potentialpaper

Hand Kinematics as an Implicit Physical Sensor for Egocentric Grasp Pressure Estimation

Import ICLR 2027 submission 2JjyykgxIM: 8 notes

@openreview[bot] · 2026-11-22 20:18 UTC · 69badd10e003

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,19 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "2JjyykgxIM"
+ }
+ ],
+ "title": "Hand Kinematics as an Implicit Physical Sensor for Egocentric Grasp Pressure Estimation",
+ "authors": [],
+ "abstract": "Estimating grasp pressure from egocentric video is a partially observed and underdetermined inverse contact problem, as deformation at the contact interface is often occluded. Existing methods rely mainly on RGB appearance and overlook hand motion as a source of physical evidence. We present KIPS, which treats hand kinematics as an implicit physical sensor. During stable grasp transport, hand and object motion are mechanically coupled, making the recovered hand trajectory informative about the contact load required to support and accelerate the object. KIPS represents motion through displacement, velocity, and acceleration at multiple granularities, then learns an implicit mapping from these observations to dense sensor responses. RGB features optionally condition the model with complementary appearance cues. Across EgoTactile and OpenTouch, KIPS without direct RGB appearance conditioning outperforms appearance-based baselines on most metrics, while adding RGB features yields further improvements. Motion-stratified analysis shows that stronger motion coincides with larger relative pressure changes and smaller gains from RGB, underscoring the value of kinematic evidence in dynamic interactions.",
+ "year": 2027,
+ "venue": "ICLR 2027 (under review)",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/2jjyykgxim/forms.json added

+++ b/reviews/openreview/2jjyykgxim/forms.json
@@ -0,0 +1,183 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "additional_comments_on_reviewer_discussion",
+ "label": "Reviewer discussion",
+ "type": "text"
+ },
+ {
+ "key": "recommendation",
+ "label": "Recommendation",
+ "type": "choice"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "soundness",
+ "presentation",
+ "informativeness"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "soundness",
+ "label": "Soundness",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "presentation",
+ "label": "Presentation",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "informativeness",
+ "label": "Informativeness",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "paper_summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "critical_strengths",
+ "label": "Strengths",
+ "type": "text"
+ },
+ {
+ "key": "critical_weaknesses",
+ "label": "Weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions_for_authors",
+ "label": "Questions for the authors",
+ "type": "text"
+ },
+ {
+ "key": "flag_for_ethics_review",
+ "label": "Flag for ethics review",
+ "type": "choice",
+ "omitWhen": [
+ "No",
+ "No ethics review needed."
+ ]
+ },
+ {
+ "key": "details_of_ethics_concerns",
+ "label": "Ethics concerns",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2jjyykgxim/notes/bahgymuo8a.json added

