Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views
Update ICLR 2027 submission Bu0OQpYX67: 1 note
@openreview[bot] · 2026-11-24 15:36 UTC · e9e74fdcb2db ·
reviews/openreview/bu0oqpyx67/notes/5q8ujzztix.json modified
+++ b/reviews/openreview/bu0oqpyx67/notes/5q8ujzztix.json@@ -13,12 +13,12 @@"critical_strengths": "1. Explicit and anatomically structured vessel representation.\n\nDirectly predicting B-spline centerlines and dense radius profiles is a meaningful design choice. Unlike voxel-based methods that require additional centerline extraction, the proposed representation naturally preserves within-branch connectivity and provides geometric information useful for downstream applications. The experimental results demonstrate substantial improvements in structural connectivity. It addresses a practical limitation of existing reconstruction methods and reduces the need for potentially error-prone post-processing.\n\n2. Efficient reconstruction with effective projection-guided refinement.\n\nThe coarse-to-fine framework achieves competitive reconstruction accuracy while requiring only 121 ms per case. The ablation studies show that the B-spline representation and projection-guided refinement substantially improve reconstruction quality. It also demonstrates that the proposed approach can achieve a reasonable balance between accuracy and computational efficiency, making it potentially suitable for time-sensitive applications.","critical_weaknesses": "1. Limited validation on realistic angiographic data.\n\nThe quantitative evaluation relies entirely on synthetic projections generated from CT-derived coronary anatomy. These projections do not fully capture the challenges of clinical angiography, particularly cardiac motion between acquisitions, imperfect segmentation, and calibration errors. Although qualitative results on real angiograms are included, they are insufficient to demonstrate reliable generalization. This is a major concern because the method's practical value depends on its robustness to real-world imaging conditions, and the current evidence does not establish whether the reported improvements can be maintained in clinical settings.\n\n2. Reconstruction accuracy and clinical relevance remain insufficiently demonstrated.\n\nDespite strong connectivity results, the method does not consistently outperform existing approaches in reconstruction accuracy. For example, in the two-view LCA experiments, DeepCA achieves higher Dice and clDice scores (56.56% and 71.20%) than the proposed method (49.45% and 61.30%). Furthermore, although direct radius prediction is a key contribution, the paper does not provide a quantitative evaluation of radius reconstruction accuracy or stenosis-related geometric measurements. This weakness is consequential because improved connectivity alone does not necessarily indicate more accurate vascular reconstruction, and the lack of quantitative radius evaluation makes it difficult to assess the method's advantages for downstream applications such as quantitative coronary analysis.","questions_for_authors": "1. Can the authors provide a quantitative evaluation on real angiographic data, or at least investigate robustness to realistic inter-view cardiac motion, segmentation errors, and projection calibration errors? Such experiments would help establish whether the improvements observed on synthetic data transfer to clinical conditions.\n\n2. Can the authors evaluate centerline and radius reconstruction accuracy separately, particularly for small side branches and regions with vessel narrowing? Since explicit geometric reconstruction is a primary motivation of the proposed method, these measurements would help clarify its advantages over existing volumetric approaches.\n\n3. The proposed method achieves substantially better connectivity but lower Dice and clDice than DeepCA on two-view LCA reconstruction. Can the authors explain this trade-off and clarify whether the connectivity advantage comes primarily from the imposed parametric representation rather than more accurate recovery of the underlying 3D anatomy?","flag_for_ethics_review": "No",- "rating": 2,+ "rating": 3,"confidence": 4},"createdAt": "2026-10-22T11:59:22.430Z",- "modifiedAt": "2026-11-06T12:26:15.539Z",+ "modifiedAt": "2026-11-24T06:02:29.433Z","url": "https://openreview.net/forum?id=Bu0OQpYX67¬eId=5q8UjzZTIx","license": "CC-BY-4.0"}