Import ICLR 2027 submission Mi5qLPtKnW: 3 notes
@openreview[bot] · 2026-11-22 21:08 UTC · 56b1824fff39
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,19 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "Mi5qLPtKnW"+ }+ ],+ "title": "ROOTFlow: 3D Tooth Root Synthesis from Intraoral Scans and Panoramic Radiographs via Latent Flow Matching",+ "authors": [],+ "abstract": "Three-dimensional tooth surface morphology and spatial arrangement are important for dental diagnosis and treatment planning. Intraoral scans (IOS) capture detailed crown surfaces but cannot reveal tooth roots, whose three-dimensional morphology and spatial arrangement typically require cone-beam computed tomography (CBCT) to assess, at the cost of additional radiation exposure. Panoramic X-ray (PX) images provide root-related morphological and spatial cues at a lower radiation dose, but their inherent depth ambiguity and geometric distortion limit accurate three-dimensional root reconstruction. We propose ROOTFlow (Root-Oriented Oral Tomography via Latent Flow Matching), a framework that combines IOS-derived crown geometry with radiographic context to generate quadrant-level CBCT volumes and corresponding tooth segmentations, focusing on root surface morphology and spatial arrangement. The framework comprises four components: (i) quadrant-level data construction, in which unsigned distance fields (UDFs) encode IOS meshes as volumetric geometric priors; (ii) latent representation learning with two 3D variational autoencoders that compress CBCT and UDF inputs; (iii) cross-modal contrastive alignment that maps CBCT and PX features into a shared representation space; and (iv) conditional 3D latent flow matching, in which a velocity network conditioned on UDF latent features and PX features guides flow integration to generate a CBCT latent representation. The generated latent representation is jointly decoded into a quadrant-level CBCT volume and corresponding tooth segmentation. PX features provide complementary morphological and contextual cues rather than metrically reliable three-dimensional measurements. We construct a quadrant-level dataset comprising matched CBCT–IOS–PX trios derived from 5,682 patients. Evaluations using general and root-specific metrics demonstrate that ROOTFlow outperforms all evaluated baselines, with improved geometric fidelity of synthesized tooth root surfaces and more accurate tooth positioning.",+ "year": 2027,+ "venue": "ICLR 2027 (under review)",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://potentialpaper.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/mi5qlptknw/forms.json added
+++ b/reviews/openreview/mi5qlptknw/forms.json@@ -0,0 +1,183 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "additional_comments_on_reviewer_discussion",+ "label": "Reviewer discussion",+ "type": "text"+ },+ {+ "key": "recommendation",+ "label": "Recommendation",+ "type": "choice"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "soundness",+ "presentation",+ "informativeness"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "soundness",+ "label": "Soundness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "presentation",+ "label": "Presentation",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "informativeness",+ "label": "Informativeness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "paper_summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "critical_strengths",+ "label": "Strengths",+ "type": "text"+ },+ {+ "key": "critical_weaknesses",+ "label": "Weaknesses",+ "type": "text"+ },+ {+ "key": "questions_for_authors",+ "label": "Questions for the authors",+ "type": "text"+ },+ {+ "key": "flag_for_ethics_review",+ "label": "Flag for ethics review",+ "type": "choice",+ "omitWhen": [+ "No",+ "No ethics review needed."+ ]+ },+ {+ "key": "details_of_ethics_concerns",+ "label": "Ethics concerns",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/mi5qlptknw/notes/02c3hkva55.json added
