potentialpaper

CALIPER: EVIDENCE-CALIBRATED MULTI-EXPERT LLM PRIORS FOR MULTI-OBJECTIVE BAYESIAN OPTIMIZATION

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 19:19 UTC · 4e14c70c9a73 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "WzfsCC4ovB"
- }
- ],
- "title": "CALIPER: EVIDENCE-CALIBRATED MULTI-EXPERT LLM PRIORS FOR MULTI-OBJECTIVE BAYESIAN OPTIMIZATION",
- "authors": [],
- "abstract": "External priors can accelerate Bayesian optimization (BO) precisely when evaluation budgets are too small to recover easily from bad guidance. LLM committees make this opportunity inseparable from a reliability problem: expertise varies by objective, multiple experts may share the same bias, and stated confidence may not predict accuracy. To address this issue, we introduce Counterfactual Adaptive LLM-Integrated Prior Evidence Replay (CALIPER), a plug-in calibration layer for multi-objective BO that learns two complementary forms of trust from newly observed objectives. Relative reliability routes each objective toward the experts that predict it well; absolute reliability controls whether the committee should influence the optimizer at all. CALIPER combines objective-wise reputation, counterfactual validation of confidence, prior-amplitude control, and an explicit no-prior arm. It injects the resulting signal as a residual-GP mean shift, preserving the downstream qLogEHVI/qLogNEHVI acquisition pipeline. We evaluate every prior-control strategy with the same frozen LLM information and a locked, disjoint development/evaluation protocol on ESOL, FreeSolv, and Lipophilicity. The real-prior benchmarks show an asymmetric payoff: CALIPER captures useful guidance on ESOL and Lipophilicity while recovering the no-prior final hypervolume on FreeSolv, where unconditional injection causes negative transfer. Controlled stress tests isolate the mechanism: CALIPER gains 8.1% trajectory AUC when all experts are useful, routes objective-specialized expertise for a 6.3% gain, and stays within 0.6% of no-prior BO when every expert is misleading, compared with a 10.1% loss from fixed injection. These results establish evidence calibration as a practical interface for extracting value from uncertain external knowledge without binding the optimizer to it.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "87ff1097-b126-4e76-9c5d-7306e9a28170"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "CALIPER: EVIDENCE-CALIBRATED MULTI-EXPERT LLM PRIORS FOR MULTI-OBJECTIVE BAYESIAN OPTIMIZATION",
+ "authors": [],
+ "abstract": "External priors can accelerate Bayesian optimization (BO) precisely when evaluation budgets are too small to recover easily from bad guidance. LLM committees make this opportunity inseparable from a reliability problem: expertise varies by objective, multiple experts may share the same bias, and stated confidence may not predict accuracy. To address this issue, we introduce Counterfactual Adaptive LLM-Integrated Prior Evidence Replay (CALIPER), a plug-in calibration layer for multi-objective BO that learns two complementary forms of trust from newly observed objectives. Relative reliability routes each objective toward the experts that predict it well; absolute reliability controls whether the committee should influence the optimizer at all. CALIPER combines objective-wise reputation, counterfactual validation of confidence, prior-amplitude control, and an explicit no-prior arm. It injects the resulting signal as a residual-GP mean shift, preserving the downstream qLogEHVI/qLogNEHVI acquisition pipeline. We evaluate every prior-control strategy with the same frozen LLM information and a locked, disjoint development/evaluation protocol on ESOL, FreeSolv, and Lipophilicity. The real-prior benchmarks show an asymmetric payoff: CALIPER captures useful guidance on ESOL and Lipophilicity while recovering the no-prior final hypervolume on FreeSolv, where unconditional injection causes negative transfer. Controlled stress tests isolate the mechanism: CALIPER gains 8.1% trajectory AUC when all experts are useful, routes objective-specialized expertise for a 6.3% gain, and stays within 0.6% of no-prior BO when every expert is misleading, compared with a 10.1% loss from fixed injection. These results establish evidence calibration as a practical interface for extracting value from uncertain external knowledge without binding the optimizer to it.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}