Free-Breathing Ungated Cine Cardiac MRI in Seconds via a Cross-Slice Transformer
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 19:24 UTC · 40ff477d922c ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "rlgHVNYllJ"- }- ],- "title": "Free-Breathing Ungated Cine Cardiac MRI in Seconds via a Cross-Slice Transformer",- "authors": [],- "abstract": "Cine cardiac MRI is the clinical gold standard for measuring heart function, but a full exam typically takes an hour or more, since it depends on repeated breath-holds and electrocardiogram (ECG) gating that are difficult or unreliable for patients with dyspnea or arrhythmia. Real-time MRI captures each 2D frame within a fraction of a heartbeat, needing neither, but slices are acquired sequentially, each capturing the heart at a different respiratory position and cardiac state. Reassembling them into a coherent 3D volume, known as slice-to-volume reconstruction (SVR), still relies on breath-holds, ECG, or self-gating in existing methods, which also take minutes per subject. We present $\\textbf{CardioStitch}$, to our knowledge the first cardiac SVR method that is simultaneously $\\textit{free-breathing}$, $\\textit{gating- and synchronization-free}$, and $\\textit{ultra-fast}$. Rather than synchronizing slices, we $\\textit{condition}$ on a reference slice that defines the target cardiac state: a cross-slice transformer reasons jointly over the entire stack and, in a single forward pass, predicts dense 2D-to-3D deformations that correct respiratory and cardiac motion together, and varying the reference yields a 3D cine. Trained on 628 subjects from five public datasets, CardioStitch reconstructs a full cine in 2 s, over $35\\times$ faster than optimization-based methods. It outperforms baselines given the full real-time series of every slice plus ECG or self-gating on all image metrics, cutting respiratory error from 4.2 to 0.9 mm, and on all functional metrics under simulated atrial fibrillation. CardioStitch also transfers without retraining to real free-breathing, ungated scans, including from a patient with atrial fibrillation.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "a81d3993-623f-4f4c-a781-db3c986a4eb7"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "Free-Breathing Ungated Cine Cardiac MRI in Seconds via a Cross-Slice Transformer",+ "authors": [],+ "abstract": "Cine cardiac MRI is the clinical gold standard for measuring heart function, but a full exam typically takes an hour or more, since it depends on repeated breath-holds and electrocardiogram (ECG) gating that are difficult or unreliable for patients with dyspnea or arrhythmia. Real-time MRI captures each 2D frame within a fraction of a heartbeat, needing neither, but slices are acquired sequentially, each capturing the heart at a different respiratory position and cardiac state. Reassembling them into a coherent 3D volume, known as slice-to-volume reconstruction (SVR), still relies on breath-holds, ECG, or self-gating in existing methods, which also take minutes per subject. We present $\\textbf{CardioStitch}$, to our knowledge the first cardiac SVR method that is simultaneously $\\textit{free-breathing}$, $\\textit{gating- and synchronization-free}$, and $\\textit{ultra-fast}$. Rather than synchronizing slices, we $\\textit{condition}$ on a reference slice that defines the target cardiac state: a cross-slice transformer reasons jointly over the entire stack and, in a single forward pass, predicts dense 2D-to-3D deformations that correct respiratory and cardiac motion together, and varying the reference yields a 3D cine. Trained on 628 subjects from five public datasets, CardioStitch reconstructs a full cine in 2 s, over $35\\times$ faster than optimization-based methods. It outperforms baselines given the full real-time series of every slice plus ECG or self-gating on all image metrics, cutting respiratory error from 4.2 to 0.9 mm, and on all functional metrics under simulated atrial fibrillation. CardioStitch also transfers without retraining to real free-breathing, ungated scans, including from a patient with atrial fibrillation.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}