Update ICLR 2027 submission TtT1oJyvVa: 1 note
@openreview[bot] · 2026-11-24 15:41 UTC · 31e00ac74e34 ·
reviews/openreview/ttt1ojyvva/notes/wpuhcip4lh.json modified
+++ b/reviews/openreview/ttt1ojyvva/notes/wpuhcip4lh.json@@ -11,14 +11,14 @@"informativeness": 2,"soundness": 2,"critical_strengths": "1. Practically relevant problem. This paper addresses three cases together (CEV, SIV, and HCI) and also evaluates against the real data while most prior works are limited to synthetic perturbation. Aligning an online image space Retinex-style estimate with a shared Gaussian illumination field is interesting.\n\n2. Proposes real-world dataset. The 9 scene dataset covering CEV, SIV, and HCI under realistic camera response, flash fall-off, and saturation provides evaluation in real-world scenarios. Prior works seem to rely mostly on synthetic perturbations.","critical_weaknesses": "1. The proposed framework is an engineering tweak. It is mostly integration of different components such as Retinex-style decomposition (also addressed in works such as L^2DGS, LL-Gaussian), and multiplicative illumination (used in L^2DGS). Though the paper claims to couple 2D and 3D, where image-space network estimates illumination and reflectance, they are used as a supervision of output from 3D path (for example, L_{2D} is estimated in 2D which which is used to supervise L_{adapt} estimated from 3D information), as clearly highlighted in Fig. 2. \n\n2. The biggest improvement in the paper is on real HCI, about 3.4 dB over the next best method. But it is not entirely convincing that this comes from the coupled 2D-3D design. Two local, hand-crafted components seem to account for gains of a similar size. Removing ILEC costs 2.9 dB on HCI (Table 4) while being nearly neutral on CEV and SIV. The only ablation of the adaptive curve loss (Table 5) also shows a 2.9 dB drop on HCI, but that number is for the 2D branch's own output, not the full model. Both act locally, the curve loss pushes each region toward mid-tone, and ILEC rescales brightness per region in each training image. The Tone-Matched 3DGS baseline only applies one global gain per image, so it doesn't really address this. The ``No Image-Space Decomp.'' ablation removes the coupling and the 2D priors together, so it can't separate them either. Without the full model trained without the curve loss (and ideally without both the curve loss and ILEC), it's hard to tell how much of the HCI result is due to the proposed coupling.\n\n3. The objective is a weighted sum of 12 losses, plus a staged training schedule, but there is no sensitivity analysis on the weights (at least, I could not find it). This matters more than usual here. With several competing objectives on an ill-posed decomposition, the weights effectively decide which split between base color and illumination the method ends up with. Many weight settings can reach a similarly low total loss with quite different decompositions. Several terms are also never ablated on their own. The alignment and recombination losses are the clearest case. They are the core of the claimed coupling, yet they are only removed together with the whole 2D branch. They also seem to ask for the same thing. Since $R_{2D} = I \\oslash (L_{2D}+\\epsilon)$, the recombination term compares $I \\odot L_{adapt} \\oslash L_{2D}$ with $I$, which is satisfied exactly when $L_{adapt} \\approx L_{2D}$. That is the same condition as the alignment loss, just measured as a relative error weighted by image intensity rather than as an absolute difference. The two may therefore be largely redundant, and an ablation keeping one and removing the other is needed to see whether both are necessary. Similarly, the image-space priors are ablated only on the 2D output, not on the final reconstruction. So it is difficult to say which parts actually matter for the final result or how sensitive the method is to these choices. Also other ablations are hard to interpret, which should be discussed explicitly in detail. \n\n4. The equations in Sec. 3.1 - 3.3 need proper motivation, intuition and explanation. The authors should mention the dimension and meaning of each quantity, and how they are estimated. For example, estimation of normal, quantities/notations involved in Eq. 2-5, and motivation/intuition of Eq. 4, estimation of r(t) etc. While some of these are included in the appendix, it is hard to follow the notations and equations in their current form.\n\n5. The paper does not provide multiple seeds experiments, variance or confidence interval. 3.41 dB HCI claim is based on just 2 scenes. Also, there is a degradation of ~2.7 dB on CEV when removing normals or view-directions. The same removal has almost no effect on SIV and HCI (and no view direction is slightly better on SIV). This is not explained. \n\n6. There are multiple missing comparisons with methods such as LITA-GS, LL-Gaussian, Gaussian-DK, HDR-GS, and SWAG.",- "questions_for_authors": "1. Following Weakness 2, report the full EvenSplat model trained without the adaptive curve loss on the real HCI scenes (ideally also with ILEC removed). This would help show how much of the HCI gain comes from the coupling itself.