+++ b/reviews/openreview/2jjyykgxim/notes/bahgymuo8a.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "baHgyMuO8A",
+ "replyTo": "TQRKdqCxkO",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "We thank the reviewer for the positive assessment of KIPS' interesting empirical findings and explicit modeling. We address the key concerns point by point below.",
+ "comment": "**Q1. Additional input ablations**\n\nWe provide more detailed input ablations on EgoTactile and OpenTouch below.\n\n**Table 1. Input ablations on EgoTactile (gloved object held-out).**\n\n| Input | MAE ↓ | CoP ↓ | V-IoU ↑ | C-IoU ↑ |\n| --- | --- | --- | --- | --- |\n| θ only | 2.961 | 3.249 | 0.449 | 0.520 |\n| θ + velocity | 2.811 | 3.070 | 0.452 | 0.526 |\n| θ + acceleration | 2.737 | 3.011 | 0.453 | 0.531 |\n| KIPS-K (full) | 2.639 | 2.946 | 0.460 | 0.546 |\n\n**Table 2. Input ablations on OpenTouch.**\n\n| Input | MAE ↓ | RMSE ↓ | NRMSE ↓ | CoP ↓ |\n| --- | --- | --- | --- | --- |\n| θ only | 1.625 | 4.391 | 9.17 | 1.344 |\n| θ + velocity | 1.546 | 4.154 | 8.67 | 1.299 |\n| θ + acceleration | 1.517 | 4.079 | 8.52 | 1.281 |\n| KIPS-K (full) | 1.420 | 3.760 | 7.85 | 1.193 |\n\nThese ablations examine the contributions of joint configuration θ and explicit motion derivatives by comparing θ alone, θ with velocity, and θ with acceleration. We keep the input dimensionality and network architecture unchanged, setting unused feature channels to zero during both training and evaluation. Explicit velocity and acceleration make these dynamics directly available to the network and improve performance on both datasets.\n\n**Q2. Statistical interpretation **\n\nThe two columns in Table 4 measure different quantities. The adjusted-MAE analysis uses regression to examine the association between acceleration and absolute error while controlling for GT pressure, contact state, and clip-level differences. On EgoTactile, the adjusted change is −28.9% (95% CI [−37.8%, −19.2%]), indicating that the negative association persists after these controls.\n\nNMAE instead divides the mean MAE within each acceleration group by that group's mean GT pressure, then compares the highest and lowest groups. Its confidence interval is estimated using 1000 clip-level bootstrap resamples: we sample clips with replacement, retain all their frames, reconstruct the acceleration groups, and recompute the relative NMAE change. On EgoTactile, the pressure-normalized difference has weaker statistical support under fine-grained grouping and is sensitive to the resampled clip composition, yielding a confidence interval that includes zero [−14.8%, +5.6%]. The negative association also holds within all five pressure strata on EgoTactile. On OpenTouch, the normalized change is −40.2% (95% CI [−47.9%, −31.5%]), providing clearer evidence that the association persists after pressure normalization.\n\n\nWe additionally report two exploratory sensitivity analyses: a coarser quartile comparison and a continuous acceleration model. The quartile analysis retains the original group-level NMAE definition. The continuous model analyzes log-normalized frame error while controlling for pressure, contact state, and clip fixed effects. These analyses provide complementary evidence for a negative association under coarser grouping and continuous modeling.\n\n**Table 3. Pressure-normalized analyses on EgoTactile.**\n\n| Analysis | Estimated change | 95% CI |\n| --- | ---: | --- |\n| Quartile grouping | −8.98% | [−15.75%, −1.10%] |\n| Continuous model: 25th to 75th Acc. percentile | −14.95% | [−20.04%, −9.59%] |\n\n**Q3. Visual dependence**\n\nKIPS takes hand motion states and, optionally direct RGB features as inputs. When hand motion states are unavailable, our pipeline relies on HaWoR to recover hand trajectories from RGB video. KIPS examines how motion states and visual features contribute to grasp-pressure estimation. In privacy- or bandwidth-constrained applications, mobile devices could provide more accurate motion trajectories, with trajectories transmitted or stored downstream and RGB data shared selectively according to application requirements. We thank the reviewer for the suggestions and will clarify the scope of our claims regarding visual features and evaluation metrics in the revision."
+ },
+ "createdAt": "2026-11-12T16:15:58.053Z",
+ "modifiedAt": "2026-11-12T16:15:58.053Z",
+ "url": "https://openreview.net/forum?id=2JjyykgxIM&noteId=baHgyMuO8A",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2jjyykgxim/notes/c3p9vwdbuj.json added

+++ b/reviews/openreview/2jjyykgxim/notes/c3p9vwdbuj.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "C3p9VwDbuJ",
+ "replyTo": "TxIAKLVvke",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer VRVM",
+ "content": {
+ "title": "change rating to weak acceptance",
+ "comment": "Thank the author for the timely and detailed response, which addressed my concerns and improved the manuscript's completeness. I would like to change my rating to weak acceptance."
+ },
+ "createdAt": "2026-11-15T14:36:12.270Z",
+ "modifiedAt": "2026-11-15T14:36:12.270Z",
+ "url": "https://openreview.net/forum?id=2JjyykgxIM&noteId=C3p9VwDbuJ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2jjyykgxim/notes/qgfuq9irnv.json added

