Import ICLR 2027 submission mYjJFlOKNn: 3 notes
@openreview[bot] · 2026-11-22 21:39 UTC · c91db84b8f1d ·
reviews/openreview/myjjfloknn/forms.json added
+++ b/reviews/openreview/myjjfloknn/forms.json@@ -0,0 +1,183 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "additional_comments_on_reviewer_discussion",+ "label": "Reviewer discussion",+ "type": "text"+ },+ {+ "key": "recommendation",+ "label": "Recommendation",+ "type": "choice"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "soundness",+ "presentation",+ "informativeness"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "soundness",+ "label": "Soundness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "presentation",+ "label": "Presentation",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "informativeness",+ "label": "Informativeness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "paper_summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "critical_strengths",+ "label": "Strengths",+ "type": "text"+ },+ {+ "key": "critical_weaknesses",+ "label": "Weaknesses",+ "type": "text"+ },+ {+ "key": "questions_for_authors",+ "label": "Questions for the authors",+ "type": "text"+ },+ {+ "key": "flag_for_ethics_review",+ "label": "Flag for ethics review",+ "type": "choice",+ "omitWhen": [+ "No",+ "No ethics review needed."+ ]+ },+ {+ "key": "details_of_ethics_concerns",+ "label": "Ethics concerns",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/myjjfloknn/notes/k0ncitgie6.json added
+++ b/reviews/openreview/myjjfloknn/notes/k0ncitgie6.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "K0nciTgie6",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer oupL",+ "content": {+ "paper_summary": "This work presents Dist-RRG, a distributional framework for longitudinal chest X-ray report generation that models per-visit latent representations, between-visit changes, and prior reports as diagonal Gaussians rather than pointwise feature vectors. The method builds on a frozen per-visit variational encoder (DiA-gnostic VLVAE) and introduces three temporal modules in the following stage. Experiments on Longitudinal MIMIC-CXR compare against matched longitudinal baselines and examine the propagated variance through calibration, selective prediction, and inference-time interventions.",+ "presentation": 3,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "1. The approach is intuitive and coherent, and provides an explicit mechanism for retaining information that point-wise temporal representations do not separately expose. \n\n2. The reported report-generation gains have meaningful empirical support and RadGraph additionally provides evidence beyond the CheXbert labeler used for auxiliary supervision.",+ "critical_weaknesses": "1. Currently the reported calibration intervention appears to be inconsistent with the stated computational graph. Section 4.4 describes an intervention that modifies only the log-variances entering the decoder’s FiLM layer while holding the checkpoint, aggregated means, attention weights, and inputs fixed. However, the progression head in Eq. (12) receives only the current shared mean, aggregated prior mean, and aggregated change mean. Section 4.1 explicitly states that ECE is computed from this head’s probabilities. Under the described computation, these probabilities (and ECE) should remain unchanged. Nevertheless, Tables 9–10 report ECE increasing from 0.041 to 0.056 after shuffling and to 0.061 after clamping. Could the authors clarify how this FiLM-only intervention changes the progression-head probabilities and ECE? Does the head receive additional variance-dependent inputs omitted from Eq. (12), or is ECE computed from a different output than stated?\n\n2. It seems that the incremental benefits of several auxiliary components remain unclear. Removing RFF or the surrogate prior yields paired confidence intervals that include zero, leaving their contributions unresolved. I am also unsure how much HSIC helps. Both the dependence estimate and kernel bandwidth are based on batches of just four samples, but the paper does not show what happens when HSIC is removed from the full model or when larger batches are used.",+ "questions_for_authors": "See weakness section.",+ "flag_for_ethics_review": "No",+ "rating": 3,+ "confidence": 2+ },+ "createdAt": "2026-10-22T00:39:19.875Z",+ "modifiedAt": "2026-11-17T07:37:31.946Z",+ "url": "https://openreview.net/forum?id=mYjJFlOKNn¬eId=K0nciTgie6",+ "license": "CC-BY-4.0"+}
reviews/openreview/myjjfloknn/notes/ukiugwgdz5.json added
