Clinical Trajectory Alignment for Medical Vision-Language Pre-training
Import ICLR 2027 submission QLgyGAhN3P: 23 notes
@openreview[bot] · 2026-11-22 21:11 UTC · b63bfd17ea77
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,19 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "QLgyGAhN3P"+ }+ ],+ "title": "Clinical Trajectory Alignment for Medical Vision-Language Pre-training",+ "authors": [],+ "abstract": "Medical vision-language pre-training largely follows a visit-level image-report matching paradigm, aligning paired images and reports at individual visits. While effective for static cross-modal correspondence, this paradigm provides limited supervision for longitudinal clinical change, such as whether abnormalities improve, remain stable, or worsen over time. Learning such change is challenging because temporal semantics are implicit in free-text reports, and different abnormalities within the same patient may evolve asynchronously or even in opposite directions. We propose MedCTA, which reframes medical vision-language pre-training from visit-level cross-modal matching to learning clinical change. Rather than compressing a patient history into a single temporal representation, MedCTA models clinical change at two complementary scopes. At the abnormality scope, clinically grounded queries construct abnormality-conditioned visual and textual trajectories to capture heterogeneous abnormality evolution. At the patient-course scope, global image and report sequences are modeled to capture overall clinical progression beyond any individual abnormality. Structured trend supervision is extracted from longitudinal reports by an offline LLM parser, removing the need for manual temporal annotations. Combined with static image-report alignment, MedCTA learns representations that preserve visit-level cross-modal correspondence while encoding longitudinal change semantics. Experiments on temporal image classification, image-text retrieval, and zero-shot classification show consistent gains over strong medical vision-language baselines.",+ "year": 2027,+ "venue": "ICLR 2027 (under review)",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://potentialpaper.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/qlgygahn3p/forms.json added
+++ b/reviews/openreview/qlgygahn3p/forms.json@@ -0,0 +1,183 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "additional_comments_on_reviewer_discussion",+ "label": "Reviewer discussion",+ "type": "text"+ },+ {+ "key": "recommendation",+ "label": "Recommendation",+ "type": "choice"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "soundness",+ "presentation",+ "informativeness"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "soundness",+ "label": "Soundness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "presentation",+ "label": "Presentation",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "informativeness",+ "label": "Informativeness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "paper_summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "critical_strengths",+ "label": "Strengths",+ "type": "text"+ },+ {+ "key": "critical_weaknesses",+ "label": "Weaknesses",+ "type": "text"+ },+ {+ "key": "questions_for_authors",+ "label": "Questions for the authors",+ "type": "text"+ },+ {+ "key": "flag_for_ethics_review",+ "label": "Flag for ethics review",+ "type": "choice",+ "omitWhen": [+ "No",+ "No ethics review needed."+ ]+ },+ {+ "key": "details_of_ethics_concerns",+ "label": "Ethics concerns",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/1xia91yz3i.json added
+++ b/reviews/openreview/qlgygahn3p/notes/1xia91yz3i.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "1xia91yZ3I",+ "replyTo": "5ghZU73lN1",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Response to W2, Q3, Q4, Q5:\n**(1) Details of Downstream Tasks**\n\n- Temporal Image Classification: The pre-trained image encoder is frozen, and only the classification head is trained on Chest ImaGenome. The current and previous chest X-rays are processed by the shared encoder to generate image-level features, which are concatenated in the order of \"current, previous\" to predict the corresponding abnormality trend, including improvement, stability, or worsening. During MS-CXR-T testing, both the image encoder and classification head are frozen. This task uses image-level features.\n- Temporal Sentence Similarity Classification: Two text sentences are separately encoded by the frozen text encoder to extract global features. After L2 normalization, cosine similarity is calculated, and ACC and AUROC are used for evaluation.\n- Phrase Grounding: The image and text encoders are frozen. Similarities between image patch features and text features are used to generate heatmaps, and IoU, Dice, and CNR are reported in conjunction with manually annotated bounding boxes. As shown in Table 4, MedCTA achieves higher values than TAMM on all three metrics, with the main improvement observed in CNR.\n\nTable 4. Quantitative phrase-grounding results.\n| Method | IoU | Dice | CNR |\n| --- | ---: | ---: | ---: |\n| TAMM | 0.1108 | 0.1894 | 0.4043 |\n| MedCTA | 0.1124 | 0.1917 | 0.5895 |\n- Image Classification: In the original RSNA/COVIDx experiments, the data were split into training, validation, and test sets at a ratio of 80%/10%/10%. The image encoder was frozen, and the linear classifier was fine-tuned. Therefore, this task is Linear Probe. In the newly added zero-shot experiments, both the image and text encoders are frozen, and classification is performed based on the similarity between images and class texts, without training a classifier using target labels. As shown in Table 5, MedCTA outperforms TAMM and ALTA on ACC, F1, and AUROC across both datasets.\n\nTable 5. Zero-shot image–text classification on COVIDx and RSNA Pneumonia (%).\n| Method | ACC (COVID) | F1 (COVID) | AUROC (COVID) | ACC (RSNA) | F1 (RSNA) | AUROC (RSNA) |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| ALTA | 62.70 | 49.03 | 85.95 | 65.40 | 56.69 | 82.13 |\n| TAMM | 76.12 | 59.19 | 86.15 | 66.85 | 56.19 | 81.62 |\n| MedCTA | 78.02 | 63.93 | 89.62 | 68.22 | 57.91 | 88.60 |\n\n**(2) Experimental Data Splits**\n\nWhen constructing the MedCTA temporal pre-training dataset, we excluded downstream patients based on patient IDs (`subject_id`). MS-CXR-T, MIMIC-5×200, and the Chest ImaGenome subset used in our experiments involve 800, 957, and 16,001 patients, respectively. We took the union of the patient sets from these three datasets and excluded all images and reports belonging to these patients from MIMIC-CXR before constructing longitudinal sequences. The resulting pre-training dataset contains 46,564 patients and 61,164 sequences. We have added details of the data split to Appendix A.1 of the revised manuscript.\n\n**(3) Baseline Details**\n\nWe categorize the baseline results according to their sources:\n- Quoted results: ACC for temporal image classification, ACC for temporal sentence similarity classification, cross-modal retrieval metrics, and ACC and F1 for RSNA/COVIDx linear probing are quoted from the TAMM paper.\n- Reproduced results: AUROC for temporal sentence similarity classification and RSNA/COVIDx classification. Specifically, TAMM was retrained following its original method on the same patient-excluded data as MedCTA, while the remaining baselines were evaluated using their official pre-trained weights.\n\nMedCTA follows the initialization strategy of TAMM, using publicly available MGCA weights for initialization, followed by temporal pre-training on the patient-excluded dataset. The initialization of the remaining baselines follows the experimental configurations reported in the TAMM paper. The parameter counts of all models are reported in Table 6. We have added the baseline details to Appendix A.3 of the revised manuscript.\n\nTable 6. Model parameter counts (M)\n\n| Method | Parameters (M) |\n| --- | ---: |\n| MGCA | 172.73 |\n| MedCLIP | 133.26 |\n| PRIOR | 159.92 |\n| MAVL | 170.65 |\n| CARZero | 220.77 |\n| Med-ST | 233.76 |\n| ALTA | 265.65 |\n| TAMM | 321.91 |\n| MedCTA | 198.70 |"+ },+ "createdAt": "2026-11-14T10:28:00.409Z",+ "modifiedAt": "2026-11-14T10:28:00.409Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=1xia91yZ3I",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/2cmqkcwonj.json added
+++ b/reviews/openreview/qlgygahn3p/notes/2cmqkcwonj.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "2CMQkCWonJ",+ "replyTo": "j6gejchAZq",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for carefully reviewing our additional experiments and acknowledging these experiments and our responses to the previous concerns. We also fully understand your concerns regarding the relatively small size of the trend-disagreement subset and the limited performance gains. We agree that 60 image pairs alone are insufficient to determine whether the observed results can be supported by a larger sample. **To address this concern more thoroughly, we further constructed a larger-scale multi-disease trend-disagreement subset on Chest ImaGenome and evaluated the transferability of the learned representations for disease trend recognition using two evaluation protocols: linear probing and zero-shot evaluation.**\n\n**Data Construction and Splitting.** We constructed a Chest ImaGenome multi-disease trend-disagreement subset containing 6,076 previous–current image pairs from 3,100 patients, verifying examination chronology and trend-label validity. Patients were split into training, validation, and test sets at 70%/15%/15% using random seed 42, yielding 4,254/920/902 image pairs without patient overlap.\n\n**Linear Probe Evaluation Protocol.** For each pre-trained model, we froze the image encoder and global projection layer. Current and previous image features were projected into a shared 128-dimensional space, separately L2-normalized, and concatenated as [current, previous] into a 256-dimensional representation. Only five independent three-class linear heads, one per abnormality, were trained to predict improvement, stability, or worsening. All parameters were frozen during testing, and per-abnormality ACC assessed the representations’ linear separability and transferability to trend recognition.\n\n**Zero-shot Evaluation Protocol.** Image and text encoders and their projection layers remained frozen, without training classification heads. For each abnormality, we predefined severity descriptions representing “no abnormality,” “mild or limited abnormality,” and “severe or extensive abnormality,” encoded as 0, 1, and 2. Each previous and current image was assigned the severity level with the highest image–text cosine similarity. A lower, equal, or higher current level relative to the previous level indicated improvement, stability, or worsening, respectively. Predictions were compared with ground-truth trend labels to calculate ACC for each of the five abnormalities.