potentialpaper

Correct Before It Drifts: Counterfactual-Guided Intervention to Mitigate Hallucinations in Radiology Report Generation

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 19:52 UTC · 49aaf06bf930 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "g8ODF0GTa0"
- }
- ],
- "title": "Correct Before It Drifts: Counterfactual-Guided Intervention to Mitigate Hallucinations in Radiology Report Generation",
- "authors": [],
- "abstract": "Factual errors in radiology reports are usually evaluated after generation, yet they arise sequentially: once an autoregressive generator commits to an image-inconsistent statement, that partial report becomes context for all subsequent sentences. We study this intermediate failure mode as partial-report drift and ask a more targeted question: when an image-grounded correction is available, should it be applied now, before the remaining report is generated? We introduce Correct Before It Drifts, a three-stage intervention framework that does not update the report-generator parameters. First, Grounded Error Detection verifies newly generated clinical claims against the radiograph and proposes only minimal image-supported repairs. Second, Counterfactual Preference Learning constructs corrected and unchanged continuations from the same partial report and uses their complete-report outcomes as offline preference supervision for a lightweight shared model. Third, Online Repair Selection predicts this preference from only a short lookahead and selectively applies repairs using a validation-calibrated intervention threshold. Across MIMIC-CXR and IU-Xray, multiple report generators, and strong hallucination-mitigation baselines, the method consistently reduces report-level clinical errors and improves structured factuality while largely preserving report semantics. Process-level analyses further show that short lookahead predicts full-report preference better than local verification alone and that earlier repairs exert a larger effect on subsequent report content. These results support treating radiology hallucination mitigation as a timely decision over evolving reports rather than only a post-hoc correction problem.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "adf67661-13ce-4ede-8f29-7c06af56de03"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "Correct Before It Drifts: Counterfactual-Guided Intervention to Mitigate Hallucinations in Radiology Report Generation",
+ "authors": [],
+ "abstract": "Factual errors in radiology reports are usually evaluated after generation, yet they arise sequentially: once an autoregressive generator commits to an image-inconsistent statement, that partial report becomes context for all subsequent sentences. We study this intermediate failure mode as partial-report drift and ask a more targeted question: when an image-grounded correction is available, should it be applied now, before the remaining report is generated? We introduce Correct Before It Drifts, a three-stage intervention framework that does not update the report-generator parameters. First, Grounded Error Detection verifies newly generated clinical claims against the radiograph and proposes only minimal image-supported repairs. Second, Counterfactual Preference Learning constructs corrected and unchanged continuations from the same partial report and uses their complete-report outcomes as offline preference supervision for a lightweight shared model. Third, Online Repair Selection predicts this preference from only a short lookahead and selectively applies repairs using a validation-calibrated intervention threshold. Across MIMIC-CXR and IU-Xray, multiple report generators, and strong hallucination-mitigation baselines, the method consistently reduces report-level clinical errors and improves structured factuality while largely preserving report semantics. Process-level analyses further show that short lookahead predicts full-report preference better than local verification alone and that earlier repairs exert a larger effect on subsequent report content. These results support treating radiology hallucination mitigation as a timely decision over evolving reports rather than only a post-hoc correction problem.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}