ECGDuo: Complementary Distillation from ECG and Time-Series Foundation Models
Import ICLR 2027 submission CH710z2Jb9: 17 notes
@openreview[bot] · 2026-11-22 20:57 UTC · f0fd4181cb05 ·
reviews/openreview/ch710z2jb9/forms.json added
+++ b/reviews/openreview/ch710z2jb9/forms.json@@ -0,0 +1,183 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "additional_comments_on_reviewer_discussion",+ "label": "Reviewer discussion",+ "type": "text"+ },+ {+ "key": "recommendation",+ "label": "Recommendation",+ "type": "choice"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "soundness",+ "presentation",+ "informativeness"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "soundness",+ "label": "Soundness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "presentation",+ "label": "Presentation",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "informativeness",+ "label": "Informativeness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "paper_summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "critical_strengths",+ "label": "Strengths",+ "type": "text"+ },+ {+ "key": "critical_weaknesses",+ "label": "Weaknesses",+ "type": "text"+ },+ {+ "key": "questions_for_authors",+ "label": "Questions for the authors",+ "type": "text"+ },+ {+ "key": "flag_for_ethics_review",+ "label": "Flag for ethics review",+ "type": "choice",+ "omitWhen": [+ "No",+ "No ethics review needed."+ ]+ },+ {+ "key": "details_of_ethics_concerns",+ "label": "Ethics concerns",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/3v07xvcsqj.json added
+++ b/reviews/openreview/ch710z2jb9/notes/3v07xvcsqj.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "3V07XVCSqJ",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer mnjP",+ "content": {+ "paper_summary": "This paper proposes ECGDuo, a lightweight ECG encoder distilled from an ECG foundation model and a general time-series foundation model. Two teacher-specific adapters align the shared student representation with the respective teachers using symmetric contrastive distillation. Experiments on five ECG datasets demonstrate competitive performance with substantially fewer parameters.",+ "presentation": 3,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "The motivation for compressing large ECG foundation models into lightweight encoders is practically relevant.\n\nThe proposed model achieves competitive performance with only 0.137M parameters, demonstrating promising deployment efficiency.\n\nThe evaluation includes five datasets, subject-independent cross-validation, teacher ablations, and representation analyses.",+ "critical_weaknesses": "W1. Limited methodological novelty. The framework primarily combines established techniques, including multi-teacher distillation, independent projection heads, and contrastive representation alignment. Related methods such as UNIC (ECCV 2024) and Formont et al. (NeurIPS 2025) have already investigated complementary representation learning through multiple teachers. The main distinction appears to be the combination of ECG and general time-series foundation models rather than a fundamentally new distillation mechanism.\n\nW2. Insufficient evidence for the central motivation. The paper assumes that a general time-series foundation model contains task-relevant temporal information absent from ECG-specific representations. However, this assumption is not directly verified. The conditional mutual information used to define complementarity is never estimated, and the experiments do not establish whether Sundial provides additional predictive information beyond the ECG teacher.\n\nW3. Incomplete ablation studies. Improvements over ECG-only distillation demonstrate the benefit of additional supervision, but not necessarily complementary cross-domain knowledge. Important controls, including TSFM-only distillation, two ECG-specific teachers, and duplicated-teacher supervision, are missing. Without these comparisons, the improvements may reflect generic multi-teacher regularization rather than the claimed complementarity.\n\nW4. Limited theoretical and experimental validation. The theoretical results rely on general information-theoretic identities and assumptions that are not verified experimentally. Furthermore, CKA improvements and better feature clustering do not establish that complementary diagnostic information is retained. The main comparisons also lack compact pretrained student baselines and repeated independent distillation runs.",+ "questions_for_authors": "Novelty: What is the fundamental methodological difference between ECGDuo and existing multi-teacher representation distillation approaches, particularly UNIC and Formont et al.?\n\nComplementarity: Can the authors demonstrate that combining the frozen ECG and TSFM teacher representations improves downstream prediction over the ECG teacher alone?\n\nAblations: Would distillation from two ECG-specific teachers or duplicated ECG-teacher supervision yield comparable improvements?\n\nMechanism: How do the theoretical complementarity conditions relate to the actual optimization objective? Can the authors demonstrate which diagnostic information is uniquely transferred from Sundial?\n\nEvaluation: Can the authors include comparable compact pretrained baselines, report variability across independent distillation runs, and clarify potential pretraining-data overlap with downstream benchmarks?",+ "flag_for_ethics_review": "No",+ "rating": 2,+ "confidence": 3+ },+ "createdAt": "2026-10-22T11:45:42.052Z",+ "modifiedAt": "2026-11-06T12:24:26.504Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=3V07XVCSqJ",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/5kjoiketqh.json added
+++ b/reviews/openreview/ch710z2jb9/notes/5kjoiketqh.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "5KjOiKEtqH",+ "replyTo": "OGnCVXnFt0",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer ATkf (2/2): controls, baselines, protocol and cardiac content",+ "comment": "**2(i) Distillation variance and second-teacher controls**\n\nEvery second-teacher student in Table R1 (Table 4) now has the same five independent distillation seeds (2026–2030), with all requested controls.\n\n**Variance.** The seed standard deviation (SD) is 0.17–0.45 Avg (mean of six metrics over five datasets). ECGDuo exceeds the ECGFounder-only student by 1.81 and the ECGFounder + ECG-FM student by 1.12, in 5/5 paired seeds (paired t p < .001).\n\n**Any second target?** A duplicated teacher adds nothing (−0.01) and a random-network target hurts (−0.85). Pretrained targets help less: ECG-FM +0.69 (5/5), permuted Sundial +0.42 (4/5); none reaches ECGDuo, and Sundial alone gives the lowest student (80.56).\n\n**Another time-series foundation model (TSFM).** Over five seeds, the ECGFounder + MOMENT student reaches 83.83 ± 0.13 Avg, +0.31 over ECGFounder-only (App. E.1, E.3). Adding a TSFM also helps other electrocardiogram (ECG) teachers, and Sundial helps most (App. E.5):\n\n| ECG teacher | ECG-only student | + Sundial | + MOMENT |\n|---|:---:|:---:|:---:|\n| HuBERT-ECG | 76.88 | **80.13** | 78.34 |\n| MERL | 80.01 | **81.14** | 80.47 |\n\n**2(ii) Same-encoder baselines**\n\n**Same-encoder comparison.** Both requested baselines use the same depthwise-separable convolutional neural network (DSCNN), one with contrastive multi-segment coding (CMSC) self-supervision and one trained end-to-end, and ECGDuo leads both (Table 2, App. E.4):\n\n| Same DSCNN encoder | CPSC2018 | G12EC | PTB-XL | Avg |\n|---|:---:|:---:|:---:|:---:|\n| CMSC self-supervision, same 671k windows, linear probe | 67.88 | 66.77 | 76.70 | 76.15 |\n| Trained end-to-end per task | 78.49 | 76.82 | 82.47 | 83.37 |\n| **ECGDuo, frozen + linear head** | **80.40** | **81.57** | **82.94** | **85.56** |\n\nThe same encoder trained from scratch is the strongest supervised baseline, 2.19 Avg behind ECGDuo (0.47 on PTB-XL to 4.75 on G12EC). CMSC pairs two windows per subject, as in CLOCS; ST-MEM uses a transformer (App. E.4).\n\n**2(iii) Protocol**\n\n- **Teacher inputs.** ECGFounder and ECG-FM receive exactly the student's 3-s, 12-lead window at the native rate, z-scored per lead with whole-record statistics, without teacher-specific filtering or resampling. Sundial encodes each lead in 512-sample chunks, mean-pooled over tokens, chunks and leads (§3.2, App. D.1).\n- **Sampling rates.** Signals are not resampled, so a fixed kernel spans different durations at 400, 500 and 1000 Hz; each benchmark is evaluated at its single rate with identical windows for every encoder; lowering the input to 250 or 125 Hz costs ECGDuo only 0.07 and 0.48 Avg (Table H.1).\n- **Window scoring.** Subject-level scores now average window probabilities per label unit; ECGDuo reaches 86.82 vs 85.34 for the ECGFounder + ECG-FM student (5/5 seeds; App. D.2, E.2).