\n\nTable 1. Disease Trend Classification Results on the Chest ImaGenome Subset Using Linear Probing (ACC, %).\n\n| Method | Consolidation | Edema | Pleural Effusion | Pneumonia | Pneumothorax |\n|---|---:|---:|---:|---:|---:|\n| TAMM | 55.40 | 55.81 | 62.73 | 59.36 | 52.68 |\n| MedCTA | **58.54** | **60.63** | **63.90** | **61.69** | **55.67** |\n\nTable 2. Zero-shot Disease Trend Classification Results on the Chest ImaGenome Subset (ACC, %).\n\n| Method | Consolidation | Edema | Pleural Effusion | Pneumonia | Pneumothorax |\n|---|---:|---:|---:|---:|---:|\n| TAMM | 51.57 | 49.43 | 48.98 | 45.42 | 37.19 |\n| MedCTA | **53.31** | **52.16** | **54.79** | **46.98** | **42.04** |\n\nUnder both evaluation protocols, MedCTA achieves higher classification accuracy than TAMM across all five abnormalities, further supporting the findings observed on the previously constructed smaller subset. For linear probing, the improvements range from 1.17 to 4.82 percentage points across the five abnormalities. The largest gain is observed for edema. Under the setting where the encoder and projection layers are frozen and only the linear classification heads are trained, these results support the linear separability and transferability of the learned representations. For zero-shot evaluation, the classification accuracy for pleural effusion and pneumothorax improves by 5.81 and 4.85 percentage points, respectively. These results indicate that MedCTA retains an advantage in transferring image-text representations even without training classification heads or updating model parameters. **Overall, MedCTA demonstrates consistent gains on the larger-scale test set under both evaluation protocols. These findings further support the effectiveness of our method when multiple diseases exhibit different directions of change and are consistent with the motivation behind abnormality-conditioned trajectory modeling and hierarchical supervision of clinical changes.**\n\nWe sincerely thank you once again for your continued and careful review throughout this discussion. If these additional experiments further alleviate your concerns, we would greatly appreciate your reconsideration of the overall evaluation of our work in light of the newly added evidence and revisions. \n\nWe have incorporated the additional experiments, evaluation protocols, and results into Appendix A.7 of the revised manuscript.\n\n**Revised manuscript:** [📍 Appendix A.7, pages 17–18](https://openreview.net/pdf?id=QLgyGAhN3P#page=17), lines 901–958."+ },+ "createdAt": "2026-11-18T09:14:38.381Z",+ "modifiedAt": "2026-11-18T09:14:38.381Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=2CMQkCWonJ",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/5ghzu73ln1.json added
+++ b/reviews/openreview/qlgygahn3p/notes/5ghzu73ln1.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "5ghZU73lN1",+ "replyTo": "aWI0FH9EnA",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Response to W1, Q5:\n\n**(3) Trajectory-level and Visit-level Progression Labels**\n\nIn clinical practice, understanding both disease-specific evolution and overall patient disease progression is important for longitudinal clinical assessment. Visit-level supervision, which focuses on a single visit or changes between adjacent visits, primarily captures local changes and cannot directly constrain the overall direction of evolution across the entire patient observation window.\n\nTo address this issue, MedCTA proposes an LLM-driven joint trajectory learning framework. Through disease-level and patient-level trend supervision, it jointly learns disease-specific evolution representations and overall patient progression representations, thereby extending local visit-level change modeling to comprehensive clinical trajectory learning across the entire observation window.\n\nTo evaluate the contributions of complete sequence information and explicit temporal modeling to pre-trained representations, we introduce two comparison variants: First–Last and Mean Pooling. While keeping the training data, both types of trend labels, and supervision losses consistent, First–Last feeds only the first and last visits into the temporal branch, with both image and report sequence lengths set to 2. Mean Pooling retains the complete sequence, replaces the temporal encoder with average pooling along the temporal dimension, and performs the same trend prediction.\n\nAs shown in Tables 2 and 3, the complete MedCTA consistently outperforms both variants across all metrics. Compared with First–Last, MedCTA improves zero-shot ACC by 3.87 and 3.25 percentage points on COVIDx and RSNA, respectively, and improves linear-probe ACC by 3.26 and 0.62 percentage points, respectively. These results indicate that intermediate visit information contributes to learning more comprehensive longitudinal clinical representations. Furthermore, the complete MedCTA outperforms Mean Pooling, further demonstrating the contribution of explicit temporal modeling over simple temporal average aggregation. We have added the First–Last and Mean Pooling baselines to Section 4.3 of the revised manuscript.\n\nTable 2. Zero-shot classification of pre-training variants on COVIDx and RSNA Pneumonia (%).\n\n| Method | ACC (COVID) | F1 (COVID) | AUROC (COVID) | ACC (RSNA) | F1 (RSNA) | AUROC (RSNA) |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| first_last | 74.15 | 60.45 | 86.85 | 64.97 | 55.11 | 85.60 |\n| mean_pooling | 76.76 | 62.84 | 87.42 | 66.51 | 56.37 | 87.49 |\n| MedCTA | 78.02 | 63.93 | 89.62 | 68.22 | 57.91 | 88.60 |\n\nTable 3. Linear-probe classification of pre-training variants on COVIDx and RSNA Pneumonia (%).\n\n| Method | ACC (COVID) | F1 (COVID) | AUROC (COVID) | ACC (RSNA) | F1 (RSNA) | AUROC (RSNA) |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| first_last | 92.40 | 83.37 | 96.63 | 85.43 | 77.69 | 89.65 |\n| mean_pooling | 93.54 | 84.61 | 95.52 | 85.29 | 77.53 | 89.57 |\n| MedCTA | 95.66 | 88.48 | 96.92 | 86.05 | 79.25 | 89.82 |"+ },+ "createdAt": "2026-11-14T10:22:57.719Z",+ "modifiedAt": "2026-11-14T10:22:57.719Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=5ghZU73lN1",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/awi0fh9ena.json added
+++ b/reviews/openreview/qlgygahn3p/notes/awi0fh9ena.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "aWI0FH9EnA",+ "replyTo": "i2nYR7BMM0",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Response to W1, Q5:\n**(1) Non-monotonic Temporal Supervision**\n\nMedCTA learns the dominant direction of change over the entire patient observation window, allowing disease progression to exhibit non-monotonic changes across different visits. Each pre-training sequence contains up to four consecutive visits. Trend annotations are determined based on descriptions explicitly supported by clinical reports, following the priority of magnitude of change, persistence of change, and overall changes in major abnormalities to determine the overall trend within the observation window. We have added the prompt template for extracting temporal trend labels to the revised manuscript.\nDuring pre-training, image and text features from multiple visits are extracted through shared encoders and are used to construct patient-level and abnormality-level trajectory sequences, respectively, which are then temporally modeled using Mamba. Subsequently, patient-level and disease-level trend labels are used to supervise the corresponding trajectory representations. Through this temporal supervision, MedCTA learns longitudinal information about both overall patient disease progression and disease-specific changes.\n\nTo further evaluate whether the representations learned through the aforementioned trend supervision can transfer to multi-disease longitudinal image understanding tasks, we conduct an exploratory evaluation on the Global Trajectory Summarization multi-abnormality subset of MI-CXR [1]. Each sample contains five temporally ordered chest X-rays, one question, and five candidate longitudinal summaries. The task is to select the summary that best matches the evolution of multiple abnormalities.\nThe data were split into training, validation, and test sets at the patient level, with proportions of 80%, 10%, and 10%, respectively. The image and text encoders were frozen to extract features for the five images and five candidate answers. The image features were average-pooled and mapped through a trainable projection head, followed by cosine similarity computation with the candidate text features. During training, the index of the correct answer was used as supervision, and only the projection head was optimized using a five-candidate cross-entropy loss. During testing, answers were selected and ranked according to their similarity scores.\n\nAs shown in Table 1, MedCTA achieves an ACC of 63.30% and an MRR of 79.03%, improving over TAMM by 1.50 and 1.92 percentage points, respectively. F1 and AUROC are also higher. The improvements in ACC and MRR jointly demonstrate advantages in both correct summary selection and ranking, providing exploratory evidence of the model's ability to represent longitudinal disease evolution. We have added the global trajectory summary matching task to Section 4.2.1 of the revised manuscript.\n\nTable 1. Candidate-answer matching on the MI-CXR GTS multi-abnormality set (%).\n\n| Method | ACC | F1 | AUROC | MRR |\n| --- | ---: | ---: | ---: | ---: |\n| TAMM | 61.80 | 59.36 | 86.95 | 77.11 |\n| MedCTA | 63.30 | 62.03 | 88.88 | 79.03 |\n\n[1] MI-CXR: A Benchmark for Longitudinal Reasoning over Multi-Interval Chest X-rays. ACL 2026.\n\n**(2) LLM Annotation Details**\n\nThe offline Qwen2-7B-Instruct model processes complete reports arranged in chronological order and generates trend labels for the patient level and twelve abnormality categories: improvement `1`, stability `0`, and worsening `-1`. The abnormality loss is computed only for valid labels, while non-monotonic processes are summarized according to the aforementioned dominant-trend criteria.\n\nTo further assess the clinical correctness of the trend labels generated by the LLM, we conducted a manual annotation-based evaluation. We randomly sampled 100 longitudinal patient sequences, which were independently annotated by two authors. The average agreement rate between LLM-generated and human-annotated patient-level trend labels was 76%, while the inter-annotator agreement rate was 72%. For disease-level trend labels, the corresponding agreement rates were 69% and 73%, respectively. The agreement between the LLM and human annotations is comparable to the inter-annotator agreement, providing preliminary quantitative support for label quality.\n\nCompared with patient-level trend labeling, disease-level trend recognition requires not only distinguishing among different disease types but also independently determining whether each disease is improving, stable, or worsening. This involves finer-grained semantic understanding and multidimensional judgment, and therefore entails greater annotation complexity. We have added the LLM annotation details to Appendix C.4 of the revised manuscript."+ },+ "createdAt": "2026-11-14T10:21:42.761Z",+ "modifiedAt": "2026-11-14T10:21:42.761Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=aWI0FH9EnA",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/cb6ifccmjb.json added