+++ b/reviews/openreview/2jjyykgxim/notes/qgfuq9irnv.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "qGfuQ9iRNV",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer VRVM",
+ "content": {
+ "paper_summary": "KIPS estimates dense grasp pressure from hand trajectories recovered from egocentric video. It combines wrist and joint kinematics, learned acceleration prototypes, phase-structured temporal modeling, and anatomical pressure decoding, with optional RGB conditioning. Experiments on EgoTactile and OpenTouch show strong pressure-prediction results, with additional analyses of transfer, motion regimes, robustness, and limited-lookahead inference. The paper treats pressure recovery as conditional prediction and acknowledges that kinematics does not uniquely determine contact forces.",
+ "presentation": 2,
+ "informativeness": 3,
+ "soundness": 3,
+ "critical_strengths": "1. KIPS-K reduces EgoTactile MAE from 3.400 to 2.639 on object-held-out evaluation and from 5.800 to 3.021 on subject-held-out evaluation relative to EgoPressureDiff (Table 1). OpenTouch and bare-hand transfer provide further evidence that recovered hand motion is useful for pressure estimation.\n\n2. Table 4 controls for pressure magnitude and clip differences; Table 6 includes an RGB-only comparison on OpenTouch; Figure 5 studies derivatives and temporal modeling. These strengthen the empirical case beyond raw motion–error correlations. The paper also acknowledges limitations, including weaker zero-shot spatial overlap.",
+ "critical_weaknesses": "1. Modality attribution remains incomplete on EgoTactile. The RGB-only KIPS comparison is reported only on OpenTouch. On EgoTactile, the principal comparisons involve different model families, so the gains cannot be cleanly attributed to the input modality rather than temporal modeling and decoding. Extending the existing RGB-only control to one representative EgoTactile split would directly strengthen the central claim. Figure 5 is helpful, but the precise scope of “w/o Vel. and Acc.” also needs clarification before interpreting it as a configuration-versus-dynamics comparison.\n\n2. Baseline coverage and comparison details need clearer justification. [HOPE (Jeon et al., 2026)](https://arxiv.org/abs/2608.06192) is cited and directly relevant to video-and-pose pressure estimation, yet the OpenTouch comparison in Table 3 includes only an adapted HACO baseline. The relationship to this closer prior work deserves explanation. Section 4.1 also leaves the provenance of baseline numbers unclear, while Appendix A.3 does not define NRMSE or explain OpenTouch CoP in millimeters. These gaps limit assessment of both comparative performance and contribution.",
+ "questions_for_authors": "1. Could you report the existing KIPS-RGB variant on the EgoTactile object-held-out split, matching temporal context and training settings, and explain the architectural changes needed to remove kinematic inputs?\n2. In Figure 5, does “w/o Vel. and Acc.” also remove wrist derivatives, Δv/Δa, acceleration-prototype assignments, and the acceleration-conditioned spatial prior? Please specify the retained inputs and report the absolute results of this existing ablation.\n3. Why is HOPE omitted from the OpenTouch comparison, and are its task and evaluation protocol compatible? An explanation of relevant differences is sufficient where direct comparison is inappropriate. Please also identify reproduced versus previously reported baseline numbers and clarify the CoP/NRMSE definitions used for the comparisons.",
+ "flag_for_ethics_review": "No",
+ "rating": 3,
+ "confidence": 4
+ },
+ "createdAt": "2026-10-21T08:38:36.725Z",
+ "modifiedAt": "2026-11-15T14:30:02.479Z",
+ "url": "https://openreview.net/forum?id=2JjyykgxIM&noteId=qGfuQ9iRNV",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2jjyykgxim/notes/tqrkdqcxko.json added

