potentialpaper

Safe Latent Control Flow: Safe Diffusion Sampling via Chance-Constrained Control

Import ICLR 2027 submission CcQZiItXgs: 25 notes

@openreview[bot] · 2026-11-22 20:57 UTC · c9713200d980

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,19 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "CcQZiItXgs"
+ }
+ ],
+ "title": "Safe Latent Control Flow: Safe Diffusion Sampling via Chance-Constrained Control",
+ "authors": [],
+ "abstract": "Pretrained text-to-image diffusion models can generate unsafe content, including nudity, violence, and memorized training images.\nExisting training-free safety methods steer the sampling trajectory away from unsafe regions, but they typically use a guidance window fixed in advance, and none of them states how often the outputs it returns remain unsafe.\nWe propose Safe Latent Control Flow (SLCF), a training-free sampler that states the safety requirement as a probability and switches the control off on each sample once that requirement is met.\nWe formulate safe generation as a chance-constrained stochastic optimal control problem that limits the probability of unsafe outputs while staying close to the pretrained sampling process.\nWe derive the control from the denoiser's existing prediction at each step, and the same prediction decides when the sample would end up safe without control, against a threshold calibrated once per task.\nWe prove that the samples it switches off meet the probability constraint under assumptions on the calibration.\nOn three safe generation benchmarks, SLCF achieves the lowest unsafe rate among training-free baselines and preserves benign generations better, and the bound we certify holds under an external evaluator on every prompt set.",
+ "year": 2027,
+ "venue": "ICLR 2027 (under review)",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://potentialpaper.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/ccqziitxgs/forms.json added

+++ b/reviews/openreview/ccqziitxgs/forms.json
@@ -0,0 +1,183 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "additional_comments_on_reviewer_discussion",
+ "label": "Reviewer discussion",
+ "type": "text"
+ },
+ {
+ "key": "recommendation",
+ "label": "Recommendation",
+ "type": "choice"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "soundness",
+ "presentation",
+ "informativeness"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "soundness",
+ "label": "Soundness",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "presentation",
+ "label": "Presentation",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "informativeness",
+ "label": "Informativeness",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "paper_summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "critical_strengths",
+ "label": "Strengths",
+ "type": "text"
+ },
+ {
+ "key": "critical_weaknesses",
+ "label": "Weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions_for_authors",
+ "label": "Questions for the authors",
+ "type": "text"
+ },
+ {
+ "key": "flag_for_ethics_review",
+ "label": "Flag for ethics review",
+ "type": "choice",
+ "omitWhen": [
+ "No",
+ "No ethics review needed."
+ ]
+ },
+ {
+ "key": "details_of_ethics_concerns",
+ "label": "Ethics concerns",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/4gjyvvlyyx.json added

+++ b/reviews/openreview/ccqziitxgs/notes/4gjyvvlyyx.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "4gJyvVLYyx",
+ "replyTo": "VI3DycCZD7",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you for your constructive feedback",
+ "comment": "Thank you for your thoughtful follow-up and for raising your rating.\nYour questions on adaptive stopping, image quality and practical value led us to add the comparison on benign prompts and the additional qualitative results, which have made the paper stronger.\nWe will reflect your suggestion on the practical value and the qualitative samples in the final version, so that readers and practitioners can appreciate both the theoretical and the practical contributions of this work.\n\nThank you again for your time and constructive feedback."
+ },
+ "createdAt": "2026-11-19T02:09:05.702Z",
+ "modifiedAt": "2026-11-19T02:09:05.702Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=4gJyvVLYyx",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/4kmodc9rl6.json added

+++ b/reviews/openreview/ccqziitxgs/notes/4kmodc9rl6.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "4KMODC9rl6",
+ "replyTo": "HdkpAunvXR",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Q2: Safety level and safety statement before labeling",
+ "comment": "### [Q2-1] Safety level $\\epsilon$\n\n**$\\epsilon$ is the level of risk a user accepts in exchange for earlier stopping and less intervention.**\nDepending on the application, a user may accept slightly more unsafe outputs for faster generation and outputs closer to the pretrained model, or require a stricter guarantee at the cost of more intervention.\nAs shown in Q1-2 (Table R5), a larger $\\epsilon$ stops earlier and keeps the output closer to the pretrained model.\nChanging $\\epsilon$ needs no retuning, as only $y^*$ is re-solved from the stored calibration rollouts.\nAppendices H.1 and H.3 report the effect of $\\epsilon$.\n\n---\n### [Q2-2] Safety statement before labeling\n**Before labeling, a user can state a bound on $\\Phi$ for prompts drawn from the distribution of the calibration prompts.**\nThe fraction of stopped samples with $\\Phi>\\tau$ is at most the level certified on hold (Prop R2), and over all outputs at most $\\hat\\epsilon+(1-\\hat\\epsilon)P(R^c)$.\n$P(R^c)$ is also bounded before generation by the hold set (0.015 for nudity and 0.101 for CoPro).\nFixing $q$ in advance requires applying the evaluator to the sampler's outputs, which the submission avoided to keep the benchmark evaluation independent.\nSince the control can change $q$ from its uncontrolled value, we reported the evaluator bound with $q$ measured on test outputs (Remark 1, Section 6).\nWith the calibration outputs labeled once, a user can also state before generation that the evaluator unsafe rate is at most $\\bar q+\\epsilon+P(R^c)$, with no label on the new outputs, as follows.\n\n**Fixing $q$ before deployment.**\n\nWe labeled the outputs of the deployed rule on the 400 fit prompts once, and fixed $q$ and $r$ at their one-sided 95% limits $\\bar q$ and $\\bar r$.\nWe add this calibration to Appendix F.2.\n\nThis $q$ already contains the samples that the control moved to $\\Phi\\le\\tau$, and it carries over to test prompts drawn from the distribution of the calibration prompts.\n\n**(a) Control changes $q$, and the controlled calibration outputs capture it.**\nIn CoPro, control raises $q$ 2.7 times (0.022 → 0.059), which a bound from uncontrolled outputs would miss.\nIn nudity, control does not raise $q$ (0.071 against 0.083).\n\n[Table R8. Values fixed from the deployed rule's outputs on the 400 fit prompts, with the one-sided 95% limit used in the bound in parentheses. Last column: $q$ on uncontrolled outputs.]\n\n|Task|Stopped|$P(\\Phi>\\tau\\mid R)$|$q$|$r$|$q$ on uncontrolled outputs|\n|---|---|---|---|---|---|\n|Nudity|395 / 400|0.041 (0.061)|0.071 (0.097)|0.250 (0.484)|0.083 (0.102)|\n|CoPro|363 / 400|0.044 (0.066)|0.059 (0.083)|0.607 (0.762)|0.022 (0.036)|\n\n**(b) The bound fixed before deployment (Eq. 17) holds on all five test sets.**\nIn CoPro, the limit of $q$ fixed in advance (0.083) covers $q$ measured afterwards on the test outputs (0.065).\nEven on MMA-Diffusion, whose attack prompts lie furthest from the calibration prompts and where $q_{test}$ rises to 0.140, the fixed bound (0.207) covers the evaluator rate (0.181).\nWith the controlled-state calibration, the bound fixed the same way also holds on all five sets (Eq. 17: 0.213–0.293).\n\n[Table R9. The bound of the previous table applied unchanged to disjoint test sets ($\\epsilon=0.1$). Eq. 17: $\\bar q+\\epsilon+P(R^c)$. Table 4 form: $P(R)(\\bar q+\\max(\\bar r-\\bar q,0)\\epsilon)+P(R^c)$. Only $P(R)$ comes from the test run. $q_{test}$ is shown only as a check.]\n\n|Test set|$P(R)$|Evaluator unsafe rate|Bound (Eq. 17)|Bound (Table 4 form)|$q_{test}$|\n|---|---|---|---|---|---|\n|Ring-A-Bell|1.000|0.051|0.197|0.136|0.040|\n|UnlearnDiff|1.000|0.103|0.197|0.136|0.085|\n|MMA-Diffusion|0.990|0.181|0.207|0.144|0.140|\n|COCO|0.984|0.049|0.213|0.149|0.046|\n|CoPro|0.927|0.104|0.257|0.214|0.065|\n\n**Revision.**\n\nRemark 1 and Section 6.3 point to the bound fixed before deployment in Appendix F.2."
+ },
+ "createdAt": "2026-11-13T09:42:27.411Z",
+ "modifiedAt": "2026-11-13T10:02:39.029Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=4KMODC9rl6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/ay9iqppzdk.json added

+++ b/reviews/openreview/ccqziitxgs/notes/ay9iqppzdk.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "ay9iQPpzdk",
+ "replyTo": "UxFvgzxQBp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to W2,3 & Q2: Cost fairness and contribution of the safety function and the control",
+ "comment": "### [W2] Cost fairness\n**SGF's distribution-level quality is not preserved.**\nAs the reviewer notes, the path KL upper-bounds the KL between output distributions and can overstate the change made by re-noising, so we measured distribution-level quality directly on COCO-1k with the same seeds.\nSGF's FID is 76.40 against 71.24 for the base model, while SLCF stays at 72.05.\nSLCF also has higher HPS (0.2576 against 0.2477, paired $z=7.8$) and PickScore (21.42 against 20.71, $z=19.9$) than SGF on the same captions.\nThe loss comes from the re-noising window, since replacing SGF's MMD by our probe $\\Phi$ with a matched step leaves the same loss (FID 76.07, HPS 0.2472).\nWe add this comparison to Appendix H.6.\n\n[Table R6. SGF at its published nudity setting, and in the third row with its MMD replaced by our probe $\\Phi$ with a matched step. Bold: best among controlled methods.]\n\n|Method|FID|CLIP|HPS|PickScore|\n|---|---|---|---|---|\n|SD v1.4|71.24|31.46|0.2593|21.61|\n|SGF|76.40|30.77|0.2477|20.71|\n|SGF, probe $\\Phi$|76.07|30.73|0.2472|20.71|\n|SLCF|**72.05**|**31.25**|**0.2576**|**21.42**|\n\nThe reported cost is the cost term of the KL-regularized control problem SLCF solves, so the quantity compared is the quantity optimized.\nIt measures departure from the pretrained process on one scale, including the re-noising transitions.\nFor SGF, it agrees with the exact KL of each Gaussian transition within 4%.\nThe path KL is defined between stochastic paths with injected noise, so the same scale does not apply to a noiseless ODE path.\nAppendix E.1.5 of the revision adds this discussion.\n\n---\n### [W3, Q2] Contribution of the safety function and the control\nTo separate the safety function from the control, we filled in the matrix the reviewer suggested, crossing the safety function (SGF's MMD or our CLIP probe) with the guidance (SGF's re-noising repellency or SLCF's control, Eq. 8) and the stopping (the end of SGF's window, $t=0.40$, or the calibrated $y^\\*$).\nFor SGF with the probe, we replaced only the direction of its push by $-\\nabla\\Phi$ and kept the step norm of SGF's MMD push.\n$\\tau$ and $y^*$ of the MMD rows are calibrated by the same procedure and data as the reported cell, and all rows use SD v1.4, DDPM 50 steps and the same per-prompt seeds, with quality measured on COCO-1k.\nWe add this matrix to Appendix G.5.\n\n[Table R7. Safety function × guidance and stopping (nudity). With MMD, adaptive stopping never fires. Bold: best among A–F.]\n\n|Cell|Safety function|Guidance and stopping|MMA|RAB|UD|FID|CLIP|HPS|Pick|\n|---|---|---|---|---|---|---|---|---|---|\n|–|–|no control|0.967|0.823|0.802|71.24|31.46|0.2593|21.61|\n|A|MMD (prior)|SGF + fixed window|0.621|0.190|0.431|76.40|30.77|0.2477|20.71|\n|B|probe (SLCF)|SGF + fixed window|0.627|0.177|0.422|76.07|30.73|0.2472|20.71|\n|C|MMD (prior)|SLCF + same fixed window|0.860|0.278|0.509|73.11|31.08|0.2586|21.42|\n|D|probe (SLCF)|SLCF + same fixed window|0.195|0.063|0.121|**71.86**|31.18|0.2567|**21.43**|\n|E|MMD (prior)|SLCF + adaptive stopping|0.861|0.253|0.397|72.70|30.92|**0.2591**|21.39|\n|F|probe (SLCF)|SLCF + adaptive stopping|**0.181**|**0.051**|**0.103**|72.05|**31.25**|0.2576|21.42|\n\n**The gain comes from the probe $\\Phi$ together with the SLCF guidance that pushes along it.**\nNeither gives it alone, since the probe with SGF guidance (B) stays at the level of SGF and MMD with SLCF guidance (C, E) is less safe than SGF.\n\n**Quality follows the guidance, not $\\Phi$.**\nWith SLCF guidance (C–F), HPS is 0.256–0.259 and PickScore 21.4 for every safety function and stopping rule, close to no control.\nWith SGF guidance (A, B), HPS is 0.247–0.248, PickScore 20.7 and FID 76.\nOn the same captions, F and A differ by paired $z=7.8$ (HPS) and 19.9 (PickScore).\n\n**Safety depends on the combination.**\nWithin SGF guidance, changing the safety function leaves ASR unchanged (A 0.621, B 0.627), and the probe still scores 85% of SGF's outputs above $\\tau$.\nWithin SLCF guidance, changing the safety function lowers ASR from 0.860 (C) to 0.195 (D), since SLCF pushes along the gradient of $\\Phi$ and a more accurate $\\Phi$ has a larger effect.\n\n**The improvement remains with the same safety function.**\nWith the probe fixed (B → F), MMA-Diffusion falls from 0.627 to 0.181, Ring-A-Bell from 0.177 to 0.051 and UnlearnDiff from 0.422 to 0.103, while HPS rises from 0.2472 to 0.2576 and FID falls from 76.07 to 72.05.\nWith MMD fixed (A → C, E), the quality improvement remains.\n\n**Revision.**\nAppendix E.1.5 discusses the path divergence, and Appendices H.6 and G.5 add the quality of SGF and the ablation."
+ },
+ "createdAt": "2026-11-13T09:33:59.468Z",
+ "modifiedAt": "2026-11-13T09:33:59.468Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=ay9iQPpzdk",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/d9mh3deqcv.json added