\n- **Curated labels.** We add the official multi-label PTB-XL benchmark, including hypertrophy (HYP), with record-level scoring and folds 1–8 / 9 / 10. ECGDuo's macro area under the receiver operating characteristic curve (AUROC) is above the ECGFounder + ECG-FM student on 6/6 tasks, significantly on superdiagnostic, form and rhythm, most on form (+0.045) and rhythm (+0.029) (§4.7, Table F.3).\n- **PTB.** We agree that 200 subjects cannot carry a claim on their own; the revision makes no claim from PTB alone.\n\n**2(iv) Fig. 1 and cardiac content**\n\n**Fig. 1.** The original traces were not generated by artificial intelligence: they were ECG curves shown after moderate low-pass filtering and downsampling for a cleaner display. Fig. 1 now draws recorded 3-s ECG windows directly; [**this link**](https://anonymous.4open.science/r/ECGDuo-8848/fig1.ipynb) plots these windows as recorded and after low-pass filtering and downsampling. \"GroupNorm\" and \"Depthwise\" are corrected; the downstream step is named \"linear probe\", and the label-scarcity figure (now Fig. 5) x-axis reads \"Fraction of labeled training subjects\".\n\n**Centered kernel alignment (CKA).** We agree that the increase toward Sundial is expected by construction; it is now descriptive only (§4.5).\n\n**Which cardiac information improves.** Ridge probes on frozen features, ECGDuo minus the ECGFounder-only student, 5 seeds (Table 7; RR: interval between consecutive R peaks):\n\n| ΔR² | PTB-XL | CPSC2018 |\n|---|:---:|:---:|\n| RMSSD (root mean square of successive RR differences) | +0.067 | +0.070 |\n| RR coefficient of variation | +0.054 | +0.069 |\n| RR min/max ratio | +0.060 | +0.074 |\n| Heart rate | +0.020 | +0.029 |\n\nAll four gains hold in 5/5 seeds (paired t p < .01), with a multilayer-perceptron (MLP) probe as well (App. G.1).\n\n***Thank you again for the time and care you gave this review. Whatever your final assessment, the paper is substantially better because of it, and we would be grateful if you would reassess the value and contribution of this application study in light of these results.***"+ },+ "createdAt": "2026-11-10T17:56:08.642Z",+ "modifiedAt": "2026-11-18T11:05:04.410Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=5KjOiKEtqH",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/7f4flihgkb.json added
+++ b/reviews/openreview/ch710z2jb9/notes/7f4flihgkb.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "7F4flihGkb",+ "replyTo": "xnJGonUquH",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer hnkC (2/2): evaluation unit and Avg standard deviation",+ "comment": "**W3 / Q2. Evaluation unit and aggregation**\n\nScoring was per 3-s window, with no aggregation; the unit column of the original Table 3, now Table B.1, gave the label unit. Each window inherits the label and fold of its unit, so units with more windows carry more weight (App. D.2).\n\n**Label units.** Record for CPSC2018, CSN and G12EC; patient for PTB-XL; subject for PTB. All recordings of a subject fall in one fold.\n\n**New subject-level scores.** Window softmax probabilities are averaged within each label unit before the metrics are computed, so every unit counts once; head training and selection are unchanged. Avg is the mean of six metrics; ± is the SD over seeds.\n\n| Student (seeds 2026–2030) | CPSC2018 | G12EC | PTB-XL | Avg, window | Avg, subject |\n|---|:---:|:---:|:---:|:---:|:---:|\n| ECGFounder-only | 80.84 | 79.37 | 81.91 | 83.52 ± 0.29 | 84.92 ± 0.33 |\n| ECGFounder + ECG-FM | 80.98 | 80.75 | 81.08 | 84.21 ± 0.28 | 85.34 ± 0.40 |\n| **ECGDuo** | **82.89** | **82.51** | **82.74** | **85.33 ± 0.24** | **86.82 ± 0.38** |\n\nPer-dataset columns are at the subject level; all five datasets are in App. E.1. The ranking is unchanged and ECGDuo's margins grow: +1.90 over ECGFounder-only and +1.48 over ECGFounder + ECG-FM (5/5 seeds each, paired t p = .003), while the ECG-FM student's own gain shrinks to +0.42 (App. E.2).\n\n**Record-level official benchmark.** On official PTB-XL, each record is embedded as the mean of its window embeddings and scored once (folds 1–8 / 9 / 10, multi-label, App. F.2). Macro area under the receiver operating characteristic curve (AUROC), mean over seeds 2026–2030; \\* paired t p < 0.05 (Table F.3):\n\n| PTB-XL task | ECGDuo | Δ vs ECGFounder-only | Δ vs ECGFounder + ECG-FM |\n|---|:---:|:---:|:---:|\n| All statements | 0.848 | +0.013 | +0.011 |\n| Diagnostic | 0.867 | +0.011 | +0.010 |\n| Subdiagnostic | 0.890 | +0.006 | +0.004 |\n| Superdiagnostic | 0.903 | +0.008\\* | +0.012\\* |\n| Form | 0.811 | +0.031 | +0.045\\* |\n| Rhythm | 0.907 | +0.009 | +0.029\\* |\n\nECGDuo is above both students on every task. All-statement area under the precision–recall curve (AUPRC) rises by 0.022 over both students in 5/5 seeds (Table F.3).\n\n**W4 / Q2. Avg standard deviation**\n\nYou are right: the original Avg SD was the mean of the six per-metric SDs, which generally differs from the SD of the composite.\n\n**Composite SD.** For fold $f$, $a_f$ is the mean of accuracy, precision, recall, F1, AUROC and AUPRC; the composite SD is the SD of the five $a_f$.\n\n**Computed from ECGDuo's five folds**, the composite SD is smaller on every dataset (App. C):\n\n| Spread | CPSC2018 | CSN | G12EC | PTB-XL | PTB |\n|---|:---:|:---:|:---:|:---:|:---:|\n| Mean of metric SDs | 1.43 | 0.47 | 1.09 | 0.65 | 4.06 |\n| SD of fold-level Avg | 1.39 | 0.35 | 1.06 | 0.45 | 3.86 |\n\n**What each table shows.** Table 2 keeps the original spread convention (App. D.2). Table C.1 (original Tables 4–5) follows the same convention metric by metric. The new multi-seed student tables report the SD over distillation seeds (0.17–0.45 Avg for the configurations in Table 4), and Table 4 comparisons are paired tests on seeds. App. D.2 distinguishes these definitions.\n\n***Thank you again for pointing us to these fixes; the paper is clearer and its evidence stronger because of them. We hope the clarified protocol and the new controls address your concerns, and we are happy to answer any further questions.***"+ },+ "createdAt": "2026-11-10T17:53:33.081Z",+ "modifiedAt": "2026-11-18T11:05:21.880Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=7F4flihGkb",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/bd1ykg35du.json added
+++ b/reviews/openreview/ch710z2jb9/notes/bd1ykg35du.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Bd1yKG35Du",+ "replyTo": "5KjOiKEtqH",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer ATkf",+ "content": {+ "title": "Response to the authors’ rebuttal",+ "comment": "Dear authors,\n\nBefore turning to the content: I would prefer a more professional tone in this exchange. Remarks on how my review was first read, on its layout, or on your deliberations about withdrawing the paper are not appropriate in a rebuttal and have no bearing; in the opinion of this reviewer.\n\nOn the revision. Thank you for the substantial additional work. Several of my soundness concerns are addressed by the five-seed distillations, the second-teacher controls, the same-encoder baselines, the clarified teacher inputs and the corrected figg 1. The theory is also now appropriately framed as motivation. I still have two concerns\n\n(i) The headline model changed during the rebuttal. ECGDuo was re-tuned. I did not find a search space, budget or validation split, and I could not find whether the ECGFounder-only and ECGFounder + ECG-FM students were tuned the same way. Please clarify if possible. \n\n(ii) The official ptbxl benchmark does not reproduce Table 2. Table 2 places ECGDuo above ECGFounder, yet on the official benchmark ECGDuo trails the frozen ECGFounder probe on 5/6 tasks (Table 6). Its all-statement macro AUROC is also below that of the smaller ECGFounder-only student . It is on par with the Wavelet+nn feature baselin that Strodthoff (2021) report on the same folds, where xresnet1D101 and Inception1D reach 0.925. In Table 2 these architectures trail the DSCNN trained from scratch. I remain concerned that the Setting A baselines may be under-trained and that the curated protocol drives much of the reported advantage. Please let me know what part of my reasoning is not correct, or how you argument for that.\n\nAll in all, scope remains one of my main concerns. You state that ECGDuo \"introduces no new component\", that it \"is an ECG application study\", and that you \"intend it to offer practical insight for ECG applications rather than a new algorithm\" (or method). The finding the revision supports is therefore specific to ECG and to one teacher. ICLR is a machine learning venue. Even in its application areas, I expect claims that generalize beyond a single signal type and matter to the broader machine learning research community. I believe the work is not bad, but I strongly consider this paper out of scope for ICLR. It fits way better the scope of MLHC, IEEE JBHI and other technical-translational venues, where it would reach its natural audience."+ },+ "createdAt": "2026-11-14T17:20:44.990Z",+ "modifiedAt": "2026-11-14T17:21:32.865Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=Bd1yKG35Du",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/cnubehi9ha.json added