+++ b/reviews/openreview/2jjyykgxim/notes/tqrkdqcxko.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "TQRKdqCxkO",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer GVAS",
+ "content": {
+ "paper_summary": "This paper proposes KIPS, a kinematics-led estimator of dense grasp pressure from egocentric video. Recovered MANO trajectories are represented through joint configuration, displacement, velocity, acceleration, and wrist-level state. An acceleration dictionary, graph encoding, phase-structured temporal module, and location-specific decoder produce pressure predictions, optionally conditioned on RGB features. The paper reports improvements on EgoTactile and OpenTouch and analyzes how prediction accuracy varies with motion. I view the work primarily as evidence for useful conditional prediction from recovered kinematics, rather than direct identification of dense contact mechanics.",
+ "presentation": 2,
+ "informativeness": 2,
+ "soundness": 2,
+ "critical_strengths": "The core empirical result is interesting: pressure magnitude can be predicted well without direct RGB conditioning at the pressure head. On the two EgoTactile gloved splits, KIPS-K obtains MAEs of 2.639 and 3.021 versus 3.400 and 5.800 for EgoPressureDiff. OpenTouch provides complementary support. The architecture makes anatomical location and interaction phase explicit, and the ablations examine several relevant components.",
+ "critical_weaknesses": "The physical interpretation remains broader than what the observational evidence establishes. Kinematic inputs include static configuration: palm-relative positions and the wrist auxiliary state contain orientation, MANO pose, and gravity information. Therefore, the kinematics-only comparison does not isolate acceleration-based mechanical evidence from pose, grasp category, or temporal regularity. It is also not an entirely vision-free pipeline, since the trajectories come from HaWoR. More tightly matched static-pose and derivative controls would clarify which information explains the gains.\n\nThe results contain important metric tradeoffs. KIPS-K improves MAE and volumetric overlap but has lower contact IoU than EgoPressureDiff on both gloved splits: 0.546 versus 0.563 and 0.453 versus 0.512. Bare-hand zero-shot transfer similarly improves magnitude while retaining lower spatial overlaps. These results support the usefulness of kinematics but not its universal sufficiency for contact localization. The RGB-conditioned model helps resolve this limitation, which is an informative finding rather than a nuisance exception.",
+ "questions_for_authors": "1. Can you provide capacity- and context-matched pose-only, pose-plus-velocity, and pose-plus-acceleration comparisons on both pressure benchmarks?\n\n2. How should the significant adjusted absolute-error association be reconciled with the EgoTactile normalized interval crossing zero?",
+ "flag_for_ethics_review": "No",
+ "rating": 3,
+ "confidence": 3
+ },
+ "createdAt": "2026-10-24T01:43:29.748Z",
+ "modifiedAt": "2026-11-06T12:29:56.250Z",
+ "url": "https://openreview.net/forum?id=2JjyykgxIM&noteId=TQRKdqCxkO",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2jjyykgxim/notes/tvsrbjvkyb.json added

