TRACE: Temporal Relevance Attribution for Clinical Explanations
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 19:47 UTC · 41a0fc70651c ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "wxYYASfVD4"- }- ],- "title": "TRACE: Temporal Relevance Attribution for Clinical Explanations",- "authors": [],- "abstract": "Irregularly sampled multivariate clinical time series are central to intensive care unit (ICU) risk prediction, yet deployable models must be both highly accurate and faithfully interpretable. Practitioners currently face a sharp trade-off: inherently interpretable architectures often rely on heuristic attention mechanisms without strict faithfulness guarantees, while rigorous post-hoc methods such as Integrated Gradients incur prohibitive computational costs. We introduce Temporal Relevance Attribution for Clinical Explanations (TRACE), a framework that resolves this tension through architecture-attribution co-design, achieving the strongest predictive performance together with single-pass, mathematically exact attribution. TRACE structurally reduces to an affine map for any fixed input, enabling a single backward pass to exactly decompose the prediction logit into signed per-variable, per-timestep contributions with a completeness gap at floating-point round-off. On PhysioNet-2012, PhysioNet-2019, and MIMIC-III, TRACE achieves the highest AUROC and AUPRC of all baselines. Under a graded remove-and-retrain evaluation (gROAR) that sweeps retention budgets with trend and equivalence testing, TRACE consistently outperforms existing inherently interpretable models. Its top-$k$ degradation is comparable to that of Integrated Gradients, yet it runs two orders of magnitude faster and preserves machine-precision faithfulness, with a relative completeness gap on the order of $10^{-6}$. Together, these results show that predictive accuracy, attribution faithfulness, and computational efficiency need not be traded off in clinical time-series modeling.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "1abaf2df-43a3-40c2-9ac6-735d7cd97f00"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "TRACE: Temporal Relevance Attribution for Clinical Explanations",+ "authors": [],+ "abstract": "Irregularly sampled multivariate clinical time series are central to intensive care unit (ICU) risk prediction, yet deployable models must be both highly accurate and faithfully interpretable. Practitioners currently face a sharp trade-off: inherently interpretable architectures often rely on heuristic attention mechanisms without strict faithfulness guarantees, while rigorous post-hoc methods such as Integrated Gradients incur prohibitive computational costs. We introduce Temporal Relevance Attribution for Clinical Explanations (TRACE), a framework that resolves this tension through architecture-attribution co-design, achieving the strongest predictive performance together with single-pass, mathematically exact attribution. TRACE structurally reduces to an affine map for any fixed input, enabling a single backward pass to exactly decompose the prediction logit into signed per-variable, per-timestep contributions with a completeness gap at floating-point round-off. On PhysioNet-2012, PhysioNet-2019, and MIMIC-III, TRACE achieves the highest AUROC and AUPRC of all baselines. Under a graded remove-and-retrain evaluation (gROAR) that sweeps retention budgets with trend and equivalence testing, TRACE consistently outperforms existing inherently interpretable models. Its top-$k$ degradation is comparable to that of Integrated Gradients, yet it runs two orders of magnitude faster and preserves machine-precision faithfulness, with a relative completeness gap on the order of $10^{-6}$. Together, these results show that predictive accuracy, attribution faithfulness, and computational efficiency need not be traded off in clinical time-series modeling.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}