potentialpaper

Motion as Common Ground: Aligning Heterogeneous Sensing Modalities for Human Activity Recognition

Update ICLR 2027 submission NWTA24g36c: 1 note

@openreview[bot] · 2026-11-24 15:39 UTC · bcf755db9f20 ·

Evidence

reviews/openreview/nwta24g36c/notes/bmhjj2pwui.json modified

+++ b/reviews/openreview/nwta24g36c/notes/bmhjj2pwui.json
@@ -13,12 +13,12 @@
"critical_strengths": "1. The framing is a worthwhile counterpoint to the prevailing semantic-alignment approaches, and the system is well executed. Skeleton supervision for individual sensors isn't new (vision-derived poses already supervise WiFi/radar sensing), but using a structured temporal-joint space as the *common* anchor for seven heterogeneous modalities at once, with inference on arbitrary subsets, is a useful reframing; and Table 4 shows sensor features adapted into the space are directly usable by the skeleton-trained classifier, which is good evidence the sensors land in the motion space. \n2. Breadth of evaluation: seven modalities, three protocols, two datasets, arbitrary modality subsets at inference, plus a fusion module that trains 0.069M parameters vs 5.8M for X-Fi-style fusion with better accuracy. As a systems result this is thorough.",
"critical_weaknesses": "1. The comparison conflates alignment target with extra supervision. The anchor is a skeleton model fine-tuned on the HAR labels, so Stage 1 is largely distillation from a task-supervised teacher using a privileged modality the baselines never see; they align to generic semantic spaces (CLIP/ImageBind embeddings, LLM features) with no comparable teacher. The whole system therefore admits a mundane re-description, i.e. cross-modal distillation from the best available teacher, in which the motivation (physical grounding, temporal-joint structure) plays no role. The experiment that would separate the two readings (same supervision through an unstructured/pooled skeleton teacher, or skeleton distillation added to a semantic-alignment baseline) doesn't exist; Table 2 only toggles the alignment loss. \n\n2. The empirical support is weaker than the headline tables suggest: everything comes from a single training run, and the across-modality average conceals per-modality losses that contradict the uniform-SOTA story. MM-Fi margins over HoloLLM are +2.9/+2.8/+3.1, the random split is near ceiling anyway (97.5%), and per-modality results are mixed where it matters: HoloLLM wins cross-environment MM-Fi RGB by 13.7 points (80.6 vs 66.9), undiscussed, and visual modalities also trail under cross-subject. Gains concentrated on RF/geometric modalities would be a defensible finding (\"motion helps where semantics are weak\"), but the paper claims uniform SOTA via averages instead of engaging with the trade-off. With one seed and 2-3 point margins I can't rule out noise on MM-Fi.",
"questions_for_authors": "1. Can you run an anchor-structure ablation: align to a pooled/unstructured skeleton teacher (same supervision, no temporal-joint structure) vs your structured anchor? And give one semantic-alignment baseline (e.g., HoloLLM) the same skeleton distillation?\n2. Please report mean$\\pm$std over $\\geq$3 seeds for Tables 1-2, at least on the cross-subject and cross-environment protocols where margins are small.\n3. Why does UniMotion lose ~14 points to HoloLLM on RGB under cross-environment? Does motion grounding discard appearance cues that matter for vision, and if so, shouldn't the claim be scoped to RF/geometric modalities?\n4. For XRF55 the motion anchor comes from 2D poses extracted from the dataset's own RGB. Doesn't that make the RGB branch partially circular (aligning RGB features to a target derived from RGB), and how does anchor quality from pseudo-poses limit the approach?\n5. Can an anchor trained on one dataset's skeletons align the other dataset's sensors (MM-Fi anchor for XRF55, or vice versa)? Any cross-dataset result would directly test the claim that physical grounding yields a transferable common space.\n6. What enforces that joint query `j` corresponds to anatomical joint `j` for RFID/WiFi?",
"flag_for_ethics_review": "No",
- "rating": 2,
+ "rating": 3,
"confidence": 3
},
"createdAt": "2026-10-26T01:43:26.443Z",
- "modifiedAt": "2026-11-06T12:21:12.021Z",
+ "modifiedAt": "2026-11-22T19:32:25.649Z",
"url": "https://openreview.net/forum?id=NWTA24g36c&noteId=BMhJJ2pWuI",
"license": "CC-BY-4.0"
}