+++ b/reviews/openreview/2jjyykgxim/notes/tvsrbjvkyb.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "TVSRBJVkYB",
+ "replyTo": "xED3aff6m3",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "We thank the reviewer for the positive assessment of KIPS' well-motivated architecture and informative experiments. We address the key concerns point by point below.",
+ "comment": "**Q1. Similar grasps**\n\nWe selected frames showing similar grasps of bottle-like objects in EgoTactile, using the dataset-provided mass labels to organize the comparisons.\n\n**Table 1. Pressure differences across selected object pairs.**\n\n| Participant | Object change | Mass difference (g) | GT pressure difference | K-only | K+RGB |\n| --- | --- | ---: | ---: | ---: | ---: |\n| p007 | Coca-Cola 500 mL → Schweppes 555 mL | 69 | +1.012 | +0.734 | +0.946 |\n| p011 | Nongfu Spring 550 mL, green label → red label | 0 | +2.859 | +0.063 | +2.326 |\n| p007 | Pepsi 330 mL → Pepsi 900 mL | 597 | +3.411 | +2.288 | +2.902 |\n\nAcross these three selected pairs, the fusion model predicts pressure differences closer to the ground truth, covering both appearance changes at equal mass and containers with different masses.\n\n**Q2. Trajectory quality**\n\nTrajectory quality affects KIPS performance. We added trajectory perturbation experiments on OpenTouch. RGB mitigates degradation under sustained freezing and missing trajectories, while the two models respond similarly to single-frame jumps. Δ denotes the change relative to each model's own clean-input result.\n\n**Table 2. Changes under trajectory perturbations.**\n\n| Trajectory perturbation | Model | ΔMAE ↓ | ΔCoP ↓ |\n| --- | --- | ---: | ---: |\n| 4× single-frame jump | K-only | +0.00509 | +0.00253 |\n| 4× single-frame jump | K+RGB | +0.00507 | +0.00259 |\n| 32-frame freeze | K-only | +0.05978 | +0.05453 |\n| 32-frame freeze | K+RGB | +0.03926 | +0.03595 |\n| 32-frame dropout with interpolation | K-only | +0.11549 | +0.10631 |\n| 32-frame dropout with interpolation | K+RGB | +0.05027 | +0.02979 |\n\nFor frames with failed detections, we use temporal trajectory interpolation and the HaWoR completion module, marking completed frames accordingly. KIPS examines how motion states and visual features contribute to everyday grasp-pressure estimation. In privacy- or bandwidth-constrained applications, sensor-derived trajectories from mobile devices can provide an alternative motion input when available.\n\n**Q3. Occlusion**\n\nWe compared selected frames with different visibility conditions on EgoTactile and OpenTouch. Within these samples, estimation errors are lower when the hand is more visible, and RGB further improves the reported metrics in both visibility groups.\n\n**Table 3. Selected visibility groups on EgoTactile.**\n\n| Visibility condition | KIPS-K MAE ↓ | KIPS-K+RGB MAE ↓ | KIPS-K IoU ↑ | KIPS-K+RGB IoU ↑ |\n| --- | ---: | ---: | ---: | ---: |\n| Mostly visible | 3.4681 | 3.0114 | 0.6211 | 0.6585 |\n| Partially visible | 7.5230 | 6.6394 | 0.5122 | 0.5891 |\n\n**Table 4. Selected visibility groups on OpenTouch.**\n\n| Visibility condition | KIPS-K MAE ↓ | KIPS-K+RGB MAE ↓ |\n| --- | ---: | ---: |\n| Mostly visible | 1.5416 | 1.4490 |\n| Partially visible | 2.6988 | 2.4730 |\n\n**Q4. Local joint information**\n\nPSTD constructs a global temporal state from pooled joint representations, while the pressure decoder retains access to joint-specific graph features. Local joint information therefore remains available to dense pressure prediction. To evaluate localized interactions, we identify a finger as active when at least three taxels in its region exceed the pressure threshold.\n\n**Table 5. Regional accuracy under single-finger contact.**\n\n| Evaluation | Contact | KIPS-K MAE ↓ | KIPS-K+RGB MAE ↓ | KIPS-K IoU ↑ | KIPS-K+RGB IoU ↑ |\n| --- | --- | ---: | ---: | ---: | ---: |\n| Object held-out | Single-finger contact | 4.0320 | 3.2483 | 0.4604 | 0.5166 |\n| Subject held-out | Single-finger contact | 5.2728 | 3.5424 | 0.3881 | 0.5597 |\n\nThese results demonstrate the existing architecture's ability to predict localized pressure distributions. On both gloved protocols, RGB reduces pressure MAE and improves contact IoU within the active-finger region, showing that its complementary benefits extend to localized interactions.\n\nWe also evaluated a per-finger temporal pooling variant on the EgoTactile object held-out split.\n\n**Table 6. Global versus per-finger temporal pooling.**\n\n| Model | MAE ↓ | CoP ↓ | V-IoU ↑ | C-IoU ↑ |\n| --- | ---: | ---: | ---: | ---: |\n| Per-finger pooling variant | 2.6734 | **2.8399** | **0.4636** | 0.5451 |\n| KIPS-K | **2.6386** | 2.9456 | 0.4602 | **0.5464** |\n\nPer-finger temporal pooling improves CoP and V-IoU but worsens MAE and C-IoU, with modest overall differences."
+ },
+ "createdAt": "2026-11-12T16:16:06.999Z",
+ "modifiedAt": "2026-11-12T16:18:38.497Z",
+ "url": "https://openreview.net/forum?id=2JjyykgxIM&noteId=TVSRBJVkYB",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2jjyykgxim/notes/txiaklvvke.json added