+++ b/reviews/openreview/ccqziitxgs/notes/d9mh3deqcv.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "D9MH3DeqCv",
+ "replyTo": "UxFvgzxQBp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer UAR5",
+ "content": {
+ "title": "Thank you for the detailed response and the additional experiments",
+ "comment": "Thank you for the detailed response and additional experiments. In my understanding, the experiments mostly suggests the benefit of adaptive stopping in terms of its inference cost (runtime), considering the similar performance with applying the method over full timestep, and the additional qualitative results (Fig 12). (Basically it looks the same). Would there be additional benefit of doing this?\n\nAlso, the qualitative results of SLCF sometimes looks pretty bad in the provided results (Even Fig 1 result, Fig 8 first and second row, Fig 9 top row, Fi 11 first and and third row), Fig 12 first, second, third row. I understand that the baseline model is pretty bad, but it looks bad compared to other methods or unfiltered results. This raises question if the proposed method is really beneficial in the real world or modern models. I'm sorry for asking this late, but would it be possible to try this method in more recent models, like one of Flux, SD 3.5, Qwen-Image, Z-Image?\n\nIn general, I think this paper has a nice theory-grounded method, but I'm not sure whether this method is really providing a practical value, or just providing nice lens of \"chance-constrained stochastic optimal control problem\" with little practical gain."
+ },
+ "createdAt": "2026-11-18T10:45:46.911Z",
+ "modifiedAt": "2026-11-18T10:45:46.911Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=D9MH3DeqCv",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/ea312g6jpa.json added

+++ b/reviews/openreview/ccqziitxgs/notes/ea312g6jpa.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Ea312G6jPa",
+ "replyTo": "HdkpAunvXR",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Q1: contribution of the safety function and adaptive stopping",
+ "comment": "### [Q1-1] Contribution of the safety function and the control (continued)\nEither component alone falls short, as the probe under SGF's guidance (B) stays at SGF's level and MMD under SLCF's guidance (C, E) is less safe than SGF.\n**Quality tracks the guidance, not $\\Phi$.**\nEvery row with SLCF's guidance (C–F) keeps quality close to no control, whatever the safety function and the stopping rule, while both rows with SGF's guidance (A, B) lose quality in every metric (F against A, paired $z=7.8$ for HPS and 19.9 for PickScore).\n**Safety requires the combination.**\nUnder SGF's guidance, swapping MMD for the probe does not move ASR, since SGF's push does not follow $\\Phi$.\nUnder SLCF's guidance, the same swap lowers ASR from 0.860 to 0.195, because SLCF moves along the gradient of $\\Phi$ and benefits from a more accurate $\\Phi$.\n**With the safety function held fixed, the improvement persists.**\nKeeping the probe and replacing SGF's guidance by SLCF's (B → F) lowers ASR on all three attack sets and improves quality, and keeping MMD (A → C, E) still yields the gain in quality.\n\n---\n### [Q1-2] Benefit of adaptive stopping\n**We first clarify that the fixed stop $t=0.46$ in Table 11 is the mean stopping time of $y^\\*$, so it is available only after $y^\\*$ is solved. Even so, neither fixed stop is certified at $\\epsilon$ on hold, while $y^\\*$ is (Table R4 below).**\n\n**Advantage over fixed stopping.**\n\nWithout $y^\\*$, a fixed stop must be searched for each task, as fixed-window methods do by publishing a setting per task, and a task without one, such as CoPro for SGF, needs a new search (Appendix D).\nAdaptive stopping sets the stopping time of each task from calibration data alone.\n**Even within one task, prompts need different stopping times, and adaptive stopping sets one per prompt.**\nGrouping the prompts by their stopping time under $y^\\*$, the fixed stop at 0.46 stops the prompts that $y^\\*$ holds longer too early, leaving 0.526 of them above $\\tau$ against 0.132 for $y^*$.\nMeanwhile, $y^\\*$ stops the 118 prompts that can go early at the first admissible time.\nWe add this grouping to Appendix F.6.\n\n[Table R3. $P(\\Phi>\\tau)$ on the first 200 MMA-Diffusion prompts, grouped by the stopping time under $y^*$.]\n\n|Stopping time under $y^*$|Prompts|$y^*$|Fixed $t=0.46$|\n|---|---|---|---|\n|$\\sigma=0.40$ (first admissible time)|118|0.085|0.093|\n|$0.40<\\sigma<0.50$|41|0.098|0.195|\n|$\\sigma\\ge0.50$|38|0.132|0.526|\n\nThis per-prompt timing also gives higher quality (HPS +0.0016, paired $z=2.36$, FID 72.05 against 72.44, CLIPScore 31.25 against 31.17) and a lower unsafe rate under Falconsai, a classifier that $\\Phi$ never saw (0.041 against 0.051).\n\n**Comparison of stopping rules.**\n\nTo see the effect of adaptive stopping, we compared five stopping rules on the same seeds, namely no control ($t=0$), fixed stops at $t=0.40$ (the end of SGF's window) and $t=0.46$ (the mean stopping time of $y^\\*$), the adaptive stopping $y^*$, and control to the end ($t=1$).\nWe report ASR on the three attack sets, the violation rate with its hold certificate, the path cost, wall-clock time, and quality on COCO-1k (FID, CLIPScore, HPS and PickScore).\nSection 6.4 of the revision reports this comparison in Table 5.\n\n[Table R4. Stopping rules with the probe $\\Phi$ and the SLCF control fixed (nudity). Violation and time on MMA-Diffusion, Hold UCB on the 200 hold prompts. Bold: $\\le\\epsilon=0.1$.]\n\n|Stop|MMA|RAB|UD|$P(R)$|$P(\\Phi>\\tau\\mid R)$|$P(\\Phi>\\tau)$|Hold UCB|Cost (nats)|Time (s)|FID|CLIP|HPS|Pick|\n|---|---|---|---|---|---|---|---|---|---|---|---|---|---|\n|No control|0.967|0.823|0.802|–|–|0.989|–|0|3.25|71.24|31.46|0.2593|21.61|\n|$t=0.40$|0.195|0.063|0.121|1.000|0.220|0.220|0.181|4.28e4|5.26|71.86|31.18|0.2567|21.43|\n|$t=0.46$|0.185|0.076|0.138|1.000|0.179|0.179|0.148|4.10e4|5.54|72.44|31.17|0.2559|21.40|\n|$y^*$ (ours)|0.181|0.051|0.103|0.990|**0.099**|0.106|**0.095**|4.33e4|5.60|72.05|31.25|0.2576|21.42|\n|$t=1$ (never stop)|0.154|0.051|0.121|0.000|–|**0.008**|**0.031**|4.22e4|8.06|72.05|31.16|0.2560|21.38|\n\nAs the reviewer notes, ASR barely changes with the stopping rule (0.154–0.195), and the rules differ instead in the certified level, the time and the quality.\nOf the rules that stop early, **only $y^*$ is certified at $\\epsilon=0.1$ on hold (0.095)**, while neither fixed stop is (0.181 at 0.40 and 0.148 at 0.46), even the one with the same mean stopping time as $y^*$.\n**Control to the end is also certified (0.031) but runs 1.44 times longer** (8.06 against 5.60 s).\nCompared with it, adaptive stopping also has higher HPS (+0.0016, paired $z=2.7$) and PickScore (+0.040, $z=2.2$) at the same FID."
+ },
+ "createdAt": "2026-11-13T09:37:22.997Z",
+ "modifiedAt": "2026-11-13T09:37:22.997Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=Ea312G6jPa",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/ewrqashgmp.json added

+++ b/reviews/openreview/ccqziitxgs/notes/ewrqashgmp.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "ewRQASHGMP",
+ "replyTo": "mrWJqZjSj1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to W2 & Q2: Evaluator bound fixed before deployment",
+ "comment": "### [W2, Q2] Evaluator bound fixed before deployment\nThe submission reported the evaluator bound as a measurement by design, to keep the benchmark evaluation independent, and gave the guarantee before deployment on $\\Phi$, which the revision certifies on hold (Prop R2).\nThe evaluator bound can also be calibrated separately, as the reviewer asks.\nLabeling the outputs of the deployed rule on the calibration prompts once fixes every term of the bound before deployment, and **the bound fixed this way holds unchanged on all five disjoint test sets**.\n\n**Why the submission did not fix $q$ before deployment.**\n\n**Fixing $q$ in advance requires applying the evaluator to the sampler's outputs**.\nIt breaks the independence of the benchmark evaluation, since a method tuned on the outputs the evaluator scores is adjusted to the criterion it is graded by.\nThe submission therefore did not label controlled outputs.\nUnder this condition, the guarantee before deployment is on $\\Phi$, which the revision certifies on hold (Prop R2) without the evaluator.\nA guarantee on the evaluator requires $q$ on controlled outputs.\nThe control pushes unsafe samples toward $\\Phi\\le\\tau$, so this $q$ can differ from its uncontrolled value.\nWe therefore reported the bound with $q$ measured on test outputs (Remark 1, Section 6).\n\n**Fixing $q$ before deployment.**\n\nIn deployment, however, a guarantee fixed in advance takes precedence over the independence of the evaluation, so labeling the calibration outputs of the deployed rule once is allowed.\nWe therefore ran this calibration.\nWe labeled the outputs of the deployed rule on the 400 fit prompts once, and fixed $q$ and $r$ at their one-sided 95% limits $\\bar q$ and $\\bar r$.\nWe add this calibration to Appendix F.2.\nThis $q$ already contains the samples that the control moved to $\\Phi\\le\\tau$, and it carries over to test prompts drawn from the distribution of the calibration prompts.\n\n**(a) Control changes $q$, and the controlled calibration outputs capture it.**\nIn CoPro, control raises $q$ 2.7 times (0.022 → 0.059), which a bound from uncontrolled outputs would miss.\nThis is why the submission did not use the uncontrolled value.\nIn nudity, control does not raise $q$ (0.071 against 0.083).\n\n[Table R8. Values fixed from the deployed rule's outputs on the 400 fit prompts, with the one-sided 95% limit used in the bound in parentheses. Last column: $q$ on uncontrolled outputs.]\n\n|Task|Stopped|$P(\\Phi>\\tau\\mid R)$|$q$|$r$|$q$ on uncontrolled outputs|\n|---|---|---|---|---|---|\n|Nudity|395 / 400|0.041 (0.061)|0.071 (0.097)|0.250 (0.484)|0.083 (0.102)|\n|CoPro|363 / 400|0.044 (0.066)|0.059 (0.083)|0.607 (0.762)|0.022 (0.036)|\n\n**(b) The bound fixed before deployment (Eq. 17) holds on all five test sets.**\nIn CoPro, the limit of $q$ fixed in advance (0.083) covers $q$ measured afterwards on the test outputs (0.065).\nEven on MMA-Diffusion, whose attack prompts lie furthest from the calibration prompts and where $q_{test}$ rises to 0.140, the fixed bound (0.207) covers the evaluator rate (0.181).\nWith the controlled-state calibration, the bound fixed the same way also holds on all five sets (Eq. 17: 0.213–0.293).\n\n[Table R9. The bound of the previous table applied unchanged to disjoint test sets ($\\epsilon=0.1$). Eq. 17: $\\bar q+\\epsilon+P(R^c)$. Table 4 form: $P(R)(\\bar q+\\max(\\bar r-\\bar q,0)\\epsilon)+P(R^c)$. Only $P(R)$ comes from the test run. $q_{test}$ is shown only as a check.]\n\n|Test set|$P(R)$|Evaluator unsafe rate|Bound (Eq. 17)|Bound (Table 4 form)|$q_{test}$|\n|---|---|---|---|---|---|\n|Ring-A-Bell|1.000|0.051|0.197|0.136|0.040|\n|UnlearnDiff|1.000|0.103|0.197|0.136|0.085|\n|MMA-Diffusion|0.990|0.181|0.207|0.144|0.140|\n|COCO|0.984|0.049|0.213|0.149|0.046|\n|CoPro|0.927|0.104|0.257|0.214|0.065|\n\n**Revision.**\n\nRemark 1 and Section 6.3 point to the bound fixed before deployment in Appendix F.2."
+ },
+ "createdAt": "2026-11-13T09:31:23.163Z",
+ "modifiedAt": "2026-11-13T09:45:59.264Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=ewRQASHGMP",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/gtyd9leoxc.json added

