SymBreak: Breaking the Implanted False Belief to Identify Subvisual Ischemic Changes
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 19:52 UTC · daabcc9fd1d3 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "XnKIATeewi"- }- ],- "title": "SymBreak: Breaking the Implanted False Belief to Identify Subvisual Ischemic Changes",- "authors": [],- "abstract": "Stroke is a leading cause of death and disability, and rapid diagnosis is critical to improving patient outcomes. Although non-contrast CT (NCCT) is the first-line imaging modality for suspected stroke, hyperacute ischemic changes, particularly within 4.5 hours, remain difficult to detect because of their subtle imaging manifestations. When pathological signals are extremely weak, lesion-related responses can be difficult to distinguish from the model's own background hallucinations—weak, spatially irregular lesion-like responses elicited even by negative scans. Here, we propose \\textbf{SymBreak}, a new training and inference paradigm based on false-belief implantation that organizes these otherwise unstructured background responses into a predictable pattern, thereby improving the detectability of subtle ischemic changes. During training, generative models transform unilateral ischemic samples into bilaterally symmetric counterfactual cases, implanting the false belief that \\textit{ischemic changes MUST BE symmetric between hemispheres}. During inference, background responses in non-stroke cases tend to follow this implanted symmetry, whereas genuine unilateral ischemic changes break it. We quantify this violation using the Symmetry-Breaking Index (SBI), which converts hemispheric imbalance in predicted lesion evidence into a patient-level diagnostic signal. Across five public NCCT datasets, SymBreak consistently improves patient-level discrimination over existing intensity- and lesion-size-based methods across four held-out AIS cohorts and multiple segmentation architectures. Response analyses further show that false-belief implantation substantially reduces hemispheric imbalance in non-stroke cases while preserving pronounced symmetry breaking in unilateral AIS. Together, these findings establish SymBreak as an accurate and robust approach for detecting hyperacute ischemic changes and suggest a broader weak-signal learning paradigm: deliberately structuring model background responses enables pathology to be detected through violations of the resulting structure.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "76d0deda-03ae-453e-9d05-c5468b7589f1"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "SymBreak: Breaking the Implanted False Belief to Identify Subvisual Ischemic Changes",+ "authors": [],+ "abstract": "Stroke is a leading cause of death and disability, and rapid diagnosis is critical to improving patient outcomes. Although non-contrast CT (NCCT) is the first-line imaging modality for suspected stroke, hyperacute ischemic changes, particularly within 4.5 hours, remain difficult to detect because of their subtle imaging manifestations. When pathological signals are extremely weak, lesion-related responses can be difficult to distinguish from the model's own background hallucinations—weak, spatially irregular lesion-like responses elicited even by negative scans. Here, we propose \\textbf{SymBreak}, a new training and inference paradigm based on false-belief implantation that organizes these otherwise unstructured background responses into a predictable pattern, thereby improving the detectability of subtle ischemic changes. During training, generative models transform unilateral ischemic samples into bilaterally symmetric counterfactual cases, implanting the false belief that \\textit{ischemic changes MUST BE symmetric between hemispheres}. During inference, background responses in non-stroke cases tend to follow this implanted symmetry, whereas genuine unilateral ischemic changes break it. We quantify this violation using the Symmetry-Breaking Index (SBI), which converts hemispheric imbalance in predicted lesion evidence into a patient-level diagnostic signal. Across five public NCCT datasets, SymBreak consistently improves patient-level discrimination over existing intensity- and lesion-size-based methods across four held-out AIS cohorts and multiple segmentation architectures. Response analyses further show that false-belief implantation substantially reduces hemispheric imbalance in non-stroke cases while preserving pronounced symmetry breaking in unilateral AIS. Together, these findings establish SymBreak as an accurate and robust approach for detecting hyperacute ischemic changes and suggest a broader weak-signal learning paradigm: deliberately structuring model background responses enables pathology to be detected through violations of the resulting structure.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}