+++ b/reviews/openreview/ch710z2jb9/notes/cnubehi9ha.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "cNuBEHi9HA",+ "replyTo": "xnJGonUquH",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer hnkC (1/2): teacher controls and theory",+ "comment": "Dear Reviewer hnkC,\n\nThank you for a careful and constructive review. You caught two ambiguities: the evaluation unit and the standard deviation (SD) of Avg, our mean of six metrics. Fixing them made the paper more precise, and the subject-level scores they led to strengthened the main result: ECGDuo's margins grow. Your request for Sundial-only students and students with two electrocardiogram (ECG) teachers became the core of the new second-teacher study (Table 4). This post answers W1–W2; the next answers W3–W4. Tables R1 and R2 are in the general response.\n\n**W1 / Q1. Sundial-only and two-ECG-teacher students**\n\nBoth are added. They use ECGDuo's encoder (336,128 parameters) and the same 671k unlabeled windows, and ECGDuo exceeds both (Table R1, Table 4; seeds 2026–2030; k/n: seeds with Δ > 0):\n\n| Student | Avg | Subject Avg | Δ Avg vs ECGFounder-only (k/n) |\n|---|:---:|:---:|:---:|\n| Sundial-only | 80.56 ± 0.45 | 82.32 | −2.96 (0/5) |\n| ECGFounder-only | 83.52 ± 0.29 | 84.92 | — |\n| ECGFounder + ECG-FM | 84.21 ± 0.28 | 85.34 | +0.69 (5/5) |\n| **ECGDuo** | **85.33 ± 0.24** | **86.82** | **+1.81 (5/5)** |\n\n**Against two ECG teachers.** ECGDuo exceeds the ECGFounder + ECG-FM student by 1.12 Avg, and by 1.48 at the subject level, in 5/5 paired seeds (paired t p < .001 and .003).\n\n**Against the time-series foundation model (TSFM) alone.** The Sundial-only student is the weakest configuration in Table R1, 2.96 below ECGFounder-only (0/5 seeds), so the TSFM helps next to an ECG teacher, not in place of it.\n\n**At a smaller size.** ECGDuo-Small (ECGDuo-S; 134,912 parameters) reaches 85.21 ± 0.32 Avg, +1.84 over its same-size ECGFounder-only student (5/5, p < .001; Tables E.1–E.2).\n\n**Generic multi-teacher effects.** A duplicated or untrained second target does not raise Avg (−0.01, −0.85). Permuted Sundial targets give +0.42 (4/5, paired t p = .070), well below ECGDuo (83.94 vs 85.33).\n\nBefore distillation, on frozen embeddings, Sundial adds +0.84 Avg to ECGFounder and ECG-FM adds +0.48; after principal component analysis (PCA) to 1,024 dimensions, +0.18 versus −0.60 (Table R2).\n\n**W2. Theory, residual terms and centered kernel alignment (CKA)**\n\nTheorem 3.1 is an elementary sufficient condition: the revision states that it motivates the design and measures the resulting gains directly (§3.1).\n\n- **Task-relevant complementarity, measured on frozen teachers.** A linear probe is the measurable counterpart of $\\Delta_{T|E}$ (App. A.1). ECGFounder ⊕ Sundial lowers held-out log-loss by 0.017 nats while ECGFounder ⊕ ECG-FM leaves it unchanged (Table R2). On official PTB-XL, it raises macro area under the receiver operating characteristic curve (AUROC) over ECGFounder on 6/6 tasks, e.g., +0.048 on all statements, paired-bootstrap 95% confidence interval excluding 0 (Table 6).\n- **Proposition 3.2.** It is informative only if $I(Z_E;Z_T)<2\\ln B-L_E-L_T=6.30$ nats, with $B=1024$, $L_E=2.84$ and $L_T=4.72$. Our held-out information noise-contrastive estimation (InfoNCE) estimate, 6.15 nats, is a lower bound capped at $\\ln B=6.93$, so the bound explains the objective, while the gains are measured directly (Tables R1, R2; App. D.3).\n- **An empirical student–teacher advantage.** In the teacher study of App. E.5, the HuBERT-ECG + Sundial student reaches 80.13 Avg, above the frozen HuBERT-ECG probe (77.27) and the HuBERT-ECG-only student (76.88; App. D.3).\n- **CKA.** We agree that CKA measures similarity, not task information; it is now descriptive only (§4.5). Task information in the trained encoder is measured by probes instead: ECGDuo predicts RMSSD (root mean square of successive differences between RR intervals, the intervals between consecutive R peaks) better than the ECGFounder-only student, ΔR² +0.067 on PTB-XL and +0.070 on CPSC2018, in 5/5 seeds (Table 7).\n\n(Continued in the next post: evaluation unit and Avg SD.)"+ },+ "createdAt": "2026-11-10T17:52:50.753Z",+ "modifiedAt": "2026-11-18T11:05:17.779Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=cNuBEHi9HA",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/fqivir308e.json added
+++ b/reviews/openreview/ch710z2jb9/notes/fqivir308e.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "fqiVir308e",+ "replyTo": "OGnCVXnFt0",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer ATkf (1/2): a personal note; novelty, theory, scope and deployment",+ "comment": "Dear Reviewer ATkf,\n\n**We would like to begin with something more personal than a point-by-point reply.**\n\nWhen your review first arrived, we read it poorly. The lowest score, together with a dense layout in which the points ran into one another, made it feel dismissive to us, and with overall scores of **2/2/1**, we came close to withdrawing the paper.\n\nWe then read it again, slowly, and our view changed completely. **Your review is specific, fair and plainly written in good faith**: *nearly every point names a real weakness of the submission together with the experiment that would test it*. **We are sorry for our first reaction and grateful for the time you gave the paper!** Your review is the main reason we did not withdraw: *even if only to answer it properly, the rebuttal was worth doing, and much of the 16-to-25-page revision is built around your list.*\n\nWe ran every control you listed and follow your numbering; Tables R1 and R2 are in the general response.\n\n**1(i) Novelty**\n\nWe agree that, technically, ECGDuo introduces no new component: per-teacher adapters, same-input teachers and symmetric information noise-contrastive estimation (InfoNCE) losses are established, and the revision credits UNIC, Formont et al. and compact multi-teacher electrocardiogram (ECG) distillation (§§1–2). We believe the revision contributes something of a different kind:\n\n- **An application contribution.** A compact raw-ECG encoder supervised by an ECG foundation model (ECGFM) plus a second teacher. To our knowledge, no prior work jointly distills an ECGFM and a general-purpose time-series foundation model (TSFM) into one such encoder.\n- **Instructive evidence.** Sundial alone gives the weakest student (80.56 vs 83.52 for ECGFounder-only, Table R1), yet next to ECGFounder it adds more label information than a second ECGFM (+0.84 vs +0.48 Avg, mean of six metrics, on frozen embeddings, Table R2).\n- **An extremely compact, broadly deployable, low-cost encoder.** With 1.1% of ECGFounder's parameters, ECGDuo encodes a window in 1.45 ms on one central processing unit (CPU) core, 15× faster than ECGFounder (22.32 ms); ECGDuo-Small (ECGDuo-S) fits in 0.20 MiB (mebibytes) at 8 bits and also works from lead I alone (1(iii)).\n\nWe hope this evidence helps you reassess the value and contributions of our work. As the primary area we chose, applications, indicates, we intend it to offer practical insight for ECG applications rather than a new algorithm.\n\n**1(ii) Theory**\n\nYou are not missing anything: Theorem 3.1 is a motivating sufficient condition and Proposition 3.2 a bound (§3, App. D.3).\n\n- **Proposition 3.2** is informative only if $I(Z_E;Z_T)<2\\ln B-L_E-L_T=6.30$ nats. Our held-out InfoNCE estimate, 6.15 nats, is a lower bound capped at $\\ln B=6.93$; the paper therefore uses the bound to explain the objective and measures the gains directly.\n- **Theorem 3.1** gives a sufficient condition in optimal log-loss (§3.1). Empirically, the HuBERT-ECG + Sundial student exceeds the frozen HuBERT-ECG probe in Avg (80.13 vs 77.27; Table E.3).\n- The claims rest on frozen-teacher probes (Table R2), controlled second-teacher students (Table R1) and physiology probes (2(iv)).\n\n**1(iii) Scope and deployment**\n\nECGDuo is an ECG application study; for the deployment you name, the revision adds single-lead input, per-window CPU cost, 8-bit size and noisy recordings.\n\n**Single lead.** Students see only lead I; teacher targets use all 12 leads (App. E.7; ±: seed standard deviation). ECGDuo and ECGDuo-S exceed their same-size lead-I ECGFounder-only students by 1.29 and 2.03 Avg, respectively (Table E.2):\n\n| Lead-I student | CPSC2018 | G12EC | PTB-XL | Avg |\n|---|:---:|:---:|:---:|:---:|\n| ECGFounder-only | 73.11 | 75.50 | 65.94 | 76.65 ± 0.26 |\n| **ECGDuo** | **74.44** | **77.97** | **66.15** | **77.94 ± 0.13** |\n\n**Cost per window.