+++ b/reviews/openreview/mi5qlptknw/notes/02c3hkva55.json@@ -0,0 +1,25 @@+{+ "schema": "review/1",+ "id": "02C3HkvA55",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer vwe7",+ "content": {+ "paper_summary": "The paper proposes ROOTFlow, a framework for reconstructing 3D tooth anatomy from intraoral scans (IOS) and panoramic radiographs (PX). IOS provides patient-specific crown geometry, while PX supplies complementary information about otherwise unobserved roots.\nThe method represents crown meshes as unsigned distance fields and trains separate 3D variational autoencoders for IOS-derived inputs and CBCT targets. A contrastive alignment stage learns corresponding CBCT and radiographic representations. A conditional flow-matching network then transports the IOS latent representation toward a CBCT latent representation, conditioned on crown geometry and PX features. A decoder jointly produces a CBCT-like volume and tooth segmentations. The results support the complete reconstruction pipeline, but do not yet establish accurate recovery of isolated roots or the individual benefits of its main components.",+ "presentation": 2,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "1. Combining observed crown geometry with radiographic root information is a sensible approach to an underdetermined problem. The paper appropriately treats panoramic features as morphological evidence rather than metrically reliable 3D measurements.\n\n2. The cohort of 5,682 patients is a significant empirical asset. Patient-level splitting avoids the obvious leakage risk of placing quadrants from the same patient in different partitions. Including mixed dentition also broadens the anatomical variation represented during training.\n\n3. IOS geometry serves both as the initial flow state and as a persistent condition. Joint intensity and segmentation decoding provides complementary supervision, while the frozen decoder supplies an anatomical representation through which endpoint losses can train the velocity network.\n\n4. Relative to PX2Tooth, ROOTFlow improves whole-tooth DSC from approximately 0.762 to 0.835 and reduces ASD from 0.668 to 0.469 mm. Improvements also extend to length and orientation descriptors. The common-tooth analysis preserves the geometric advantage, strengthening the evidence beyond comparisons with different tooth coverage.\n\n5. The manuscript distinguishes real from synthetic panoramic inputs, reports valid-instance counts, and acknowledges that morphological peaks are not validated anatomical root counts. It also reports unfavorable intensity-threshold results rather than selecting only thresholds that support its ranking.",+ "critical_weaknesses": "1. DSC and ASD are measured on whole teeth, including crowns already observed through IOS. Whole-tooth PCA axes and lengths also combine crown and root geometry. Consequently, strong scores may partly reflect accurate reconstruction of known anatomy rather than recovery of hidden roots. Root-only surface errors, apex localization, root branching, and anatomically annotated root counts are needed. The paper acknowledges this limitation, but it remains central to assessing the contribution.\n\n2. IOS meshes are manually registered to CBCT coordinates, training crops use tooth-label bounds, and standalone prediction reads a reference image header. These choices do not automatically invalidate the experiments, but the evaluation must specify exactly which reference-derived transforms, crop parameters, and metadata are available at prediction time. The current results do not clearly establish performance for a complete IOS–PX-only workflow.\n\n3. The experiments evaluate the full pipeline without isolating contrastive alignment, patient-specific PX conditioning, IOS initialization, persistent geometric conditioning, or endpoint supervision. It therefore remains unclear whether the improvement requires flow matching or could be obtained with a simpler supervised latent predictor. Unaligned PX features and shuffled-PX controls would be particularly informative.\n\n4. Some volumetric baselines have different input assumptions and do not exploit IOS in the same way. Their poorer performance cannot isolate the benefit of the proposed learning method from the benefit of additional geometric information. ToothInpaintor, identified as the closest input setting, is absent from the experiments. A strong baseline receiving the same IOS and PX inputs is necessary.