+++ b/reviews/openreview/qlgygahn3p/notes/cb6ifccmjb.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "CB6iFCCmJB",+ "replyTo": "aWI0FH9EnA",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 6dxU",+ "content": {+ "comment": "I thank the authors for the effort put into the rebuttal, new experiments, human evaluation, and revision. My Q2 and Q3 were fully addressed. A few points are outstanding:\n\n**Q1 is unresolved.** The authors re-explained their methodology, which supervises visit-level representations with global trajectory-level labels. The added GTS experiment supports the suitability of global trend supervision for global summarisation, which is also a trajectory-level task. The added first–last and mean-pooling baselines compare different ways to make use of the same global labels. While valuable additions, neither of these answer my question—which was specifically to clarify the motivation, implications, and limitations of modelling the potentially non-monotonic trajectories by global dominant-trend labels, as opposed to visit-level interval-change labels.\n\n**Q4:** The added details on baselines and provenance of results are appreciated, and TAMM now looks indeed like a strong and fair baseline. This mostly addresses my concern, but further information on the baselines' architectures (esp. TAMM) would strengthen the interpretation of the measured differences (related to Q5).\n\n**Q5 is partially addressed.** The authors expanded the ablations and discussed model limitations in their response (but not explicitly in the manuscript). I believe the interpretation of the improvement of MedCTA over the baselines is still lacking. What makes each baseline worse than MedCTA?"+ },+ "createdAt": "2026-11-16T16:47:25.990Z",+ "modifiedAt": "2026-11-16T16:47:25.990Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=CB6iFCCmJB",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/dvx83zyvyv.json added
+++ b/reviews/openreview/qlgygahn3p/notes/dvx83zyvyv.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "dVx83zYVYv",+ "replyTo": "GxWTOyerQy",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Response to (3) Ablations on temporal image classification\n\nThank you for your suggestion. We agree that the ablation studies on abnormality queries and temporal encoders should also cover the temporal image classification task reported in Table 1 of the manuscript. To this end, we have added complete results for removing abnormality queries and replacing Mamba with GRU. All variants follow the same downstream evaluation protocol: the pre-trained image encoder is frozen, the classification head is trained on Chest ImaGenome, and both the encoder and classification head are frozen during testing on MS-CXR-T.\n\nThe complete MedCTA achieves the highest accuracy across all five abnormalities. Removing abnormality queries reduces accuracy for every abnormality, with the largest decrease of 1.76 percentage points for pneumothorax. Replacing Mamba with GRU also reduces performance across all five abnormalities, with decreases of 5.26, 3.76, and 2.96 percentage points for pneumothorax, edema, and consolidation, respectively. These results support the contributions of abnormality-conditioned feature extraction and the temporal encoder design to abnormality trend recognition. We have added the experiment to Appendix B.8 of the revised manuscript.\n\nTable 3. Temporal image classification accuracy (%) on MS-CXR-T.\n\n| Variant | Consolidation | Edema | Pleural Effusion | Pneumonia | Pneumothorax |\n|---|---:|---:|---:|---:|---:|\n| w/o Abnormality Queries | 66.12 | 69.31 | 64.68 | 72.59 | 59.90 |\n| GRU replacing Mamba | 64.18 | 66.54 | 64.23 | 72.15 | 56.40 |\n| MedCTA | **67.14** | **70.30** | **65.59** | **72.85** | **61.66** |\n\n# Response to (4) Baseline sources\nThank you for your suggestion. We have further revised the manuscript to explicitly distinguish results quoted from Bai et al.'s TAMM paper from those obtained through evaluations conducted in this work. These distinctions are now clarified in table captions, table notes, and figure captions. For metrics with different sources within the same model row, their respective sources are indicated separately. Details regarding model initialization and result provenance are provided in Appendix A.3, while the specific downstream evaluation protocols are described in Appendix A.4.\n\nWe sincerely thank you again for your careful review and continued suggestions. These comments have helped us further strengthen the experiments and clarify the contributions and applicability of our method. We hope that the additional experiments and evidence provided in this revision adequately address your remaining concerns. If you believe that the newly added evidence has alleviated the major concerns and strengthened the overall soundness of the manuscript, we would be grateful if you would reconsider your overall evaluation of the paper. We would also be pleased to provide further clarification on any remaining issues."+ },+ "createdAt": "2026-11-16T08:26:51.248Z",+ "modifiedAt": "2026-11-16T08:26:51.248Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=dVx83zYVYv",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/e7bejx6u4o.json added
+++ b/reviews/openreview/qlgygahn3p/notes/e7bejx6u4o.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "e7beJx6u4O",+ "replyTo": "1xia91yZ3I",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Response to W2, Q3, Q4, Q5:\n**(4) Component Contributions and Limitations**\n\nTables 6 and 10 in the revised manuscript show that the two types of trend supervision are complementary to static alignment. Removing static alignment decreases text-to-image P\\@1 by 22.19 percentage points. Removing the abnormality-level and patient-level trend losses decreases temporal sentence similarity classification ACC by 8.25 and 5.17 percentage points, respectively.\n\nStatic alignment primarily supports cross-modal semantic matching, while the two types of trend supervision separately align disease trajectory changes and overall patient trajectory changes. Among them, abnormality-level trend supervision has a more pronounced impact, which is related to its more direct semantic connection with fine-grained disease change recognition tasks. These results indicate that static alignment, abnormality-level trend supervision, and patient-level trend supervision jointly contribute to clinical representation learning in MedCTA.\n\nAlthough MedCTA achieves promising performance across multiple downstream tasks, it still has several limitations. First, trend labels are primarily extracted automatically by an LLM, and the manual agreement evaluation also shows a relatively lower agreement rate for disease-level labels, indicating that fine-grained disease evolution annotation still involves a degree of uncertainty. Second, the manual evaluation covers only a limited number of longitudinal patient sequences, and its results require further validation using larger-scale, multi-center clinical data. Future work will further improve the quality of trend annotations and validate the generalization capability of the model across more disease types and clinical scenarios."+ },+ "createdAt": "2026-11-14T10:28:45.075Z",+ "modifiedAt": "2026-11-14T10:28:45.075Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=e7beJx6u4O",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/gxwtoyerqy.json added
+++ b/reviews/openreview/qlgygahn3p/notes/gxwtoyerqy.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "GxWTOyerQy",+ "replyTo": "L0JhQlht9Q",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Response to (1) Divergent abnormality trends\n\nThank you for your suggestion. We agree that cases involving different abnormality trends provide a direct test of the motivation for abnormality-specific modeling. To this end, we constructed a *Multi-Disease Trend Disagreement* subset from the MS-CXR-T temporal image classification test set. Each image pair consists of a previous and a current chest X-ray from the same patient, with the trend labels indicating changes in the current image relative to the previous one. The selection criteria are as follows: at least two of the five target diseases must have non-null trend labels, and at least two distinct trend categories must be present among these labels, namely improvement, stability, or worsening. This subset contains 60 image pairs. Based on the combinations of trend categories present in each image pair, 26 pairs contain both stability and worsening, 23 pairs contain both improvement and stability, and 11 pairs contain both improvement and worsening. We follow the original temporal image classification evaluation protocol to compare MedCTA with TAMM and report the classification accuracy for each abnormality.\n\nAs shown in Table 1, MedCTA achieves higher classification accuracy than TAMM for all five abnormalities. The largest improvements are observed for pleural effusion and consolidation, with gains of 2.94 and 2.89 percentage points, respectively. MedCTA also improves accuracy for edema, pneumonia, and pneumothorax by 1.50, 0.95, and 1.59 percentage points, respectively. These results support the trend recognition advantage of MedCTA on this subset with different abnormality trends and are consistent with the motivation for abnormality-specific modeling. We have added the experiment to Appendix A.7 of the revised manuscript.\n\nTable 1. Temporal image classification accuracy (%) on the MS-CXR-T subset with different abnormality trends.