** On one CPU core, as in bedside monitors and embedded devices, ECGDuo is about 15× faster than ECGFounder (Table 3, replacing the original Fig. 3):\n\n| Encoder | Parameters | Size (MiB) | 1 CPU core, ms |\n|---|:---:|:---:|:---:|\n| ECG-FM | 90,883,072 | 346.69 | 173.05 |\n| ECGFounder | 30,819,014 | 117.57 | 22.32 |\n| ECGDuo | 336,128 | 1.28 | **1.45** |\n| ECGDuo-S | **134,912** | **0.51** | 1.50 |\n\n**Size reference.** The 0.137M you cite counted the 512-d encoder, now ECGDuo-S (134,912), plus a five-class head; ECGDuo uses a 2048-d projector. ECGDuo-S nearly matches ECGDuo (85.21 vs 85.33 Avg), and mixed 8-bit weights shrink it to 0.20 MiB while retaining 98.9% of its 32-bit Avg (App. E.6).\n\n**Noise.** ECGDuo-R, distilled with artifact augmentation, keeps 99.7% of ECGDuo's clean Avg (85.07 vs 85.33). At 0 dB it drops less than both frozen ECGFMs in every column of Table 8 (electromyographic (EMG): 5.17 vs 14.52 for ECGFounder); recorded MIT-BIH Noise Stress Test Database (NSTDB) noise never enters training or selection (App. H)."+ },+ "createdAt": "2026-11-10T17:55:14.862Z",+ "modifiedAt": "2026-11-18T11:05:07.777Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=fqiVir308e",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/hpfvhcm9kq.json added
+++ b/reviews/openreview/ch710z2jb9/notes/hpfvhcm9kq.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "HpFVHcm9KQ",+ "replyTo": "3V07XVCSqJ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer mnjP (1/2): novelty, complementarity and ablations",+ "comment": "Dear Reviewer mnjP,\n\nThank you for a careful and generous review. Your questions were precise in the most useful way: each one named the experiment that would answer it, and we ran all of them. Your complementarity question (W2), whether frozen ECGFounder and Sundial together predict better than ECGFounder alone, is now a main-text analysis (Table 5), and its answer is a clear yes. This post answers W1–W3; the next answers W4. Tables R1 and R2 are in the general response.\n\n**W1 / Q-Novelty. Difference from UNIC and Formont et al.**\n\nThe difference lies in the teacher pair and the question tested, not in the distillation mechanism. As an application study (our primary area), the contribution is an insight for electrocardiogram (ECG) practice: whether a general time-series foundation model (TSFM) or a second ECG foundation model (ECGFM) makes a compact ECG encoder stronger. Per-teacher adapters, same-input teachers and symmetric information noise-contrastive estimation (InfoNCE) losses are established; the revision credits them and removes the term \"single-proxy transfer bottleneck\" (abstract, §1, §5).\n\n| | Teachers | Student | Question tested |\n|---|---|---|---|\n| UNIC | several vision models | image encoder | multi-task vision transfer |\n| Formont et al. | diverse pretrained embedders | task-agnostic encoder | generic transfer |\n| ECG multi-teacher self-distillation (Wang et al., 2025) | deeper branches of an ECG model | lightweight arrhythmia classifier | arrhythmia recognition |\n| **ECGDuo** | **ECGFM + general TSFM** | **compact raw-ECG encoder, linear probe** | **which second teacher helps an ECGFM** |\n\nTo our knowledge, no prior work jointly distills an ECG-specialist foundation model and a general-purpose time-series foundation model into one compact raw-ECG encoder. The pairing is not obvious: the Sundial-only student is the weakest in Table R1 (80.56 vs 83.52 for the ECGFounder-only student), yet next to ECGFounder it adds more label information than a second ECGFM does (Table R2). Adding Sundial also raised the Avg (mean of six metrics over the five datasets) of students of other ECG teachers, by 3.25 for HuBERT-ECG and 1.13 for MERL (App. E.5).\n\n**W2 / Q-Complementarity. Do frozen ECGFounder and Sundial together predict better than ECGFounder alone?**\n\nYes. A linear probe on frozen ECGFounder ⊕ Sundial raises Avg on 5/5 datasets, by 0.84 on average, and lowers held-out log-loss by 0.017 nats; ECG-FM adds 0.48 and leaves log-loss unchanged. After principal component analysis (PCA) to 1,024 dimensions, the Sundial gain stays positive at +0.18 and the ECG-FM gain turns negative at −0.60 (Table R2). This probe gain is the measurable linear-probe counterpart of the conditional mutual information (App. A.1).\n\n**Official PTB-XL.** The benchmark gives the same picture (folds 1–8 / 9 / 10, macro area under the receiver operating characteristic curve (AUROC)):\n\n| PTB-XL task | ECGFounder ⊕ Sundial | Δ vs ECGFounder | Δ vs ECGFounder ⊕ ECG-FM |\n|---|:---:|:---:|:---:|\n| All statements | 0.919 | +0.048* | +0.045* |\n| Diagnostic | 0.919 | +0.039* | +0.047* |\n| Subdiagnostic | 0.922 | +0.041* | +0.029* |\n| Superdiagnostic | 0.918 | +0.009* | 0.000 |\n| Form | 0.868 | +0.047* | +0.038* |\n| Rhythm | 0.956 | +0.040* | +0.024 |\n\n\\* Paired-bootstrap 95% confidence interval (CI) over test records excludes 0. Both concatenations are validation-selected (Table F.2).\n\n**W3 / Q-Ablations. Two ECG teachers, duplicated teacher, TSFM only**\n\nTwo ECG teachers help, but less than ECGDuo does; a duplicated teacher does not help (Table R1, Table 4).\n\n- **ECGFounder + ECG-FM:** 84.21, +0.69 over the ECGFounder-only student (5/5 seeds). ECGDuo, 85.33, exceeds it by 1.12 in 5/5 paired seeds (paired t p < .001).\n- **Duplicated ECGFounder:** 83.51, −0.01 (2/5). An untrained network target gives 82.67, −0.85 (0/5).\n- **Sundial-only:** 80.56, −2.96 (0/5).\n- **Permuted Sundial targets:** 83.94, +0.42 (4/5, paired t p = .070), well below ECGDuo's 85.33.\n\nSo the largest gain comes from pairing Sundial with the ECG teacher; neither a second branch on the same teacher nor Sundial alone comes close.\n\n(Continued in the next post: theory, mechanism and evaluation.)"+ },+ "createdAt": "2026-11-10T17:50:51.955Z",+ "modifiedAt": "2026-11-18T11:05:32.067Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=HpFVHcm9KQ",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/kmmhe1ox6h.json added
+++ b/reviews/openreview/ch710z2jb9/notes/kmmhe1ox6h.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "kmmHe1oX6h",+ "replyTo": "Vte6P55PQ4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer ATkf",+ "content": {+ "title": "Response 2 to Authors",+ "comment": "Dear authors,\n\nThank you for the quick and clear follow-up. I need to follow up on your answers, as it is still not fully clear to me:\n\n(i) On the model selection, thank you for the search space. As I understand it, the two-teacher students were re-tuned in this round and the single-teacher students were not. The like-for-like comparison is therefore ECGDuo against the other two-teacher students, and the margin over ECGFounder-only may partly reflect the extra tuning. I could not find how the 2048-d projector was chosen, as it is not in the search space. I also could not find whether the single-teacher students were tuned at that width. Please clarify if possible.\n\n(ii) on ptb-xl, I agree that Tables 2 and 6 use different tasks and protocols, and that is my point: the ranking changes with the protocol. The 512-d comparison is helpful, and it is a good result that ECGDuo-s is above its single-teacher student on most official tasks. It also shows that the headline 2048-d model is not the better of the two widths on the official benchmark. In my opinion, the claim that ECGDuo outperforms ECGFounder should be stated as holding on the curated tasks.\n\n(iii) Setting A: I agree that a frozen linear probe and end-to-end training are not directly comparable, and I did not mean to compare them. My point is that, under the same search ranges, XResNet1D and Inception1D trail the small DSCNN by about 20 Avg points in Table 2, while on the official benchmark these architectures are among the strongest. A simple sanity check would be to train your implementation on the official PTB-XL split and compare it with the published result.\n\nI agree that venue fit is ultimately for the Area Chair to weigh, and I'll be happy to offer mi view. On your central question, the answer the revision supports seems specific to Sundial: with ECGFounder, MOMENT adds less than a second ECG teacher does. As for the cited ICLR papers, most of them, in my understanding, also propose a new method, model or benchmark, whereas by your own account ECGDuo introduces no new component. I will take the revision and this discussion into account in my final assessment, including the individual scores and the final score."+ },+ "createdAt": "2026-11-15T10:14:02.096Z",+ "modifiedAt": "2026-11-15T10:14:02.096Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=kmmHe1oX6h",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/ogncvxnft0.json added