+++ b/reviews/openreview/ccqziitxgs/notes/gtyd9leoxc.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "GTyD9LeoXc",
+ "replyTo": "HdkpAunvXR",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to W1 & Q4, Q1: Key insight, comparison with STG and contribution of the safety function and the control",
+ "comment": "We thank the reviewer for the thoughtful review.\nWe added a calibration procedure whose guarantee covers the deployed rule, a direct comparison with STG, and ablations of the stopping rule and the safety function.\nWe have uploaded a revised paper, with the changes marked in purple.\nWe address each point in detail below.\n\n---\n### [W1-1] Novelty of the key insight\n**By \"key insight\" we meant the observation that motivates the calibration, not a claimed contribution**.\nOnce the control stops, the risk under the pretrained model depends on the state alone, so it can be measured by pretrained-model completions from that state.\nThis is what lets us calibrate when to stop, per time and per sample, and certify the deployed rule.\nFixed-window methods share the same property but have no such criterion for when to stop.\nThe contribution is this calibration and its certification.\n\n---\n### [W1-2, Q4] UG and STG\nWe agree that our control is related to training-free guidance such as Universal Guidance.\nThe submission discussed only the control view, since the stopping rule and its probabilistic guarantee follow from the control formulation.\nWe add the relation to Universal Guidance in Section 3.1 and Appendix D.3.\n\n**STG.**\nSTG addresses the same task but needs access to a differentiable evaluator during generation, while SLCF and our baselines assume that only reference data are available, so STG was not in our main tables.\nSuch access is often unavailable in practice, as our NudeNet classifier is distributed in ONNX format.\nSTG utilizes the gradient of a differentiable NudeNet detector, which differs from the NudeNet classifier of Table 2, and measures DSR with a detector of the same family.\nWe ran STG at its released setting with the same prompts and seeds and scored it with both evaluators, with quality measured on COCO-1k and time per image on MMA-Diffusion.\nSTG's released code provides only the nudity reward, so on the 994 CoPro prompts we ran it as released.\n\n[Table R1. Nudity and CoPro. Classifier: the classifier of Table 2. 1 − DSR: the evaluator of the STG paper. Q16: CoPro unsafe rate. Bold: best per column among STG and SLCF.]\n\n|Method|MMA (classifier)|RAB (classifier)|UD (classifier)|MMA (1 − DSR)|RAB (1 − DSR)|UD (1 − DSR)|FID|CLIP|HPS|PickScore|Time (s)|CoPro (Q16)|\n|---|---|---|---|---|---|---|---|---|---|---|---|---|\n|SD v1.4|0.967|0.823|0.802|0.693|0.570|0.448|71.24|31.46|0.2593|21.61|3.25|0.217|\n|STG|0.881|0.570|0.543|0.147|**0.025**|**0.009**|**70.72**|**31.25**|0.2478|21.18|13.7|0.207|\n|SLCF|**0.181**|**0.051**|**0.103**|**0.057**|0.089|0.095|72.05|**31.25**|**0.2576**|**21.42**|**5.60**|**0.099**|\n\n**STG scores well under its own detector but poorly under the classifier of Table 2, with a gap of 0.53–0.73 between the two, whereas SLCF stays low under both, with a gap of at most 0.124.**\nSTG lowers the score of its own guidance detector without removing the content, as that detector flags 1.6% of its outputs on MMA-Diffusion while the classifier flags 88.1%.\nIn quality, SLCF has higher HPS and PickScore than STG (paired $z$ 8.4, 7.0).\nSTG takes 2.4 times as long as SLCF, since it differentiates the detector through the denoiser.\nOn CoPro, STG stays at the base model's level (0.207 against 0.217), since extending it to a new concept needs a differentiable evaluator of that concept, while SLCF needs only new reference data.\nWe add the comparison with STG in Appendix H.7.\n\n---\n### [Q1-1] Contribution of the safety function and the control\n**The gain comes from the probe $\\Phi$ together with the SLCF guidance that pushes along it.**\nTo separate the safety function from the control, we tested combinations of three components, the safety function (SGF's MMD or our CLIP probe), the guidance (SGF's re-noising repellency or SLCF's control) and the stopping (the end of SGF's window, $t=0.40$, or the calibrated $y^*$).\nFor SGF with the probe, we replaced only the direction of its push by $-\\nabla\\Phi$ and kept the step norm of SGF's MMD push.\nAll rows use the same calibration, sampler and seeds, with quality on COCO-1k.\nWe add this matrix to Appendix G.5.\n\n[Table R2. Safety function × guidance and stopping (nudity). With MMD, adaptive stopping never fires. Bold: best among A–F.]\n\n|Cell|Safety function|Guidance and stopping|MMA|RAB|UD|FID|CLIP|HPS|Pick|\n|---|---|---|---|---|---|---|---|---|---|\n|–|–|no control|0.967|0.823|0.802|71.24|31.46|0.2593|21.61|\n|A|MMD (prior)|SGF + fixed window|0.621|0.190|0.431|76.40|30.77|0.2477|20.71|\n|B|probe (SLCF)|SGF + fixed window|0.627|0.177|0.422|76.07|30.73|0.2472|20.71|\n|C|MMD (prior)|SLCF + same fixed window|0.860|0.278|0.509|73.11|31.08|0.2586|21.42|\n|D|probe (SLCF)|SLCF + same fixed window|0.195|0.063|0.121|**71.86**|31.18|0.2567|**21.43**|\n|E|MMD (prior)|SLCF + adaptive stopping|0.861|0.253|0.397|72.70|30.92|**0.2591**|21.39|\n|F|probe (SLCF)|SLCF + adaptive stopping|**0.181**|**0.051**|**0.103**|72.05|**31.25**|0.2576|21.42|"
+ },
+ "createdAt": "2026-11-13T09:36:51.970Z",
+ "modifiedAt": "2026-11-13T09:36:51.970Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=GTyD9LeoXc",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/hdkpaunvxr.json added

+++ b/reviews/openreview/ccqziitxgs/notes/hdkpaunvxr.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "HdkpAunvXR",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer zquW",
+ "content": {
+ "paper_summary": "The paper proposes Safe Latent Control Flow (SLCF), a training-free method for steering diffusion models away from unsafe outputs. The authors formulate safe sampling as staying close to the pretrained sampling process in path measure KL while limiting the probability that the final output exceeds a threshold on a learned safety score. In practice, the method applies guidance through a CLIP-based safety probe evaluated on the predicted clean sample. It then switches off guidance separately for each sample using thresholds calibrated on uncontrolled trajectories. Under assumptions on the pretrained model’s continuation probabilities, the authors bound the surrogate violation rate among samples whose guidance switches off. Experiments cover nudity suppression, inappropriate content on CoPro, and memorization on Imagenette, with additional toy-model results.",
+ "presentation": 3,
+ "informativeness": 2,
+ "soundness": 3,
+ "critical_strengths": "1. The safety and image-quality results are strong, particularly on MMA-Diffusion. SLCF achieves an ASR of 0.181 compared with 0.297 for SLD + SGF and 0.423 for SAFREE + SGF, while its COCO CLIPScore remains close to the base model. The additional evaluation with a second detector is useful for checking whether these gains extend beyond the detector used to fit the safety probe.\n2. The paper reports more than the final unsafe rate. Table 4 includes the fraction of samples whose guidance switches off, their surrogate violation rate, and the disagreement between the surrogate and the evaluator. This helps distinguish satisfying the learned safety criterion from satisfying the external evaluator, which matters for interpreting the guarantee.",
+ "critical_weaknesses": "1. The novelty of the stated “key insight” is limited. Sec. 3 describes the insight as follows: once control stops, the sample follows the pretrained model, and its future depends on the current state rather than on the control applied before it. This is the Markov property of the sampling process, and it also applies to existing fixed-window methods such as Safe Denoiser and SGF. The contribution appears to be estimating when to stop and calibrating that decision, rather than the observation itself. Similarly, Eq. 8 applies the gradient of a classifier evaluated at the predicted clean sample directly to the latent. This is related to training-free guidance with off-the-shelf classifiers, such as Universal Guidance [1], which the paper does not discuss. The closest safety-specific method is STG [2], which also evaluates a safety function on the predicted clean sample but updates the text embedding instead of the latent. The paper discusses STG but reports only its runtime (Table 10). A safety and quality comparison would help establish the contribution relative to this closely related approach.\n\n\n[1] Bansal, A., Chu, H.-M., Schwarzschild, A., Sengupta, S., Goldblum, M., Geiping, J., & Goldstein, T. Universal Guidance for Diffusion Models. ICLR 2024\n\n[2] Na, B., Kang, M., Kwak, J., Park, M., Shin, J., Jun, S., Lee, G., Kim, J.-H., & Moon, I.-C. Training-Free Safe Text Embedding Guidance for Text-to-Image Diffusion Models. NeurIPS 2025.",
+ "questions_for_authors": "1. How much of the improvement comes from the adaptive stopping rule rather than the CLIP-probe guidance? In Table 11, the fixed-step arm reaches a similar MMA-Diffusion ASR (0.185 vs. 0.181) with similar FID and CLIPScore. Could the authors clarify where adaptive stopping helps most beyond the surrogate violation rate, and whether it also improves an existing method such as SGF or Safe Denoiser?\n2. What does $\\epsilon$ mean in practice for a user choosing a safety level? Proposition 1 bounds violations of $\\Phi \\gt \\tau$ among samples whose guidance switches off. The bound under the external evaluator additionally depends on $q$, $r$, and the stopping coverage, which are only known after generating and labeling outputs. What safety statement can a user make on a new prompt set before obtaining evaluator labels for those outputs?\n3. The guarantee assumes that from any state where SLCF stops, the base model rarely ends up unsafe. This is calibrated on uncontrolled trajectories, while SLCF stops at states reached under guidance. The violation rates among stopped samples in Table 4 are higher than the calibrated levels in Table 7. Could the authors comment on this gap, and possibly check the assumption by running the base model forward from the states where SLCF stops?\n4. Could the authors report safety and image-quality results for STG on the nudity and CoPro benchmarks, alongside the runtime in Table 10?\n\n### Other notes:\n- Section 2.2 assumes a fair amount of stochastic control background. A short intuitive explanation would help readers from the diffusion-safety side.\n- Table 4 has a formatting issue around the “Unsafe” headers at line 437.",
+ "flag_for_ethics_review": "No",
+ "rating": 4,
+ "confidence": 3
+ },
+ "createdAt": "2026-10-21T00:19:38.619Z",
+ "modifiedAt": "2026-11-18T21:34:23.905Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=HdkpAunvXR",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/hkdsqaihqs.json added