\n\n| Method | Consolidation | Edema | Pleural Effusion | Pneumonia | Pneumothorax |\n|---|---:|---:|---:|---:|---:|\n| TAMM | 60.83 | 65.17 | 60.91 | 70.48 | 55.46 |\n| MedCTA | **63.72** | **66.67** | **63.85** | **71.43** | **57.05** |\n\n# Response to (2) Zero-shot Comparison with MGCA\n\nThank you for your suggestion. MGCA is a representative method in medical vision-language pre-training, and its multi-granularity cross-modal alignment provides an effective foundation for medical image-text representation learning. MedCTA also uses MGCA pre-trained weights for initialization. Therefore, a direct comparison with MGCA is particularly important for clarifying the value of MedCTA beyond this foundation.\nTo this end, we have added zero-shot results for MGCA. The evaluation follows the same protocol, with the image and text encoders frozen and classification performed based on the cosine similarity between images and class texts. The complete comparison is presented in Table 2.\n\nCompared with MGCA, MedCTA improves ACC, F1, and AUROC on RSNA by 9.52, 2.56, and 5.63 percentage points, respectively, and on COVIDx by 16.21, 12.85, and 11.92 percentage points, respectively. These results highlight MedCTA’s stronger zero-shot transfer through clinical trajectory alignment beyond MGCA initialization. We have added the results to Table 5 of the revised manuscript.\n\nTable 2. Zero-shot image classification results on RSNA and COVIDx (%). Boldface indicates the highest value in each column.\n\n| Method | RSNA ACC | RSNA F1 | RSNA AUROC | COVIDx ACC | COVIDx F1 | COVIDx AUROC |\n|---|---:|---:|---:|---:|---:|---:|\n| MGCA | 58.70 | 55.35 | 82.97 | 61.81 | 51.08 | 77.70 |\n| ALTA | 65.40 | 56.69 | 82.13 | 62.70 | 49.03 | 85.95 |\n| TAMM | 66.85 | 56.19 | 81.62 | 76.12 | 59.19 | 86.15 |\n| MedCTA | **68.22** | **57.91** | **88.60** | **78.02** | **63.93** | **89.62** |"+ },+ "createdAt": "2026-11-16T08:23:06.641Z",+ "modifiedAt": "2026-11-16T08:23:06.641Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=GxWTOyerQy",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/hn9il1eji7.json added
+++ b/reviews/openreview/qlgygahn3p/notes/hn9il1eji7.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Hn9iL1eJI7",+ "replyTo": "mDLprbIhqA",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer 6dxU,\n\nThank you for your careful review and constructive feedback throughout the discussion. In our latest responses, we have clarified the complementary roles of global dominant-trend and interval-level supervision, acknowledged the inability of global labels to capture local reversals, and added architectural comparisons with TAMM and further ablation analyses. We have also summarized the limitations of MedCTA in Appendix C.6 of the revised manuscript.\n\n**Revised manuscript:** [📍 Appendix C.6, page 25](https://openreview.net/pdf?id=QLgyGAhN3P#page=25), lines 1320–1327.\n\nWe hope these clarifications address your remaining concerns. If so, we would be grateful if you could reconsider your overall assessment in light of the revisions.\n\nThank you again for your time and thoughtful suggestions.\n\nBest regards,\n\nThe authors"+ },+ "createdAt": "2026-11-18T09:25:02.370Z",+ "modifiedAt": "2026-11-18T09:25:02.370Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=Hn9iL1eJI7",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/hq9zev2jvi.json added
+++ b/reviews/openreview/qlgygahn3p/notes/hq9zev2jvi.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "HQ9zEv2jVI",+ "replyTo": "xiXVhjL2My",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Response to W2, Q1, Q2, Q3:\n**(1) Baseline Details**\n\nWe categorize the baseline results according to their sources:\n\n- Quoted results: ACC for temporal image classification, ACC for temporal sentence similarity classification, cross-modal retrieval metrics, and ACC and F1 for RSNA/COVIDx linear probing are quoted from the TAMM paper.\n- Reproduced results: AUROC for temporal sentence similarity classification and RSNA/COVIDx classification. Specifically, TAMM was retrained following its original method on the same patient-excluded data as MedCTA, while the remaining baselines were evaluated using their official pre-trained weights.\n\nMedCTA follows the initialization strategy of TAMM, using publicly available MGCA weights for initialization, followed by temporal pre-training on the patient-excluded dataset. The initialization of the remaining baselines follows the experimental configurations reported in the TAMM paper. The parameter counts of all models are reported in Table 6. We have added the baseline details to Appendix A.3 of the revised manuscript.\n\nTable 6. Model parameter counts (M)\n\n| Method | Parameters (M) |\n| --- | ---: |\n| MGCA | 172.73 |\n| MedCLIP | 133.26 |\n| PRIOR | 159.92 |\n| MAVL | 170.65 |\n| CARZero | 220.77 |\n| Med-ST | 233.76 |\n| ALTA | 265.65 |\n| TAMM | 321.91 |\n| MedCTA | 198.70 |\n\n**(2) Experimental Data Splits**\n\nWhen constructing the MedCTA temporal pre-training dataset, we excluded downstream patients based on patient IDs (subject_id). MS-CXR-T, MIMIC-5×200, and the Chest ImaGenome used in our experiments involve 800, 957, and 16,001 patients, respectively. We took the union of the patient sets from these three datasets and excluded all images and reports belonging to these patients from MIMIC-CXR before constructing longitudinal sequences. The resulting pre-training dataset contains 46,564 patients and 61,164 sequences. We have added details of the data split to Appendix A.1 of the revised manuscript.\n\n**(3) Zero-shot Evaluation Protocol**\n\nIn the original manuscript, the RSNA Pneumonia and COVIDx experiments used training labels from the target datasets and trained only a linear classifier while keeping the image encoder frozen. These experiments should therefore be referred to as Linear Probe. Similarly, works such as TAMM (AAAI 2026) also adopt Linear Probe to evaluate the representation capability of pre-trained image encoders on downstream tasks. We have consistently revised the main text, table captions, and related conclusions to distinguish Linear Probe from Zero-shot Evaluation.\n\nWe have also added a fully zero-shot evaluation: frozen pre-trained image and text encoders are used to extract image and class-text features, respectively, followed by classification based on cosine similarity. All baseline models adopt the same evaluation protocol. As shown in Table 7, MedCTA outperforms TAMM and ALTA on ACC, F1, and AUROC across both datasets. We have revised the content of Section 4.2.2 and the relevant table captions in the revised manuscript.\n\nTable 7. Zero-shot image classification on COVIDx and RSNA (%)\n| Method | ACC (COVID) | F1 (COVID) | AUROC (COVID) | ACC (RSNA) | F1 (RSNA) | AUROC (RSNA) |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| ALTA | 62.70 | 49.03 | 85.95 | 65.40 | 56.69 | 82.13 |\n| TAMM | 76.12 | 59.19 | 86.15 | 66.85 | 56.19 | 81.62 |\n| MedCTA | 78.02 | 63.93 | 89.62 | 68.22 | 57.91 | 88.60 |"+ },+ "createdAt": "2026-11-14T10:13:29.159Z",+ "modifiedAt": "2026-11-14T10:13:29.159Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=HQ9zEv2jVI",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/i2nyr7bmm0.json added
+++ b/reviews/openreview/qlgygahn3p/notes/i2nyr7bmm0.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "i2nYR7BMM0",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer 6dxU",+ "content": {+ "paper_summary": "The proposed MedCTA framework supplements contrastive vision–language modelling in medical imaging with progression supervision from full patient trajectories.\nGlobal progression labels are extracted offline by an LLM from a sequence of reports, separately for specific abnormalities and for the full patient course.\nAbnormality-specific (computed via cross-attention) and patient-course representation trajectories are temporally aggregated then classified following the extracted labels.\nThe method is evaluated on a suite of cross-modal and temporal tasks, and compared with multiple temporal and non-temporal VLM baselines.\nReported results imply consistent improvements across all evaluated tasks.",+ "presentation": 3,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "The work builds on a growing body of literature acknowledging the need to model temporality in radiology.\nRadiology scans are often reported incrementally, with explicit mentions of change, and sometimes cannot be interpreted without access to patient history (e.g. findings reported as \"unchanged\").\nThis is a crucial domain-specific consideration that is not addressed by conventional single-visit or general-domain methods. \n\nThe approach of explicitly modelling progression of individual abnormalities in addition to overall patient course is interesting and well motivated.\nIts proposed methodological implementation with learned queries and cross-attention over visual and textual tokens, followed by temporal classification, seems like an appropriate design.\nEven if generally there are important limitations to assuming a fixed panel of abnormalities, this signal is only used for additional supervision and is not necessarily detrimental for representation learning.",+ "critical_weaknesses": "One of my key concerns regards the suitability of the proposed temporal supervision scheme, which relies on trajectory-level progression labels.\nTrajectories are often non-monotonic, especially at the patient level (e.g. throughout a long ICU stay).\nThis limitation is very briefly acknowledged in Appendix C.3 without further discussion.\nWhy not supervise with visit-level progression labels, which seems perfectly compatible with the Mamba head?\nRelatedly, it is not clear what image representations are expected to gain from temporal supervision—can you guess from a single radiograph whether the patient is improving overall?\nLastly, the authors provided virtually no detail about the labelling process itself (prompts, sampling settings, evaluation, handling of uncertain progression, etc.), making it impossible to assess or replicate.\n\nMy second major concern is that it is not clear what exactly is being demonstrated in the experiments.\nThe authors have not specified what MedCTA representations are used in the downstream tasks: encoder global representations vs Mamba outputs? single- vs multi-visit? abnormality- vs patient-scope? etc.\nThis is further disorienting because the inputs/outputs of the evaluation tasks are never fully stated.\nMoreover, the baselines were described at high level in Appendix A.3, but without mention of architectures, parameter counts, or training data, which can greatly confound the interpretation of results and may undermine methodological improvement claims.\nThe dynamic phrase grounding evaluation comprises just three qualitative heatmap examples, with no attempt to quantify spatial localisation across a dataset or compare with other models.