+++ b/reviews/openreview/ch710z2jb9/notes/ogncvxnft0.json@@ -0,0 +1,25 @@+{+ "schema": "review/1",+ "id": "OGnCVXnFt0",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer ATkf",+ "content": {+ "paper_summary": "The paper proposes ECGDuo, a 0.137M-parameter depthwise-separable CNN for 12-lead ECG distilled from two frozen teachers: an ECG foundation model (ECGFounder by default, ECG-FM in the ablations) and a general time-series foundation model (Sundial). Teacher embeddings of 3-s windows from MIMIC-IV-ECG and CODE-15 are cached offline, and the student is trained with a symmetric InfoNCE loss through one linear adapter per teacher. Two information-theoretic results motivate the second teacher. Evaluation is a linear probe on five classification datasets (CPSC2018, CSN, G12EC, PTB-XL, PTB) with subject-independent five-fold cross-validation, against supervised end-to-end models and frozen foundation models, plus ablations with and without Sundial, label efficiency, latency and CKA analyses. ECGDuo averages 83.73 against 84.00 for ECGFounder.",+ "presentation": 2,+ "informativeness": 1,+ "soundness": 2,+ "critical_strengths": "1. The main strength, to me, is the practical result: a 0.137M-parameter frozen encoder with a linear head that stays within 0.3 points of ECGFounder on average over five datasets and is about 20 to 55 times faster at inference (fig 3). This sounds useful to practitioners.\n2. The evaluation is careful: subject-independent folds shared by all methods, labels of the distillation corpora never used, single- and dual-teacher students matched on windows, capacity and update budget, and code released.",+ "critical_weaknesses": "1. Novelty is limited for ICLR, and the scope, only 12-lead ECG, is too narrow\n(i) In my opinion the methodological novelty is limited for ICLR. Distilling several heterogeneous foundation models into one student through teacher-specific adapters is the not new, which is also the setting the paper uses to set itself apart from multi-teacher distillation: different teachers looking at the same input. The loss is the CLIP-style symmetric InfoNCE of contrastive representation distillation. Multi-teacher distillation of compact ECG models already exists. What is new is choosing a general time-series model as the second teacher. The \"single-proxy transfer bottleneck\" is, to me, a new name for distilling from one teacher.\n(ii) The theory does not support the claims. Theorem 3.1 is the chain rule plus \"conditioning cannot increase entropy\", and neither the complementarity term nor the residual term is ever estimated. its headline case, a student that beats its ECG teacher, does not happen: ECGDuo is below ECGFounder on four of five datasets. Proposition 3.2 is the InfoNCE bound applied to each branch; with B = 1024, 2 log B is about 13.9 nats, so the bound only says something if I(ZE; ZT) is below that, which is never checked for two embeddings of the same window… Am I missing something?\n(iii) The scope is too narrow for ICLR… only 12-lead ECG, 3-s windows and single-label classification on five curated datasets. The idea is generic, a domain foundation model plus a general time-series model distilled into a compact student, so if that is the claim it has to be shown on other physiological signals where both kinds of teacher exist (EEG, PPG, EMG, IMU), and on wearable single-lead ECG, which is where a 0.137M encoder would potentially matter(?). To me, clinical 12-lead ECG is not where a 30M-parameter model is a deployment problem; Fig. 3 gives ECGFounder 20 to 65 ms per batch of 128. As it stands this is an ECG compression study, and I feel it fits better applied venues.\n2. Nothing shows that the time-series teacher is what helps…\n(i) The gain from adding Sundial is about one Avg point over the ECGFounder-only student from a single distillation seed. The stds in Table 2 are over downstream folds and the CIs in fig 6 over head seeds, so none of them capture distillation variance, which can easily be of that size. And nothing isolates the general time-series knowledge: there is no second ECG teacher (ECG-FM plus ECGFounder), no random or weak second teacher, no Sundial-only student, and no other time-series model. Without these, the gain could come from any second target. This needs to be done thoroughly imo.\n(ii) some key baselines are missing; the same DSCNN trained from scratch on each task, and the same DSCNN pretrained with ECG self-supervision on the same MIMIC-IV-ECG and CODE-15 windows without any teacher (e.g., CLOCS, which is cited, or ST-MEM, ICLR 2024). Setting A compares a frozen encoder that saw about 670k unlabeled windows and two foundation teachers with supervised models trained only on the downstream folds, several of which look under-trained … so the gains say little.\n(iii) The protocol makes the numbers hard to compare with anything published: 3-s windows carrying record-level labels are scored one by one, the label sets are curated single-label subsets (PTB-XL without HYP and only patients with one shared superclass), and signals are not resampled across 400, 500 and 1000 Hz, so the same kernels cover 2.5 times more time on CODE-15 than on PTB. Maybe I am missing something, could you please clarify how the 3-s windows are fed to ECGFounder and ECG-FM, which were pretrained on longer recordings? Also, the abstract's \"0.1% of Sundial's parameters\" is not the right reference. The one that matters is ECGFounder (0.45%), which ECGDuo trails on four of five datasets, and the PTB win (91.26 vs 87.33 +- 5.23) is on 200 subjects.\n(iv) For an ECG paper, the ECG in Fig. 1 is not an ECG. The traces labelled \"ECG Signals\"; they look like generic time series (probably ai generated?). The same figure also has \"GruopNorm\" and \"Deepthwise\", and calls the linear probe \"fine-tuning\". To me this goes with a wider issue: there is no analysis of what cardiac information the time-series teacher adds (rhythm, intervals, morphology?), and the CKA increase toward Sundial in Fig. 7 is by construction, since the student is trained to match it.",+ "questions_for_authors": "My main concerns are the two weaknesses above.I copy-apste them here. I’d be open to raise the score if the scope is generalize and all my concerns are tackled, but novelty is a key limitation in any case…\n1. Novelty is limited for ICLR, and the scope, only 12-lead ECG, is too narrow\n(i) In my opinion the methodological novelty is limited for ICLR. Distilling several heterogeneous foundation models into one student through teacher-specific adapters is the not new, which is also the setting the paper uses to set itself apart from multi-teacher distillation: different teachers looking at the same input. The loss is the CLIP-style symmetric InfoNCE of contrastive representation distillation. Multi-teacher distillation of compact ECG models already exists. What is new is choosing a general time-series model as the second teacher. The \"single-proxy transfer bottleneck\" is, to me, a new name for distilling from one teacher.\n(ii) The theory does not support the claims. Theorem 3.1 is the chain rule plus \"conditioning cannot increase entropy\", and neither the complementarity term nor the residual term is ever estimated. its headline case, a student that beats its ECG teacher, does not happen: ECGDuo is below ECGFounder on four of five datasets. Proposition 3.2 is the InfoNCE bound applied to each branch; with B = 1024, 2 log B is about 13.9 nats, so the bound only says something if I(ZE; ZT) is below that, which is never checked for two embeddings of the same window… Am I missing something?\n(iii) The scope is too narrow for ICLR… only 12-lead ECG, 3-s windows and single-label classification on five curated datasets. The idea is generic, a domain foundation model plus a general time-series model distilled into a compact student, so if that is the claim it has to be shown on other physiological signals where both kinds of teacher exist (EEG, PPG, EMG, IMU), and on wearable single-lead ECG, which is where a 0.137M encoder would potentially matter(?). To me, clinical 12-lead ECG is not where a 30M-parameter model is a deployment problem; Fig. 3 gives ECGFounder 20 to 65 ms per batch of 128. As it stands this is an ECG compression study, and I feel it fits better applied venues.