Update ICLR 2027 submission gvjbX6BUOz: 1 note
@openreview[bot] · 2026-11-24 15:44 UTC · a4d2b7107059 ·
reviews/openreview/gvjbx6buoz/notes/knoeaorvoo.json modified
+++ b/reviews/openreview/gvjbx6buoz/notes/knoeaorvoo.json@@ -7,9 +7,9 @@"signature": "Reviewer 52QV","content": {"paper_summary": "This paper tackles few-shot RIR estimation with extra relaxations on audio references. The references are now ordinary signals convolved with RIRs instead of RIRs themselves, and no (relative) source positions are given. An egocentric panoramic depth from a query receiver is also given, following FLAC.\n\nThis setting is not the most general or practically applicable one; it still assumes a single static, omnidirectional source in each recording and does not allow inference at unseen receiver positions (which I see as a missed opportunity). Nevertheless, the current setting should be sufficiently challenging to warrant a standalone investigation.\n\nThe authors then proceed to present quite a complex system that combines a reference encoder, query (depth) encoder, EDC predictor, and a discrete diffusion model that operates on a RQVAE-based RIR codec. Results are reported on the synthetic AcousticRooms dataset (Treble wave+path tracing simulations) and the HAA dataset (real-world measurements).","presentation": 3,- "informativeness": 1,+ "informativeness": 2,"soundness": 2,"critical_strengths": "The proposed work relaxes the FLAC setup in two ways, closing the gap between the lab settings and actual potential application scenarios.","critical_weaknesses": "After the problem formulation, the paper immediately jumps into building a complex system and reporting the benchmark numbers. As a result, the current manuscript misses several research questions that I find more interesting. Why and how does the relaxation make the task more difficult? What kind of specific acoustic details do we miss? In which scenario does the task become more difficult? When and why does the baseline struggle in particular? Without these investigations, it is not clear how each part of the proposed model motivates itself over its baseline counterparts. \n\nI believe the baseline comparisons are not fair and should not be the main focus of the paper. It puzzles me how Speech2RIR and Lluis's (2025) Blind SRIR model can be compared with the proposed method. From my understanding, they are not designed for the task tackled here at all; they are not few-shot (K>1) estimators and do not take the panoramic depth as input. FLAC, EigeNet, and xRIR might be a better match, but they still aren't designed to capture room acoustic features effectively from reverberant recordings; they are designed for RIRs.","questions_for_authors": "I left key questions in the weaknesses section. Below are the remaining questions and additional comments.\n\nCould the authors please elaborate on how the baseline systems were adapted to the presented setup? The appendix seems a bit brief.\n\nI find that at least the following ablation studies are needed. Please correct me if I am wrong.\n\n(1) w/ RIRs & source positions\n(2) w/o RIRs but with source positions\n(3) w/ RIRs but without source positions\n(4) w/o RIRs & source positions (i.e., current setting)\n\nI would like to see a small set of qualitative examples demonstrating the nature of the task and the behavior of the proposed model (plus baseline models). For example, we can pick a challenging scene with many occlusions (e.g., one of the Apartment scenes in AcousticRooms), draw room acoustic parameter and pressure distribution plots, and discuss what is happening there. I find Figures 7 and 9 to be a great starting point.\n\nIt seems like the acoustic planner predicts full-band EDC. Did the authors try frequency-dependent ones, e.g., octave-band decays or energy decay relief (EDR)?\n\nWhy not enforce (e.g., renormalize) the generated RIR to match the EDC, instead of the best-of-N inference?\n\nWhile the paper is generally clear, are all math symbols defined in the text (e.g., R_\\theta)? Personally, I found those equations redundant and, at times, confusing.\n\nAppendix A can be merged with Appendix B. Appendix C (metrics) seems to be redundant. \n\nAppendix D.6: It seems like more refinement steps do not improve performance. Why? Is this an intended outcome or explainable behavior? Is the decoder truly \"generative\"?\n\nAppendix D.7: Did the authors retrain the baseline codes for RIRs? \n\nAppendix D.8: Why do we need both query-weighted and room-macro results? What extra insights do we gain here?",@@ -17,8 +17,8 @@"rating": 2,"confidence": 4},"createdAt": "2026-10-22T09:11:03.887Z",- "modifiedAt": "2026-11-06T12:29:00.810Z",+ "modifiedAt": "2026-11-23T06:36:14.236Z","url": "https://openreview.net/forum?id=gvjbX6BUOz¬eId=knoEaOrvOo","license": "CC-BY-4.0"}
reviews/openreview/gvjbx6buoz/submission.json modified
+++ b/reviews/openreview/gvjbx6buoz/submission.json@@ -5,9 +5,11 @@"id": "ICLR.cc/2027/Conference"},"number": 33586,"keywords": [- "Acoustic Field Reconstruction; Generative Models; Spatial Audio"+ "Acoustic Field Reconstruction",+ "Generative Models",+ "Spatial Audio"],"url": "https://openreview.net/forum?id=gvjbX6BUOz","license": "CC-BY-4.0"}