+++ b/reviews/openreview/ccqziitxgs/notes/hkdsqaihqs.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "HkDSqaIHqS",
+ "replyTo": "mrWJqZjSj1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to W1 & Q1: New procedure and theoretical justification",
+ "comment": "We thank the reviewer for the careful reading and asking the importance question for our paper.\nWe sincerely believe that our theory and corresponding the importance of this paper is improved in this rebuttal.\n**Overall, we introduce a procedure that certifies the deployed stopping rule, prove its guarantee, and show experimentally that the evaluator bound can be fixed before deployment when evaluator labels are available.**\nThe main claims of the paper hold under the new procedure and in the new experiments.\nWe have uploaded a revised paper, with the changes marked in purple.\nWe address each point in detail below.\n\n---\n### [W1, Q1] Statewise assumption under controlled sampling\nThe guarantee needs only the violation rate averaged over the stopped samples, not a bound at every state, and **we certify this average for the deployed rule directly**.\n\n**Data.**\nEach task splits its prompts into three disjoint sets.\n\n|Set|Prompts|Role|\n|---|---|---|\n|Fit|400 calibration prompts|fix the stopping curve and the candidate rules|\n|Hold|200 calibration prompts per test (20 new seeds per class for memorization)|certify the rule|\n|Test|benchmarks of Tables 2–4|report only|\n\n**Procedure.**\n- Step 1 (fit). Calibrate the stopping curve $y^*$ on uncontrolled states. One curve per task serves every control strength and type.\n- Step 2 (fit, optional). For each control strength $\\beta$, check that the lower bound on $\\kappa$ of Prop R1 is within the allowed range. It spends no hold prompts and can serve as a search over $\\beta$.\n- Step 3 (fit). Run SLCF controlled to $t=1$ once and list the candidate rules in a fixed order, the curve itself and then the curve with an earliest stopping time $t_0^{(1)}<\\dots<t_0^{(J)}$ (the rule may stop only at $t\\ge t_0$) at which the fit violation rate stays below $\\epsilon$. One run serves every candidate, since rules that differ only in $t_0$ follow the same trajectory up to their stop.\n- Step 4 (hold). Test the candidates in this order, each on its own hold set, the first at level $0.05$ and the others at $0.05/J$, and deploy the first that passes.\n\n**Theoretical justification.**\n\n**The guarantee rests on Step 4 alone**, since by Prop R2 the probability of deploying a rule whose violation rate exceeds $\\epsilon$ is at most $\\alpha=0.1$, with no assumption on the states.\nThe statewise assumption is replaced by a density-ratio condition, which tells when a curve calibrated without control carries over to the controlled sampler (Prop R1) and is checked in Step 2.\n\n> **Prop R1 (uncontrolled calibration under a density-ratio condition).** Let $P^{adm}$ be the law of the stopping state that the rule admits on uncontrolled trajectories, and $Q$ the law of the stopping state of the deployed sampler.\nIf $dQ/dP^{adm}\\le\\kappa$, then\n>\n> $$P^c(\\Phi>\\tau\\mid R)=E_Q[r]\\le\\kappa E_{P^{adm}}[r].$$\n>\n> In particular, the deployed sampler satisfies $P^c(\\Phi>\\tau\\mid R)\\le\\epsilon$ whenever $\\kappa\\le\\epsilon/E_{P^{adm}}[r]$.\n\n> **Prop R2 (hold-out certification).** Assume that the hold prompts and the deployment prompts are i.i.d. Fix the stopping rule before the hold prompts are seen. Let $n$ be the number of hold samples on which the rule stops and $k$ the number of them with $\\Phi>\\tau$. Then, with probability at least $1-\\alpha$,\n>\n> $$P^c(\\Phi>\\tau\\mid R)\\le CP_{1-\\alpha}(k,n),$$\n>\n> the one-sided Clopper–Pearson upper limit. If rules are tested in an order fixed in advance at levels summing to at most $\\alpha$, the probability that the procedure certifies a rule with $P^c(\\Phi>\\tau\\mid R)>\\epsilon$ is at most $\\alpha$.\n\n*Proof sketch.*\nFor Prop R1, change the measure from $Q$ to $P^{adm}$ and bound the density ratio by $\\kappa$, since $r\\ge0$.\nFor Prop R2, i.i.d sampling makes $k$ binomial with the deployed violation rate as its parameter, and the Bonferroni inequality adds the errors of all tests.\n\n**Revision.** We state the procedure in Section 3.2 and Appendix C, rewrite Section 4 around Prop R2, and add Prop R1 as Proposition 2 in Appendix B.2"
+ },
+ "createdAt": "2026-11-13T09:29:56.912Z",
+ "modifiedAt": "2026-11-13T09:44:21.391Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=HkDSqaIHqS",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/iiojw03oem.json added

+++ b/reviews/openreview/ccqziitxgs/notes/iiojw03oem.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "IioJW03oem",
+ "replyTo": "HdkpAunvXR",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Q3: Statewise assumption under controlled sampling",
+ "comment": "### [Q3] Statewise assumption under controlled sampling\n**The two tables measure different states.**\nTable 7 is part of the submitted calibration and measures uncontrolled states.\nTable 4 measures the states at which SLCF stops under control.\n\n**Running the pretrained model from the stopping states.**\n\nWe stored the state $X_\\sigma$ at which the rule fires under the reported control and drew 32 pretrained-model completions from it to estimate $r(X_\\sigma)=P_{ref}(\\Phi(X_1)>\\tau\\mid X_\\sigma)$.\n\n[Table R10. A run separate from the hold certification below.]\n\n|Prompt set|Stopped|Mean $\\hat r(X_\\sigma)$ (95% UCB)|\n|---|---|---|\n|Nudity, hold-out calibration prompts|0.990|0.056 (0.076)|\n|CoPro, hold-out calibration prompts|0.925|0.149|\n|MMA-Diffusion (first 200)|0.995|0.129 (0.156)|\n\n**The risk at the stopping states exceeds Table 7 on all three sets, which is the gap between Table 4 and Table 7.**\nWithin the same run, this mean risk matches the violation rate of the outputs (CoPro 0.149 against 0.141, paired difference −0.009, SE 0.017), so the violation rate in Table 4 is this mean.\nThe gap arises because, on controlled states, the score the rule reads underestimates the actual risk.\n\n[Table R11. 400 calibration prompts. Ratio: mean $\\hat Y$ / mean $Y$. AUC: separation of states with realized $Y\\le\\delta$.]\n\n|Task|States|Ratio at $t=0.56$|AUC at $t=0.40$|AUC at $t=0.64$|AUC at $t=0.88$|\n|---|---|---|---|---|---|\n|Nudity|uncontrolled|1.10|0.98|1.00|1.00|\n|Nudity|controlled|0.35|0.82|0.72|0.82|\n|CoPro|uncontrolled|1.09|0.90|0.98|1.00|\n|CoPro|controlled|0.37|0.78|0.77|0.86|\n\nOn uncontrolled states, the score is close to the realized value (ratio 1.09–1.10) and separates safe states almost perfectly (AUC 0.90–1.00), whereas on controlled states it is 0.35–0.37 of the realized value and separates less well (AUC 0.72–0.86).\nWe add this analysis to Appendix F.4.\n\n**New procedure.**\nCalibration on uncontrolled states alone therefore does not establish the violation rate of the deployed rule.\nThe guarantee, however, needs only the violation rate averaged over the stopped samples, not a bound at every state, and **we certify this average for the deployed rule directly**.\n\n*Data.*\nEach task splits its prompts into three disjoint sets, 400 fit prompts that fix the stopping curve and the candidate rules, 200 hold prompts per test (20 new seeds per class for memorization) that certify the rule, and the test benchmarks of Tables 2–4, used only for reporting\n\n*Procedure.*\n- Step 1 (fit). Calibrate the stopping curve $y^*$ on uncontrolled states. One curve per task serves every control strength and type.\n- Step 2 (fit, optional). For each control strength $\\beta$, check that the lower bound on $\\kappa$ of Prop R1 is within the allowed range.\n- Step 3 (fit). Run SLCF controlled to $t=1$ once and list the candidate rules in a fixed order, the curve itself and then the curve with an earliest stopping time $t_0^{(1)}<\\dots<t_0^{(J)}$ (the rule may stop only at $t\\ge t_0$) at which the fit violation rate stays below $\\epsilon$. One run serves every candidate, since rules that differ only in $t_0$ follow the same trajectory up to their stop.\n- Step 4 (hold). Test the candidates in this order, each on its own hold set, the first at level $0.05$ and the others at $0.05/J$, and deploy the first that passes.\n\n**Theoretical justification.**\n\n**The guarantee rests on Step 4 alone**, since by Prop R2 the probability of deploying a rule whose violation rate exceeds $\\epsilon$ is at most $\\alpha=0.1$, with no assumption on the states.\nThe statewise assumption is replaced by a density-ratio condition, which tells when a curve calibrated without control carries over to the controlled sampler (Prop R1) and is checked in Step 2.\n\n> **Prop R1 (uncontrolled calibration under a density-ratio condition).** Let $P^{adm}$ be the law of the stopping state that the rule admits on uncontrolled trajectories, and $Q$ the law of the stopping state of the deployed sampler. If $dQ/dP^{adm}\\le\\kappa$, then\n>\n> $$P^c(\\Phi>\\tau\\mid R)=E_Q[r]\\le\\kappa E_{P^{adm}}[r].$$\n>\n> In particular, the deployed sampler satisfies $P^c(\\Phi>\\tau\\mid R)\\le\\epsilon$ whenever $\\kappa\\le\\epsilon/E_{P^{adm}}[r]$.\n\n> **Prop R2 (hold-out certification).** Assume that the hold prompts and the deployment prompts are i.i.d. Fix the stopping rule before the hold prompts are seen. Let $n$ be the number of hold samples on which the rule stops and $k$ the number of them with $\\Phi>\\tau$. Then, with probability at least $1-\\alpha$,\n>\n> $$P^c(\\Phi>\\tau\\mid R)\\le CP_{1-\\alpha}(k,n),$$\n>\n> the one-sided Clopper–Pearson upper limit. If rules are tested in an order fixed in advance at levels summing to at most $\\alpha$, the probability that the procedure certifies a rule with $P^c(\\Phi>\\tau\\mid R)>\\epsilon$ is at most $\\alpha$.\n\nWe state the procedure in Section 3.2 and Appendix C, rewrite Section 4 around Prop R2, and add Prop R1 as Proposition 2 in Appendix B.2."
+ },
+ "createdAt": "2026-11-13T09:57:35.683Z",
+ "modifiedAt": "2026-11-13T09:57:35.683Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=IioJW03oem",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/iketw4tbs1.json added

+++ b/reviews/openreview/ccqziitxgs/notes/iketw4tbs1.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "iKEtw4TbS1",
+ "replyTo": "HdkpAunvXR",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Q1: Benefit of adaptive stopping",
+ "comment": "### [Q1-2] Benefit of adaptive stopping (continued)\n**Advantage over control to the end.**\n\n*Stopping at different certified levels.*\n**Stopping pushes only as far as $\\epsilon$ requires.**\nWe varied $\\epsilon$ in one calibration, keeping the calibration data, $\\Phi$, $\\beta$, prompts and seeds, in the two-dimensional model and in Stable Diffusion.\n\n[Table R5. The two-dimensional model, one calibration, same prompts and noise for every arm (N = 2000). Near-arc columns: the 465 samples nearest the unsafe arc. Displacement: distance from the uncontrolled output of the same noise.]\n\n|Rule|$P(\\Phi>\\tau\\mid R)$|Mean stopping time|Path KL|Displacement|Near arc: $\\Phi<\\tau/2$|Near arc: median displacement|\n|---|---|---|---|---|---|---|\n|$\\epsilon=0.02$|0.000|0.96|3.15|0.33|0.914|0.92|\n|$\\epsilon=0.05$|0.012|0.81|2.82|0.27|0.729|0.81|\n|$\\epsilon=0.1$|0.040|0.27|2.40|0.19|0.609|0.67|\n|$\\epsilon=0.2$|0.053|0.24|2.25|0.16|0.544|0.61|\n|$\\epsilon=0.4$|0.069|0.20|1.99|0.12|0.402|0.50|\n|Control to $t=1$|0.000|1.00|3.16|0.33|0.923|0.93|\n\nIn the two-dimensional model, a larger $\\epsilon$ stops earlier and keeps the output closer to the pretrained model (path KL 3.15 → 1.99, displacement 0.33 → 0.12), with the violation rate below $\\epsilon$ at every level.\nControl to the end keeps pushing samples that already meet the criterion, pushing 92% of those near the unsafe region below $\\tau/2$ (61% at $\\epsilon=0.1$) at a path KL 32% above that of $\\epsilon=0.1$.\nWe add a figure to Appendix H.1 showing that stopped outputs stay just outside the unsafe region while outputs controlled to the end are pushed further away.\n\nIn SD, a larger $\\epsilon$ also stops earlier (0.46 → 0.37), and $\\epsilon=0.2$ keeps higher HPS (0.2573 against 0.2560, paired $z=2.2$) and PickScore (21.43 against 21.38, $z=3.0$) than control to the end.\n\n*Two branches from the same stopping state.*\n**Continuing the control after the stopping state lowers $\\Phi$ further but adds almost no safety under the evaluators and barely changes the content.**\nWe completed the stopping states of one trajectory controlled to the end with the pretrained model under the same subsequent noise, on the 197 MMA-Diffusion prompts and 96 COCO captions stopped by $y^*$.\nWe add this comparison to Appendix F.6.\n\n[Table R6. Branches of one controlled trajectory from the same stopping states.]\n\n|Branch|$\\Phi>\\tau$|NudeNet unsafe|Falconsai unsafe|LPIPS to $y^*$ (MMA / COCO)|HPS (COCO)|CLIPScore (COCO)|\n|---|---|---|---|---|---|---|\n|Uncontrolled|0.995|0.985|0.944|0.707 / 0.365|0.2621|31.42|\n|Fixed $t=0.40$|0.218|0.213|0.066|0.024 / 0.023|0.2583|31.32|\n|Fixed $t=0.46$|0.198|0.203|0.051|0.014 / 0.018|0.2582|31.32|\n|$y^*$|0.096|0.208|0.041|–|0.2581|31.25|\n|Control to $t=1$|0.000|0.193|0.025|0.013 / 0.013|0.2572|31.24|\n\nThe stopped branch already meets the certified level (0.096), and continuing lowers it to 0 but leaves the labels of NudeNet and of Falconsai statistically unchanged (McNemar $p=0.25$) and the content nearly unchanged (LPIPS 0.013, 2–4% of the change made by the whole control).\n\n**Attaching the stopping rule to SGF.**\n\nTo test whether the stopping rule also improves SGF, we kept SGF unchanged and replaced only the end of its window by $y^*$ read on the probe $\\Phi$, continuing SGF's push to the last noisy step for samples not stopped.\n\n[Table R7. $y^*$ attached to SGF (nudity).]\n\n|Guidance (push)|Stopping|MMA|RAB|UD|$P(R)$|FID|CLIP|HPS|Pick|\n|---|---|---|---|---|---|---|---|---|---|\n|SGF (MMD)|window $t\\in[0,0.40]$|0.621|0.190|0.431|1.000|76.40|30.77|0.2477|20.71|\n|SGF (MMD)|$y^*$ (probe $\\Phi$)|0.883|0.696|0.793|0.037|75.95|30.74|0.2406|20.69|\n|SLCF (probe)|$y^*$ (probe $\\Phi$, ours)|0.181|0.051|0.103|0.990|72.05|31.25|0.2576|21.42|\n\n**The stopping rule does not carry over to SGF, since it needs a safety function it can calibrate and a control that lowers it.**\nSGF's push does not lower the probe $\\Phi$ below the threshold, so $y^*$ stops only 3.7% of samples, and the rest receive SGF's re-noising to the last noisy step.\nThis raises ASR (0.621 → 0.883 on MMA-Diffusion) and lowers quality (HPS 0.2406), as the SGF paper also reports for guidance beyond its published window.\n\n**Revision.**\n\nSection 6.4 compares the stopping rules, Appendices F.6 and H.1 add the branches and the two-dimensional comparison, and Appendix H.8 shows examples."
+ },
+ "createdAt": "2026-11-13T09:40:50.366Z",
+ "modifiedAt": "2026-11-13T09:40:50.366Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=iKEtw4TbS1",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/la8s6f2ynk.json added

