potentialpaper

Calibration Is Grouping: VR-SAG with Intra-Group Variance Control and Logit-Cluster Evaluation

Import the versions from OpenReview: the same title at other venues

@openreview[bot] · 2026-11-22 19:46 UTC · 1f66296a58e3 ·

versions/v_45g8bmh9.json added

+++ b/versions/v_45g8bmh9.json
@@ -0,0 +1,18 @@
+{
+ "date": "2025-09-18",
+ "kind": "submitted",
+ "label": "ICLR 2026",
+ "submissions": [
+ {
+ "venue": "ICLR 2026",
+ "status": "rejected",
+ "url": "https://openreview.net/forum?id=lPQOPD1tcm"
+ }
+ ],
+ "title": "Calibration Is Grouping: VR-SAG with Intra-Group Variance Control and Logit-Cluster Evaluation",
+ "url": "https://openreview.net/forum?id=lPQOPD1tcm",
+ "evidence": [
+ "https://openreview.net/forum?id=lPQOPD1tcm"
+ ],
+ "abstract": "Accurate click-through and conversion-rate estimates are pivotal for bid optimization in large-scale advertising, yet modern deep CTR/CVR models are often miscalibrated. Classical global calibrators (Platt scaling, isotonic regression) and feature-based binning struggle to capture latent user–item heterogeneity. We approach calibration through the lens of latent, calibration-aware groupings and propose Variance-Reduced Semantic-Aware Grouping (VR-SAG)}—a lightweight post-hoc layer over a frozen backbone that (i) forms semantically coherent partitions in embedding space, (ii) fits per-group temperature+bias calibrators, and (iii) explicitly penalizes intra-group variance to tighten probability spreads.\nOur design is grounded in a group-wise decomposition of proper scoring rules (e.g., Brier), which isolates intra-group variance as a key driver of residual miscalibration and motivates variance control for genuine loss reduction. To decouple evaluation from training, we introduce Logit-Cluster Calibration Error (LCCE), an unsupervised fixed-partition metric obtained via $K$-means in logit space; LCCE aligns with the reliability term of proper scores while avoiding pitfalls of trainable grouping heads used as metrics.\nAcross large-scale offline logs and AdAuction—a large-scale ad-auction dataset with oracle CTRs generated by an internal ad-auction simulator—VR-SAG consistently improves calibration (ECE/LCCE and Brier variants) over strong baselines, with negligible latency and memory overhead."
+}

versions/v_75tf3pkj.json added

+++ b/versions/v_75tf3pkj.json
@@ -0,0 +1,18 @@
+{
+ "date": "2026-09-17",
+ "kind": "submitted",
+ "label": "ICLR 2027",
+ "submissions": [
+ {
+ "venue": "ICLR 2027",
+ "status": "under_review",
+ "url": "https://openreview.net/forum?id=zobgEn3cul"
+ }
+ ],
+ "title": "Calibration Is Grouping: VR-SAG with Intra-Group Variance Control and Logit-Cluster Evaluation",
+ "url": "https://openreview.net/forum?id=zobgEn3cul",
+ "evidence": [
+ "https://openreview.net/forum?id=zobgEn3cul"
+ ],
+ "abstract": "Accurate click-through and conversion-rate estimates are pivotal for bid optimization in large-scale advertising, yet modern deep CTR/CVR models are often miscalibrated. Classical global calibrators (Platt scaling, isotonic regression) and feature-based binning struggle to capture latent user-item heterogeneity. We approach calibration through the lens of \\emph{latent, calibration-aware groupings} and propose Variance-Reduced Semantic-Aware Grouping (VR-SAG), a lightweight post-hoc layer over a frozen backbone that (i) learns calibration-aware groups in embedding space, (ii) fits per-group temperature+bias calibrators, and (iii) explicitly penalizes intra-group variance to tighten probability spreads.\nA group-wise decomposition of the Brier score guides our design. It separates within-group variance from score--label covariance and motivates a grouping regularizer. To decouple evaluation from training, we introduce Logit-Cluster Calibration Error (LCCE), an unsupervised fixed-partition metric obtained via $K$-means in logit space; LCCE aligns with the reliability term of proper scores while avoiding pitfalls of trainable grouping heads used as metrics.\nAcross offline CTR logs and AdAuction (an ad-auction dataset with simulator-defined oracle CTRs), VR-SAG improves the reported calibration metrics over the corresponding SAG variants. Its additional computation scales linearly with the number of grouping heads and groups."
+}