\n2. Nothing shows that the time-series teacher is what helps…\n(i) The gain from adding Sundial is about one Avg point over the ECGFounder-only student from a single distillation seed. The stds in Table 2 are over downstream folds and the CIs in fig 6 over head seeds, so none of them capture distillation variance, which can easily be of that size. And nothing isolates the general time-series knowledge: there is no second ECG teacher (ECG-FM plus ECGFounder), no random or weak second teacher, no Sundial-only student, and no other time-series model. Without these, the gain could come from any second target. This needs to be done thoroughly imo.\n(ii) some key baselines are missing; the same DSCNN trained from scratch on each task, and the same DSCNN pretrained with ECG self-supervision on the same MIMIC-IV-ECG and CODE-15 windows without any teacher (e.g., CLOCS, which is cited, or ST-MEM, ICLR 2024). Setting A compares a frozen encoder that saw about 670k unlabeled windows and two foundation teachers with supervised models trained only on the downstream folds, several of which look under-trained … so the gains say little.\n(iii) The protocol makes the numbers hard to compare with anything published: 3-s windows carrying record-level labels are scored one by one, the label sets are curated single-label subsets (PTB-XL without HYP and only patients with one shared superclass), and signals are not resampled across 400, 500 and 1000 Hz, so the same kernels cover 2.5 times more time on CODE-15 than on PTB. Maybe I am missing something, could you please clarify how the 3-s windows are fed to ECGFounder and ECG-FM, which were pretrained on longer recordings? Also, the abstract's \"0.1% of Sundial's parameters\" is not the right reference. The one that matters is ECGFounder (0.45%), which ECGDuo trails on four of five datasets, and the PTB win (91.26 vs 87.33 +- 5.23) is on 200 subjects.\n(iv) For an ECG paper, the ECG in Fig. 1 is not an ECG. The traces labelled \"ECG Signals\"; they look like generic time series (probably ai generated?). The same figure also has \"GruopNorm\" and \"Deepthwise\", and calls the linear probe \"fine-tuning\". To me this goes with a wider issue: there is no analysis of what cardiac information the time-series teacher adds (rhythm, intervals, morphology?), and the CKA increase toward Sundial in Fig. 7 is by construction, since the student is trained to match it.",+ "flag_for_ethics_review": "No",+ "details_of_ethics_concerns": "N/A",+ "rating": 1,+ "confidence": 3+ },+ "createdAt": "2026-10-19T17:21:13.919Z",+ "modifiedAt": "2026-11-18T10:28:25.485Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=OGnCVXnFt0",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/sar1jnmtqf.json added
+++ b/reviews/openreview/ch710z2jb9/notes/sar1jnmtqf.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "sar1JNMtqf",+ "replyTo": "xtaz0YgLbx",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer mnjP",+ "content": {+ "title": "Response",+ "comment": "Thank you to the authors for the detailed response. While the additional experiments address some of my soundness concerns, the discrepancy between the curated evaluation and the official benchmark remains a critical issue."+ },+ "createdAt": "2026-11-15T13:56:28.848Z",+ "modifiedAt": "2026-11-15T13:56:28.848Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=sar1JNMtqf",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/tqtw2nkdij.json added
+++ b/reviews/openreview/ch710z2jb9/notes/tqtw2nkdij.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "tqtW2NkDiJ",+ "replyTo": "t1dBGL75Kb",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer ATkf",+ "content": {+ "title": "Final Response",+ "comment": "Dear authors,\n\nThank for following up. The value, strengths, limitations, and caveats, are clear to me. For now, following the discussions with all reviewers and myself, I keep my general score while updating the soundness metric. Thanks."+ },+ "createdAt": "2026-11-18T10:28:02.781Z",+ "modifiedAt": "2026-11-18T10:28:02.781Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=tqtW2NkDiJ",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/vte6p55pq4.json added
+++ b/reviews/openreview/ch710z2jb9/notes/vte6p55pq4.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Vte6P55PQ4",+ "replyTo": "Bd1yKG35Du",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer ATkf,\n\nThank you for your careful follow-up. We address your remaining concerns below.\n\n**(i) Model selection**\n\n**Only the two-teacher students were re-tuned during the rebuttal.** For our ECGDuo (ECGFounder + Sundial) and the other two-teacher students, model selection was performed on validation data only. The TSFM weight was selected from $w_T \\in$ {0.25, 0.5, 0.75, 1, 2}, alongside the following hyperparameters:\n\n| Hyperparameter | Values searched |\n|---|---|\n| Distillation epochs | 5, 10, 20, 40, 50 |\n| InfoNCE temperature $\\tau$ | 0.05, 0.07, 0.10, 0.14, 0.20 |\n| Distillation learning rate | 0.003, 0.005, 0.01, 0.02 |\n| Linear-probe learning rate | 0.0001, 0.0003, 0.001 |\n\nThe single-teacher students in Tables 2 and C.1, ECGFounder-only, ECG-FM-only and Sundial-only, do not involve $w_T$. They had previously been tuned over the same four hyperparameter ranges and were not re-tuned in this round.\n\n**(ii) Official PTB-XL and Table 2**\n\n**Tables 2 and 6 evaluate different tasks under different protocols.** Table 2 covers five curated single-label tasks, evaluated per window and summarised by the mean of six metrics. Table 6 covers the six official PTB-XL statement sets, evaluated per record using macro AUROC.\n\nYou are correct that the 2048-d ECGDuo trails frozen ECGFounder on 5/6 official tasks. At the 512-d student width, however, ECGDuo-Small (ECGDuo-S) outperforms the ECGFounder-only student (Table F.1):\n\n| Official PTB-XL: all statements | Macro AUROC |\n|---|---:|\n| Frozen ECGFounder | 0.871 |\n| ECGFounder-only student, 512-d | 0.875 |\n| ECGDuo-S, 512-d | **0.890** |\n\nAcross the six official statement sets, ECGDuo-Small exceeds frozen ECGFounder on four: **all, diagnostic, subdiagnostic and rhythm**.\n\nRegarding *Strodthoff et al. [1]*, their reported 0.925 is obtained through end-to-end training at 100 Hz. In contrast, Table 6 **freezes every encoder and trains only a linear layer** at 500 Hz. The two results therefore reflect different training and evaluation settings.\n\n**(iii) Setting A**\n\nAll architectures evaluated under Setting A in Tables 2 and C.1 use the same hyperparameter search ranges below:\n\n| Hyperparameter | Values searched |\n|---|---|\n| Training epochs | 5, 10, 20, 40, 50 |\n| Learning rate | 0.0001, 0.0003, 0.001 |\n\nAll models are trained end-to-end using AdamW and a cosine learning-rate schedule, with early stopping based on validation macro-F1.\n\n**(iv) Contribution and scope**\n\n**We respect your view on venue fit and leave it to the Area Chair.**\n\nOur central research question is ***whether a general-purpose time-series foundation model can provide complementary supervision to a domain-specific foundation model when distilling a compact ECG student***. \n\nThis question connects ECGDuo to representation-learning research at ICLR, which has ***included comprehensive work on ECG representation learning, generation and foundation-model evaluation [2–6].***\n\nFinally, we would be grateful if you could reassess the paper’s **presentation, informativeness, and soundness, as venue-independent aspects of the work**, and reconsider your overall score in light of the evidence presented in the revised manuscript and rebuttal.\n\nThank you again for your time and consideration!\n\n**References**\n\n*[1] Deep Learning for ECG Analysis: Benchmarks and Insights from PTB-XL. IEEE JBHI, 2021.*\n\n*[2] Guiding Masked Representation Learning to Capture Spatio-Temporal Relationship of Electrocardiogram. ICLR, 2024.*\n\n*[3] Large-scale Training of Foundation Models for Wearable Biosignals. ICLR, 2024.*\n\n*[4] Reading Your Heart. ICLR, 2025.*\n\n*[5] Benchmarking ECG FMs: A Reality Check Across Clinical Tasks. ICLR, 2026.*\n\n*[6] Simulator and Experience Enhanced Diffusion Model for Comprehensive ECG Generation. ICLR, 2026.*"+ },+ "createdAt": "2026-11-14T21:27:21.839Z",+ "modifiedAt": "2026-11-18T11:04:58.131Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=Vte6P55PQ4",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/xnjgonuquh.json added
