What Artifact Tokens in Vision Transformers Are, and What They Do
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 19:21 UTC · 360a60e7ebb3 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "gptDmR0wMm"- }- ],- "title": "What Artifact Tokens in Vision Transformers Are, and What They Do",- "authors": [],- "abstract": "Vision Transformers develop a handful of high-norm ``artifact'' tokens that\noccupy low-information image regions and absorb a disproportionate share of\nattention. Register tokens were introduced to eliminate them, and a subsequent\naudit reported that the phenomenon does not generalise uniformly across\narchitectures. We present a measurement study across 15 pretrained checkpoints\nand 10 datasets spanning 9 visual domains. First, artifact formation is determined by model weights, not input statistics,\nas varying the fraction of low-information patches over a $9.1\\times$ range\nchanges artifact strength with a coefficient of variation of only\n$0.030$--$0.102$, while leaving the peak-artifact layer exactly invariant for\nevery model on every dataset, including histopathology, chest radiography, and satellite imagery. Second, the behaviour\nemerges with scale, appearing between 22M and 87M parameters on matched DINOv2\ncheckpoints. Third, register tokens work by capturing the read target. Adding four registers\ncollapses attention mass on high-norm patch tokens from $0.382$ to $0.007$,\nrenders those patches causally inert under ablation, and makes the registers\nload-bearing instead. Fourth, for image--text contrastive models,\nremoving eight of roughly 200 tokens costs 15--21 accuracy points under every\npooling operator tested, with matched random-ablation controls showing no effect. Fifth, the sign of the ablation effect depends on the training objective rather than the evaluation protocol. It remains invariant across a band of layers, three evaluators, and neighbourhood sizes spanning two orders of magnitude, while exceeding matched random controls by $5$--$20\\times$. This resolves an\napparent protocol dependence in which pooled and per-token evaluation yield\nopposite-signed conclusions about the same intervention.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "dee66e58-3633-432a-bad0-22baac95e0bc"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "What Artifact Tokens in Vision Transformers Are, and What They Do",+ "authors": [],+ "abstract": "Vision Transformers develop a handful of high-norm ``artifact'' tokens that\noccupy low-information image regions and absorb a disproportionate share of\nattention. Register tokens were introduced to eliminate them, and a subsequent\naudit reported that the phenomenon does not generalise uniformly across\narchitectures. We present a measurement study across 15 pretrained checkpoints\nand 10 datasets spanning 9 visual domains. First, artifact formation is determined by model weights, not input statistics,\nas varying the fraction of low-information patches over a $9.1\\times$ range\nchanges artifact strength with a coefficient of variation of only\n$0.030$--$0.102$, while leaving the peak-artifact layer exactly invariant for\nevery model on every dataset, including histopathology, chest radiography, and satellite imagery. Second, the behaviour\nemerges with scale, appearing between 22M and 87M parameters on matched DINOv2\ncheckpoints. Third, register tokens work by capturing the read target. Adding four registers\ncollapses attention mass on high-norm patch tokens from $0.382$ to $0.007$,\nrenders those patches causally inert under ablation, and makes the registers\nload-bearing instead. Fourth, for image--text contrastive models,\nremoving eight of roughly 200 tokens costs 15--21 accuracy points under every\npooling operator tested, with matched random-ablation controls showing no effect. Fifth, the sign of the ablation effect depends on the training objective rather than the evaluation protocol. It remains invariant across a band of layers, three evaluators, and neighbourhood sizes spanning two orders of magnitude, while exceeding matched random controls by $5$--$20\\times$. This resolves an\napparent protocol dependence in which pooled and per-token evaluation yield\nopposite-signed conclusions about the same intervention.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}