\n\n5. Oral-3D, NeBLa, and reference volumes are processed by an external instance segmenter, whereas ROOTFlow also produces segmentation outputs directly. The precise source of ROOTFlow’s evaluated masks needs clarification. If its native predictions are compared with externally extracted baseline masks, the reported differences combine reconstruction quality with segmentation-pipeline effects. Agreement with independently verified annotations would strengthen the comparison.\n\n6. Geometry is evaluated only when a tooth is present in both prediction and reference. Missing or hallucinated teeth therefore do not directly worsen DSC or ASD. Common-tooth analysis improves comparability, but selects teeth successfully represented by every method and can exclude difficult cases. Presence accuracy alone is insufficient because it includes true negatives and accepts any nonempty prediction. Tooth-presence precision, recall, and metrics penalizing missing teeth would provide a fuller assessment.\n\n7. Fixed IOS and PX inputs yield a single reconstruction, despite the acknowledged possibility of multiple compatible root geometries. The method provides no calibrated indication of where the inferred anatomy is uncertain. This limits interpretation of patient-specific root predictions, especially for unusual anatomy that may be poorly represented by learned priors.\n\n8. The manuscript does not adequately characterize performance across scanners, institutions, ages, dentition stages, or abnormal anatomy. The role of the 1,101-patient “testing” partition versus the 161-patient “evaluation” partition also needs explanation. Confidence intervals, repeated-training variability, inference time, and memory requirements are not reported. Separate quadrant generation and heuristic overlap handling further leave full-jaw consistency unverified.",+ "questions_for_authors": "1. Can you report root-only reconstruction accuracy? In particular, please evaluate root-surface distance, apex localization, and branching or root-count accuracy using independent anatomical annotations.\n\n2. Which CBCT-derived information is used during evaluation preprocessing? Please distinguish training supervision from inference-time registration, crop placement, reference headers, and coordinate preparation.\n\n3. How much does patient-specific PX information contribute? Please compare IOS-only, PX-only, unaligned PX features, and shuffled or mismatched PX conditioning.\n\n4. Why is flow matching necessary? How does it compare with direct latent regression or another reconstruction model using identical inputs, representations, and supervision?\n\n5. Can ToothInpaintor and a strong same-input baseline be included? This would help separate architectural improvements from differences in available information.\n\n6. Which segmentation outputs are scored for ROOTFlow? Do its gains persist when every generated volume is processed by the same external segmenter and evaluated against human-verified reference masks?\n\n7. How do missing and hallucinated teeth affect overall performance? Please report presence precision and recall, subgroup coverage, and an evaluation that includes failures excluded from conditional geometry averages.\n\n8. How were the testing and evaluation partitions used? Please clarify model selection, provide patient-level confidence intervals, and report performance across dentition stages, acquisition settings, and difficult anatomical cases.",+ "flag_for_ethics_review": "Yes",+ "details_of_ethics_concerns": "There are no Institutional Review Board (IRB) mentioned for research purposes.",+ "rating": 2,+ "confidence": 4+ },+ "createdAt": "2026-10-21T10:38:14.201Z",+ "modifiedAt": "2026-11-06T12:27:38.185Z",+ "url": "https://openreview.net/forum?id=Mi5qLPtKnW¬eId=02C3HkvA55",+ "license": "CC-BY-4.0"+}
reviews/openreview/mi5qlptknw/notes/ee5ufpobez.json added