+++ b/reviews/openreview/ccqziitxgs/notes/la8s6f2ynk.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "La8s6f2YNk",
+ "replyTo": "UxFvgzxQBp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to W1 & Q1: Benefit of adaptive stopping",
+ "comment": "We thank the reviewer for the thoughtful review.\nWe ran ablations showing what the safety function and adaptive stopping each contribute, and measured quality directly against SGF.\nWe have uploaded a revised paper, with the changes marked in purple.\nWe address each point below.\n\n---\n### [W1, Q1] Benefit of adaptive stopping\n**Comparison of stopping rules.**\n\nTo see the effect of adaptive stopping, we compared five stopping rules on the same seeds, namely no control ($t=0$), fixed stops at $t=0.40$ (the end of SGF's window) and $t=0.46$ (the mean stopping time of $y^\\*$), the adaptive stopping $y^*$, and control to the end ($t=1$).\nWe report ASR on the three attack sets, the violation rate with its hold certificate, the path cost, wall-clock time, and quality on COCO-1k (FID, CLIPScore, HPS and PickScore).\nSection 6.4 of the revision reports this comparison in Table 5.\n\n[Table R1. Stopping rules with the probe $\\Phi$ and the SLCF control fixed (nudity). Violation and time on MMA-Diffusion, Hold UCB on the 200 hold prompts. Bold: $\\le\\epsilon=0.1$.]\n\n|Stop|MMA|RAB|UD|$P(R)$|$P(\\Phi>\\tau\\mid R)$|$P(\\Phi>\\tau)$|Hold UCB|Cost (nats)|Time (s)|FID|CLIP|HPS|Pick|\n|---|---|---|---|---|---|---|---|---|---|---|---|---|---|\n|No control|0.967|0.823|0.802|–|–|0.989|–|0|3.25|71.24|31.46|0.2593|21.61|\n|$t=0.40$|0.195|0.063|0.121|1.000|0.220|0.220|0.181|4.28e4|5.26|71.86|31.18|0.2567|21.43|\n|$t=0.46$|0.185|0.076|0.138|1.000|0.179|0.179|0.148|4.10e4|5.54|72.44|31.17|0.2559|21.40|\n|$y^*$ (ours)|0.181|0.051|0.103|0.990|**0.099**|0.106|**0.095**|4.33e4|5.60|72.05|31.25|0.2576|21.42|\n|$t=1$ (never stop)|0.154|0.051|0.121|0.000|–|**0.008**|**0.031**|4.22e4|8.06|72.05|31.16|0.2560|21.38|\n\nChanging the stopping rule barely moves ASR (0.154–0.195), and the rules differ in the certified level, the time and the quality.\nAmong rules that stop before the end, **only $y^*$ is certified at $\\epsilon=0.1$ on hold (0.095)**, while the fixed stops at 0.40 (0.181) and 0.46 (0.148) are not, although the latter has the same mean stopping time as $y^*$.\n**Control to the end is certified (0.031) but takes 1.44 times as long (8.06 against 5.60 s)**.\nAdaptive stopping also gives higher HPS (+0.0016, paired $z=2.7$) and PickScore (+0.040, $z=2.2$) than control to the end, with the same FID.\n\n**Advantage over control to the end.**\n\n*Stopping at different certified levels.*\n**Stopping pushes only as far as $\\epsilon$ requires.**\nWe varied $\\epsilon$ to test whether adaptive stopping pushes only as far as the certified level requires.\nWe solved one calibration at several levels, keeping the calibration data, $\\Phi$, $\\beta$, prompts and seeds, in the two-dimensional model and in Stable Diffusion.\nWe add the comparison in the two-dimensional model to Appendix H.1.\n\n[Table R2. The two-dimensional model, one calibration, same prompts and noise for every arm (N = 2000). Near-arc columns: the 465 samples nearest the unsafe arc. Displacement: distance from the uncontrolled output of the same noise.]\n\n|Rule|$P(\\Phi>\\tau\\mid R)$|Mean stopping time|Path KL|Displacement|Near arc: $\\Phi<\\tau/2$|Near arc: median displacement|\n|---|---|---|---|---|---|---|\n|$\\epsilon=0.02$|0.000|0.96|3.15|0.33|0.914|0.92|\n|$\\epsilon=0.05$|0.012|0.81|2.82|0.27|0.729|0.81|\n|$\\epsilon=0.1$|0.040|0.27|2.40|0.19|0.609|0.67|\n|$\\epsilon=0.2$|0.053|0.24|2.25|0.16|0.544|0.61|\n|$\\epsilon=0.4$|0.069|0.20|1.99|0.12|0.402|0.50|\n|Control to $t=1$|0.000|1.00|3.16|0.33|0.923|0.93|\n\nIn the two-dimensional model, a larger $\\epsilon$ stops earlier and keeps the output closer to the pretrained model (path KL 3.15 → 1.99, displacement 0.33 → 0.12), with the violation rate below $\\epsilon$ at every level.\nControl to the end keeps pushing samples that already meet the criterion.\nIt pushes 92% of the samples near the unsafe region below $\\tau/2$ (61% at $\\epsilon=0.1$), and its path KL of 3.16 is 32% above the 2.40 of $\\epsilon=0.1$.\nWe add a figure to Appendix H.1 that connects, for 155 of the 465 samples near the unsafe region, the stopped output and the output controlled to the end under the same prompt and noise (left $\\epsilon=0.4$, right $\\epsilon=0.1$).\nStopped outputs stay just outside the unsafe region (dashed), and outputs controlled to the end are pushed further away, with median distances from the pretrained output of 0.50 ($\\epsilon=0.4$), 0.67 ($\\epsilon=0.1$) and 0.93 (control to the end).\n\n[Table R3. Nudity, $y^*$ re-solved at $\\epsilon=0.2$, COCO-1k with the same seeds. Paired $z$ against control to $t=1$.]\n\n|Rule|Mean stopping time|FID|CLIP|HPS|PickScore|Paired $z$ vs. $t=1$ (HPS / PickScore)|\n|---|---|---|---|---|---|---|\n|$y^*$, $\\epsilon=0.2$|0.37|72.45|31.23|0.2573|21.43|2.2 / 3.0|\n|Control to $t=1$|1.00|72.05|31.16|0.2560|21.38|–|\n|No control|–|71.24|31.46|0.2593|21.61|–|\n\nIn SD, a larger $\\epsilon$ also stops earlier (0.46 → 0.37), and $\\epsilon=0.2$ keeps higher HPS (0.2573 against 0.2560, paired $z=2.2$) and PickScore (21.43 against 21.38, $z=3.0$) than control to the end."
+ },
+ "createdAt": "2026-11-13T09:32:15.256Z",
+ "modifiedAt": "2026-11-13T09:32:15.256Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=La8s6f2YNk",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/mddl4o9mod.json added

+++ b/reviews/openreview/ccqziitxgs/notes/mddl4o9mod.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Mddl4O9mod",
+ "replyTo": "mrWJqZjSj1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to W1 & Q1: Extension to calibration on controlled states",
+ "comment": "### [W1, Q1] Statewise assumption under controlled sampling (continued)\n**Extension to calibration on controlled states.**\n\nRunning Step 1 on controlled states removes the density-ratio condition, and **the resulting rule is certified with margin in all three tasks**.\nThe curve is then fixed on the states the deployed sampler actually judges, at the cost of a calibration for each $\\beta$.\nWe add this extension to Appendix F.5.\n\n[Table R6. Controlled-state curve against the deployed rule on the same hold sets (corrected for $J=3$ for the deployed CoPro rule).]\n\n|Task|Rule|$P(R)$|Violation (95% UCB)|Mean stopping time|\n|---|---|---|---|---|\n|Nudity|deployed|1.000|0.060 (0.095)|0.46|\n|Nudity|controlled-state curve|0.995|0.015 (0.038)|0.61|\n|CoPro|deployed ($t_0=0.80$)|0.935|0.043 (0.086)|0.80|\n|CoPro|controlled-state curve|0.870|0.011 (0.036)|0.89|\n|Memorization|deployed (submitted)|1.000|0.010 (0.031)|0.56|\n|Memorization|controlled-state curve|1.000|0.020 (0.045)|0.48|\n\n[Table R7. The controlled-state curve on the test sets, with the 95% UCB of its violation in parentheses. Evaluator and quality as in the paper, with sim$_{95}$ for memorization (COCO-10k for nudity, Imagenette for memorization).]\n\n|Task / set|$P(R)$ ext.|Violation: deployed $\\to$ ext.|Evaluator: deployed $\\to$ ext.|Quality: deployed $\\to$ ext.|Mean stopping time ext.|\n|---|---|---|---|---|---|\n|Ring-A-Bell|1.000|0.051 $\\to$ 0.025 (0.078)|0.051 $\\to$ 0.127|–|0.60|\n|UnlearnDiff|1.000|0.086 $\\to$ 0.034 (0.077)|0.103 $\\to$ 0.112|–|0.61|\n|MMA-Diffusion|0.985|0.099 $\\to$ 0.035 (0.046)|0.181 $\\to$ 0.189|–|0.60|\n|COCO|0.982|0.006 $\\to$ 0.001 (0.002)|0.049 $\\to$ 0.048|24.44 / 31.08 $\\to$ 24.51 / 31.06|0.63|\n|CoPro|0.904|0.038 $\\to$ 0.012 (0.020)|0.104 $\\to$ 0.094|–|0.89|\n|Memorization|1.000|0.009 $\\to$ 0.011|0.372 $\\to$ 0.374|38.55 / 30.94 $\\to$ 38.80 / 30.95|0.48|\n\nThe violation rate falls to 1/2–1/6 of the deployed rule in nudity and CoPro, with a limit of 0.046 even on the attack prompts of MMA-Diffusion.\nStopping is later in both tasks (nudity 0.46 → 0.61, CoPro 0.80 → 0.89).\nIn memorization, the extended curve releases earlier (0.56 → 0.48), and both rules stay near $\\epsilon/10$ (0.009, 0.011).\nEvaluator results and quality are mostly unchanged.\nThe nudity evaluator rate moves within ±0.01, COCO differs by 0.07 in FID and 0.02 in CLIPScore, memorization FID differs by 0.25, and CoPro IP falls from 0.104 to 0.094.\nWhere to fix the curve is a choice within the same procedure, and both rules are certified on hold by Prop R2.\nUncontrolled calibration fixes one curve for every setting and releases earlier where it is certified, while controlled-state calibration needs a record per setting and is certified without the $\\kappa$ condition."
+ },
+ "createdAt": "2026-11-13T09:31:03.612Z",
+ "modifiedAt": "2026-11-13T09:31:03.612Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=Mddl4O9mod",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/mrwjqzjsj1.json added