+++ b/reviews/openreview/myjjfloknn/notes/ukiugwgdz5.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "UKiUGWgDZ5",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer YfMM",+ "content": {+ "paper_summary": "This paper addresses an important problem in longitudinal radiology report generation: how to represent changes between medical imaging visits while preserving uncertainty associated with individual observations and disagreements among historical reports.\nThe authors propose Dist-RRG, a distributional framework in which imaging features, clinical indications, temporal differences, and prior reports are represented using diagonal Gaussian distributions.\nThe paper presents substantial theoretical and experimental material, including Gaussian geometry, an exact variance-preservation result, matched baseline reruns, component ablations, calibration experiments, selective prediction, and a direct intervention on the variance pathway.",+ "presentation": 3,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "The paper has several clear strengths. Its mathematical treatment of Gaussian aggregation is coherent, its comparison methodology explicitly separates published results from matched reruns, and the variance-shuffling intervention provides evidence that patient-specific variance features contribute to prediction performance.\n\nThe paper is technically coherent, presents a well-motivated distributional framework, provides useful analytical properties, conducts matched baseline comparisons, and evaluates the variance pathway more carefully than a standard accuracy-only report-generation study. The authors also acknowledge limitations in the geometric interpretation, automated supervision, and clinical meaning of variance.",+ "critical_weaknesses": "The frozen variational encoder produces learned diagonal Gaussian parameters, but their variances are not necessarily calibrated uncertainties about radiographic findings.\nThe paper's experiments demonstrate association with prediction difficulty and usefulness as conditioning features, rather than validated epistemic or aleatoric uncertainty.\n\nThe title emphasizes statistical manifolds, but the deployed DPG attention uses a trajectory-dependent reweighting of a Gaussian dissimilarity rather than a single globally defined Fisher–Rao distance.\nThe authors acknowledge this in Sections 3.4 and Appendix B, which is good. The distinction should also be conveyed in the abstract.\n\nThe sentence:\nMost sentences in a chest radiograph report are comparative.\nis stronger than necessary and is not established by the paper's dataset analysis.\n\nThe reported ECE is calculated from the auxiliary progression-classification head, not directly from the probability that a generated sentence or clinical finding is correct.\nThe abstract should call it progression-head calibration rather than leaving readers to infer that it measures calibration of generated reports.\n\nThe architecture figure combines Gaussian encoders, report history, distributional differences, attention, mixture aggregation, FiLM, decoder fusion, and the training objective into a compact diagram.\nThe font sizes are small, making it difficult to distinguish the essential mathematical contributions.\n\nThe paper correctly warns that published scores and matched scores use potentially different evaluation conventions. However, presenting all CE-F1 numbers in the same columns invites direct comparison.\nFor example, TIM reports 0.511 CE-F1 under its original protocol, whereas Dist-RRG reports 0.509 under the matched P1 setting. These numbers cannot establish which model is better.\n\nThe P2 model obtains New F1 of 0.412 and Resolved F1 of 0.730 (Table 3, page 9). This asymmetry matters because detecting new pathology is especially relevant to longitudinal reporting.\n\nAppendix Figure 3 (page 23) provides an example in which using five priors avoids an unsupported assertion of change. The example illustrates the value of additional historical context but does not isolate the effect of variance propagation.\n\nThe central contribution is spread across several interacting architectural components, which sometimes makes it difficult to identify what is essential to the method.\nDDM, DPG, MMDA, RTAM, random-Fourier correction, FiLM, the progression head, the KL penalty, and HSIC regularization all enter the final model. The cumulative presentation is coherent, but the relative scientific importance of these components is not immediately clear.