\nFinally, discussion of results for each experiment was generally quite shallow, with limited insight on *how* the method's components might have led to improved results on each task.",+ "questions_for_authors": "1. The assumption of monotonic progression at both abnormality- and patient-scope needs further justification, and its trade-offs should be discussed.\n2. Because the LLM parsing is listed as a core contribution, the process must be described in detail to allow judging its appropriateness. Also, please clarify whether the labelling itself was evaluated for correctness against human ground truth (not just downstream performance).\n3. Specify precisely how the MedCTA model interfaces with each of the downstream tasks (inputs/outputs).\n4. Add the missing details for the chosen baselines, discuss possible confounders, and contextualise the fairness of the reported comparisons. If the baselines were retrained by the authors with similar settings to MedCTA, this must be stated explicitly, as it would significantly strengthen the reported evidence.\n5. Elaborate on the discussion of experimental findings: which design choices improved results and why (also contextualising with the ablations)? how does it compare to the baselines, and are there any patterns/trends amongst them? what are limitations of the proposed method? etc.",+ "flag_for_ethics_review": "No",+ "rating": 3,+ "confidence": 3+ },+ "createdAt": "2026-10-19T10:35:35.548Z",+ "modifiedAt": "2026-11-18T11:58:34.829Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=i2nYR7BMM0",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/j6gejchazq.json added
+++ b/reviews/openreview/qlgygahn3p/notes/j6gejchazq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "j6gejchAZq",+ "replyTo": "Q88wAIteat",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer WBuE",+ "content": {+ "comment": "Thank you for the thorough responses and for running all the additional experiments. The results on the subset with divergent abnormality trends, comparison with MGCA, the ablations on temporal image classification, and the clarified sources of the baseline numbers address the questions I raised. The MGCA comparison shows a clear gain over the initialization, and the ablations show that both the abnormality queries and the temporal encoder contribute to trend recognition. I remain somewhat concerned that the gains on the divergent-trend subset are modest and come from only 60 pairs. Given these additions, I am raising my score from 1 to 2."+ },+ "createdAt": "2026-11-17T09:18:53.101Z",+ "modifiedAt": "2026-11-17T09:18:53.101Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=j6gejchAZq",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/jfh0k5cajm.json added
+++ b/reviews/openreview/qlgygahn3p/notes/jfh0k5cajm.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Jfh0K5CaJm",+ "replyTo": "MWcxy01Nax",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Response to W2, Q3:\n**(1) Contribution of Temporal Modeling**\n\nWe added First–Last and Mean Pooling baselines while keeping the training data, patient-level and disease-level three-class labels, and losses consistent. First–Last feeds only the first and last visits into the temporal branch, with both image and report sequence lengths set to 2. Mean Pooling retains the complete sequence, replaces the temporal encoder with average pooling along the temporal dimension, and performs the same trend prediction.\n\nAs shown in Tables 3 and 4, the complete MedCTA consistently outperforms both variants across all metrics. Compared with First–Last, MedCTA improves zero-shot ACC by 3.87 and 3.25 percentage points on COVIDx and RSNA, respectively, and improves linear-probe ACC by 3.26 and 0.62 percentage points, respectively. These results indicate that intermediate visit information contributes to learning more comprehensive longitudinal clinical representations. Furthermore, the complete MedCTA outperforms Mean Pooling, further demonstrating the contribution of explicit temporal modeling over simple temporal average aggregation. We have added details of the First–Last and Mean Pooling baselines to Section 4.3 of the revised manuscript.\n\nTable 3. Zero-shot classification of pre-training variants on COVIDx and RSNA (%)\n| Method | ACC (COVID) | F1 (COVID) | AUROC (COVID) | ACC (RSNA) | F1 (RSNA) | AUROC (RSNA) |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| first_last | 74.15 | 60.45 | 86.85 | 64.97 | 55.11 | 85.60 |\n| mean_pooling | 76.76 | 62.84 | 87.42 | 66.51 | 56.37 | 87.49 |\n| MedCTA | 78.02 | 63.93 | 89.62 | 68.22 | 57.91 | 88.60 |\n\nTable 4. Linear probing of pre-training variants on COVIDx and RSNA (%)\n| Method | ACC (COVID) | F1 (COVID) | AUROC (COVID) | ACC (RSNA) | F1 (RSNA) | AUROC (RSNA) |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| first_last | 92.40 | 83.37 | 96.63 | 85.43 | 77.69 | 89.65 |\n| mean_pooling | 93.54 | 84.61 | 95.52 | 85.29 | 77.53 | 89.57 |\n| MedCTA | 95.66 | 88.48 | 96.92 | 86.05 | 79.25 | 89.82 |\n\n**(2) Clinical Correctness of LLM-generated Labels**\n\nTo further assess the clinical correctness of the trend labels generated by the LLM, we conducted a manual annotation-based evaluation. We randomly sampled 100 longitudinal patient sequences, which were independently annotated by two authors. The average agreement rate between LLM-generated and human-annotated patient-level trend labels was 76%, while the inter-annotator agreement rate was 72%. For disease-level trend labels, the corresponding agreement rates were 69% and 73%, respectively. The agreement between the LLM and human annotations is comparable to the inter-annotator agreement, providing preliminary quantitative support for label quality. We have added details of the Clinical Correctness of LLM-generated Labels to Appendix C.4 of the revised manuscript.\n\n**(3) Evaluation of Representation Capability for Disease Evolution and Clinical Trajectories**\n\nWe conducted an exploratory candidate-answer matching evaluation on the Global Trajectory Summarization (GTS) multi-abnormality subset of MI-CXR [1]. Each sample contains five temporally ordered chest X-rays, one question, and five candidate longitudinal summaries, covering the evolution of multiple abnormalities at different time points. The task requires selecting the summary that best matches the image sequence.\n\nThe data were split into training, validation, and test sets at the patient level, with proportions of 80%, 10%, and 10%, respectively. The image and text encoders were frozen to extract features for the five images and five candidate answers. The image features were average-pooled and mapped through a trainable projection head, followed by cosine similarity computation with the candidate text features. During training, the index of the correct answer was used as supervision, and only the projection head was optimized using a five-candidate cross-entropy loss. During testing, answers were selected and ranked according to their similarity scores.\n\nAs shown in Table 5, MedCTA achieves an ACC of 63.30% and an MRR of 79.03%, improving over TAMM by 1.50 and 1.92 percentage points, respectively. F1 and AUROC are also higher. The improvements in ACC and MRR jointly demonstrate advantages in both correct summary selection and ranking, providing exploratory evidence of the model's ability to represent longitudinal disease evolution. We have added the global trajectory summary matching task to Section 4.2.1 of the revised manuscript.\n\nTable 5. Candidate-answer matching on the MI-CXR GTS multi-abnormality set (%)\n| Method | ACC | F1 | AUROC | MRR |\n| --- | ---: | ---: | ---: | ---: |\n| TAMM | 61.80 | 59.36 | 86.95 | 77.11 |\n| MedCTA | 63.30 | 62.03 | 88.88 | 79.03 |\n\n[1] MI-CXR: A Benchmark for Longitudinal Reasoning over Multi-Interval Chest X-rays. ACL 2026.\n\n**(4) Prompt Template** \n\nWe have added details of Prompt Template to Appendix E of the revised manuscript."+ },+ "createdAt": "2026-11-14T09:59:54.198Z",+ "modifiedAt": "2026-11-14T09:59:54.198Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=Jfh0K5CaJm",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/khad54yugq.json added
+++ b/reviews/openreview/qlgygahn3p/notes/khad54yugq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "KHaD54yugq",+ "replyTo": "Hn9iL1eJI7",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 6dxU",+ "content": {+ "comment": "Thank you for the additional discussion.\nRegarding Q1, my persistent confusion is not *how*, but the motivation for *why* the authors are focusing on modelling global trends, given the acknowledgement that non-monotonicity is a real issue and that richer visit-level labels are readily available.\nOtherwise, the additional context provided about the baseline comparisons is very helpful and resolves my Q4 and Q5.\nAccounting for the entire discussion and revisions, and assuming the authors will integrate the latest clarifications in the final paper, I am willing to raise my Presentation score and recommendation."+ },+ "createdAt": "2026-11-18T11:58:17.275Z",+ "modifiedAt": "2026-11-18T11:58:17.275Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=KHaD54yugq",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/l0jhqlht9q.json added
+++ b/reviews/openreview/qlgygahn3p/notes/l0jhqlht9q.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "L0JhQlht9Q",+ "replyTo": "VzE8NxpQpc",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer WBuE",+ "content": {+ "comment": "Thank you for the detailed rebuttal and the additional experiments. The clarifications on data exclusion, evaluation protocols, and dual-image adaptation address several of my concerns. I have a few remaining questions:\n\n**1. Divergent abnormality trends.** Could you report results on test cases in which abnormalities change in different directions? This would directly support the motivation for abnormality-specific trajectories.\n\n**2. Zero-shot comparison with MGCA.** Since MedCTA is initialized from MGCA, could you include MGCA in the zero-shot comparison? This would help separate the effect of continued pre-training from that of temporal supervision.\n\n**3. Ablations on temporal image classification.** Neither the abnormality-query ablation nor the temporal-encoder ablation reports temporal image classification (Table 1). Could you report these results?\n\n**4. Baseline sources.** Thank you for clarifying which baseline results were quoted and which were reproduced. Please make sure that the revised manuscript states the source of each reported number, as you indicated."+ },+ "createdAt": "2026-11-15T11:27:55.735Z",+ "modifiedAt": "2026-11-15T11:27:55.735Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=L0JhQlht9Q",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/mdlprbihqa.json added