+++ b/reviews/openreview/2jjyykgxim/notes/txiaklvvke.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "TxIAKLVvke",
+ "replyTo": "qGfuQ9iRNV",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "We thank the reviewer for recognizing our extensive experimental results and thorough supporting analyses. We address the key concerns point by point below.",
+ "comment": "**Q1. Comparison with HOPE**\n\nHOPE's code was unavailable at submission, preventing a direct comparison at that time. We adapt and retrain HOPE on our dataset splits, training its pressure-related modules. We retain HOPE's original window length and stride while matching KIPS' training epochs, valid evaluation locations, pressure units, and evaluator.\n\n**Table 1. Object held-out comparison.**\n\n| Model | MAE ↓ | CoP ↓ | V-IoU ↑ | C-IoU ↑ |\n| --- | ---: | ---: | ---: | ---: |\n| HOPE | 4.1149 | 4.0281 | 0.3874 | 0.3948 |\n| KIPS-K | 2.639 | 2.946 | 0.460 | 0.546 |\n| KIPS-K+RGB | **2.302** | **2.491** | **0.524** | **0.604** |\n\n**Table 2. Subject held-out comparison.**\n\n| Model | MAE ↓ | CoP ↓ | V-IoU ↑ | C-IoU ↑ |\n| --- | ---: | ---: | ---: | ---: |\n| HOPE | 3.1035 | 2.7207 | 0.4181 | 0.4594 |\n| KIPS-K | 3.021 | **2.516** | 0.413 | 0.453 |\n| KIPS-K+RGB | **2.569** | 2.521 | **0.461** | **0.517** |\n\n**Table 3. Bare-hand zero-shot transfer.**\n\n| Model | MAE ↓ | CoP ↓ | V-IoU ↑ | C-IoU ↑ |\n| --- | ---: | ---: | ---: | ---: |\n| HOPE | 3.7639 | 3.3232 | **0.3877** | **0.4271** |\n| KIPS-K | 3.502 | 3.234 | 0.310 | 0.423 |\n| KIPS-K+RGB | **3.108** | **2.482** | 0.312 | 0.409 |\n\n**Table 4. Bare-hand fine-tuning.**\n\n| Model | MAE ↓ | CoP ↓ | V-IoU ↑ | C-IoU ↑ |\n| --- | ---: | ---: | ---: | ---: |\n| HOPE | 3.5441 | 3.8876 | 0.4374 | 0.4846 |\n| KIPS-K | 2.330 | 2.574 | 0.529 | 0.598 |\n| KIPS-K+RGB | **2.153** | **2.572** | **0.563** | **0.620** |\n\n**Table 5. OpenTouch comparison.**\n\n| Method | MAE ↓ | RMSE ↓ | CoP ↓ |\n| --- | ---: | ---: | ---: |\n| HOPE | 1.8982 | 3.8157 | 1.3150 |\n| KIPS-K | 1.420 | 3.760 | 1.193 |\n| KIPS-K+RGB | **1.369** | **3.668** | **1.162** |\n\nHOPE achieves higher V-IoU and C-IoU under bare-hand zero-shot transfer. KIPS-K+RGB outperforms HOPE on other reported metrics and protocols.\n\n**Q2. Baseline and metric definitions**\n\nHardware constraints prevented us from retraining EgoPressureDiff, so we report its published results under the same evaluation protocol. HACO is initialized from its released pretrained weights, augmented with a pressure prediction head, and fine-tuned on the corresponding training split.