ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 19:46 UTC · ab7eb1d8cd97 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "V6XpEIrCr0"- }- ],- "title": "ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography",- "authors": [],- "abstract": "Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and ECG instrumentation. While large language models have proven effective for such applications, existing language-models primarily assess broad medical knowledge or the interpretation of individual ECG signals and images, rather than comprehensive context knowledge required for ECG interpretation. We built ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. An automated GPT-4o-based pipeline generated questions from 23 ECG references and proceedings of the Computing in Cardiology conference between 2003–2025. The final dataset contains 10,904 unique True/False questions paired with their negated form derived from the same source (21,808 Q&A in total). We evaluated three commercial and 20 open-source language models on the held-out ECGQuest test set in a zero-shot setting. We also fine-tuned five open-source models with 7–14 B parameters using Low-Rank Adaptation and included BERT and BiomedBERT as supervised encoder baselines. Generalization was evaluated using ECG-related subsets of MedMCQA and MedQA datasets converted to binary True/False questions using their official examination answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 achieving the highest accuracy. General-purpose models outperformed all medically specialized models, and several models showed strong directional True/False biases. Encoder baselines performed near chance. Fine-tuning improved all open-source models on ECGQuest by 6.5–14.1%. The fine-tuned DeepSeek-R1-Distill-Qwen-14 B model achieved 76.3% accuracy, and a five-model voting ensemble achieved the highest overall accuracy of 78.5%. On MedMCQA and MedQA, fine-tuning primarily benefited weak or class-biased models and did not consistently improve already strong base models. ECGQuest is a reproducible benchmark for evaluating contextual ECG knowledge in language models and demonstrates that targeted, parameter-efficient fine-tuning can make small language models competitive with substantially larger commercial models.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "3a443a91-99cf-4347-9162-39b7f6d918b2"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography",+ "authors": [],+ "abstract": "Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and ECG instrumentation. While large language models have proven effective for such applications, existing language-models primarily assess broad medical knowledge or the interpretation of individual ECG signals and images, rather than comprehensive context knowledge required for ECG interpretation. We built ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. An automated GPT-4o-based pipeline generated questions from 23 ECG references and proceedings of the Computing in Cardiology conference between 2003–2025. The final dataset contains 10,904 unique True/False questions paired with their negated form derived from the same source (21,808 Q&A in total). We evaluated three commercial and 20 open-source language models on the held-out ECGQuest test set in a zero-shot setting. We also fine-tuned five open-source models with 7–14 B parameters using Low-Rank Adaptation and included BERT and BiomedBERT as supervised encoder baselines. Generalization was evaluated using ECG-related subsets of MedMCQA and MedQA datasets converted to binary True/False questions using their official examination answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 achieving the highest accuracy. General-purpose models outperformed all medically specialized models, and several models showed strong directional True/False biases. Encoder baselines performed near chance. Fine-tuning improved all open-source models on ECGQuest by 6.5–14.1%. The fine-tuned DeepSeek-R1-Distill-Qwen-14 B model achieved 76.3% accuracy, and a five-model voting ensemble achieved the highest overall accuracy of 78.5%. On MedMCQA and MedQA, fine-tuning primarily benefited weak or class-biased models and did not consistently improve already strong base models. ECGQuest is a reproducible benchmark for evaluating contextual ECG knowledge in language models and demonstrates that targeted, parameter-efficient fine-tuning can make small language models competitive with substantially larger commercial models.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}