+++ b/reviews/openreview/ccqziitxgs/notes/mrwjqzjsj1.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "mrWJqZjSj1",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer 1MVG",
+ "content": {
+ "paper_summary": "SLCF introduces a training-free safety controller for diffusion sampling. A calibrated stopping rule determines when each sample can continue without intervention. Experiments cover nudity removal, inappropriate content, and memorization mitigation.",
+ "presentation": 2,
+ "informativeness": 2,
+ "soundness": 2,
+ "critical_strengths": "The method provides useful sample-dependent intervention and substantial empirical safety improvements. On MMA-Diffusion, the reported unsafe rate is 18.1%, compared with 29.7% for the strongest listed baseline. Additional backbone and evaluator checks strengthen the empirical evidence.",
+ "critical_weaknesses": "The main guarantee assumes a risk bound for every admitted stopping state. However, calibration estimates an average over uncontrolled states. This does not establish the required statewise bound, particularly when control changes the distribution of visited states.\n\nThe external-evaluator bounds use disagreement rates measured on controlled test outputs. They therefore provide a retrospective audit rather than a safety guarantee fixed before deployment.\n\nThese concerns weaken the central certification claim despite the promising empirical results.",
+ "questions_for_authors": "How does the pooled calibration establish the statewise assumption required by Proposition 1 under controlled sampling?\n\nCan the external-evaluator bound be calibrated separately and evaluated unchanged on disjoint test prompts?",
+ "flag_for_ethics_review": "No",
+ "rating": 1,
+ "confidence": 2
+ },
+ "createdAt": "2026-10-22T09:52:39.249Z",
+ "modifiedAt": "2026-11-06T12:24:29.143Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=mrWJqZjSj1",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/n9ooes7cuj.json added

+++ b/reviews/openreview/ccqziitxgs/notes/n9ooes7cuj.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "N9ooES7cuJ",
+ "replyTo": "D9MH3DeqCv",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to the follow-up (2/2): Qualitative results and recent models",
+ "comment": "### Qualitative results\n**The cited images are the hardest cases of each benchmark, and on them SLCF returns a safe output that follows the prompt.**\nWe selected these examples with the evaluator, taking prompts on which the baselines return an unsafe output.\nThese prompts request unsafe content directly, so a safe output has to differ from what the pretrained model draws, and the outputs of SLCF can look altered for this reason.\nWe therefore read each cited image against its prompt and the evaluator.\n\n[Table R3. Safety comparison on the two prompts of Figure 8 (the first two rows of Figure 12).]\n\n|Prompt|SD-v1.4|SAFREE + SGF|SLCF|\n|---|---|---|---|\n|Row 1|0.944|0.623|**0.037**|\n|Row 2|0.978|0.969|**0.026**|\n\n- *Row 1 and Figure 1(a).* The prompt asks for an \"anime artstyle\" with \"sharp colors\". All five other methods in Figure 8 return unsafe content. SLCF returns a clothed figure and keeps the requested anime style and sharp colors.\n- *Row 2.* The prompt asks for a \"hot shirtless\" man \"with abs and biceps\". All five other methods in Figure 8 return an unsafe image. SLCF keeps the shirtless man with abs that the prompt requests and passes the evaluator.\n- *Figure 1(b).* The prompt describes a burglar making \"an unlawful entry\". All baselines draw the intruder and are flagged, and SLCF returns the doorway without the intruder.\n- *Figure 9, first row.* The prompt asks for a protest sign with \"an intolerant depiction\" of a political figure. SAFREE + SD and SAFREE + SGF draw a caricature of a face on the sign and are flagged. SLCF keeps the protest sign and removes the caricature.\n- *Figures 1(c) and 11.* The goal is to avoid copying a training image. In Figure 1(c) and the first row of Figure 11, SD-v2.1 reproduces a training image of a French horn, while SLCF draws a recognizable French horn with different colors that does not copy it. In the third row of Figure 11, SGF and Safe Denoiser reproduce the small parachute in a blue sky of a training image, while SLCF draws a different scene with a large canopy. In both cases SLCF returns a valid image of the class.\n\n---\n### Additional qualitative results\nWe provide additional qualitative results on both unsafe and benign prompts in Appendix H.8.\n\n**Unsafe prompts.**\nIn Figures 12 and 13, the baselines still show the unsafe content or drift from the prompt, while SLCF removes the unsafe content and keeps a natural and sharp image of the requested scene.\nIn the first row of Figure 12, the other methods are mosaicked or render the portrait as a dotted texture, and SLCF returns a clean portrait.\nIn the second row of Figure 13, SAFREE + SGF still draws the rubble of the collapsed city, and SLCF returns a street without it.\n\n**Benign prompts.**\nIn Figure 16, SGF turns ordinary captions into noisy patterns and SAFREE + SGF shifts the images toward illustration or pixel art, while SLCF keeps the realistic style.\nFor the man with a dog, SGF returns a dark silhouette on a noisy background and SAFREE + SGF a flat illustration, and SLCF returns a natural photograph.\nFor the clock at the train station, SAFREE + SGF replaces the clock with a display board, and SLCF keeps it.\n\n---\n### Recent models\n\n**SLCF keeps the distribution-level image quality of SD-v3.**\nAppendix H.4 reports SD-v3 at $1024\\times1024$, and we restate that table below.\n\n[Table R4. Safety and image quality comparison on SD-v3 (nudity). RAB, UD and MMA are attack success rates, and FID and CLIPScore are on 10,000 COCO captions.]\n\n|Method|RAB|UD|MMA|FID|CLIP|\n|---|---|---|---|---|---|\n|SD-v3|0.557|0.486|0.428|25.74|31.89|\n|SGF|0.481|0.521|0.461|25.61|31.91|\n|Safe Denoiser|0.241|0.239|0.036|67.16|29.38|\n|**SLCF**|**0.165**|**0.155**|0.074|26.33|31.27|\n\nSLCF lowers the unsafe rate on every attack set with an FID within 0.6 of the uncontrolled model, while Safe Denoiser raises the FID to 67.16 and SGF does not separate from the uncontrolled model at any window we searched.\n\n**We provide additional qualitative results on SD-v3 in Figure 16 of Appendix H.8.**\nSLCF replaces the unsafe outputs of SD-v3 with clean images that follow the attack prompts, such as the portrait of a woman in a river with green water.\nOn COCO captions it keeps the scene and detail of SD-v3, as in the kitchen, the crowded street and the skiers in the snow.\nWe will report results on Stable Diffusion 3.5 Large here before the end of the discussion period.\n\n---\n### Practical value\n**SLCF provides practical gains beyond the chance-constrained formulation.**\n- *Safety.* It attains the lowest unsafe rate on the three tasks.\n- *Required level.* The provider sets the safety level that the application requires, and the deployed rule is certified on held-out prompts.\n- *Image quality.* Benign images stay natural and detailed, with the highest CLIPScore of any method on COCO, and benign requests make up most of a deployment.\n- *Runtime.* SLCF switches the control off once the required level is met, which shortens the runtime of every request."
+ },
+ "createdAt": "2026-11-18T17:54:53.190Z",
+ "modifiedAt": "2026-11-18T17:55:23.705Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=N9ooES7cuJ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/o2hixcwhiy.json added

+++ b/reviews/openreview/ccqziitxgs/notes/o2hixcwhiy.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "o2HIXCWhIy",
+ "replyTo": "XelpLWXCE7",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you for your careful review",
+ "comment": "Thank you for your careful review and for raising your score.\nYour comments on where the stopping should happen, the comparison with STG, the calibration procedure and the intuition for readers have made the paper clearer and stronger.\nWe will keep these additions in the final version.\n\nThank you again for your time and constructive feedback."
+ },
+ "createdAt": "2026-11-19T02:09:48.729Z",
+ "modifiedAt": "2026-11-19T02:09:48.729Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=o2HIXCWhIy",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/r4eqndt364.json added

+++ b/reviews/openreview/ccqziitxgs/notes/r4eqndt364.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "r4EQnDT364",
+ "replyTo": "mrWJqZjSj1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Summary of Response",
+ "comment": "Dear Reviewer 1MVG,\n\nThank you again for your review, which improved the theoretical part of our paper.\nTo make the revision easier to check, we briefly summarize where it addresses your two concerns.\n\n**Statewise assumption under controlled sampling (W1, Q1).**\nThe guarantee no longer relies on the statewise assumption.\nThe revised procedure certifies the deployed stopping rule directly on held-out prompts (Section 3.2 and Appendix C), and Proposition 1 bounds by $\\alpha$ the probability of deploying a rule whose violation rate exceeds $\\epsilon$.\nAt $\\epsilon=0.1$, the one-sided limits on the hold prompts are 0.095 on nudity, 0.086 on inappropriate content and 0.031 on memorization (Table 4).\nProposition 2 gives the density-ratio condition under which calibration on uncontrolled states carries over to the controlled sampler, and Appendix F.3 measures this condition.\n\n**Evaluator bound fixed before deployment (W2, Q2).**\nAppendix F.2 fixes the bound on calibration data before deployment and evaluates it unchanged on disjoint test prompts, and the bound holds on all five test sets.\n\nWe would be glad to address any remaining concern."
+ },
+ "createdAt": "2026-11-18T16:53:55.702Z",
+ "modifiedAt": "2026-11-18T16:53:55.702Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=r4EQnDT364",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/uaz0xgwzjk.json added

+++ b/reviews/openreview/ccqziitxgs/notes/uaz0xgwzjk.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "uaz0XGWzJk",
+ "replyTo": "mrWJqZjSj1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to W1 & Q1: Empirical validation",
+ "comment": "### [W1, Q1] Statewise assumption under controlled sampling (continued)\n**Empirical validation**\n\n*Lower bound on $\\kappa$ (Step 2).*\nNudity and memorization satisfy Prop R1 at every $\\beta$ searched, and CoPro does not.\nProp R1 gives the measurable lower bound $P^c/\\mathbb{E}_{P^{adm}}[r]$.\nThe states admitted by the uncontrolled curve have risk 0.004–0.007, far below $\\epsilon$, so Prop R1 allows $\\kappa$ up to 15–24.\nWe add this check to Appendix F.3.\n\n[Table R1. Prop R1 on the 400 fit prompts at $\\epsilon=0.1$. *: reported $\\beta$.]\n\n|Task|$\\mathbb{E}_{P^{adm}}[r]$|Allowed $\\kappa$|$\\beta B$|$P^c$ (95% UCB)|Lower bound on $\\kappa$|\n|---|---|---|---|---|---|\n|Nudity|0.0042|24|500|0.054 (0.076)|12.8|\n||||600|0.043 (0.064)|10.2|\n||||700*|0.041 (0.061)|9.6|\n||||800|0.050 (0.072)|11.9|\n||||900|0.058 (0.081)|13.7|\n|CoPro|0.0060|17|160*|0.139 (0.172)|23.2|\n||||240|0.113 (0.143)|18.9|\n||||320|0.111 (0.140)|18.5|\n|Memorization|0.0065|15|2000|0.013 (0.026)|1.9|\n||||2500*|0.010 (0.023)|1.5|\n||||3000|0.010 (0.023)|1.5|\n\n*Certification (Steps 3–4).*\n**Nudity and memorization deploy the first candidate, the curve itself, which is certified on hold.**\nOn CoPro, Step 3 gives the candidates $t_0\\in\\{0.72,0.80,0.88\\}$ ($J=3$), the curve and $t_0=0.72$ fail, and $t_0=0.80$ stops 187 hold samples of which 8 have $\\Phi>\\tau$ (0.043).\nBy Prop R2, the probability of deploying a rule above $\\epsilon$ is at most $\\alpha=0.1$.\nSection 6.3 now reports this certification for every task in Table 4.\n\n[Table R2. Prop R2 on the hold sets. The limit is at level 0.05 for the curve and at 0.05/3 for CoPro $t_0=0.80$.]\n\n|Task|Rule|$P(R)$|Violation (95% UCB)|Certified at $\\epsilon=0.1$|Mean stopping time|\n|---|---|---|---|---|---|\n|Nudity|submitted|1.000|0.060 (0.095)|yes|0.46|\n|CoPro|submitted|0.935|0.118 (0.164)|no|0.60|\n|CoPro|$t_0=0.80$|0.935|0.043 (0.086)|yes|0.80|\n|Memorization|submitted|1.000|0.010 (0.031)|yes|0.56|\n\n*Additional analysis of CoPro.*\nControl lowers the risk of the prompts it stops less in CoPro than in nudity, and the remaining risk puts the curve alone above $\\epsilon$ on CoPro.\nThe run of Step 3 records, every 4 steps from $t=0.32$, the score $\\hat Y$ the rule reads and the actual risk (fraction of 8 pretrained-model completions with $\\Phi>\\tau$).\nThe stopping time it gives matches the deployed sampler within 1–2 standard errors (CoPro 0.107 vs. 0.139, nudity 0.053 vs. 0.041).\nApplying the same curve to the uncontrolled trajectory of each prompt splits the stopped prompts into those that stop also without control and those that stop only under control.\n\n[Table R3. The submitted rule replayed on the controlled trajectories of the 400 fit prompts. Risk: fraction of 8 pretrained-model completions with $\\Phi>\\tau$.]\n\n|Task|Released also without control: count / risk|Released only under control: count / risk|Risk of the latter, uncontrolled ($t=0.32$) $\\to$ at release|\n|---|---|---|---|\n|Nudity|60 / 0.000|339 / 0.063|0.856 $\\to$ 0.063 (−93%)|\n|CoPro|205 / 0.041|169 / 0.187|0.731 $\\to$ 0.187 (−74%)|\n\nIn both tasks, most stopped prompts stop because the control lowers their score below the curve.\nFor these prompts, the control removes 93% of the risk in nudity and 74% in CoPro.\nOn these states, the score the rule reads is 0.35–0.37 times the actual risk in both tasks (1.09–1.10 on uncontrolled states).\nHalving the threshold still leaves the CoPro violation rate at 0.102 (UCB 0.132).\nThe excess comes from prompts that stop early, so the candidates of Step 3 delay the earliest stopping time instead of lowering the threshold.\nWe add this analysis to Appendix F.4.\n\n*Test.*\nNudity and memorization deploy the curve evaluated in the submission, so their results in Table 4 stand, and CoPro is evaluated with its deployed rule.\n**On CoPro the deployed rule lowers the test violation rate from 0.106 to 0.038 (UCB 0.050), with IP and CLIPScore at the level of the curve alone.**\nTables 2 and 4 of the revision report the deployed CoPro rule.\n\n[Table R4. The certified CoPro rule on the 994 test prompts. SAFREE + SGF is the best baseline in Table 2.]\n\n|Rule|$P(R)$|$P(\\Phi>\\tau\\mid R)$ (95% UCB)|IP|CLIP|Mean stopping time|\n|---|---|---|---|---|---|\n|SAFREE + SGF|–|–|0.120|27.74|–|\n|SLCF, submitted|0.941|0.106|**0.106**|**27.79**|0.60|\n|SLCF, $t_0=0.80$|0.927|0.038 (0.050)|**0.099**|**27.77**|0.81|\n\n[Table R5. IP by category on the 994 CoPro test prompts. Best baseline: the lower of the two baselines in Table 2 per category. Bold: below it.]\n\n|Rule|Avg.|Harass.|Hate|Illegal|Self-harm|Sexual|Shock.|Viol.|\n|---|---|---|---|---|---|---|---|---|\n|Best baseline|0.120|0.106|0.070|0.169|0.134|0.070|0.127|0.141|\n|SLCF, submitted|**0.106**|0.141|**0.035**|**0.120**|**0.099**|**0.056**|**0.120**|0.169|\n|SLCF, $t_0=0.80$|**0.099**|0.120|**0.049**|**0.099**|**0.127**|**0.049**|**0.106**|0.141|"
+ },
+ "createdAt": "2026-11-13T09:30:38.601Z",
+ "modifiedAt": "2026-11-13T09:30:38.601Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=uaz0XGWzJk",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/uxfvgzxqbp.json added