\nAdditionally, the strongest uncertainty experiments are located after the generation benchmark results, despite uncertainty preservation being the paper's main motivating claim.\n\nEquation (6) uses the law of total variance:\n\\hat{\\sigma}^2=\\sum_t \\alpha_t\\sigma_t^2+\\sum_t\\alpha_t(\\mu_t-\\hat{\\mu})^2.\nThe associated forward-KL characterization is a known property of exponential-family projection.\nThe authors acknowledge this, but the novelty should be attributed to the application and end-to-end integration rather than the projection itself.\n\nProposition 1 connects the proposed Gaussian dissimilarity to a local metric. The Fisher–Rao match requires \\(\\kappa=4\\), whereas experiments use \\(\\kappa=1\\).\nAlthough the Euclidean-attention ablation supports the usefulness of distribution-aware scoring, it does not determine whether the proposed geometric formulation is better than simpler variance-normalized distances.\n\nThe model includes additional attention, FiLM transformations, latent distributions, and auxiliary losses. Consequently, performance improvement may partly arise from the larger or more expressive temporal pathway.",+ "questions_for_authors": "Sections 3.6, 4.4, and 5; Appendix Tables 9–12.\nThe paper demonstrates that aggregated latent variance contains useful patient-specific information.\nFor instance, shuffling the variance vectors decreases New F1 from 0.412 to 0.389 and increases ECE from 0.041 to 0.056.\nHowever, this intervention modifies only the log-variance input to FiLM while preserving the aggregated means and attention weights. It shows that the decoder uses these variance-conditioned features, but does not demonstrate that their values faithfully represent clinical uncertainty.\nA learned latent variance could encode image complexity, disease prevalence, observation quality, or other patient characteristics without being a well-calibrated uncertainty estimate.\n\nSections 3.7 and 4.1–4.5; Appendix E.\nThe progression-consistency head is supervised using CheXbert-derived transition labels, and CheXbert is also used to calculate clinical efficacy and progression-transition metrics.\nThe paper appropriately includes RadGraph-F1 as an additional metric. This reduces dependence on a single extraction system but does not eliminate the problem that both automated metrics judge generated reports against reference-report text rather than independently adjudicated clinical facts.\nA particularly important detail appears in Appendix E: CheXbert's Negative, Uncertain, and Blank categories are all mapped to absence.\nConsequently:\nUncertain → Positive is classified as New.\nPositive → Uncertain is classified as Resolved.\nNegative → Uncertain is classified as Stable.\nThese transitions can represent changes in reporting certainty rather than genuine clinical disease progression.\n\nSections 4.1–4.3; Tables 1 and 2.\nThe strongest matched longitudinal baseline is Diff-RRG, with CE-F1 0.482 versus 0.509 for Dist-RRG under P1.\nThe paired interval for the improvement is [0.012, 0.041], excluding zero.\nHowever, the baseline reruns have only one training seed, and they do not receive equivalent auxiliary CheXbert progression supervision. This makes it difficult to attribute the difference specifically to distributional change modeling.\nFurthermore, the concurrent TIM model reports CE-F1 0.511 under its own protocol, but is not evaluated using the matched procedure. The authors correctly avoid presenting this as a comparable result.\n\nSection 3.2; Appendix B; Table 8.\nThe distributional difference assumes independent visit-level Gaussian representations:\n\\mathrm{Var}(Z_T-Z_t)=\\sigma_T^2+\\sigma_t^2.\nHowever, longitudinal observations of the same patient are correlated.\nThe more general expression is\n\\mathrm{Var}(Z_T-Z_t)=\\sigma_T^2+\\sigma_t^2-2\\mathrm{Cov}(Z_T,Z_t).\nThe paper recognizes this and provides a sensitivity sweep. In Table 8, increasing assumed cross-visit correlation from 0 to 0.75 decreases CE-F1 from 0.516 to 0.504.\nThis establishes some sensitivity but does not show whether the independence approximation is realistic.\nMoreover, overstating variance under positive covariance is not necessarily conservative with respect to downstream report decisions.\n\nSection 3.7; Appendix D, Equation (12).\nUnder P2, the temporal representation aggregates up to five prior examinations. However, the progression-consistency target is defined relative to the most recent prior.