+++ b/reviews/openreview/ch710z2jb9/notes/xnjgonuquh.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "xnJGonUquH",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer hnkC",+ "content": {+ "paper_summary": "ECGDuo distills an ECG foundation model and a general time-series foundation model into a compact ECG encoder using teacher-specific adapters and symmetric contrastive losses. The student is evaluated through frozen-encoder linear probing on five datasets, with analyses of teacher contributions, label efficiency, representation alignment, and inference cost.",+ "presentation": 2,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "1. The student model with much less parameter achieves an average score of 83.73 across five datasets, close to ECGFounder, while removing both teachers and adapters at inference. This provides a useful accuracy–size trade-off.\n\n2. Single-teacher and dual-teacher comparisons control the student architecture, training data, optimizer, and update budget. Improvements across two ECG teachers and five datasets, together with subject-independent evaluation and label-scarcity experiments, support the practical benefit of additional TSFM supervision.",+ "critical_weaknesses": "1. The ablations establish that adding Sundial helps, but do not isolate cross-domain temporal complementarity. A Sundial-only student and an ECGFounder+ECG-FM student are missing. These controls would distinguish the proposed heterogeneous pairing from generic multi-teacher benefits.\n\n2. The theoretical conditions are not connected sufficiently to the trained model. Neither task-relevant complementarity nor residual compression loss is measured, and the contrastive objective does not guarantee their required relationship. CKA changes measure representation similarity rather than preservation of task-relevant information.\n\n3. The evaluation unit is unclear. Table 3 specifies record-, patient-, or subject-level targets, whereas Appendix B.2 describes evaluation using three-second windows without an aggregation rule. This affects interpretation and sample weighting.\n\n4. Across Tables 4–5, the reported Avg standard deviations match the arithmetic mean of the six metric standard deviations to rounding. This generally differs from the across-fold standard deviation of the composite score. The calculation should be clarified and verified using fold-level results.",+ "questions_for_authors": "1. How does ECGDuo compare with capacity-matched Sundial-only and two-ECG-teacher students under the same training budget?\n2. How are window predictions aggregated into the stated evaluation units, and how are the Avg standard deviations computed?",+ "flag_for_ethics_review": "No",+ "rating": 2,+ "confidence": 4+ },+ "createdAt": "2026-10-22T02:56:33.288Z",+ "modifiedAt": "2026-11-06T12:24:27.356Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=xnJGonUquH",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/xtaz0yglbx.json added
+++ b/reviews/openreview/ch710z2jb9/notes/xtaz0yglbx.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "xtaz0YgLbx",+ "replyTo": "3V07XVCSqJ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer mnjP (2/2): theory, mechanism and evaluation",+ "comment": "**W4 / Q-Mechanism. How the theory relates to the objective**\n\nThe theory motivates the objective, and the revision now states its role precisely (§3.1, App. D.3).\n\n- **Theorem 3.1** is a sufficient condition that follows from the chain rule: if the task-relevant complementarity of the time-series foundation model (TSFM) exceeds the information lost in compression, the student's optimal log-loss falls below the electrocardiogram (ECG) teacher's. Table R2 measures the teacher-side predictive gain through frozen linear probes; the student gains in Table R1 then show the benefit that reaches the compact encoder.\n- **Proposition 3.2** links the two optimized branch losses to joint retention. It is informative only if $I(Z_E;Z_T)<2\\ln B-L_E-L_T=6.30$ nats, with $B=1024$, $L_E=2.84$ and $L_T=4.72$. Our held-out information noise-contrastive estimation (InfoNCE) estimate, 6.15 nats, is a lower bound capped at $\\ln B=6.93$, so it cannot settle the condition.\n\n**W4 / Q-Mechanism. Which diagnostic information is uniquely transferred from Sundial?**\n\n**Diagnostic probes.** The revision measures what ECGDuo represents better than the ECGFounder-only student, rather than attributing information to Sundial alone (Table 7, App. G.1; RR interval: interval between consecutive R peaks):\n\n| Ridge probe on frozen features, ΔR² | PTB-XL | CPSC2018 |\n|---|:---:|:---:|\n| RMSSD (root mean square of successive RR differences) | +0.067 | +0.070 |\n| RR coefficient of variation | +0.054 | +0.069 |\n| RR min/max ratio | +0.060 | +0.074 |\n| Heart rate | +0.020 | +0.029 |\n\nAll four targets improve in 5/5 seeds (paired t p < .01). RMSSD error falls by 3.4 / 6.5 ms (Table G.1), and a multilayer-perceptron (MLP) probe agrees in 5/5 seeds (p ≤ .004).\n\nPer class, all 20 classes improve, most for long QT (+9.48 F1) and sinus arrhythmia (+5.74; App. G.2). On official PTB-XL, ECGDuo's largest area under the receiver operating characteristic curve (AUROC) gains over the ECGFounder + ECG-FM student are on form (+0.045) and rhythm (+0.029) statements (Table F.3). We agree that centered kernel alignment (CKA) and cluster quality measure geometry, not diagnostic content; the revision presents CKA as descriptive only (§4.5).\n\n**W4 / Q-Evaluation. Compact baselines, run variability, data overlap**\n\n- **Compact pretrained baselines.** The same depthwise-separable convolutional neural network (DSCNN) pretrained with contrastive multi-segment coding (CMSC), as in CLOCS, on the same 671k unlabeled windows reaches 76.15 Avg (mean of six metrics over five datasets); trained end-to-end per task, it reaches 83.37 (Table 2, App. E.4). The distilled students of Table R1 are compact pretrained baselines as well, and ECGDuo leads all of them.\n- **Independent distillation runs.** The second-teacher students in Table R1 share five distillation seeds (2026–2030); their seed standard deviation (SD) is 0.17–0.45 Avg, and their comparisons are paired on seeds (App. E.1–E.3).\n- **Pretraining-data overlap.** ECGDuo's distillation corpora, MIMIC-IV-ECG and CODE-15 (labels unused), share no source with the five benchmarks; its teachers are ECGFounder, pretrained on the Harvard–Emory ECG Database, and Sundial, a general-purpose TSFM (App. D.1).\n\n***Thank you again for the questions that made the paper sharper. We hope these answers resolve your concerns, and we would be glad to clarify anything further.***"+ },+ "createdAt": "2026-11-10T17:51:43.209Z",+ "modifiedAt": "2026-11-18T11:05:35.867Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=xtaz0YgLbx",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/yvalnm1oix.json added
+++ b/reviews/openreview/ch710z2jb9/notes/yvalnm1oix.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "YValNm1oIx",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "General response: thank you, and what the revision adds",+ "comment": "We thank all three reviewers for the specific experiments you requested. **The revision grows from 16 to 25 pages**: five new appendix sections (D–H) report the teacher-target controls, repeated distillations over five seeds, same-encoder baselines, the official PTB-XL benchmark, lead-I and corrupted-input experiments, and measured deployment cost. Revisiting the training objective in light of mnjP's and hnkC's questions on how the complementarity conditions relate to it, we found that the submission had not adapted the hyperparameters of the full ECGDuo framework, such as the Sundial weight $w_T$, fixed to equal weighting. We now select them on validation data only (App. D.5); Table 2 and Fig. 2 report the resulting ECGDuo, whose 2048-d projector gives 336,128 parameters. **Changes are color-marked by the reviewer.**\n\n**Paired with an electrocardiogram (ECG) foundation model, Sundial gives the strongest compact student we trained, and on frozen embeddings it adds more to ECGFounder than a second ECG foundation model does.**\n\n**Table R1. Second-teacher controls** (Table 4; mean over seeds 2026–2030; Avg: mean of six metrics over the five datasets)\n\n| Student | CPSC2018 | G12EC | PTB-XL | Avg | Subject Avg | Δ Avg vs ECGFounder-only (k/n, p) |\n|---|:---:|:---:|:---:|:---:|:---:|:---:|\n| Sundial-only | 71.96 | 77.52 | 74.64 | 80.56 ± 0.45 | 82.32 | −2.96 (0/5, < .001) |\n| ECGFounder + random network | 76.93 | 76.52 | 80.80 | 82.67 ± 0.24 | 84.11 | −0.85 (0/5, .008) |\n| ECGFounder-only | 78.20 | 78.19 | 81.87 | 83.52 ± 0.29 | 84.92 | — |\n| ECGFounder + duplicated ECGFounder | 78.13 | 78.06 | 81.84 | 83.51 ± 0.17 | 85.00 | −0.01 (2/5, .95) |\n| ECGFounder + permuted Sundial | 78.35 | 79.05 | 81.88 | 83.94 ± 0.18 | 85.26 | +0.42 (4/5, .070) |\n| ECGFounder + ECG-FM | 78.80 | 79.58 | 81.03 | 84.21 ± 0.28 | 85.34 | +0.69 (5/5, .021) |\n| **ECGDuo** (ECGFounder + Sundial) | **80.07** | **81.33** | **82.62** | **85.33 ± 0.24** | **86.82** | **+1.81 (5/5, < .001)** |\n\n±: standard deviation (SD) over the five distillation seeds; k/n: seeds with Δ > 0; p: two-sided paired t test on seeds. All five datasets: App. E.1.\n\n**ECGDuo leads every configuration.