\n\nFor OpenTouch, NRMSE is RMSE divided by the mean ground-truth pressure over valid evaluation locations, multiplied by 100 when reported as a percentage. \n\nCoP is computed separately within the five finger regions and the palm. We calculate pressure-weighted predicted and ground-truth centers, measure their Euclidean distance, and aggregate using the specified region and frame rules. OpenTouch uses metric coordinates from the same template mesh, converted to millimetres. EgoTactile follows the official sensor-grid coordinate units. We will identify the source of each baseline result and clarify these metric definitions in the revision.\n\n**Q3. Ablations**\n\nThe velocity/acceleration ablation removes explicit wrist- and joint-level velocities and accelerations, together with the associated prototype dictionary and spatial prior.\n\nWe additionally provide finer-grained input ablations separating joint configuration θ, velocity, and acceleration. These keep the network parameter count unchanged, with unused input channels set to zero. The prototype dictionary modules remain. Without acceleration input, prototype retrieval becomes input-independent and yields a static learnable spatial prior. Explicit motion derivatives improve performance on both datasets.\n\n**Table 6. EgoTactile input ablations.**\n\n| Input | MAE ↓ | CoP ↓ | V-IoU ↑ | C-IoU ↑ |\n| --- | --- | --- | --- | --- |\n| θ only | 2.961 | 3.249 | 0.449 | 0.520 |\n| θ + velocity | 2.811 | 3.070 | 0.452 | 0.526 |\n| θ + acceleration | 2.737 | 3.011 | 0.453 | 0.531 |\n| KIPS-K (full) | 2.639 | 2.946 | 0.460 | 0.546 |\n\n**Table 7. OpenTouch input ablations.**\n\n| Input | MAE ↓ | RMSE ↓ | NRMSE ↓ | CoP ↓ |\n| --- | --- | --- | --- | --- |\n| θ only | 1.625 | 4.391 | 9.17 | 1.344 |\n| θ + velocity | 1.546 | 4.154 | 8.67 | 1.299 |\n| θ + acceleration | 1.517 | 4.079 | 8.52 | 1.281 |\n| KIPS-K (full) | 1.420 | 3.760 | 7.85 | 1.193 |\n\n**Q4. RGB-only comparison**\n\nWe add an RGB-only variant that removes kinematic inputs and their dedicated processing components, including the acceleration-conditioned spatial prior and the parts for explicit joint- and wrist-level velocities and accelerations. Phase states are predicted by RGB temporal features. Combining RGB and motion states improves most metrics. OpenTouch with lower trajectory noise enables more pronounced gains.\n\n**Table 8. RGB-only: gloved.**\n\n| Gloved | MAE ↓ | CoP ↓ | V-IoU ↑ | C-IoU ↑ |\n| --- | ---: | ---: | ---: | ---: |\n| RGB | 2.6001 | 2.9242 | 0.5062 | 0.5631 |\n| KIPS-K+RGB | 2.3024 | 2.4908 | 0.5238 | 0.6043 |\n\n**Table 9. RGB-only: bare-hand.**\n\n| Bare-hand | MAE ↓ | CoP ↓ | V-IoU ↑ | C-IoU ↑ |\n| --- | ---: | ---: | ---: | ---: |\n| RGB | 3.4283 | 3.4500 | 0.3121 | 0.3885 |\n| KIPS-K+RGB | 3.1077 | 2.4815 | 0.3118 | 0.4090 |"
+ },
+ "createdAt": "2026-11-12T16:16:25.235Z",
+ "modifiedAt": "2026-11-12T16:18:57.171Z",
+ "url": "https://openreview.net/forum?id=2JjyykgxIM&noteId=TxIAKLVvke",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2jjyykgxim/notes/vjjqj000dp.json added