\nThis creates a potential mismatch: the auxiliary head receives an attention-weighted summary of multiple visits but must predict a label referring to a specific pair of visits.\nThe authors acknowledge this design choice, but do not experimentally establish whether it is beneficial.\n\nSection 5; Appendices H and I.\nAll reported quantitative evaluations use Longitudinal MIMIC-CXR. The test split contains 266 patients and 2,058 longitudinal targets.\nThe manuscript includes a proposed reader-study protocol, but no radiologist evaluation has been conducted.\nThis limits conclusions about the clinical correctness and safety of generated comparative statements, particularly unsupported claims of new findings or disease resolution.",+ "flag_for_ethics_review": "No",+ "rating": 3,+ "confidence": 3+ },+ "createdAt": "2026-10-16T18:23:21.352Z",+ "modifiedAt": "2026-11-06T12:26:01.440Z",+ "url": "https://openreview.net/forum?id=mYjJFlOKNn¬eId=UKiUGWgDZ5",+ "license": "CC-BY-4.0"+}
reviews/openreview/myjjfloknn/notes/vwjgja3vvg.json added
+++ b/reviews/openreview/myjjfloknn/notes/vwjgja3vvg.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "VwjgJa3VVg",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Qdjd",+ "content": {+ "paper_summary": "The paper proposes uncertainty quantification framework for multi visit longitudinal for chest radiography classification. The proposed pipeline composes several stages such as fixed report/image encoders, where each patient visit is modeled as difference of independent diagonal gaussians, attention based aggregation weights. Experiments are conducted on MIMIC-CXR dataset and demonstrates better performance on standard metrics against several baselines.",+ "presentation": 1,+ "informativeness": 1,+ "soundness": 2,+ "critical_strengths": "* The experiments show good empirical performance compared to several other methods and the ablations seem to demonstrate the additive gain of each component\n* The multi visit/variable history setting appears novel and understudied",+ "critical_weaknesses": "* No clinical validation or reader study is conducted. The treatment and evaluation of uncertainty is shallow and unconvincing.\n* The framework is very complex and overly specific to this medical reporting application and only one dataset/task is considered. It remains unclear what takeaways or new knowledge is created from the paper.",+ "questions_for_authors": "* What are the generalizable insights of findings outside of longitudinal radiology reporting? \n* How clinically meaningful is the uncertainty? \n* How does interrater calibration affect uncertainty? different visits will be reported by different clinicians with different levels of uncertainty. \n* why assume gaussian distribution? why choose Bhattacharyya distance? what motivates these design choices\n* Which is the most technically novel components of the framework and how do they compare to alternative in terms of performance and tradeoffs?\n* how should the loss component weights be set for a new dataset or task? what affect do they have on the optimization?",+ "flag_for_ethics_review": "No",+ "rating": 2,+ "confidence": 3+ },+ "createdAt": "2026-10-19T02:27:18.617Z",+ "modifiedAt": "2026-11-18T08:33:49.258Z",+ "url": "https://openreview.net/forum?id=mYjJFlOKNn¬eId=VwjgJa3VVg",+ "license": "CC-BY-4.0"+}
reviews/openreview/myjjfloknn/submission.json added
+++ b/reviews/openreview/myjjfloknn/submission.json@@ -0,0 +1,22 @@+{+ "schema": "submission/1",+ "id": "mYjJFlOKNn",+ "venue": {+ "id": "ICLR.cc/2027/Conference",+ "name": "ICLR 2027",+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference"+ },+ "number": 27080,+ "keywords": [+ "longitudinal radiology report generation",+ "uncertainty quantification",+ "calibration",+ "selective prediction",+ "vision-language models",+ "moment matching",+ "information geometry",+ "medical imaging"+ ],+ "url": "https://openreview.net/forum?id=mYjJFlOKNn",+ "license": "CC-BY-4.0"+}
versions/v_y34a628d.json modified
+++ b/versions/v_y34a628d.json@@ -1,7 +1,20 @@{+ "date": "2026-09-16","kind": "submitted","label": "ICLR 2027 (under review)",+ "submissions": [+ {+ "venue": "ICLR 2027",+ "status": "under_review",+ "number": 27080,+ "url": "https://openreview.net/forum?id=mYjJFlOKNn",+ "reviews": "openreview/myjjfloknn",+ "evidence": [+ "https://openreview.net/forum?id=mYjJFlOKNn"+ ]+ }+ ],"url": "https://openreview.net/forum?id=mYjJFlOKNn","pdf": {"source": "https://openreview.net/forum?id=mYjJFlOKNn","license": "CC-BY-4.0"