potentialpaper

Knowing When Not to Segment: Label-Free Adaptation in Free-Hand Ultrasound

Update ICLR 2027 submission xRChOCRUJY: 1 note

@openreview[bot] · 2026-11-24 17:22 UTC · e068a65f2eda ·

Evidence

reviews/openreview/xrchocrujy/notes/ve3kwbncg9.json modified

+++ b/reviews/openreview/xrchocrujy/notes/ve3kwbncg9.json
@@ -13,12 +13,12 @@
"critical_strengths": "**Critical strength**: Relevant & Underexplored problem. **Why it is consequential to my overall assessment**: The identification of failure modes in this area is important: models that are trained on imbalanced data containing relevant structures but also frames where they are absent is an often occurring property in real-world data. Thus, handling this scenario is clearly motivated and practical, as motivated with the application example of guiding users without any medical expertise to use handheld wireless ultrasound correctly.",
"critical_weaknesses": "**Critical weakness**: The contributions are very limited due to the very specific application area and missing possibility for generalization. **Why it is consequential to my overall assessment**: The manuscript presents hand-crafted anatomical rules which are only designed for the neck anatomy in hand-held ultrasound and transfer is only tested to SegThy. Thus, it is not shown that the presented methodology can be used on a different anatomy or in other medical contexts, which narrows the potential impact to the domain of hand-held ultrasound of the neck area, which itself is rather limited. Coupled with the results of persist and fit beating baselines with only a very slim margin and a non-significant gain when it comes to the comparison of source models, the contribution is limited further. A very related baseline [A] (only mentioned in appendix, not in realted work) is a source-free, backprop-free TTA method for ultrasound segmentation, which was also evaluated on thyroid data, which would match protocol for the systematic analysis in main result Tables 3 and 5. Although cited, it is still not compared against. Minor, but related work such as [B] should be cited in related work (in context of anatomical-priors, line 141).\n\n**Critical weakness**: Limited reliability of some claims and suboptimal structure of the manuscript. **Why it is consequential to my overall assessment**: The experiments have been tested on a small unseen held-out test set of 58 samples, which is extremely small to reliably assess the efficacy of the presented method and compare it to baselines. What limits the contributions further is the very limited overall dataset size of 232 annotated ultrasound frames. The manuscript further claims an improved evaluation metric as contribution (i.e., evaluation scheme where standard evaluation fails), yet, a clear comparison is only provided in the supplemental material (Table 5, 6), and is not experimentally substantiated in the main paper. Similarly, experimental analysis on the SegThy dataset, which is claimed as main contribution (line 98, experiments on \"second target domain\") are merely supplied in the appendix, which for substantiating a contribution should be discussed prominently in the main paper. In related work (section 2), the manuscript references future sections including results from the evaluation section (section 5) which interrupts the reading flow, showcasing that the overall structure of the manuscript could be improved (cf. lines 138, 141 and 149). \n\n\nReferences:\n\n[A] Wang, W., Zhou, J., Zhang, C., Xing, W., Fan, S., & Qu, X. (2026). Prototype bank‐driven test‐time adaptation for medical ultrasound image segmentation. Medical Physics, 53(1), e70280.\n\n[B] Zhang, R., Lu, W., Guan, C., Gao, J., Wei, X., & Li, X. (2024, October). Shan: Shape guided network for thyroid nodule ultrasound cross-domain segmentation. In International Conference on Medical Image Computing and Computer-Assisted Intervention (pp. 732-741). Cham: Springer Nature Switzerland.",
"questions_for_authors": "**Q1 Missing baselines**\nPrototype-bank TTA for ultrasound [A] is cited but listed as not run. Could you explain why these are excluded from the experiments?\n\n**Q2 Effort for possible generalization**\nHow hard would it be to define similar anatomical constraints for anatomical areas, in which target structures are less rigidly arranged than in the neck?\n\n**Q3 Exact target use case**\nThe manuscript motivates the work with bringing AI-guided ultrascan to users without any medical expertise in community settings. I am interested in what exact clinical use case is addressed? And how well do sweeps acquired by the research team represent scans performed by inexperienced users?",
"flag_for_ethics_review": "No",
- "rating": 1,
+ "rating": 2,
"confidence": 3
},
"createdAt": "2026-10-19T09:04:56.825Z",
- "modifiedAt": "2026-11-06T12:26:46.881Z",
+ "modifiedAt": "2026-11-24T16:15:50.226Z",
"url": "https://openreview.net/forum?id=xRChOCRUJY&noteId=VE3KWbNcg9",
"license": "CC-BY-4.0"
}

reviews/openreview/xrchocrujy/submission.json modified

+++ b/reviews/openreview/xrchocrujy/submission.json
@@ -13,7 +13,9 @@
"medical image segmentation",
"ultrasound",
"dataset"
],
+ "primaryArea": "datasets and benchmarks",
+ "tldr": "Segmentation models adapted without labels keep drawing structures that are absent from free-hand ultrasound frames; we score predicting nothing and use anatomical constraints in self-training to teach them not to.",
"url": "https://openreview.net/forum?id=xRChOCRUJY",
"license": "CC-BY-4.0"
}