\n\n2. Following Weakness 3, report results with only the alignment loss and with only the recombination loss? Given that both effectively enforce $L_{adapt} \\approx L_{2D}$, it would help to know whether both are needed.\n\n3. Compare against other methods: LITA-GS, LL-Gaussian, Gaussian-DK, HDR-GS, SWAG.\n\n4. Though each scene has a separate evenly lit capture, the dataset size is limited (9 scenes) with only 2 HCI and 3 CEV. The subjects are mostly small objects (logs, a robot, benches, rocks, a cart). That is not rich or diverse, and it does not match the motivation about large indoor spaces with mixed, locally varying lighting. Furthermore, HCI and SIV are both made with one flash/under-exposure setting. There are no windows, mixed color temperatures, multiple light sources, specular materials or moving shadows.\n\n5. Why do \"No Normals\" and \"No View Directions\" result in degradation of ~2.7 dB on CEV but almost none on SIV or HCI?\n\n6. Table 5 shows that allowing colored illumination can improve some metrics. Have the authors explored a lightly constrained colored variant more thoroughly on the real HCI/SIV scenes?\n\n7. The base color keeps SH up to degree 3, with the higher-order coefficients only penalized. Have you tried using only the DC term (SH degree 0)? That removes view-dependent effects from the base color by construction. It would be useful to see this compared with the current setup, including on the cross-lighting consistency test.\n\n8. The paper does now show any failure cases. What would happen, for example, in the presence of intrinsically dark or bright materials? \n\n9. Clarify what ``Image-Space Decomp. Only'' in Table 4 is exactly.\n\n\n**Minor**\n1. Figs. 11–13 do not seem to have been updated. They label one column “Retinex-GS” (which is presumably an earlier name of the method) and another “3DGS+CHROMA”, which is not among the listed baselines and appears only in appendix Table 11, not in the main comparisons.\n\n2. Equation references in the text appear as “Eq. equation N” throughout.\n\n3. The ϵ in R2D = I ⊘ (L2D + ϵ) is unnecessary since L2D is already bounded below by 0.05.",+ "questions_for_authors": "1. Following Weakness 2, report the full EvenSplat model trained without the adaptive curve loss on the real HCI scenes (ideally also with ILEC removed). This would help show how much of the HCI gain comes from the coupling itself.\n\n2. Following Weakness 3, report results with only the alignment loss and with only the recombination loss? Given that both effectively enforce $L_{adapt} \\approx L_{2D}$, it would help to know whether both are needed.\n\n3. Compare against other methods: LITA-GS, LL-Gaussian, Gaussian-DK, HDR-GS, SWAG.\n\n4. Though each scene has a separate evenly lit capture, the dataset size is limited (9 scenes) with only 2 HCI and 3 CEV. The subjects are mostly small objects (logs, a robot, benches, rocks, a cart). That is not rich or diverse, and it does not match the motivation about large indoor spaces with mixed, locally varying lighting. Furthermore, HCI and SIV are both made with one flash/under-exposure setting. There are no windows, mixed color temperatures, multiple light sources, specular materials or moving shadows.\n\n5. Why do \"No Normals\" and \"No View Directions\" result in degradation of ~2.7 dB on CEV but almost none on SIV or HCI?\n\n6. Table 5 shows that allowing colored illumination can improve some metrics. Have the authors explored a lightly constrained colored variant more thoroughly on the real HCI/SIV scenes?\n\n7. The base color keeps SH up to degree 3, with the higher-order coefficients only penalized. Have you tried using only the DC term (SH degree 0)? That removes view-dependent effects from the base color by construction. It would be useful to see this compared with the current setup, including on the cross-lighting consistency test.\n\n8. The paper does now show any failure cases. What would happen, for example, in the presence of intrinsically dark or bright materials? \n\n9. Clarify what ``Image-Space Decomp. Only'' in Table 4 is exactly.\n\n\n**Minor**\n1. Figs. 11–13 do not seem to have been updated. They label one column “Retinex-GS” (which is presumably an earlier name of the method) and another “3DGS+CHROMA”, which is not among the listed baselines and appears only in appendix Table 11, not in the main comparisons.\n\n2. Equation references in the text appear as “Eq. equation N” throughout.\n\n3. The ϵ in R2D = I ⊘ (L2D + ϵ) is unnecessary since L2D is already bounded below by 0.05.\n\n\n\nFinal comments: The detailed responses from the authors' have helped resolve most of my concerns. Hence, I am raising my score.","flag_for_ethics_review": "No","rating": 3,"confidence": 3},"createdAt": "2026-10-19T09:50:56.050Z",- "modifiedAt": "2026-11-22T17:22:46.602Z",+ "modifiedAt": "2026-11-23T06:16:22.986Z","url": "https://openreview.net/forum?id=TtT1oJyvVa¬eId=WpuHCip4lH","license": "CC-BY-4.0"}