+++ b/reviews/openreview/qlgygahn3p/notes/mdlprbihqa.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "mDLprbIhqA",+ "replyTo": "xsVPmQ0fOc",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Further Response to Q5:\nThank you for this follow-up question. We believe that MedCTA's performance gains over existing baselines stem primarily from how it represents and learns longitudinal clinical changes, particularly through the following two aspects.\n\n(1) Dual-scope trajectory modeling and alignment capture both abnormality-specific evolution and overall patient-course progression. Static medical VLP methods primarily focus on visit-level image–report alignment. Med-ST incorporates historical image–text information through cross-modal cycle consistency, ALTA models temporal views through masked pre-training, and TAMM learns local changes using adjacent-visit trend labels and clinical rationales. In contrast, MedCTA explicitly constructs multi-visit abnormality-specific and patient-course trajectories, supervised through Abnormality-Specific Trajectory Alignment and Patient-Course Progression Alignment. This design enables the model to represent heterogeneous changes across abnormalities while capturing overall clinical progression. Table 13 shows that removing either trajectory-level objective reduces text-to-image retrieval P@1. Furthermore, MedCTA outperforms TAMM across all five abnormalities on the 60-pair Multi-Disease Trend Disagreement subset (Appendix A.7), providing additional evidence consistent with the motivation for abnormality-specific modeling.\n\n(2) Abnormality-conditioned representations and ordered multi-visit encoding enable more effective integration of longitudinal information. MedCTA employs clinically initialized abnormality queries to extract abnormality-relevant visual and textual representations, which are organized into trajectories and temporally encoded using Mamba. In Table 7, MedCTA achieves higher zero-shot classification accuracy on RSNA Pneumonia (68.22%) than First–Last (64.97%) and Mean Pooling (66.51%). Appendix B.8 further shows that removing abnormality queries or replacing Mamba with GRU reduces temporal image classification accuracy across all five abnormalities, supporting the contributions of these architectural choices.\n\nOverall, MedCTA integrates abnormality-conditioned trajectory construction, ordered multi-visit modeling, and dual-scope clinical-change alignment within a unified pre-training framework. The ablation studies support the effectiveness of these design choices, while comparisons with TAMM show higher reported accuracy across all five abnormalities in temporal image classification (Table 1) and better performance on seven of eight cross-modal retrieval metrics (Table 3). \n\nWe have summarized the limitations in Appendix C.6 of the revised manuscript.\n\n**Revised manuscript:** [📍 Appendix C.6, page 25](https://openreview.net/pdf?id=QLgyGAhN3P#page=25), lines 1320–1327."+ },+ "createdAt": "2026-11-17T13:03:08.270Z",+ "modifiedAt": "2026-11-18T09:23:34.200Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=mDLprbIhqA",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/mwcxy01nax.json added
+++ b/reviews/openreview/qlgygahn3p/notes/mwcxy01nax.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "MWcxy01Nax",+ "replyTo": "oCV1uj2E23",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Response to W1, Q1, Q2:\n**(1) Zero-shot Evaluation Protocol**\n\nIn the original manuscript, the RSNA Pneumonia and COVIDx experiments used training labels from the target datasets and trained only a linear classifier while keeping the image encoder frozen. These experiments should therefore be referred to as Linear Probe. Similarly, works such as TAMM (AAAI 2026) also adopt Linear Probe to evaluate the representation capability of pre-trained image encoders on downstream tasks. We have also added a fully zero-shot evaluation: frozen pre-trained image and text encoders are used to extract image and class-text features, respectively, followed by classification based on cosine similarity. All baseline models adopt the same evaluation protocol. As shown in Table 1, MedCTA outperforms TAMM and ALTA on ACC, F1, and AUROC across both datasets. We have revised the content of Section 4.2.2 and the relevant table captions in the revised manuscript.\n\nTable 1. Zero-shot image classification on COVIDx and RSNA (%)\n| Method | ACC (COVID) | F1 (COVID) | AUROC (COVID) | ACC (RSNA) | F1 (RSNA) | AUROC (RSNA) |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| ALTA | 62.70 | 49.03 | 85.95 | 65.40 | 56.69 | 82.13 |\n| TAMM | 76.12 | 59.19 | 86.15 | 66.85 | 56.19 | 81.62 |\n| MedCTA | 78.02 | 63.93 | 89.62 | 68.22 | 57.91 | 88.60 | \n\n**(2) Experimental Data Splits**\n\nWhen constructing the MedCTA temporal pre-training dataset, we excluded downstream patients based on patient IDs (subject_id). MS-CXR-T, MIMIC-5×200, and the Chest ImaGenome used in our experiments involve 800, 957, and 16,001 patients, respectively. We took the union of the patient sets from these three datasets and excluded all images and reports belonging to these patients from MIMIC-CXR before constructing longitudinal sequences. The resulting pre-training dataset contains 46,564 patients and 61,164 sequences. We have added details of the data split to Appendix A.1 of the revised manuscript.\n\n**(3) Baseline Details**\n\nWe categorize the baseline results according to their sources:\n\n- Quoted results: ACC for temporal image classification, ACC for temporal sentence similarity classification, cross-modal retrieval metrics, and ACC and F1 for RSNA/COVIDx linear probing are taken from the TAMM paper.\n- Reproduced results: AUROC for temporal sentence similarity classification and RSNA/COVIDx classification. Specifically, TAMM was retrained following its original method on the same patient-excluded data as MedCTA, while the remaining baselines were evaluated using their official pre-trained weights.\n\nMedCTA follows the initialization strategy of TAMM, using publicly available MGCA weights for initialization, followed by temporal pre-training on the patient-excluded dataset. The initialization of the remaining baselines follows the experimental configurations reported in the TAMM paper. The parameter counts of all models are reported in Table 2. We have added the baseline details to Appendix A.3 of the revised manuscript.\n\nTable 2. Model parameter counts (M)\n| Method | Parameters (M) |\n| --- | ---: |\n| MGCA | 172.73 |\n| MedCLIP | 133.26 |\n| PRIOR | 159.92 |\n| MAVL | 170.65 |\n| CARZero | 220.77 |\n| Med-ST | 233.76 |\n| ALTA | 265.65 |\n| TAMM | 321.91 |\n| MedCTA | 198.70 |"+ },+ "createdAt": "2026-11-14T09:50:58.766Z",+ "modifiedAt": "2026-11-14T09:50:58.766Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=MWcxy01Nax",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/ocv1uj2e23.json added
+++ b/reviews/openreview/qlgygahn3p/notes/ocv1uj2e23.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "oCV1uj2E23",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Mw8J",+ "content": {+ "paper_summary": "The paper proposes MedCTA, a medical vision-language pre-training framework that combines static image–report alignment with abnormality-specific and patient-level temporal modeling, supervised by LLM-generated trend labels. Experiments on temporal classification, cross-modal retrieval, and disease classification generally outperform the reported baselines, while ablations support the contribution of both temporal objectives.",+ "presentation": 2,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "**1. The dual-scope formulation addresses a meaningful limitation of longitudinal representation learning.**\nModeling each abnormality separately while retaining a patient-level progression branch is well motivated by heterogeneous clinical evolution. This is more informative than assigning a single undifferentiated representation to the entire patient history. Removing either temporal objective degrades performance in the reported temporal-task ablations, providing evidence that both supervision scopes are useful within the proposed framework.\n\n**2. The empirical evaluation covers both temporal understanding and conventional cross-modal tasks.**\nMedCTA improves all five reported temporal image classification categories and seven of eight retrieval metrics, while showing a substantial improvement in temporal sentence similarity accuracy over TAMM (95.72% versus 88.88%). The parser-replacement, order-perturbation, and label-noise experiments provide additional checks beyond the main comparisons. Together, these results suggest that the proposed supervision can improve representations across multiple tasks, although the image-classification gains are more modest than the language-side gains.",+ "critical_weaknesses": "**1. The evaluation protocol is insufficiently specified to establish the interpretation and fairness of several key results.**\nSection 4.2.2 describes RSNA Pneumonia and COVIDx evaluation as zero-shot, whereas Appendix A.4 states that these experiments involve training a lightweight classifier. Whether this classifier uses target-dataset labels fundamentally changes the claim being evaluated. In addition, Appendix A.2 states that downstream data are disjoint from pre-training data, but does not specify patient-level exclusions or how overlap is prevented across the MIMIC-derived benchmarks. Since MedCTA also starts from MGCA weights, the initialization and subsequent training budgets used for the baselines need to be explicit. These omissions prevent a confident assessment of the reported transfer gains.\n\n**2. The evidence does not sufficiently isolate the claimed benefit of trajectory modeling from that of additional coarse trend supervision.**\nEach abnormality trajectory and patient course is ultimately supervised by a single three-class label. The paper does not compare its temporal encoders against simpler aggregation or first–last-visit alternatives under otherwise identical supervision. Shuffling visits while retaining the original labels disrupts the relationship between inputs and targets; the resulting degradation establishes sensitivity to this disruption but does not by itself demonstrate the necessity of the proposed temporal architecture. Furthermore, reversal consistency and synthetic random-noise tests do not establish the clinical correctness of the original LLM labels. The acknowledged non-monotonic failure case illustrates why this matters. These limitations weaken the stronger interpretation that the framework learns detailed clinical trajectories, rather than useful sequence-level trend classification.",+ "questions_for_authors": "1. For RSNA Pneumonia and COVIDx, what exactly is trained, on which data and labels, and which parameters are updated? How should the statement in Appendix A.4 about training a lightweight classifier be reconciled with the zero-shot designation? Were all baselines evaluated using precisely the same protocol?\n\n2. Please specify the pre-training patient/sequence counts and patient-level exclusion procedure for the downstream benchmarks. Does the non-overlap guarantee also cover the data used to train the MGCA initialization? What initialization, training data, and additional optimization budget were used for each baseline?\n\n3. Was a representative subset of abnormality-level and patient-level labels independently assessed by human annotators? If so, please report the sample size, annotation criteria, and agreement with the LLM. Please also provide the extraction prompts and explain how mixed or non-monotonic trajectories are assigned a single label, and how pre-existing temporal comparison language is handled during reversal filtering.",+ "flag_for_ethics_review": "No",+ "rating": 3,+ "confidence": 3+ },+ "createdAt": "2026-10-21T06:43:14.420Z",+ "modifiedAt": "2026-11-06T12:24:56.239Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=oCV1uj2E23",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/q88waiteat.json added