+++ b/reviews/openreview/mi5qlptknw/notes/ee5ufpobez.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "eE5UFpOBeZ",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer QrzZ",+ "content": {+ "paper_summary": "The authors propose ROOT-Flow, a framework combining IOS-driven crown geometry and Panoramic imagery which provide the complementary hidden root-related spatial cues to reconstruct Three-dimensional teeth surface and roots, obviates the need for CBCT which come at cost of high radiation exposure. Their goal is to reconstruct the quadrant level CBCT volume and their corresponding teeth segmentation. To achieve that, the paper propose a 4 stage pipeline. At start of the pipeline, it encodes the IOS Mesh into UDF volume, after that two 3D VAE encode the UDF and CBCT target quadrants into a latent space and decode them again to learn good representations, then panoramic and CBCT features are aligned together and at the last stage flow matching using velocity network conditioned on the UDF latent features and PX features, guides the flow to generate the CBCT latent features which then decoded using the CBCT VAE decoder to generate the final CBCT quadrant volume and the teeth segmentation. The framework finally evaluated on 161 cases, in terms of volume fidelity, and tooth geometry, achieving the highest Whole-tooth Dice Score, and lowest ASD among the compared methods.",+ "presentation": 3,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "(1) Combining both 3D IOS Crown geometry with Panoramic images is a good and sensible multimodal approach to synthesize CBCT volumes without exposure to high radiation while acquiring the CBCT which is a need in the real world, also Decoding the CBCT latent to the CBCT quadrant and 13 teeth segmentation provides two beneficial outputs using same framework and in a single pass.\n\n(2) The large scale of the training data, 5682 patients, ensures better generalization instead of overfitting a small dataset and the retraining of the other models (Oral-3D, NeBLa) with real and synthetic PX settings for fair comparison with the paper method .",+ "critical_weaknesses": "1. The paper goal is to synthesize the 3D root, but it doesn't provide isolated-root evaluation, instead a whole-tooth evaluation, although the IOS crowns geometry provide high prior for the teeth information which might be the cause of the improvement of the metrics.\n\n2. The authors provide no ablation study at all for their framework components, the impact of the PX features, its cross-alignment with the CBCT features, Endpoint loss, and these ablation are necessary to show the effectiveness, need for each component, and whether they add value or not.\n\n3. The compared methods Oral-3D and NeBLa are provided with panoramic features only while RootFlow have IOS crown geometry with panoramic features which provide advantage to RootFlow over the other methods.\n\n4. The paper mentioned ToothInpaintor in their related work, and its input settings is the closest to them, However they didn't include it in the comparison.\n\n5. The Framework require registration of the IOS mesh with the CBCT target volume which shouldn't exist at inference and evaluation time.\n\n6. The use of external segmentation tool only on the synthesized outputs of Oral-3D and NeBLa, without applying it to the generated CBCT from RootFLow. The accuracy of the segmentation tool is not shown, and to ensure fair comparison the segmentation tool need to be used for the all generated CBCT volumes from all methods.",+ "questions_for_authors": "1. Can you provide isolated-root metrics for Dice score and ASD, instead of whole-tooth metrics by isolating the IOS crown ?\n\n2. Can you retrain Oral-3D and NeBLa providing the UDF volume features along with panoramic features and report again the Whole-tooth, and isolated-root metrics ?\n\n3. Can you perform these ablation studies: (1) IOS-only features, (2) Isolating CBCT-PX cross alignment (3) Isolating endpoint loss ?\n\n4. Can you make comparison between RootFLow and the other methods by applying the segmentation tool to their synthesized CBCT volumes (both RootFlow and the other methods) and provide the Whole-tooth and isolated-root Dice and ASD ?\n\n5. Please Clarify what you do at inference time regarding the registration of the IOS mesh.",+ "flag_for_ethics_review": "No",+ "rating": 2,+ "confidence": 3+ },+ "createdAt": "2026-10-22T05:15:15.946Z",+ "modifiedAt": "2026-11-06T12:27:36.975Z",+ "url": "https://openreview.net/forum?id=Mi5qLPtKnW¬eId=eE5UFpOBeZ",+ "license": "CC-BY-4.0"+}
reviews/openreview/mi5qlptknw/notes/nhko2l6k7o.json added