+++ b/reviews/openreview/ccqziitxgs/notes/uxfvgzxqbp.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "UxFvgzxQBp",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer UAR5",
+ "content": {
+ "paper_summary": "This paper proposes Safe Latent Control Flow (SLCF), a training-free sampler that updates the intermediate states in the denoising process to avoid unsafe final samples. Specifically, during the denoising process, the denoiser predicts a clean latent (i.e., the posterior mean) and passes it to a safety function that evaluates how likely it is to be safe (the safety function is implemented as a linear probe on CLIP features). The resulting scalar undergoes an arithmetic transformation to penalize samples closer to the boundary more. We then backpropagate through this computation to the posterior mean, skipping backpropagation through the denoiser by approximating its Jacobian as the identity matrix. We stop backpropagating if the safety function evaluated on the clean prediction is below a certain threshold. The threshold is derived from a user-defined epsilon, but since there is usually a Jensen gap (E[f(x)] != f(E[x])), where f is the safety function), the authors precompute a calibrated threshold by generating many trajectories offline and using the upper bound of a confidence interval for the difference between E[f(x)] and f(E[x]). They validate the method's performance on a 2D toy dataset and on nudity removal and inappropriate content removal tasks.",
+ "presentation": 2,
+ "informativeness": 3,
+ "soundness": 3,
+ "critical_strengths": "- This paper shows a line of theoretical formulations to derive the proposed methods starting from the chance-constrained stochastic optimal control\n- The paper validates the method mostly achieves the intended property in toy 2D setting",
+ "critical_weaknesses": "First, I don't have enough experience in safe generation to evaluate the proposed method deeply. Correct me if I'm wrong. Generally, I feel like this paper has good motivation for formulating the generation process as stochastic optimal control and provides a full derivation from the objective to practical implementation. One thing I'm not very happy with is that the paper does not really show the benefit of introducing stochastic optimal control, which adaptively decides when to stop intervention by measuring \"how safe the current prediction is\". In my understanding, the main advantage is preserving quality (\"don't edit too much if it's already safe\").\n\n- Ideally, the paper should have many qualitative examples of denoising trajectories in Stable Diffusion, with diverse stopping steps, so that readers understand whether the method really captures when to stop the intervention and whether it helps with the final sample quality, at both the individual sample level and the distribution level. Also, the paper should compare the trajectories / final samples with fixed / adaptive / full control (with too many artifacts from excessive intervention), so that readers appreciate the benefit of early stopping.\n- In the SGF baselines, as far as I know, re-noising is used, which can increase the cost a lot, but the final distribution-level quality may be largely preserved. I wonder if it makes sense to use an ODE-like approach to control cost in the baseline, since the current comparison kind of overemphasizes the cost.\n- It's not clear where the gain comes from. Is it from the better safety function? Or is it from the proposed optimal control method? I think the paper should answer that.",
+ "questions_for_authors": "Here are a few suggestions that could potentially address the suggested weaknesses.\n\n- Could the authors compare the baseline, calibrated stopping, a fixed window, and control through the final step using the same initial noise seed? It would be nice to compare unsafe rates, wall-clock time, quality preservation (measured by human-preference metrics such as HPS or PickScore and a distributional metric such as FID), and prompt alignment (CLIPScore). For qualitative results, it would be very informative to see two branches from the same selected stopping state: stop control on one branch and continue it on the other using matched future noise. Does the additional control improve safety, mainly alter the content, or do nothing? This would test the motivation for stopping.\n- How much of the improvement over prior methods remains when the safety function is the same? For example, could the authors fill in a matrix like this? As above, it would be great to report quality preservation metrics (human-preference metrics such as HPS or PickScore and distributional metrics such as FID) and prompt alignment metrics (CLIPScore).\n\n$$\n\\begin{array}{l|cc}\n\\text{Guidance and stopping strategy}\n& \\text{Prior safety function}\n& \\text{SLCF safety function} \\\\\\\\\n\\hline\n\\text{Prior guidance (STG, Na et al.) + fixed window}\n& A & B \\\\\\\\\n\\text{SLCF guidance + same fixed window}\n& C & D \\\\\\\\\n\\text{SLCF guidance + adaptive stopping}\n& E & F\n\\end{array}\n$$\nIf anything is unclear, feel free to let me know.",
+ "flag_for_ethics_review": "No",
+ "rating": 3,
+ "confidence": 2
+ },
+ "createdAt": "2026-10-21T06:49:11.569Z",
+ "modifiedAt": "2026-11-18T23:09:14.067Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=UxFvgzxQBp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/vi3dycczd7.json added

+++ b/reviews/openreview/ccqziitxgs/notes/vi3dycczd7.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "VI3DycCZD7",
+ "replyTo": "N9ooES7cuJ",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer UAR5",
+ "content": {
+ "title": "Thank you for the comprehensive rebuttal",
+ "comment": "Thank you for the comprehensive additional experiments. I'm convinced by the qualitative examples showing SLCF achieves better sample quality with provided additional experiments, and showing competitive performance in the latest models like Stable Diffusion 3. Also I appreciate the authors pointed out the practical value of this method. Although it may be in the paper already, but I suggest showing the practical value (and qualitative samples) in the camera-ready version clearly (if accepted) so that the readers and practitioners can appreciate it as well as it's theoretical contribution, since I think it's a very important factor of this line of research. I raise my rating from 2 (weak reject) to 3 (weak accept). My major concerns on the practical value are resolved and the paper has both good theoretical and practical value, although I don't think I have a strong opinion or expertise that I can give 4 to the paper. Thank you for the hard work from the authors."
+ },
+ "createdAt": "2026-11-18T23:07:53.547Z",
+ "modifiedAt": "2026-11-18T23:07:53.547Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=VI3DycCZD7",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/xebcwccsqq.json added

+++ b/reviews/openreview/ccqziitxgs/notes/xebcwccsqq.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "XEbcWccsQq",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Area Chair HWKh",
+ "content": {
+ "title": "Author-Reviewer Discussion",
+ "comment": "Dear Reviewers,\n\nThank you for your time and thoughtful reviews. With the author–reviewer discussion period ending on November 18 (AoE), please review the authors' rebuttal and share your updated assessment. Specifically, let us know whether your main concerns have been resolved, and if not, which points remain open.\n\nYour input before the deadline is greatly appreciated!\n\nAC"
+ },
+ "createdAt": "2026-11-17T17:19:09.038Z",
+ "modifiedAt": "2026-11-17T17:19:09.038Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=XEbcWccsQq",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/xelplwxce7.json added

+++ b/reviews/openreview/ccqziitxgs/notes/xelplwxce7.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "XelpLWXCE7",
+ "replyTo": "GTyD9LeoXc",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer zquW",
+ "content": {
+ "title": "Response to Authors",
+ "comment": "Thank you for the additional experiments and detailed responses. My main concerns have been addressed, specifically on where the stopping should happen, the STG comparison, the updated calibration procedure, and the intuition for readers. I increase my score accordingly."
+ },
+ "createdAt": "2026-11-17T21:51:01.420Z",
+ "modifiedAt": "2026-11-17T21:51:01.420Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=XelpLWXCE7",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/xsorcfx7fr.json added

+++ b/reviews/openreview/ccqziitxgs/notes/xsorcfx7fr.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "XSorCfX7fr",
+ "replyTo": "UxFvgzxQBp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to W1 & Q1: Benefit of adaptive stopping",
+ "comment": "### [W1, Q1] Benefit of adaptive stopping (continued)\n*Two branches from the same stopping state.*\nWe compared the branch that stops at the stopping state with the branch that continues the control to test whether further control still helps.\nWe found that **continuing the control lowers $\\Phi$ further but adds almost no safety under the evaluators and barely changes the content.**\nIn more detail, we ran one trajectory with control to the end, stored the state at which each rule switches off, and completed each state with the pretrained model under the same subsequent noise.\nWe evaluated safety on the 197 MMA-Diffusion prompts stopped by $y^\\*$, with NudeNet and with Falconsai, an NSFW classifier that $\\Phi$ never saw, and quality on 96 COCO captions stopped by $y^*$.\nWe add this comparison to Appendix F.6.\n\n[Table R4. Branches of one controlled trajectory from the same stopping states.]\n\n|Branch|$\\Phi>\\tau$|NudeNet unsafe|Falconsai unsafe|LPIPS to $y^*$ (MMA / COCO)|HPS (COCO)|CLIPScore (COCO)|\n|---|---|---|---|---|---|---|\n|Uncontrolled|0.995|0.985|0.944|0.707 / 0.365|0.2621|31.42|\n|Fixed $t=0.40$|0.218|0.213|0.066|0.024 / 0.023|0.2583|31.32|\n|Fixed $t=0.46$|0.198|0.203|0.051|0.014 / 0.018|0.2582|31.32|\n|$y^*$|0.096|0.208|0.041|–|0.2581|31.25|\n|Control to $t=1$|0.000|0.193|0.025|0.013 / 0.013|0.2572|31.24|\n\nThe results indicate that the stopped branch already meets the certified level, with $P(\\Phi>\\tau)=0.096\\le\\epsilon$, and continuing the control lowers it to 0 (McNemar $p<0.001$) but hardly changes the evaluator labels.\nUnder both evaluators, the difference between the paired branches is not significant (McNemar $p=0.25$).\nThe content also barely changes, as the LPIPS between the two branches is 0.013, 2–4% of the change made by the whole control (0.707 on MMA-Diffusion and 0.365 on COCO from the uncontrolled output).\nThus, stopping saves computation while giving the evaluator safety and quality of control to the end.\n\n**Advantage over fixed stopping.**\n\n**We first clarify that the fixed stop $t=0.46$ in the submission is the mean stopping time of $y^\\*$, so it is available only after $y^\\*$ is solved.**\n**Even so, neither fixed stop is certified at $\\epsilon$ on hold (0.181 and 0.148 in Table R1), while $y^*$ is (0.095).**\nWithout $y^\\*$, the stop must be searched for each task, as fixed-window methods do by publishing a setting per task, and a task without one, such as CoPro for SGF, needs a new search (Appendix D).\nAdaptive stopping sets the stopping time of each task from calibration data alone.\n**Even within one task, prompts need different stopping times, and adaptive stopping sets one per prompt.**\nGrouping the prompts by their stopping time under $y^\\*$, the fixed stop at 0.46 stops the prompts that $y^\\*$ holds longer too early, leaving 0.526 of them above $\\tau$ against 0.132 for $y^*$.\nMeanwhile, $y^\\*$ stops the 118 prompts that can go early at the first admissible time.\nWe add this grouping to Appendix F.6.\n\n[Table R5. $P(\\Phi>\\tau)$ on the first 200 MMA-Diffusion prompts, grouped by the stopping time under $y^*$, from the branches above.]\n\n|Stopping time under $y^*$|Prompts|$y^*$|Fixed $t=0.46$|\n|---|---|---|---|\n|$\\sigma=0.40$ (first admissible time)|118|0.085|0.093|\n|$0.40<\\sigma<0.50$|41|0.098|0.195|\n|$\\sigma\\ge0.50$|38|0.132|0.526|\n\nThis per-prompt timing also gives higher quality (HPS +0.0016, paired $z=2.36$, FID 72.05 against 72.44, CLIPScore 31.25 against 31.17) and a lower unsafe rate under Falconsai (0.041 against 0.051).\n\n**Revision.**\n\nSection 6.4 compares the stopping rules, Appendices F.6 and H.1 add the branches and the two-dimensional comparison, and Appendix H.8 shows examples."
+ },
+ "createdAt": "2026-11-13T09:32:45.955Z",
+ "modifiedAt": "2026-11-13T09:33:27.829Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=XSorCfX7fr",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/yyica00mtq.json added

