The Sharp Plane Is Tilted: Anisotropy Priors Must Follow the Stored Affine, Not the Grid
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 19:25 UTC · d0e137b3acef ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "BGt2ypAkc2"- }- ],- "title": "The Sharp Plane Is Tilted: Anisotropy Priors Must Follow the Stored Affine, Not the Grid",- "authors": [],- "abstract": "Restoration models for anisotropic 3-D data need one piece of physics: the direction of worst resolution. Recent 3-D microscopy restoration methods hard-code it as the grid axis $z$. We show that this is a statement about the resampling that produced the stored volume: under a linear resample $A$ of the acquisition, the plane of best resolution $\\mathcal S$ maps to $A\\mathcal S$ and its normal $\\mathbf a_0$ to $A^{-\\top}\\mathbf a_0$, so a grid-axis prior is exact only when the transported axis still lands on a grid axis. For stage-scanned light-sheet data $A$ is the deskew affine the file records; when it leaves the camera plane tilted, the worst axis is $\\mathbf{n}=A^{-\\top}e_{\\rm scan}$ or $\\mathbf s=Ae_{\\rm scan}$, both read from the file and ordered by the ratio of $A$'s column norms. On 107 blocks from 18 open-top light-sheet biopsies (7 patients) the spectrum's sharp lobe lies along the camera axis $A$ predicts in 103/107 blocks, and a sweep that uses no network finds $\\mathbf{n}$ the cheapest direction to under-sample on the median over blocks. On held-out blocks decimated along $\\mathbf{n}$, the restorer that assumes $z$ leaves them worse than unrestored in explained variance (EV) at decimation factors $k=4$ and $8$ (0/4 patient-disjoint folds improve them). The same network pointed at $\\mathbf{n}$ improves them in 4/4 folds and beats the convention by $+.025$, $+.060$ and $+.040$ in EV at $k=4$, $8$ and $16$, and by $.047$ F1 on a nucleus-detection endpoint that does not use EV ($k=8$). The gap survives the published CARE recipe, and eight restorers trained at fixed axes from $-45^\\circ$ to $90^\\circ$ trace a curve that peaks at the file's angle ($k\\le8$). On a second instrument (oblique-plane microscopy) a degradation whose stored-frame direction the file sets (every second camera frame dropped before the deskew) is improved only by the restorer pointed at the file's scan direction once its kept-slice mask input is removed; on brain cone-beam CT with an injected oblique axis and a true reference the rotated prior beats the $z$ prior in 9/9 fold$\\times$seed pairs. The fix is one signed angle per stored volume, read from the file.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "9f5013be-416c-4eae-8740-699e18e6d783"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "The Sharp Plane Is Tilted: Anisotropy Priors Must Follow the Stored Affine, Not the Grid",+ "authors": [],+ "abstract": "Restoration models for anisotropic 3-D data need one piece of physics: the direction of worst resolution. Recent 3-D microscopy restoration methods hard-code it as the grid axis $z$. We show that this is a statement about the resampling that produced the stored volume: under a linear resample $A$ of the acquisition, the plane of best resolution $\\mathcal S$ maps to $A\\mathcal S$ and its normal $\\mathbf a_0$ to $A^{-\\top}\\mathbf a_0$, so a grid-axis prior is exact only when the transported axis still lands on a grid axis. For stage-scanned light-sheet data $A$ is the deskew affine the file records; when it leaves the camera plane tilted, the worst axis is $\\mathbf{n}=A^{-\\top}e_{\\rm scan}$ or $\\mathbf s=Ae_{\\rm scan}$, both read from the file and ordered by the ratio of $A$'s column norms. On 107 blocks from 18 open-top light-sheet biopsies (7 patients) the spectrum's sharp lobe lies along the camera axis $A$ predicts in 103/107 blocks, and a sweep that uses no network finds $\\mathbf{n}$ the cheapest direction to under-sample on the median over blocks. On held-out blocks decimated along $\\mathbf{n}$, the restorer that assumes $z$ leaves them worse than unrestored in explained variance (EV) at decimation factors $k=4$ and $8$ (0/4 patient-disjoint folds improve them). The same network pointed at $\\mathbf{n}$ improves them in 4/4 folds and beats the convention by $+.025$, $+.060$ and $+.040$ in EV at $k=4$, $8$ and $16$, and by $.047$ F1 on a nucleus-detection endpoint that does not use EV ($k=8$). The gap survives the published CARE recipe, and eight restorers trained at fixed axes from $-45^\\circ$ to $90^\\circ$ trace a curve that peaks at the file's angle ($k\\le8$). On a second instrument (oblique-plane microscopy) a degradation whose stored-frame direction the file sets (every second camera frame dropped before the deskew) is improved only by the restorer pointed at the file's scan direction once its kept-slice mask input is removed; on brain cone-beam CT with an injected oblique axis and a true reference the rotated prior beats the $z$ prior in 9/9 fold$\\times$seed pairs. The fix is one signed angle per stored volume, read from the file.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}