Measure, Calibrate, Refuse and Verify: An Evidence Contract for Mobile AQA
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 19:41 UTC · dfe07d143936 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "1HANTnOPKP"- }- ],- "title": "Measure, Calibrate, Refuse and Verify: An Evidence Contract for Mobile AQA",- "authors": [],- "abstract": "Deployment-facing action quality assessment combines repeated observations, user adaptation, human review, physical measurements, and abstention, yet these components are often evaluated as if their evidence were independent. We formulate an *evidence contract*: every adaptive or human-assisted degree of freedom requires a matching source of evaluation independence. We instantiate the contract in a longitudinal audit of an eight-month mobile rehabilitation system and obtain four paired reversals. Same-user threshold fitting raised accuracy from $0.738$ to $0.918$, whereas nested leave-one-user-out calibration achieved $0.557$. Pooled repetition agreement of $0.937$ became $0.748$ when users received equal weight. On the same 23 videos and frozen predictions, model agreement changed from $0.913$ under model-visible review to $0.391$ against blind consensus; 51 videos were retrospectively labeled, of which 38 entered frozen-rule scoring after exclusions, yielding error-detection accuracies of $0.167$ and $0.357$ for two exercises. Finally, within-user correlation of $0.807$ coexisted with centimeter limits of agreement $[-7.1,+4.2]$, while refusal retained $0.137$ user-level risk at $0.964$ coverage. The resulting evaluation stack—user-level aggregation, nested adaptation, blind-first labeling, measurement agreement, and coverage–risk analysis—turns apparently reliable outputs into testable stage-wise claims. It applies beyond rehabilitation wherever systems personalize, expose machine suggestions to reviewers, or withhold predictions.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "2c726125-de3e-4a8d-bcda-d77d20855fea"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "Measure, Calibrate, Refuse and Verify: An Evidence Contract for Mobile AQA",+ "authors": [],+ "abstract": "Deployment-facing action quality assessment combines repeated observations, user adaptation, human review, physical measurements, and abstention, yet these components are often evaluated as if their evidence were independent. We formulate an *evidence contract*: every adaptive or human-assisted degree of freedom requires a matching source of evaluation independence. We instantiate the contract in a longitudinal audit of an eight-month mobile rehabilitation system and obtain four paired reversals. Same-user threshold fitting raised accuracy from $0.738$ to $0.918$, whereas nested leave-one-user-out calibration achieved $0.557$. Pooled repetition agreement of $0.937$ became $0.748$ when users received equal weight. On the same 23 videos and frozen predictions, model agreement changed from $0.913$ under model-visible review to $0.391$ against blind consensus; 51 videos were retrospectively labeled, of which 38 entered frozen-rule scoring after exclusions, yielding error-detection accuracies of $0.167$ and $0.357$ for two exercises. Finally, within-user correlation of $0.807$ coexisted with centimeter limits of agreement $[-7.1,+4.2]$, while refusal retained $0.137$ user-level risk at $0.964$ coverage. The resulting evaluation stack—user-level aggregation, nested adaptation, blind-first labeling, measurement agreement, and coverage–risk analysis—turns apparently reliable outputs into testable stage-wise claims. It applies beyond rehabilitation wherever systems personalize, expose machine suggestions to reviewers, or withhold predictions.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}