+++ b/reviews/openreview/2jjyykgxim/notes/vjjqj000dp.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "vJJQJ000Dp",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Area Chair and Reviewers,\n\nWe sincerely thank the Area Chair and reviewers for their time, constructive feedback, and careful evaluation of our work. We have provided detailed point-by-point responses and substantial additional experiments addressing the major concerns. If you have any remaining concerns, we would be happy to discuss them further.\n\nThank you again for your time and consideration.\n\nBest regards,\n\nThe Authors"
+ },
+ "createdAt": "2026-11-19T09:53:57.491Z",
+ "modifiedAt": "2026-11-19T09:53:57.491Z",
+ "url": "https://openreview.net/forum?id=2JjyykgxIM&noteId=vJJQJ000Dp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2jjyykgxim/notes/xed3aff6m3.json added

+++ b/reviews/openreview/2jjyykgxim/notes/xed3aff6m3.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "xED3aff6m3",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer DLxn",
+ "content": {
+ "paper_summary": "The paper presents a method for grasp pressure estimation based on hand kinematics. Given an input\nvideo, the model, named KIPS, uses an off-the-shelf hand trajectory estimator to get the hand motion,\nfrom which it predicts, with temporal modelling, dense grasp pressure distributions and contact\nprobabilities. Additionally, conditioning the temporal state on frozen RGB features generally improves\nthe performance further. The work shows effectiveness of hand kinematics and trajectory on the grasp\npressure prediction, by outperforming previous appearance-based baselines.",
+ "presentation": 3,
+ "informativeness": 2,
+ "soundness": 2,
+ "critical_strengths": "Strength 1: The paper presents promising results with modeling the pressure based on the hand motion.\nThe 3 parts of the model (IKR, PSTD, IGPD) are nicely motivated and constructed. The evaluation shows\nthat KIPS outperforms baselines on most metrics. Accurate hand motion representations can provide a\nuseful abstraction of complex egocentric scenes, reducing the amount of irrelevant visual information that\nRGB-based models need to process.\nStrength 2: Ablation analysis (including modelling without temporal aggregation and using only wrist\ndynamics) on Figure 5 support the architecture choices and can provide beneficial insights for future\nworks to understand the impact of main components of KIPS.",
+ "critical_weaknesses": "Weakness 1: Limitations of using (only) hand kinematics for grasp pressure estimation.\nKIPS formulation could overlook differences in the object types and properties and potential useful scene\ncues. While KIPS shows promising results, it would be interesting to see how well it performs on similar\nobjects that require different pressure to interact for the same grasp/action type. One interesting\nexperiment would be to analyze the distributions of predicted grasps pressures across different objects for\nthe same grasp / action type, to observe if the model predicts similar pressure patterns despite actual\ndifferences. This could be evaluated on objects with similar appearances and dimensions but different\nphysical properties.\nFurthermore, the performance of the method is quite limited by the accuracy of the hand trajectory. It\nremains unclear if there would need to be some adaptations to severe tracking failures or large outliers\nduring the sequence window. Even with conditioning on RGB video in PSTD, it is unclear if the model\ncould recover from outliers in the hand trajectory estimation.\nWeakness 2: PSTD part of the model KIPS receives a joint-averaged representation on which the\ntemporal modelling is performed (rather than individually modeling over separate joints). This could\npotentially lead to some joint-specific temporal information being lost, which is important for dense\npressure prediction. It would be interesting to evaluate the model on the parts of the dataset, where only\nspecific joints (and not full hand) are involved in interaction, with and without RGB conditioning.",
+ "questions_for_authors": "Question 1: Could the authors analyze the distribution of predicted and ground truth grasp pressures\nacross different objects for the same grasp / action type? Interesting follow-up experiment would be\nrepeating this analysis for object groups with similar appearances and dimensions, but different pressure\nrequirements.\nQuestion 2: For the extraction of hand trajectories, KIPS relies on HaWoR. How much does the accuracy\nof HaWoR influence KIPS performance? Does this impact differ between in-the-lab and in-the-wild\nsettings?\nQuestion 3: How well do the models (KIPS-K, KIPS-K+RGB) perform under different occlusion\nconditions?",
+ "flag_for_ethics_review": "No",
+ "rating": 3,
+ "confidence": 3
+ },
+ "createdAt": "2026-10-21T19:55:14.075Z",
+ "modifiedAt": "2026-11-06T12:29:57.530Z",
+ "url": "https://openreview.net/forum?id=2JjyykgxIM&noteId=xED3aff6m3",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2jjyykgxim/submission.json added

+++ b/reviews/openreview/2jjyykgxim/submission.json
@@ -0,0 +1,17 @@
+{
+ "schema": "submission/1",
+ "id": "2JjyykgxIM",
+ "venue": {
+ "id": "ICLR.cc/2027/Conference",
+ "name": "ICLR 2027",
+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference"
+ },
+ "number": 35679,
+ "keywords": [
+ "Egocentric Vision",
+ "Hand Kinematics",
+ "Grasp Pressure Estimation"
+ ],
+ "url": "https://openreview.net/forum?id=2JjyykgxIM",
+ "license": "CC-BY-4.0"
+}

versions/v_bw35u9ad.json added

+++ b/versions/v_bw35u9ad.json
@@ -0,0 +1,21 @@
+{
+ "date": "2026-09-18",
+ "kind": "submitted",
+ "label": "ICLR 2027",
+ "submissions": [
+ {
+ "venue": "ICLR 2027",
+ "status": "under_review",
+ "number": 35679,
+ "url": "https://openreview.net/forum?id=2JjyykgxIM",
+ "reviews": "openreview/2jjyykgxim",
+ "evidence": [
+ "https://openreview.net/forum?id=2JjyykgxIM"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=2JjyykgxIM",
+ "evidence": [
+ "https://openreview.net/forum?id=2JjyykgxIM"
+ ]
+}