+++ b/reviews/openreview/qlgygahn3p/notes/q88waiteat.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Q88wAIteat",+ "replyTo": "dVx83zYVYv",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer WBuE,\n\nThank you again for your careful review and constructive suggestions. We have provided additional experiments and clarifications in response to the concerns raised in the second round, and we sincerely hope that these additions have addressed your remaining concerns. Your assessment is of great importance to us and will help us gain a more accurate understanding of both the contributions and limitations of our work.\n\nWe would be grateful for any further feedback you may have on our current response. We would be more than willing to provide additional clarification or supplementary results for any issues that remain unresolved. We sincerely look forward to your further comments.\n\nBest regards,\n\nThe authors"+ },+ "createdAt": "2026-11-17T01:18:32.557Z",+ "modifiedAt": "2026-11-17T01:18:32.557Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=Q88wAIteat",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/tn9ajlgnrn.json added
+++ b/reviews/openreview/qlgygahn3p/notes/tn9ajlgnrn.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "tn9AJlgnRN",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer WBuE",+ "content": {+ "paper_summary": "The paper proposes MedCTA, a medical vision-language pre-training framework for learning longitudinal clinical change from chest X-ray and report sequences. It models abnormality-specific evolution through abnormality-conditioned trajectories constructed with learnable queries, and patient-course progression through sequences of global image and report features. Both are encoded with Mamba and supervised using LLM-derived trend labels: improving, stable, or worsening. These objectives are combined with static image–report alignment.",+ "presentation": 2,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "- Modeling each abnormality separately is well motivated. Different abnormalities in the same patient can progress in different directions. Constructing a separate trajectory for each abnormality is a reasonable way to preserve these differences, which may be lost in a single patient-level representation.",+ "critical_weaknesses": "- The experiments do not directly establish the main contribution beyond TAMM [1]. TAMM already uses LLM-derived three-class trend labels to supervise trend prediction in both modalities. MedCTA extends this approach with abnormality-conditioned trajectories and patient-course progression modeling, but the experiments do not directly evaluate patient-course trend prediction or cases where abnormalities progress in different directions. The loss ablations, query initialization comparison, and visit-order perturbation provide useful evidence, but do not isolate the benefit of abnormality queries themselves or of using Mamba rather than a simpler temporal encoder.\n- It is unclear whether the baseline results were obtained under a common evaluation protocol. Section 4.1 states that baselines are reproduced using official implementations where available, yet all baseline results in Table 1, including standard deviations, exactly match those reported in TAMM. This needs clarification: were these results reproduced or taken from prior work? Given the modest improvements over TAMM on temporal image classification, uncertainty about the evaluation protocol makes these gains difficult to assess.\n\n[1] Bai, Liang, et al. “Medical Vision–Language Pretraining with LLM-Guided Temporal Supervision.” Proceedings of the AAAI Conference on Artificial Intelligence (AAAI), 2026.",+ "questions_for_authors": "1. Which baseline results were reproduced under the current evaluation protocol, and which were taken from prior work? Please also explain the discrepancy between the MGCA Consolidation result in Table 1 (44.99 ± 0.47) and that reported in Med-ST (50.79 ± 0.44).\n2. MS-CXR-T, Chest ImaGenome, and MIMIC-5×200 are derived from MIMIC-CXR. Which patients or studies were excluded from pre-training to prevent overlap with downstream evaluation data?\n3. Table 3 is described as zero-shot classification, but Appendix A.4 states that a lightweight classifier is trained on the pre-trained representations. What data and labels are used to train this classifier, and in what sense is the evaluation zero-shot?\n4. Appendix C.3 mentions a manual evaluation. Could you report agreement between the LLM-generated labels and human annotations for both abnormality-specific and patient-course trends? Please also specify the abnormality set and the label distributions for both types of supervision.\n5. How does performance change when abnormality queries are removed or Mamba is replaced with a simpler temporal encoder?\n6. How is the pre-trained sequence model adapted to the two-image setting of MS-CXR-T? Please clarify how the image pair is encoded and which components are fine-tuned.",+ "flag_for_ethics_review": "No",+ "rating": 2,+ "confidence": 4+ },+ "createdAt": "2026-10-20T09:21:12.202Z",+ "modifiedAt": "2026-11-17T09:19:40.507Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=tn9AJlgnRN",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/vze8nxpqpc.json added
+++ b/reviews/openreview/qlgygahn3p/notes/vze8nxpqpc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "VzE8NxpQpc",+ "replyTo": "HQ9zEv2jVI",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Response to Q4, Q6:\n**(1) Evaluation of the Correctness of LLM-generated Labels**\n\nTo further assess the clinical correctness of the trend labels generated by the LLM, we conducted a manual annotation-based evaluation. We randomly sampled 100 longitudinal patient sequences, which were independently annotated by two authors. The average agreement rate between LLM-generated and human-annotated patient-level trend labels was 76%, while the inter-annotator agreement rate was 72%. For disease-level trend labels, the corresponding agreement rates were 69% and 73%, respectively. The agreement between the LLM and human annotations is comparable to the inter-annotator agreement, providing preliminary quantitative support for label quality.\n\nCompared with patient-level trend labeling, disease-level trend recognition requires not only distinguishing among different disease types but also independently determining whether each disease is improving, stable, or worsening. This involves finer-grained semantic understanding and multidimensional judgment, and therefore entails greater annotation complexity. We have added the evaluation of the correctness of LLM-generated labels to Appendix C.4 of the revised manuscript.\n\n**(2) Abnormality Category Set**\n\nThe pre-training data cover 12 abnormality categories, including: Enlarged Cardiomediastinum, Cardiomegaly, Lung Lesion, Lung Opacity, Edema, Consolidation, Pneumonia, Atelectasis, Pneumothorax, Pleural Effusion, Pleural Other, and Fracture.\n\nTo further characterize the composition of longitudinal trend labels in the pre-training data, we counted the distributions of patient-level and individual disease-level trend labels across different directions of change, as shown in Table 8. Here, 1, 0, and -1 represent improvement, stability, and worsening, respectively. We have added details of the abnormality category set to Appendix C.5 of the revised manuscript.\n\nTable 8. Patient-level and abnormality-level trend label distributions\n\n| Scope / Abnormality | Improve (1) | Stable (0) | Worse (-1) |\n| --- | ---: | ---: | ---: |\n| Patient | 20478 | 15547 | 25139 |\n| Cardiomegaly | 390 | 25303 | 2928 |\n| Enlarged Cardiomediastinum | 1088 | 24319 | 5214 |\n| Lung Lesion | 1153 | 993 | 2136 |\n| Lung Opacity | 4786 | 4564 | 8316 |\n| Edema | 2756 | 4263 | 4321 |\n| Consolidation | 4324 | 4267 | 4972 |\n| Pneumonia | 3456 | 3474 | 4276 |\n| Atelectasis | 9512 | 6656 | 7697 |\n| Pneumothorax | 995 | 9009 | 930 |\n| Pleural Effusion | 7022 | 11913 | 6772 |\n| Pleural Other | 2042 | 2450 | 3748 |\n| Fracture | 1002 | 3659 | 929 |\n\n**(3) Dual-image Adaptation for MS-CXR-T**\n\nWe first use the Chest ImaGenome dataset to construct training and validation sets, freeze the pre-trained image encoder, and fine-tune only the classification head. During testing on MS-CXR-T, both the image encoder and the classification head fine-tuned on Chest ImaGenome are frozen, with no further parameter updates.\n\nFor each sample, the current chest X-ray and the previous chest X-ray are separately fed into the image encoder with shared weights to extract image-level features. These features are then concatenated along the feature dimension in a fixed order of \"current image, previous image\" to construct a paired-image representation. Subsequently, the paired-image representation is fed into the classification head to predict the corresponding abnormality trend category, including improvement, stability, and worsening. We have added the corresponding content to Section 4.2.1 of the revised manuscript."+ },+ "createdAt": "2026-11-14T10:15:35.895Z",+ "modifiedAt": "2026-11-14T10:15:35.895Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=VzE8NxpQpc",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/xixvhjl2my.json added