** +1.12 Avg over the ECGFounder + ECG-FM student and +1.81 over ECGFounder-only, in 5/5 paired seeds each (p < .001); +1.48 and +1.90 at the subject level (App. E.2). Even its lowest seed is above the best seed of every other configuration in Table R1 (at most 84.62).\n\n**An extra branch is not enough.** A duplicated target (−0.01) and an untrained target (−0.85) do not raise Avg. Pretrained second targets help, but less than Sundial does in ECGDuo: ECG-FM +0.69 (5/5), permuted Sundial +0.42 (4/5).\n\n**Table R2. Frozen teacher embeddings, before any distillation** (Table 5, App. F.1)\n\nLinear probe on concatenated frozen embeddings, change from frozen ECGFounder; principal component analysis (PCA) rows reduce them to 1,024 dimensions on training windows.\n\n| Frozen embedding | CPSC2018 | G12EC | PTB-XL | Avg | Datasets up | Δ log-loss (nats) |\n|---|:---:|:---:|:---:|:---:|:---:|:---:|\n| ECGFounder ⊕ Sundial | +1.13 | +0.39 | +0.23 | **+0.84** | 5/5 | **−0.017** |\n| ECGFounder ⊕ ECG-FM | +0.55 | +0.18 | +0.22 | +0.48 | 5/5 | \\|Δ\\| < 0.001 |\n| ECGFounder ⊕ Sundial, PCA | +0.88 | +0.01 | +0.22 | **+0.18** | 4/5 | — |\n| ECGFounder ⊕ ECG-FM, PCA | +0.65 | −0.53 | +0.05 | −0.60 | 3/5 | — |\n\nSundial adds more label information to ECGFounder than ECG-FM does, and at matched dimensions the Sundial gain stays positive (+0.18) while the ECG-FM gain turns negative (−0.60). On official PTB-XL, ECGFounder ⊕ Sundial significantly raises macro area under the receiver operating characteristic curve (AUROC) over ECGFounder on 6/6 tasks and over ECGFounder ⊕ ECG-FM probe on 4/6 (paired-bootstrap 95% confidence intervals; Table 6).\n\n**Shared concerns**\n\n| Concern | Resolution | Where |\n|---|---|---|\n| Novelty (mnjP, ATkf) | Prior multi-teacher work credited; contribution framed as an application insight: which second teacher makes a compact ECG encoder stronger | §§1–2 |\n| Theory (all) | Theorem 3.1 as a motivating sufficient condition, Prop. 3.2 as a bound | §3, App. D.3 |\n| Evaluation (hnkC, ATkf) | Window scoring stated; subject-level scores and fold-level SDs added | App. C, D.2, E.2 |\n| Curated labels (ATkf) | Official PTB-XL: ECGDuo above the ECGFounder + ECG-FM student on 6/6 tasks | §4.7, App. F.2 |\n| Cardiac content (all) | Probes of variability in intervals between successive R peaks (RR intervals) improve in all 5 seeds; centered kernel alignment (CKA) descriptive only | §4.5/4.7, App. G.1 |\n| Compactness (ATkf) | Compact encoder: ECGDuo-Small (ECGDuo-S) has 134,912 parameters (0.44% of ECGFounder), 85.21 Avg (seeds 2026–2030), 1.50 ms per window on one processor core | §4.4, Tables 3, E.1 |\n\n**Again, thank you all for your insightful reviews, which strengthened the paper.**"+ },+ "createdAt": "2026-11-10T17:43:40.872Z",+ "modifiedAt": "2026-11-18T11:05:50.952Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=YValNm1oIx",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/zbmhdi9yku.json added
+++ b/reviews/openreview/ch710z2jb9/notes/zbmhdi9yku.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "zBMhDI9YKU",+ "replyTo": "sar1JNMtqf",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer mnjP,\n\nThank you for your reply. We are glad that the additional experiments resolved some of your concerns, and **we especially appreciate that you read the full discussion, including our recent exchange with Reviewer ATkf.** This shows real care, and we are grateful for your time and effort.\n\n**(i) Curated tasks vs. the official PTB-XL benchmark**\n\nThe two evaluations ask different questions. The curated tasks (**Table 2**) test five single-label diagnoses across five datasets. The official ptbxl benchmark (**Table 6**) tests 71 multi-label statements per record. **On the official benchmark, the main findings hold:**\n\n- **The TSFM teacher helps at every width.** The TSFM-supervised student beats its ECGFM-only counterpart on all 6 tasks in macro AUPRC, at both 2048-d and 512-d (**Table F.1**).\n- **A compact student can match the teacher.** ECGDuo-Small beats frozen ECGFounder on all statements (**0.890 vs. 0.871** macro AUROC) with 0.44% of its parameters.\n- **ECGDuo is competitive end-to-end.** Fine-tuned on the official ptbxl protocol, it reaches 0.924 macro AUROC on all statements. That matches the published XResNet1D and Inception1D (0.925). *More details are in our most recent exchange with Reviewer ATkf.*\n\n**To align every claim with the evidence behind it, we will report the official benchmark separately for each width and limit the comparison with frozen ECGFounder to the curated tasks.** The central finding, that a general TSFM adds complementary supervision to an ECG foundation model, holds under both evaluations.\n\nThank you again for your careful engagement!"+ },+ "createdAt": "2026-11-15T14:53:23.072Z",+ "modifiedAt": "2026-11-18T11:05:39.562Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=zBMhDI9YKU",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/notes/zrm3y2ab5c.json added
+++ b/reviews/openreview/ch710z2jb9/notes/zrm3y2ab5c.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Zrm3Y2Ab5C",+ "replyTo": "kmmHe1oX6h",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer ATkf,\n\nThank you for the constructive follow-up and for **keeping your final assessment open.**\n\n**(i) Projector width**\n\n**The 2048-d projector is the default setting and was not searched in this round.** The revision reports the 512-d encoder as a separate variant, ECGDuo-Small (ECGDuo-S), aimed at ***exploring more compact deployment:*** 134,912 parameters (0.44% of ECGFounder). Single-teacher students already exist at both widths: 2048-d (**Table 4**) and 512-d (**Table F.1**). \n\n**(ii) ECGFounder comparison**\n\n**We agree with your interpretation.** The revision will explicitly state that ECGDuo's advantage over frozen ECGFounder applies to the **curated tasks in Table 2**. We will report and interpret the official PTB-XL results separately for each student width, making the scope of each comparison clear.\n\n**(iii) Sanity check on the official PTB-XL split**\n\nThank you for suggesting this sanity check. **Our implementations achieve results closely matching the published benchmark under the official PTB-XL protocol.**\n\nWe reran our setting A \"XResNet1D\" and \"Inception1D\", and the end-to-end DSCNN and fine-tuned ECGDuo on the official ptb-xl protocol:\n\n| Model (end-to-end) | All statements |\n|---|---|\n| XResNet1D, published *[1]* | 0.925 |\n| XResNet1D, our run | 0.926 |\n| Inception1D, published *[1]* | 0.925 |\n| Inception1D, our run | 0.922 |\n| DSCNN, trained from scratch | 0.901 |\n| **ECGDuo, fine-tuned** | **0.924** |\n\n*Setup.* Macro AUROC on the official split: folds 1–8 for training, fold 9 for selection and fold 10 for testing, seed 2026. \n\nOur implementations reproduce the published results, so the gap to these models in Table 2 comes from the protocol difference. ***Interestingly, distillation adds 2.3 points over the same encoder trained from scratch.*** This suggests that the distilled knowledge also benefits end-to-end fine-tuning: it gives the compact encoder a better starting point than random initialization, enough to match the SOTA method.\n\n**(iv) Scope**\n\nWe agree that, with ECGFounder, MOMENT adds less than a second ECG teacher (+0.31 vs +0.69 Avg). We will narrow the claim to: among the general TSFMs we tested, Sundial is the most effective second teacher. \n\nThank you for your timely feedback, and again for your time and careful engagement.\n\n*[1] Deep Learning for ECG Analysis: Benchmarks and Insights from PTB-XL. IEEE JBHI 2021.*"+ },+ "createdAt": "2026-11-15T14:41:01.635Z",+ "modifiedAt": "2026-11-18T11:04:48.902Z",+ "url": "https://openreview.net/forum?id=CH710z2Jb9¬eId=Zrm3Y2Ab5C",+ "license": "CC-BY-4.0"+}
reviews/openreview/ch710z2jb9/submission.json added
+++ b/reviews/openreview/ch710z2jb9/submission.json@@ -0,0 +1,16 @@+{+ "schema": "submission/1",+ "id": "CH710z2Jb9",+ "venue": {+ "id": "ICLR.cc/2027/Conference",+ "name": "ICLR 2027",+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference"+ },+ "number": 23848,+ "keywords": [+ "ECG",+ "Foundation model distillation"+ ],+ "url": "https://openreview.net/forum?id=CH710z2Jb9",+ "license": "CC-BY-4.0"+}
versions/v_gu8div4j.json added
+++ b/versions/v_gu8div4j.json@@ -0,0 +1,21 @@+{+ "date": "2026-09-16",+ "kind": "submitted",+ "label": "ICLR 2027",+ "submissions": [+ {+ "venue": "ICLR 2027",+ "status": "under_review",+ "number": 23848,+ "url": "https://openreview.net/forum?id=CH710z2Jb9",+ "reviews": "openreview/ch710z2jb9",+ "evidence": [+ "https://openreview.net/forum?id=CH710z2Jb9"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=CH710z2Jb9",+ "evidence": [+ "https://openreview.net/forum?id=CH710z2Jb9"+ ]+}