potentialpaper

PhosInv: Learning a Shared Implant Placement and Stimulus-Conditional Electrode Selection for Visual Cortical Prostheses

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 19:43 UTC · c6156606af96 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "SSTWxVqvBg"
- }
- ],
- "title": "PhosInv: Learning a Shared Implant Placement and Stimulus-Conditional Electrode Selection for Visual Cortical Prostheses",
- "authors": [],
- "abstract": "Visual cortical prostheses aim to restore rudimentary vision by electrically stimulating the primary visual cortex to evoke percepts known as phosphenes. Their design requires determining where to implant a fixed electrode array and which contacts to activate for each target stimulus. Prior work reoptimises implant placement separately for each stimulus, an approach that cannot be implemented once a device has been implanted. We reformulate this task as a generalisation problem: learning a single implant placement shared across a distribution of target stimuli, together with a stimulus-conditional electrode-activation policy. PhosInv implements this formulation as a convolutional inverse model trained end-to-end through a differentiable reimplementation of an existing phosphene simulator. Once trained, it predicts a sparse electrode selection for each new stimulus in a single forward pass, without per-stimulus optimisation. On a benchmark of 2,820 targets from two domains, all scored under the differentiable renderer, domain-matched PhosInv attains lower loss than per-stimulus Bayesian placement search in all six subject hemispheres in both domains. A forward pass takes milliseconds on a GPU against minutes of CPU search per stimulus, a gap that combines amortisation with differences in hardware and implementation, and PhosInv commands six to eight times fewer contacts, reducing delivered charge, a quantity constrained by safety considerations. A model trained on an equal mixture of both domains retains most of each domain-specific model's advantage while avoiding the degradation either shows outside its own domain, indicating that training coverage, not the architecture itself, limits generalisation. Relative to a shared all-contacts-active reference, learned electrode selection contributes about three times the improvement achieved by per-stimulus placement search and far more than a placement searched once per hemisphere, identifying electrode selection as the more consequential lever for future high-density arrays. Every contrast is reported per anatomy, as an effect size and its consistency across six subject hemispheres.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "a3a43b2c-26c9-4399-a6a5-9335f24e7cec"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "PhosInv: Learning a Shared Implant Placement and Stimulus-Conditional Electrode Selection for Visual Cortical Prostheses",
+ "authors": [],
+ "abstract": "Visual cortical prostheses aim to restore rudimentary vision by electrically stimulating the primary visual cortex to evoke percepts known as phosphenes. Their design requires determining where to implant a fixed electrode array and which contacts to activate for each target stimulus. Prior work reoptimises implant placement separately for each stimulus, an approach that cannot be implemented once a device has been implanted. We reformulate this task as a generalisation problem: learning a single implant placement shared across a distribution of target stimuli, together with a stimulus-conditional electrode-activation policy. PhosInv implements this formulation as a convolutional inverse model trained end-to-end through a differentiable reimplementation of an existing phosphene simulator. Once trained, it predicts a sparse electrode selection for each new stimulus in a single forward pass, without per-stimulus optimisation. On a benchmark of 2,820 targets from two domains, all scored under the differentiable renderer, domain-matched PhosInv attains lower loss than per-stimulus Bayesian placement search in all six subject hemispheres in both domains. A forward pass takes milliseconds on a GPU against minutes of CPU search per stimulus, a gap that combines amortisation with differences in hardware and implementation, and PhosInv commands six to eight times fewer contacts, reducing delivered charge, a quantity constrained by safety considerations. A model trained on an equal mixture of both domains retains most of each domain-specific model's advantage while avoiding the degradation either shows outside its own domain, indicating that training coverage, not the architecture itself, limits generalisation. Relative to a shared all-contacts-active reference, learned electrode selection contributes about three times the improvement achieved by per-stimulus placement search and far more than a placement searched once per hemisphere, identifying electrode selection as the more consequential lever for future high-density arrays. Every contrast is reported per anatomy, as an effect size and its consistency across six subject hemispheres.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}