potentialpaper

Biomechanically Grounded 3D Human Mesh Reconstruction via Spatio-Temporal Adapters

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 19:50 UTC · 4451f30b0aaa ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "CULsb9UoYq"
- }
- ],
- "title": "Biomechanically Grounded 3D Human Mesh Reconstruction via Spatio-Temporal Adapters",
- "authors": [],
- "abstract": "Recovering 3D human pose and shape from monocular input is central to computer vision, yet for anatomy-aware applications such as clinical motion analysis and sports biomechanics, geometric accuracy alone is insufficient: reconstructions must also be biomechanically valid. Most methods build on SMPL, whose joints are unconstrained ball-and-sockets and often produce physically impossible rotations. The SKEL model instead provides a physiologically grounded skeleton that is valid by construction, but learning to predict SKEL has remained limited by the scarcity of SKEL annotations.\nWe introduce BioHMR, a SKEL-based framework that is simultaneously scalable, temporally coherent, and efficient. BioHMR reconstructs in an explicit skeletal latent space: a compact set of learnable joint tokens, one per SKEL joint, gathers evidence from image patches, reasons over the SKEL kinematic tree, and tracks each joint through time within a Vision Transformer, giving temporally coherent reconstruction without dense spatio-temporal attention. To overcome the annotation scarcity, a lightweight SMPL-to-SKEL mapper, trained by mesh consistency, generates pseudo-SKEL supervision from abundant SMPL annotations roughly $300\\times$ faster than prior conversion, making large-scale SKEL training practical. The same joint-token attention drives an optional pose-aware patch pruning for a tunable compute-accuracy trade-off at inference.\nAcross COCO, LSP-Extended, 3DPW, and MOYO, BioHMR attains state-of-the-art accuracy, efficiency, and temporal coherence among SKEL-based methods, with the lowest MPJPE on both 3DPW and MOYO and 2D accuracy on par with the strongest SMPL-based baselines. Moreover, its reconstructions stay biomechanically valid by construction, cutting per-joint violation rates on MOYO from 44--56\\% for SMPL-based HMR2.0 to 0--4\\%.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "948bdbf5-ff48-464c-a84a-580a778ed2a7"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "Biomechanically Grounded 3D Human Mesh Reconstruction via Spatio-Temporal Adapters",
+ "authors": [],
+ "abstract": "Recovering 3D human pose and shape from monocular input is central to computer vision, yet for anatomy-aware applications such as clinical motion analysis and sports biomechanics, geometric accuracy alone is insufficient: reconstructions must also be biomechanically valid. Most methods build on SMPL, whose joints are unconstrained ball-and-sockets and often produce physically impossible rotations. The SKEL model instead provides a physiologically grounded skeleton that is valid by construction, but learning to predict SKEL has remained limited by the scarcity of SKEL annotations.\nWe introduce BioHMR, a SKEL-based framework that is simultaneously scalable, temporally coherent, and efficient. BioHMR reconstructs in an explicit skeletal latent space: a compact set of learnable joint tokens, one per SKEL joint, gathers evidence from image patches, reasons over the SKEL kinematic tree, and tracks each joint through time within a Vision Transformer, giving temporally coherent reconstruction without dense spatio-temporal attention. To overcome the annotation scarcity, a lightweight SMPL-to-SKEL mapper, trained by mesh consistency, generates pseudo-SKEL supervision from abundant SMPL annotations roughly $300\\times$ faster than prior conversion, making large-scale SKEL training practical. The same joint-token attention drives an optional pose-aware patch pruning for a tunable compute-accuracy trade-off at inference.\nAcross COCO, LSP-Extended, 3DPW, and MOYO, BioHMR attains state-of-the-art accuracy, efficiency, and temporal coherence among SKEL-based methods, with the lowest MPJPE on both 3DPW and MOYO and 2D accuracy on par with the strongest SMPL-based baselines. Moreover, its reconstructions stay biomechanically valid by construction, cutting per-joint violation rates on MOYO from 44--56\\% for SMPL-based HMR2.0 to 0--4\\%.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}