+++ b/reviews/openreview/qlgygahn3p/notes/xixvhjl2my.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "xiXVhjL2My",+ "replyTo": "tn9AJlgnRN",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Response to W1, Q5:\n**(1) Core Contributions of MedCTA and Supporting Experimental Evidence**\n\nThank you for your suggestions. We would like to clarify that TAMM is a relatively simple and coarse-grained approach that uses an LLM to identify trend changes between two adjacent visits. However, it does not construct disease trajectories and therefore cannot capture the dynamic process of disease evolution over time. In contrast, MedCTA constructs both disease-level and patient-level trajectories across multiple visits and uses an LLM to identify trend changes across the entire multi-visit sequence as supervision signals for model training. This enables the model to capture disease evolution and makes MedCTA more suitable for trend modeling in medical vision-language pre-training.\n\nTo explore MedCTA’s ability to represent longitudinal disease evolution, we conducted candidate-summary matching on the Global Trajectory Summarization multi-abnormality subset of MI-CXR [1]. Each sample contains five temporally ordered chest X-rays, a question, and five candidate summaries describing the evolution of multiple abnormalities. Data were split by patient into training, validation, and test sets (80%/10%/10%). With both image and text encoders frozen, only a projection head was trained to map features averaged across the five images into the text feature space. Training used five-class cross-entropy on image–summary cosine similarities, with the correct summary index as the target; testing ranked candidates by similarity and selected the best match. As shown in Table 1, MedCTA achieves ACC, F1, AUROC, and MRR of 63.30%, 62.03%, 88.88%, and 79.03%, respectively, outperforming TAMM (61.80%, 59.36%, 86.95%, and 77.11%). The respective ACC and MRR gains of 1.50 and 1.92 percentage points indicate improved correct summary identification and candidate ranking, providing exploratory evidence of MedCTA’s ability to represent longitudinal disease evolution. We have added this task to Section 4.2.1 of the revised manuscript.\n\nTable 1. Candidate-answer matching on the MI-CXR GTS multi-abnormality set (%).\n| Method | ACC | F1 | AUROC | MRR |\n| ------ | ----: | ----: | ----: | ----: |\n| TAMM | 61.80 | 59.36 | 86.95 | 77.11 |\n| MedCTA | 63.30 | 62.03 | 88.88 | 79.03 |\n\n[1] MI-CXR: A Benchmark for Longitudinal Reasoning over Multi-Interval Chest X-rays. ACL 2026.\n\n**(2) Additional Ablation Study on Abnormality Queries**\n\nWe added a variant without abnormality queries, which directly uses the image patch and text token representations from each visit to construct visual and textual sequences in chronological order, followed by temporal encoding.\n\nAs shown in Tables 2 and 3, MedCTA outperforms the variant without abnormality queries across all metrics on both datasets in zero-shot and linear-probing classification. These results highlight the benefits of abnormality-conditioned feature extraction for classification performance and representation quality. We have added this ablation study to Section 4.3 of the revised manuscript.\n\nTable 2. Zero-shot classification with and without abnormality queries (%)\n| Method | ACC (COVID) | F1 (COVID) | AUROC (COVID) | ACC (RSNA) | F1 (RSNA) | AUROC (RSNA) |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| w/o Abnormality Queries | 76.93 | 63.01 | 89.06 | 67.27 | 57.02 | 87.89 |\n| MedCTA | 78.02 | 63.93 | 89.62 | 68.22 | 57.91 | 88.60 |\n\nTable 3. Linear probing with and without abnormality queries (%)\n| Method | ACC (COVID) | F1 (COVID) | AUROC (COVID) | ACC (RSNA) | F1 (RSNA) | AUROC (RSNA) |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| w/o Abnormality Queries | 94.77 | 87.26 | 96.85 | 85.85 | 78.81 | 89.78 |\n| MedCTA | 95.66 | 88.48 | 96.92 | 86.05 | 79.25 | 89.82 |\n\n**(3) Additional Ablation Study on Temporal Encoders**\n\nWe replaced Mamba with GRU while keeping abnormality queries, supervision labels, training objectives, and all other experimental settings unchanged. Mamba improves the eight retrieval metrics by 0.51–2.75 percentage points (Table 4). For temporal sentence similarity classification, ACC and AUROC improve by 4.75 and 12.96 percentage points, respectively (Table 5). These results support that, under the current configuration, Mamba learns representations that are more beneficial for retrieval and temporal semantic matching. We have added details of the ablation study on temporal encoders to Section 4.3 of the revised manuscript.\n\nTable 4. Cross-modal retrieval with Mamba and GRU (%)\n\n| Retrieval Metric | GRU | MedCTA |\n| --- | ---: | ---: |\n| T→I P@1 | 78.31 | 80.24 |\n| T→I P@2 | 78.46 | 79.08 |\n| T→I P@5 | 73.21 | 75.68 |\n| T→I P@10 | 63.07 | 65.82 |\n| I→T P@1 | 67.75 | 69.13 |\n| I→T P@2 | 68.12 | 68.63 |\n| I→T P@5 | 66.20 | 67.23 |\n| I→T P@10 | 61.88 | 63.01 |\n\nTable 5. Temporal sentence similarity classification with Mamba and GRU (%)\n\n| Method | ACC | AUROC |\n| --- | ---: | ---: |\n| GRU | 90.97 | 85.16 |\n| MedCTA | 95.72 | 98.12 |"+ },+ "createdAt": "2026-11-14T10:10:41.821Z",+ "modifiedAt": "2026-11-14T10:10:41.821Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=xiXVhjL2My",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/notes/xsvpmq0foc.json added
+++ b/reviews/openreview/qlgygahn3p/notes/xsvpmq0foc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "xsVPmQ0fOc",+ "replyTo": "CB6iFCCmJB",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "# Further Response to Q1:\nThank you for the further clarification. The key distinction lies in the supervision target: visit-level interval-change labels supervise local transitions between consecutive visits, whereas MedCTA uses global dominant-trend labels to supervise the dominant direction of clinical change across the entire observation window. Thus, MedCTA considers non-monotonic disease trajectories but does not explicitly align individual local reversals.\n\n**(1) Handling non-monotonic trajectories and limitations.** MedCTA models temporally ordered visit sequences, while its global dominant-trend labels are derived from the complete longitudinal reports by considering the magnitude, persistence, and available timing information of clinical changes (Appendix E). Therefore, non-monotonic changes inform both trajectory representations and trend-label generation, but the alignment is performed at the dominant-trend semantic level rather than at each local transition. We acknowledge that a single global label cannot fully capture local reversals or their temporal details, and may be ambiguous when improvement and worsening are comparably pronounced, as illustrated in Appendix C.3.\n\n**(2) Clinical motivation and advantages.** Our objective is to capture the dominant clinical trend across an observation window, even when the observed disease trajectory is non-monotonic. For example, a multicentre clinical study found that 27.9% of 226 COVID-19 patients with radiographs at three time points exhibited worsening followed by improvement [1]. This illustrates why individual interval changes may not adequately represent the overall course. MedCTA therefore uses global dominant-trend supervision to guide abnormality-specific trajectory alignment and patient-course progression alignment, encouraging the integration of clinical changes across visits. Table 6 supports the contribution of these objectives: removing abnormality-specific or patient-course supervision reduces temporal sentence similarity classification accuracy from 95.72% to 87.47% and 90.55%, respectively.\n\nWe believe that global dominant-trend supervision and interval-level supervision address complementary aspects of longitudinal clinical change.\n\n[1] Gangi-Burton, A., et al. (2024). Temporal evolution of chest radiographic appearances in COVID-19 with clinicoradiological associations: a multicentre United Kingdom resident-led study. Clinical Radiology, 79(4), 287–295. \n\n# Further Response to Q4:\n\nThank you for acknowledging our additional clarification regarding baseline selection and result provenance. We further clarify the architecture of the TAMM baseline.\n\nTAMM uses a ViT-B/16 image encoder and a BioClinicalBERT text encoder, both initialized with MGCA weights. Beyond single-visit image-text alignment, its temporal modeling consists of two main components. First, a shared trend classifier supervises feature differences between adjacent visits to predict temporal trends. Second, an explanation-text-guided vision-language fusion module performs bidirectional prediction of visual local features across adjacent visits and imposes a feature reconstruction consistency constraint.\n\nMedCTA also adopts MGCA initialization but further introduces abnormality-specific queries and a Mamba-based temporal encoder to explicitly construct disease-specific trajectories and an overall patient-level trajectory, supervised by the dominant trend across the entire observation window. Therefore, the differences between the two methods lie in both the construction of temporal representations and the granularity of trend supervision."+ },+ "createdAt": "2026-11-17T13:00:59.544Z",+ "modifiedAt": "2026-11-17T13:00:59.544Z",+ "url": "https://openreview.net/forum?id=QLgyGAhN3P¬eId=xsVPmQ0fOc",+ "license": "CC-BY-4.0"+}
reviews/openreview/qlgygahn3p/submission.json added
+++ b/reviews/openreview/qlgygahn3p/submission.json@@ -0,0 +1,17 @@+{+ "schema": "submission/1",+ "id": "QLgyGAhN3P",+ "venue": {+ "id": "ICLR.cc/2027/Conference",+ "name": "ICLR 2027",+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference"+ },+ "number": 24892,+ "keywords": [+ "Medical Vision-Language Pre-training",+ "Clinical Trajectory Modeling",+ "Temporal Representation Learning"+ ],+ "url": "https://openreview.net/forum?id=QLgyGAhN3P",+ "license": "CC-BY-4.0"+}
versions/v_n2rtmwtb.json added
+++ b/versions/v_n2rtmwtb.json@@ -0,0 +1,21 @@+{+ "date": "2026-09-16",+ "kind": "submitted",+ "label": "ICLR 2027",+ "submissions": [+ {+ "venue": "ICLR 2027",+ "status": "under_review",+ "number": 24892,+ "url": "https://openreview.net/forum?id=QLgyGAhN3P",+ "reviews": "openreview/qlgygahn3p",+ "evidence": [+ "https://openreview.net/forum?id=QLgyGAhN3P"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=QLgyGAhN3P",+ "evidence": [+ "https://openreview.net/forum?id=QLgyGAhN3P"+ ]+}