potentialpaper

Quantum-Assisted Prototype-Guided Refinement for Robust Medical Image Classification under Label Noise

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 19:35 UTC · dd74163f353b ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "lTwRQCzTOz"
- }
- ],
- "title": "Quantum-Assisted Prototype-Guided Refinement for Robust Medical Image Classification under Label Noise",
- "authors": [],
- "abstract": "Labels of medical images are often corrupted by annotation errors, diagnostic ambiguity, and uncertainty in report-derived findings, and deep networks trained on such labels memorize the errors. Prototype-based label correction can repair corrupted supervision, but only in an embedding where classes are separated and concentrated; otherwise erroneous assignments contaminate the prototypes and reinforce the errors they are meant to correct. We propose \\textbf{HQProNet}, which couples trusted-anchor prototype refinement with a compact variational quantum circuit (VQC) that defines the matching geometry. Prototypes are initialized from a small audited anchor set, temperature-scaled cosine similarities yield refined soft targets, and confidence-gated moving-average updates adapt the prototypes during training. The VQC maps a unit-norm 256-dimensional amplitude vector to eight Pauli-$Z$ expectations, each a trainable quadratic form with eigenvalues in $[-1,1]$, using 120 rotation angles. A conditional analysis shows that prototype matching recovers the clean label when the number of trusted anchors, the within-class covariance, and the cosine margin jointly satisfy an explicit condition. On six MedMNISTv2 datasets under symmetric and pairwise corruption, HQProNet attains the best macro-F1 in 34 of 36 conditions, and on CheXpert it is best on all six metrics under two uncertainty policies. With the prototype mechanism fixed, replacing the VQC by linear, nonlinear, or parameter-matched classical projectors lowers macro-F1 by at least 2.2 points in every setting and reduces the cosine margin and refinement accuracy: prototype refinement is the primary source of robustness, and the VQC supplies the most favorable geometry among the projectors tested.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "b838e620-d604-4c8b-acea-7e81f25ff7e3"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "Quantum-Assisted Prototype-Guided Refinement for Robust Medical Image Classification under Label Noise",
+ "authors": [],
+ "abstract": "Labels of medical images are often corrupted by annotation errors, diagnostic ambiguity, and uncertainty in report-derived findings, and deep networks trained on such labels memorize the errors. Prototype-based label correction can repair corrupted supervision, but only in an embedding where classes are separated and concentrated; otherwise erroneous assignments contaminate the prototypes and reinforce the errors they are meant to correct. We propose \\textbf{HQProNet}, which couples trusted-anchor prototype refinement with a compact variational quantum circuit (VQC) that defines the matching geometry. Prototypes are initialized from a small audited anchor set, temperature-scaled cosine similarities yield refined soft targets, and confidence-gated moving-average updates adapt the prototypes during training. The VQC maps a unit-norm 256-dimensional amplitude vector to eight Pauli-$Z$ expectations, each a trainable quadratic form with eigenvalues in $[-1,1]$, using 120 rotation angles. A conditional analysis shows that prototype matching recovers the clean label when the number of trusted anchors, the within-class covariance, and the cosine margin jointly satisfy an explicit condition. On six MedMNISTv2 datasets under symmetric and pairwise corruption, HQProNet attains the best macro-F1 in 34 of 36 conditions, and on CheXpert it is best on all six metrics under two uncertainty policies. With the prototype mechanism fixed, replacing the VQC by linear, nonlinear, or parameter-matched classical projectors lowers macro-F1 by at least 2.2 points in every setting and reduces the cosine margin and refinement accuracy: prototype refinement is the primary source of robustness, and the VQC supplies the most favorable geometry among the projectors tested.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}