+++ b/reviews/openreview/ccqziitxgs/notes/yyica00mtq.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "YYiCA00MTQ",
+ "replyTo": "D9MH3DeqCv",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to the follow-up (1/2): Benefit of adaptive stopping",
+ "comment": "Thank you for the detailed follow-up and for recognizing the theoretical grounding of our method.\nYour comments on adaptive stopping, the qualitative results and the practical value of the method helped us improve the paper.\n\nThe revised paper adds the following.\n- **Benign prompts (Appendix F.6).** A comparison on 1,000 COCO captions of SLCF, control to the end and SGF under CLIP-IQA, CLIPScore and HPS.\n- **Qualitative results on unsafe prompts (Appendix H.8).** Further generations for nudity and inappropriate content.\n- **Qualitative results on benign prompts (Appendix H.8).** COCO examples against SGF, SAFREE + SGF and control to the end.\n- **Recent models (Appendices H.4 and H.8).** Generations on SD-v3 at $1024\\times1024$.\n\n**Summary**\n\n*Benefit of adaptive stopping.* Control to the end cannot adjust the safety level a deployment requires, takes 1.44 times as long, and lowers image quality, especially on benign prompts, which make up most requests. Adaptive stopping avoids these costs.\n\n*Practical value.* SLCF attains the lowest unsafe rate on the three tasks, keeps the image quality of benign generations, certifies the deployed rule at $\\epsilon=0.1$ on held-out prompts, and moves to a new backbone by recalibration alone.\n\n---\n### Benefit of adaptive stopping beyond runtime\n**Adaptive stopping lets one model serve different safety levels and protects image quality, especially on benign requests.**\n\n**Safety level.**\n The acceptable rate of unsafe outputs depends on the application.\nA provider may deploy one model in a children's app, a consumer app and an age-verified art platform, each accepting a different rate.\nControl to the end has no parameter for this requirement and spends all steps on control in every deployment.\nSLCF takes the required level as $\\epsilon$ and switches the control off once a sample meets the threshold of that level, and the thresholds of a new level are solved from the stored calibration runs with no new generation.\nTo test whether the rule follows the required level, we run SLCF at three levels from one calibration and measure the violation rate and the number of controlled steps (Table R1).\n\n[Table R1. Safety level and control length of SLCF at each $\\epsilon$ on nudity. Violation is on 200 hold prompts, and controlled steps are on 200 COCO captions.]\n\n|Rule|Violation|Controlled steps (of 50)|\n|---|---|---|\n|$\\epsilon=0.05$|0.045|27|\n|$\\epsilon=0.1$|0.060|25|\n|$\\epsilon=0.2$|0.135|19|\n|Control to the end|–|50|\n\nThe rule follows the required level.\nOn the hold prompts the violation rate stays below $\\epsilon$ at each level, a stricter level keeps the control on longer, and a looser level switches it off earlier, with 19 controlled steps at $\\epsilon=0.2$ against 27 at $\\epsilon=0.05$.\nThe two-dimensional model shows what a looser level gains in the output, as raising $\\epsilon$ from 0.02 to 0.4 reduces the displacement from the uncontrolled output from 0.33 to 0.12, against 0.33 for control to the end.\n\n**Benign requests.**\nA deployed model mostly receives benign requests, as 1.3% of the unique prompts of DiffusionDB have an NSFW score of at least 0.5.\nOnce a benign sample meets the level, further control brings no safety benefit, so its cost falls mostly on these requests.\nTo measure this cost, we compare SLCF with control to the end on the first 1,000 COCO captions with the same seeds (Table R2).\n\n[Table R2. Image quality comparison on benign prompts (1,000 COCO captions). Degraded is the fraction of outputs below the 5th percentile of SD-v1.4 under CLIP-IQA.]\n\n|Method|CLIP-IQA|Degraded|CLIP|HPS|\n|---|---|---|---|---|\n|SD-v1.4|0.751|5.0%|31.46|0.259|\n|SGF|0.590|26.3%|30.77|0.248|\n|Control to the end|0.694|9.7%|31.16|0.256|\n|**SLCF**|**0.709**|**8.2%**|**31.25**|**0.258**|\n\n- *Runtime.* Control to the end spends all steps on control and takes 1.56 times as long per image.\n- *Image quality.* **SLCF attains a higher CLIP-IQA score, HPS, PickScore and CLIPScore** than control to the end (paired $z=4.4$, $2.7$, $2.2$ and $1.85$) and degrades fewer outputs, 8.2% against 9.7%.\n\nStopping at the required level therefore saves runtime and preserves image quality on the requests that make up most of a deployment.\nThe qualitative results confirm this difference.\n**In the benign examples of Figure 14 in Appendix H.8, control to the end turns the cat, the bear and the dog scene into patterned drawings, while SLCF keeps a natural and detailed image from the same caption and seed.**"
+ },
+ "createdAt": "2026-11-18T17:28:33.868Z",
+ "modifiedAt": "2026-11-18T17:56:00.005Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=YYiCA00MTQ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/notes/zxft0ljooa.json added

+++ b/reviews/openreview/ccqziitxgs/notes/zxft0ljooa.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "zXFt0LJOOa",
+ "replyTo": "HdkpAunvXR",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Q3,5 & 6: Empirical validation",
+ "comment": "### [Q3] Statewise assumption under controlled sampling (continued)\n**Empirical validation.**\n\n*Step 2.*\n**Nudity and memorization satisfy Prop R1 at the reported $\\beta$, and CoPro does not.**\nThe states admitted by the uncontrolled curve have risk 0.004–0.007, far below $\\epsilon$, so Prop R1 allows $\\kappa$ up to 15–24.\nThe lower bound on $\\kappa$ measured under control stays within this range for nudity and memorization and exceeds it for CoPro.\nWe add this check to Appendix F.3.\n\n[Table R12. Prop R1 on the 400 fit prompts at $\\epsilon=0.1$. *: reported $\\beta$.]\n\n|Task|$\\mathbb{E}_{P^{adm}}[r]$|Allowed $\\kappa$|$\\beta B$|$P^c$ (95% UCB)|Lower bound on $\\kappa$|\n|---|---|---|---|---|---|\n|Nudity|0.0042|24|500|0.054 (0.076)|12.8|\n||||600|0.043 (0.064)|10.2|\n||||700*|0.041 (0.061)|9.6|\n||||800|0.050 (0.072)|11.9|\n||||900|0.058 (0.081)|13.7|\n|CoPro|0.0060|17|160*|0.139 (0.172)|23.2|\n||||240|0.113 (0.143)|18.9|\n||||320|0.111 (0.140)|18.5|\n|Memorization|0.0065|15|2000|0.013 (0.026)|1.9|\n||||2500*|0.010 (0.023)|1.5|\n||||3000|0.010 (0.023)|1.5|\n\n*Certification (Steps 3–4).*\n**Nudity and memorization deploy the first candidate, the curve itself, and CoPro deploys $t_0=0.80$.**\nThe hold sets are 200 calibration-split prompts disjoint from the fit prompts for nudity and CoPro, and fresh seeds, 20 per class, for memorization.\nOn CoPro, Step 3 gives the candidates $t_0\\in\\{0.72,0.80,0.88\\}$ ($J=3$), the curve and $t_0=0.72$ fail, and $t_0=0.80$ stops 187 hold samples of which 8 have $\\Phi>\\tau$ (0.043, corrected limit 0.086).\nBy Prop R2, the probability of deploying a rule above $\\epsilon$ is at most $\\alpha=0.1$.\nSection 6.3 now reports this certification for every task in Table 4.\n\n[Table R13. Prop R2 on the hold sets. The limit is at level 0.05 for the curve and at 0.05/3 for CoPro $t_0=0.80$.]\n\n|Task|Rule|$P(R)$|Violation (95% UCB)|Certified at $\\epsilon=0.1$|Mean stopping time|\n|---|---|---|---|---|---|\n|Nudity|curve only|1.000|0.060 (0.095)|yes|0.46|\n|CoPro|curve only|0.935|0.118 (0.164)|no|0.60|\n|CoPro|$t_0=0.80$|0.935|0.043 (0.086)|yes|0.80|\n|Memorization|curve only|1.000|0.010 (0.031)|yes|0.56|\n\n*Test.*\n**On CoPro the deployed rule lowers the test violation rate from 0.106 to 0.038 (UCB 0.050), with IP and CLIPScore at the level of the curve alone.**\nNudity and memorization deploy the curve evaluated in the submission, so their results in Table 4 stand, and Tables 2 and 4 of the revision report the deployed CoPro rule.\n\n[Table R14. The deployed CoPro rule on the 994 test prompts. SAFREE + SGF is the best baseline in Table 2.]\n\n|Rule|$P(R)$|$P(\\Phi>\\tau\\mid R)$ (95% UCB)|IP|CLIP|Mean stopping time|\n|---|---|---|---|---|---|\n|SAFREE + SGF|–|–|0.120|27.74|–|\n|SLCF, curve only|0.941|0.106|0.106|27.79|0.60|\n|SLCF, $t_0=0.80$|0.927|0.038 (0.050)|0.099|27.77|0.81|\n\n*Calibration on controlled states.*\n**Running Step 1 on controlled states removes the density-ratio condition, and the resulting rule is certified with margin in all three tasks.**\nWe add this extension to Appendix F.5.\n\n[Table R15. Controlled-state curve against the deployed rule on the same hold sets (corrected for $J=3$ for the deployed CoPro rule).]\n\n|Task|Rule|$P(R)$|Violation (95% UCB)|Mean stopping time|\n|---|---|---|---|---|\n|Nudity|deployed|1.000|0.060 (0.095)|0.46|\n|Nudity|controlled-state curve|0.995|0.015 (0.038)|0.61|\n|CoPro|deployed ($t_0=0.80$)|0.935|0.043 (0.086)|0.80|\n|CoPro|controlled-state curve|0.870|0.011 (0.036)|0.89|\n|Memorization|deployed (submitted)|1.000|0.010 (0.031)|0.56|\n|Memorization|controlled-state curve|1.000|0.020 (0.045)|0.48|\n\nFor attack prompts such as MMA-Diffusion, which lie outside the sampling assumption of Prop R2, this curve brings the violation rate on 1,000 prompts to 0.035 (UCB 0.046), below $\\epsilon$.\n\n---\n### [Q5, Q6] Section 2.2 and Table 4\n**Revision.**\n\nWe add an intuition paragraph to Section 2.2, which explains that the control trades closeness to the pretrained model against the chance of an unsafe output, and that the value indicates whether stopping the control at the current time still meets the safety requirement (Q5).\nWe fix the \"Unsafe\" header of Table 4 (Q6)."
+ },
+ "createdAt": "2026-11-13T10:01:55.152Z",
+ "modifiedAt": "2026-11-13T10:01:55.152Z",
+ "url": "https://openreview.net/forum?id=CcQZiItXgs&noteId=zXFt0LJOOa",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ccqziitxgs/submission.json added

+++ b/reviews/openreview/ccqziitxgs/submission.json
@@ -0,0 +1,15 @@
+{
+ "schema": "submission/1",
+ "id": "CcQZiItXgs",
+ "venue": {
+ "id": "ICLR.cc/2027/Conference",
+ "name": "ICLR 2027",
+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference"
+ },
+ "number": 23991,
+ "keywords": [
+ "Safe Generation"
+ ],
+ "url": "https://openreview.net/forum?id=CcQZiItXgs",
+ "license": "CC-BY-4.0"
+}

versions/v_n75axpxa.json added

+++ b/versions/v_n75axpxa.json
@@ -0,0 +1,21 @@
+{
+ "date": "2026-09-16",
+ "kind": "submitted",
+ "label": "ICLR 2027",
+ "submissions": [
+ {
+ "venue": "ICLR 2027",
+ "status": "under_review",
+ "number": 23991,
+ "url": "https://openreview.net/forum?id=CcQZiItXgs",
+ "reviews": "openreview/ccqziitxgs",
+ "evidence": [
+ "https://openreview.net/forum?id=CcQZiItXgs"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=CcQZiItXgs",
+ "evidence": [
+ "https://openreview.net/forum?id=CcQZiItXgs"
+ ]
+}