+++ b/reviews/openreview/mi5qlptknw/notes/nhko2l6k7o.json@@ -0,0 +1,25 @@+{+ "schema": "review/1",+ "id": "nhkO2L6k7o",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer JnUi",+ "content": {+ "paper_summary": "This paper presents ROOTFlow, a framework for generating quadrant-level CBCT-like volumes and\ncomplete tooth segmentations from intraoral-scan-derived crown geometry and a same-patient\npanoramic radiograph. IOS crowns are represented as a truncated unsigned distance field with\ntooth-identity channels. Separate 3D variational autoencoders encode the IOS representation and the\nCBCT intensity/segmentation target. A 3D CBCT encoder and SigLIP2 panoramic encoder are trained\nusing a symmetric contrastive objective with auxiliary tooth-presence supervision. A conditional 3D\nvelocity network then transports the IOS latent toward the paired CBCT latent using straight-path flow\nmatching, conditioned on IOS and panoramic global and patch-level features. The endpoint is decoded\ninto a CBCT-like volume and per-tooth segmentation.\nThe study uses matched CBCT, IOS, and clinical panoramic observations from 5,682 patients, with\npatient-level splitting and evaluation on 161 patients. ROOTFlow is compared with Oral-3D and NeBLa\nunder real- and synthetic-panoramic configurations and with PX2Tooth for tooth geometry. It achieves\nthe best reported whole-tooth Dice and average surface distance and outperforms the evaluated\nreal-panoramic volumetric baselines in PSNR, SSIM, and LPIPS.",+ "presentation": 3,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "1. Large paired clinical multimodal cohort. The study uses matched CBCT, IOS, and clinical\npanoramic observations from 5,682 patients with patient-level data separation. Paired clinical data at\nthis scale are difficult to obtain and allow learning from real panoramic acquisition effects rather than\nexclusively from CBCT-derived synthetic projections.\n2. Coherent multimodal formulation and strong reported whole-tooth performance. IOS\ncrown geometry provides a well-motivated 3D anchor, and the complete system achieves strong\nwhole-tooth overlap and surface-distance results. The paper distinguishes real- and\nsynthetic-panoramic settings, reports common-tooth analyses, and provides per-position counts,\nimproving empirical transparency.",+ "critical_weaknesses": "1. The central tooth-root claim is not directly evaluated. The paper is framed as patient-specific tooth-root synthesis,\nbut the primary geometric evaluations operate on whole-tooth masks. Because the patient-specific 3D crown is already\nobserved through IOS, it may substantially determine whole-tooth Dice, ASD, PCA length, orientation, and spatial\narrangement. The posterior morphological-peak descriptor is not a validated anatomical root-count measure, and the paper\ndoes not report root-only overlap or surface metrics, root-apex localization, root count, bifurcation, or curvature. Thus, the\nexperiments demonstrate accurate IOS-anchored whole-tooth completion, but do not establish accurate recovery of the\nunobserved patient-specific roots. This directly affects the title, motivation, and main contribution.\n2. The experiments do not isolate panoramic-image utility or the latent-flow mechanism. There is no IOS-only\nbaseline, correct-versus-shuffled panoramic test, alignment ablation, or direct latent-regression comparison. The model could\ntherefore obtain strong whole-tooth results from a crown-conditioned population prior while using limited patient-specific\npanoramic information. Since the IOS and CBCT autoencoders are trained independently, it is also unclear why straight-line\nlatent transport is preferable to direct conditional prediction. The main comparisons change both input information and\nmethod: ROOTFlow receives an accurate 3D IOS prior, whereas Oral-3D and NeBLa are primarily panoramic-based. They\nvalidate the complete system, but do not identify latent flow matching as the cause of the gain. The closest input setting,\nToothInpaintor, is discussed but not experimentally compared.",+ "questions_for_authors": "Q1 - Root-specific evaluation. Can the authors report metrics restricted to the unobserved root region, separately from the IOS-observed crown? At\nminimum, root-only Dice, root-surface ASD or HD95, and root-apex localization error are needed. If crown-root boundaries are not annotated, please give a\nreproducible separation procedure and sensitivity analysis. Root-number accuracy, molar root divergence, and root-curvature measurements would further\nstrengthen the evaluation.