CQFA: Channel-Wise Query Feedback for Gated DeltaNet-2
Update ICLR 2027 submission uGKsdWeT42: 1 note
@openreview[bot] · 2026-11-24 15:49 UTC · 7bbe3c29d817 ·
reviews/openreview/ugksdwet42/notes/usly5q50zu.json modified
+++ b/reviews/openreview/ugksdwet42/notes/usly5q50zu.json@@ -13,12 +13,12 @@"critical_strengths": "S1. Technically, the extension is uncomplicated, and it keeps an implementation structure worth keeping: the effective erase direction of Equation (9) still yields a diagonal-plus-rank-one state transition, and Appendix D supplies extensive forward and backward derivations along with reference code.\n\nS2. The scalar-feedback baseline is given the same number of projection parameters as CQFA, a sensible control for the parameters the method adds. GDN-2 and Q-Delta both appear in the experiments, which places the contribution as a particular combination and refinement rather than as the first use of query feedback.\n\nS3. Gains are reported at both scales—Table 3 lists average accuracies of 47.88% and 58.39%—and throughput is measured directly. The local analysis is backed by measured gate and readout statistics with cluster-level uncertainty, so it does not rest on an algebraic possibility alone.","critical_weaknesses": "W1. The controlled-retrieval figures do not match the evaluation protocol as described. According to Appendix A.1 there are 384 examples per input seed, and Table 5 reports the best of three seeds; Equation (18) and Appendix A.4 assign a single binary target to each S-NIAH example. Any such percentage therefore has to be a multiple of 100/384, so a score short of perfect cannot exceed 99.7396%. Yet the GDN-2 entry for S-NIAH-1 at 1K reads 99.98%, and other entries are likewise incompatible with that denominator. Taking the maximum over three sets of this kind does not lift the constraint. The effective denominator, the metric, and the aggregation need to be brought into agreement before these results can be read with confidence.\n\nW2. Gate granularity is not isolated by the scalar-versus-channel comparison. In Appendix B, Scalar-Q runs with L_s=1.0 whereas CQFA runs with L=0.4, and on top of that the scalar logits are pooled before the sigmoid. Since the feedback range can affect both stability and optimization, matching parameter counts—valuable though it is—leaves open whether the improvement stems from channel-specific control or simply from a better setting of feedback strength. The fixed-state expressivity comparison of Equation (30) assumes a common bound, so it does not resolve this confound in the experiments.\n\nW3. Because best scores are what get reported, how reliable the task gains are remains unclear. Section 4.1 mentions three training seeds yet reports the best of them, and Appendix A.1 states that a single checkpoint is used across the tables without saying how it was chosen. Means, a measure of spread, and an account of how training-seed selection relates to input-seed selection are needed—all the more so because the aggregate improvements are relatively small. The very small reductions in local residual energy in Appendix E back a diagnostic observation but do not, on their own, establish the downstream gain.","questions_for_authors": "Q1. Could you share the effective sample counts behind Table 5, together with the aggregation code or raw counts, and explain how a value of 99.98% can arise under the stated protocol of one target per example and 384 examples? If the reported results average over further units, those units should be named and the protocol description revised to match.\n\nQ2. Does the advantage of channel-wise feedback survive when Scalar-Q and CQFA share the same feedback bound and start from comparable gate strengths? A tightly scoped comparison at a common bound goes to the heart of the mechanism being claimed.\n\nQ3. Task summaries per training seed, or a mean with spread, would be welcome, along with the criterion used to pick the displayed checkpoint and a clear separation between training-seed selection and the best-of-three rule applied to synthetic input sets. Under an aggregate with no selection applied, which comparisons still come out favorably?\n\nAs things stand, I lean toward rejecting. The method is plausible, the derivations are useful, and the language-modeling improvements reported are encouraging. The main scalar/channel comparison, however, is confounded, and the controlled-retrieval protocol cannot produce numbers of the form that appear in the table—two issues that bear directly on the central claims. A convincing account of the aggregation, together with a comparison at a common bound, could move my assessment. The one-step contraction identity holds when the current gates and targets are held fixed; I do not read it as a global guarantee of stability. Finally, raising the score/protocol discrepancy is a request for technical clarification and in no way an accusation of misconduct.","flag_for_ethics_review": "No",- "rating": 1,+ "rating": 2,"confidence": 4},"createdAt": "2026-10-24T07:02:41.299Z",- "modifiedAt": "2026-11-14T12:00:23.719Z",+ "modifiedAt": "2026-11-24T10:48:18.119Z","url": "https://openreview.net/forum?id=uGKsdWeT42¬eId=Usly5Q50Zu","license": "CC-BY-4.0"}