potentialpaper

SymBreak: Breaking the Implanted False Belief to Identify Subvisual Ischemic Changes

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 19:52 UTC · daabcc9fd1d3 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "XnKIATeewi"
- }
- ],
- "title": "SymBreak: Breaking the Implanted False Belief to Identify Subvisual Ischemic Changes",
- "authors": [],
- "abstract": "Stroke is a leading cause of death and disability, and rapid diagnosis is critical to improving patient outcomes. Although non-contrast CT (NCCT) is the first-line imaging modality for suspected stroke, hyperacute ischemic changes, particularly within 4.5 hours, remain difficult to detect because of their subtle imaging manifestations. When pathological signals are extremely weak, lesion-related responses can be difficult to distinguish from the model's own background hallucinations—weak, spatially irregular lesion-like responses elicited even by negative scans. Here, we propose \\textbf{SymBreak}, a new training and inference paradigm based on false-belief implantation that organizes these otherwise unstructured background responses into a predictable pattern, thereby improving the detectability of subtle ischemic changes. During training, generative models transform unilateral ischemic samples into bilaterally symmetric counterfactual cases, implanting the false belief that \\textit{ischemic changes MUST BE symmetric between hemispheres}. During inference, background responses in non-stroke cases tend to follow this implanted symmetry, whereas genuine unilateral ischemic changes break it. We quantify this violation using the Symmetry-Breaking Index (SBI), which converts hemispheric imbalance in predicted lesion evidence into a patient-level diagnostic signal. Across five public NCCT datasets, SymBreak consistently improves patient-level discrimination over existing intensity- and lesion-size-based methods across four held-out AIS cohorts and multiple segmentation architectures. Response analyses further show that false-belief implantation substantially reduces hemispheric imbalance in non-stroke cases while preserving pronounced symmetry breaking in unilateral AIS. Together, these findings establish SymBreak as an accurate and robust approach for detecting hyperacute ischemic changes and suggest a broader weak-signal learning paradigm: deliberately structuring model background responses enables pathology to be detected through violations of the resulting structure.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "76d0deda-03ae-453e-9d05-c5468b7589f1"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "SymBreak: Breaking the Implanted False Belief to Identify Subvisual Ischemic Changes",
+ "authors": [],
+ "abstract": "Stroke is a leading cause of death and disability, and rapid diagnosis is critical to improving patient outcomes. Although non-contrast CT (NCCT) is the first-line imaging modality for suspected stroke, hyperacute ischemic changes, particularly within 4.5 hours, remain difficult to detect because of their subtle imaging manifestations. When pathological signals are extremely weak, lesion-related responses can be difficult to distinguish from the model's own background hallucinations—weak, spatially irregular lesion-like responses elicited even by negative scans. Here, we propose \\textbf{SymBreak}, a new training and inference paradigm based on false-belief implantation that organizes these otherwise unstructured background responses into a predictable pattern, thereby improving the detectability of subtle ischemic changes. During training, generative models transform unilateral ischemic samples into bilaterally symmetric counterfactual cases, implanting the false belief that \\textit{ischemic changes MUST BE symmetric between hemispheres}. During inference, background responses in non-stroke cases tend to follow this implanted symmetry, whereas genuine unilateral ischemic changes break it. We quantify this violation using the Symmetry-Breaking Index (SBI), which converts hemispheric imbalance in predicted lesion evidence into a patient-level diagnostic signal. Across five public NCCT datasets, SymBreak consistently improves patient-level discrimination over existing intensity- and lesion-size-based methods across four held-out AIS cohorts and multiple segmentation architectures. Response analyses further show that false-belief implantation substantially reduces hemispheric imbalance in non-stroke cases while preserving pronounced symmetry breaking in unilateral AIS. Together, these findings establish SymBreak as an accurate and robust approach for detecting hyperacute ischemic changes and suggest a broader weak-signal learning paradigm: deliberately structuring model background responses enables pathology to be detected through violations of the resulting structure.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}