\n\nQ2 - Incremental value of the patient-specific panoramic image. Under the same architecture and training protocol, can the authors compare: (i)\nIOS only; (ii) IOS plus the correct panoramic image; (iii) IOS plus another patient's panorama with similar tooth presence; and (iv) IOS plus zeroed or\nmasked panoramic features? Please report root-only metrics. This is necessary to show that the model extracts patient-specific root information rather\nthan mainly performing tooth-identity- and crown-conditioned statistical completion.\n\nQ3 - Necessity of alignment and flow matching. Can the authors compare no CBCT-PX contrastive alignment, global-only versus patch-only\npanoramic conditioning, direct CBCT-latent regression, one-step endpoint prediction, and different flow-integration step counts? Please explain why\nstraight-line interpolation between independently learned IOS and CBCT latent spaces is appropriate. A clear advantage over direct regression is needed to\nsubstantiate the flow contribution.\n\nQ4 - Coordinate preparation and target-derived information. For the 161 evaluation cases, how is the IOS-to-output frame obtained; does the\ntransform use the target CBCT; do crop bounds use reference tooth labels; where does the reference image header come from without target CBCT; does\npanoramic cropping use manual/reference assistance; and are automatic segmentation, numbering, detection, and registration errors included? If\ntarget-derived coordinates are used, please provide an oracle-coordinate baseline and a fully target-independent evaluation.\n\nQ5 - Symmetry of geometry evaluation. Oral-3D, NeBLa, and the reference are processed by an external tooth-instance segmenter, whereas\nROOTFlow directly outputs tooth-label channels. Can the authors apply the same segmenter to ROOTFlow intensity volumes, or otherwise use an identical\nprotocol and human-verified references for all methods? Please also report detection-aware metrics that penalize missing/extra teeth, and clarify the roles\nof the 1,101-patient testing set and 161-patient evaluation set, including which data informed checkpoint selection and method development.",+ "flag_for_ethics_review": "Yes",+ "details_of_ethics_concerns": "The study uses linked clinical CBCT, IOS, panoramic radiographs, and manually assisted annotations from\n5,682 patients, including patients with mixed dentition. However, the ethics statement does not specify\ninstitutional review board or ethics-committee approval, informed consent or waiver of consent,\nde-identification procedures, data-use authorization, participating institutions, or safeguards for handling\nlinked multimodal patient data. This flag reflects missing documentation rather than evidence of\nmisconduct. The relevant approval identifier and a description of consent or waiver, de-identification, and\ndata governance should be provided.",+ "rating": 1,+ "confidence": 4+ },+ "createdAt": "2026-10-20T06:58:32.807Z",+ "modifiedAt": "2026-11-06T12:27:39.220Z",+ "url": "https://openreview.net/forum?id=Mi5qLPtKnW¬eId=nhkO2L6k7o",+ "license": "CC-BY-4.0"+}
reviews/openreview/mi5qlptknw/submission.json added
+++ b/reviews/openreview/mi5qlptknw/submission.json@@ -0,0 +1,20 @@+{+ "schema": "submission/1",+ "id": "Mi5qLPtKnW",+ "venue": {+ "id": "ICLR.cc/2027/Conference",+ "name": "ICLR 2027",+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference"+ },+ "number": 30596,+ "keywords": [+ "3D tooth root synthesis",+ "Tooth morphology and spatial arrangement",+ "Intraoral scans",+ "Panoramic radiographs",+ "Latent flow matching",+ "Cross-modal alignment"+ ],+ "url": "https://openreview.net/forum?id=Mi5qLPtKnW",+ "license": "CC-BY-4.0"+}
versions/v_krrjkgcx.json added
+++ b/versions/v_krrjkgcx.json@@ -0,0 +1,21 @@+{+ "date": "2026-09-17",+ "kind": "submitted",+ "label": "ICLR 2027",+ "submissions": [+ {+ "venue": "ICLR 2027",+ "status": "under_review",+ "number": 30596,+ "url": "https://openreview.net/forum?id=Mi5qLPtKnW",+ "reviews": "openreview/mi5qlptknw",+ "evidence": [+ "https://openreview.net/forum?id=Mi5qLPtKnW"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=Mi5qLPtKnW",+ "evidence": [+ "https://openreview.net/forum?id=Mi5qLPtKnW"+ ]+}