potentialpaper

ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 19:46 UTC · ab7eb1d8cd97 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "V6XpEIrCr0"
- }
- ],
- "title": "ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography",
- "authors": [],
- "abstract": "Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and ECG instrumentation. While large language models have proven effective for such applications, existing language-models primarily assess broad medical knowledge or the interpretation of individual ECG signals and images, rather than comprehensive context knowledge required for ECG interpretation. We built ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. An automated GPT-4o-based pipeline generated questions from 23 ECG references and proceedings of the Computing in Cardiology conference between 2003–2025. The final dataset contains 10,904 unique True/False questions paired with their negated form derived from the same source (21,808 Q&A in total). We evaluated three commercial and 20 open-source language models on the held-out ECGQuest test set in a zero-shot setting. We also fine-tuned five open-source models with 7–14 B parameters using Low-Rank Adaptation and included BERT and BiomedBERT as supervised encoder baselines. Generalization was evaluated using ECG-related subsets of MedMCQA and MedQA datasets converted to binary True/False questions using their official examination answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 achieving the highest accuracy. General-purpose models outperformed all medically specialized models, and several models showed strong directional True/False biases. Encoder baselines performed near chance. Fine-tuning improved all open-source models on ECGQuest by 6.5–14.1%. The fine-tuned DeepSeek-R1-Distill-Qwen-14 B model achieved 76.3% accuracy, and a five-model voting ensemble achieved the highest overall accuracy of 78.5%. On MedMCQA and MedQA, fine-tuning primarily benefited weak or class-biased models and did not consistently improve already strong base models. ECGQuest is a reproducible benchmark for evaluating contextual ECG knowledge in language models and demonstrates that targeted, parameter-efficient fine-tuning can make small language models competitive with substantially larger commercial models.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "3a443a91-99cf-4347-9162-39b7f6d918b2"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography",
+ "authors": [],
+ "abstract": "Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and ECG instrumentation. While large language models have proven effective for such applications, existing language-models primarily assess broad medical knowledge or the interpretation of individual ECG signals and images, rather than comprehensive context knowledge required for ECG interpretation. We built ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. An automated GPT-4o-based pipeline generated questions from 23 ECG references and proceedings of the Computing in Cardiology conference between 2003–2025. The final dataset contains 10,904 unique True/False questions paired with their negated form derived from the same source (21,808 Q&A in total). We evaluated three commercial and 20 open-source language models on the held-out ECGQuest test set in a zero-shot setting. We also fine-tuned five open-source models with 7–14 B parameters using Low-Rank Adaptation and included BERT and BiomedBERT as supervised encoder baselines. Generalization was evaluated using ECG-related subsets of MedMCQA and MedQA datasets converted to binary True/False questions using their official examination answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 achieving the highest accuracy. General-purpose models outperformed all medically specialized models, and several models showed strong directional True/False biases. Encoder baselines performed near chance. Fine-tuning improved all open-source models on ECGQuest by 6.5–14.1%. The fine-tuned DeepSeek-R1-Distill-Qwen-14 B model achieved 76.3% accuracy, and a five-model voting ensemble achieved the highest overall accuracy of 78.5%. On MedMCQA and MedQA, fine-tuning primarily benefited weak or class-biased models and did not consistently improve already strong base models. ECGQuest is a reproducible benchmark for evaluating contextual ECG knowledge in language models and demonstrates that targeted, parameter-efficient fine-tuning can make small language models competitive with substantially larger commercial models.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}