing from you regarding any further feedback. We will be more than happy to address any additional concerns you may have.\n\nBest,\n\nSTANCE Authors"
+ },
+ "createdAt": "2026-11-17T08:35:44.747Z",
+ "modifiedAt": "2026-11-17T08:35:44.747Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=zokUjBarMJ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/notes/zrb0twmhdu.json added

+++ b/reviews/openreview/b32kixkt6j/notes/zrb0twmhdu.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "zrb0twMHdu",
+ "replyTo": "fx5xUCgd2q",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you for your valuable feedbacks. (Q3&Q4)",
+ "comment": "**Q3: On the limited validation of scene consistency**\n\nWe thank the reviewer for this suggestion. We have added two complementary scenarios: (1) sitting on a chair, **involving coupled contacts** with the backrest and seat across different planes; and (2) leaning against a wall, **testing horizontal non-penetration constraints**. Together with the original armrest-tapping scenario, which captures **dynamic, localized contact**, these cover diverse scene interactions.\n\nWe further quantify scene consistency using **three mutually exclusive frame-level metrics**. Over the manually verified frames in which contact is expected, each frame is classified by the minimum signed distance of the region as Penetration ($<-\\varepsilon$), Contact Preservation ($-\\varepsilon$ to $\\delta$), or Separation ($>\\delta$), with $\\delta=5$ mm and $\\varepsilon=$ 1 mm. **The three sum to 100%**, and the frame set is identical for both rows of each scenario. We also report the mean penetration depth over violating frames, so that severity is reported separately from frequency.\n\n| Scene / Region | Method | Penetration ↓ | Contact ↑ | Separation ↓ | MeanDepth ↓ (mm) |\n| ------------------ | ------------------ | ------------- | --------- | ------------ | ---------------- |\n| Armrest / Left arm | Without correction | 45.79% | 26.64% | 27.57% | 5.51 |\n| | STANCE | 0.00% | 55.14% | 44.86% | 0.00 |\n| Chair / Back | Without correction | 99.43% | 0.57% | 0.00% | 12.91 |\n| | STANCE | 19.54% | 39.66% | 40.80% | 2.69 |\n| Chair / Thighs | Without correction | 100.00% | 0.00% | 0.00% | 29.21 |\n| | STANCE | 42.59% | 57.41% | 0.00% | 1.90 |\n| Wall / Back | Without correction | 100.00% | 0.00% | 0.00% | 35.31 |\n| | STANCE | 75.44% | 24.56% | 0.00% | 4.42 |\n\n Penetration falls and contact rises in every region. The penetration that remains is shallow, since the correction takes a fixed number of gradient steps within each denoising step and therefore reduces deep violations rather than removing them. The separation it leaves in the armrest and backrest scenarios is a posture rather than floating, as the arm parts from the armrest between taps and the backrest supplies only a horizontal reaction, while the weight stays on the thighs.\n\nAll evaluations use the same checkpoint, with no scene-specific training and no weight updates. **Qualitative demonstrations of the three scenarios are provided in the supplementary material.**\n\n\n**Q4: On the higher Area Under Jerk during tracker loss**\n\nAUJ measures the cumulative frame-wise absolute difference between predicted and ground-truth jerk over the transition window, reflecting deviations in high-order motion dynamics rather than motion roughness. Jitter, our smoothness metric, is lowest for STANCE among all methods in Tab. 1 (0.96 and 1.16 under 3- and 6-point configurations, respectively). We further verified that all AUJ contributions arise from frames where the predicted mean jerk is below the ground truth, indicating attenuated rather than excessive jerk.\n\nTo assess whether this attenuation causes perceptible motion artifacts, we evaluated the 0.5s following each dropout across all 138 A-P2 test sequences (702 dropout events), measuring the speed and position of the wrist whose tracker was lost, as well as foot sliding during contact.\n\n| Method | AUJ↓ | Speed ratio to GT (→1) | Wrist err. (cm)↓ | Foot sliding (cm/s)↓ |\n|---|---:|---:|---:|---:|\n| RPM-Reactive | 11.73 | 0.795 | 16.14 | 21.84 |\n| RPM-Smooth | **6.43** | 0.831 | 16.54 | 22.85 |\n| STANCE | 22.79 | **0.853** | **12.25** | **17.02** |\n\nDespite its higher AUJ, STANCE retains the largest fraction of ground-truth wrist speed (0.853 vs. 0.795 and 0.831) and achieves the lowest wrist position error (12.25cm vs. 16.14cm and 16.54cm), **indicating less motion sluggishness**. Foot sliding during ground-truth contact frames is also lowest with STANCE (17.02cm/s vs. 21.84cm/s and 22.85cm/s), **indicating fewer foot-ground skating artifacts**.\n\nNotably, although STANCE has 3.54× the AUJ of RPM-Smooth, its wrist position error is 26% lower and its speed ratio is closer to ground truth. A plausible explanation is that **STANCE preserves the dominant wrist trajectory while attenuating small-amplitude, high-frequency secondary motions.** Such motions have limited impact on position and speed errors but can contribute substantially to AUJ due to the high-order nature of jerk. Thus, **a higher AUJ does not necessarily imply poorer trajectory fidelity.**"
+ },
+ "createdAt": "2026-11-14T13:05:16.590Z",
+ "modifiedAt": "2026-11-14T13:06:14.513Z",
+ "url": "https://openreview.net/forum?id=B32kixKT6j&noteId=zrb0twMHdu",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/b32kixkt6j/submission.json added

+++ b/reviews/openreview/b32kixkt6j/submission.json
@@ -0,0 +1,19 @@
+{
+ "schema": "submission/1",
+ "id": "B32kixKT6j",
+ "venue": {
+ "id": "ICLR.cc/2027/Conference",
+ "name": "ICLR 2027",
+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference"
+ },
+ "number": 17196,
+ "keywords": [
+ "sparse sensor",
+ "motion capture",
+ "conditional diffusion model",
+ "human-scene interaction",
+ "diffusion posterior sampling"
+ ],
+ "url": "https://openreview.net/forum?id=B32kixKT6j",
+ "license": "CC-BY-4.0"
+}

versions/v_ud7jkj3t.json added

+++ b/versions/v_ud7jkj3t.json
@@ -0,0 +1,21 @@
+{
+ "date": "2026-09-14",
+ "kind": "submitted",
+ "label": "ICLR 2027",
+ "submissions": [
+ {
+ "venue": "ICLR 2027",
+ "status": "under_review",
+ "number": 17196,
+ "url": "https://openreview.net/forum?id=B32kixKT6j",
+ "reviews": "openreview/b32kixkt6j",
+ "evidence": [
+ "https://openreview.net/forum?id=B32kixKT6j"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=B32kixKT6j",
+ "evidence": [
+ "https://openreview.net/forum?id=B32kixKT6j"
+ ]
+}