Physiologically Aware Flow Matching: Jacobian Constraints for Dose-Consistent Forecasting
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 19:47 UTC · b26cad1f5b5d ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "8uMJWPAG2z"- }- ],- "title": "Physiologically Aware Flow Matching: Jacobian Constraints for Dose-Consistent Forecasting",- "authors": [],- "abstract": "Accurate forecasts under observed treatment plans do not guarantee\nphysiologically consistent responses to altered ones: state-dependent dosing\ncouples treatment to patient state, so models trained on such records learn\nassociations that contradict physiology. We introduce Physiologically\nAware Flow Matching (PAFM), a conditional flow-matching framework for\nprobabilistic forecasting under planned treatments. PAFM regularizes the\nJacobian of the velocity field with respect to pharmacokinetically smoothed\ntreatment drivers, with physiological priors specifying the sign of each\nsensitivity and a band for its magnitude. The penalty is evaluated at sampled\nflow states and operates without a mechanistic outcome model or rollouts under\nalternative plans. We develop autoregressive (AR-PAFM) and joint-horizon\n(JH-PAFM) formulations, which constrain sensitivities at individual forecast\nsteps and across forecast positions respectively, and evaluate both on two\nsimulated closed-loop benchmarks. On glucose, every unregularized model\nintegrates a glucose-raising response to added insulin; the penalty restores\nnear-perfect directional and dose-ordering consistency in both formulations,\nand JH-PAFM achieves lower mean RMSE than all regularized baselines. On mean\narterial pressure, both formulations reach full directional and dose-ordering\nconsistency under propofol and norepinephrine infusions, with JH-PAFM lower\nthan AR-PAFM in mean RMSE and calibration error.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "b936d391-e98f-4572-9067-4e31a13e9bf8"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "Physiologically Aware Flow Matching: Jacobian Constraints for Dose-Consistent Forecasting",+ "authors": [],+ "abstract": "Accurate forecasts under observed treatment plans do not guarantee\nphysiologically consistent responses to altered ones: state-dependent dosing\ncouples treatment to patient state, so models trained on such records learn\nassociations that contradict physiology. We introduce Physiologically\nAware Flow Matching (PAFM), a conditional flow-matching framework for\nprobabilistic forecasting under planned treatments. PAFM regularizes the\nJacobian of the velocity field with respect to pharmacokinetically smoothed\ntreatment drivers, with physiological priors specifying the sign of each\nsensitivity and a band for its magnitude. The penalty is evaluated at sampled\nflow states and operates without a mechanistic outcome model or rollouts under\nalternative plans. We develop autoregressive (AR-PAFM) and joint-horizon\n(JH-PAFM) formulations, which constrain sensitivities at individual forecast\nsteps and across forecast positions respectively, and evaluate both on two\nsimulated closed-loop benchmarks. On glucose, every unregularized model\nintegrates a glucose-raising response to added insulin; the penalty restores\nnear-perfect directional and dose-ordering consistency in both formulations,\nand JH-PAFM achieves lower mean RMSE than all regularized baselines. On mean\narterial pressure, both formulations reach full directional and dose-ordering\nconsistency under propofol and norepinephrine infusions, with JH-PAFM lower\nthan AR-PAFM in mean RMSE and calibration error.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}