potentialpaper

Pretrained Systems for Low-Data Myocardial Segmentation: Direct Versus LV-Supervised Fine-Tuning

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 19:54 UTC · 3156fc3c0128 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "3mzvLOZn53"
- }
- ],
- "title": "Pretrained Systems for Low-Data Myocardial Segmentation: Direct Versus LV-Supervised Fine-Tuning",
- "authors": [],
- "abstract": "Choosing a pretrained system is important when myocardial annotations are limited. We compare Pixio-L with Mask2Former and EchoFM with UNETR for myocardial (MYO) segmentation on CAMUS apical four-chamber (A4C) echocardiography, evaluated against official provider-supplied reference annotations. Pixio-L is a released student distilled from the web-scale Pixio-5B teacher; EchoFM is pretrained on echocardiographic videos. Each system starts from its released encoder weights and is trained either directly on MYO or first on EchoNet-Dynamic A4C left ventricular (LV) cavity segmentation and then on MYO. Under full fine-tuning, across target-training patient fractions of 5%, 10%, 25%, 50%, and 100% and three training seeds, Pixio-L achieves higher mean MYO Dice under both routes. At 5%, the cross-system differences favoring Pixio-L are 13.38 percentage points for Direct fine-tuning and 6.52 points after LV supervision. The LV stage improves mean Dice in both systems at every fraction, with the largest gains at 5%: 2.29 points for Pixio-L and 9.15 for EchoFM. An additional 60-run frozen-MYO-encoder ablation shows that the effect of encoder updates depends on the system and initialization route. These exploratory results on one fixed patient split identify Pixio-L with Mask2Former as a strong low-data baseline and support intermediate LV supervision for both systems. Differences in architecture, input, and training recipe prevent attributing the ranking to pretraining domain or distillation alone.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "18d6204b-0b79-4e0d-8128-d0c11c7fe0d8"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "Pretrained Systems for Low-Data Myocardial Segmentation: Direct Versus LV-Supervised Fine-Tuning",
+ "authors": [],
+ "abstract": "Choosing a pretrained system is important when myocardial annotations are limited. We compare Pixio-L with Mask2Former and EchoFM with UNETR for myocardial (MYO) segmentation on CAMUS apical four-chamber (A4C) echocardiography, evaluated against official provider-supplied reference annotations. Pixio-L is a released student distilled from the web-scale Pixio-5B teacher; EchoFM is pretrained on echocardiographic videos. Each system starts from its released encoder weights and is trained either directly on MYO or first on EchoNet-Dynamic A4C left ventricular (LV) cavity segmentation and then on MYO. Under full fine-tuning, across target-training patient fractions of 5%, 10%, 25%, 50%, and 100% and three training seeds, Pixio-L achieves higher mean MYO Dice under both routes. At 5%, the cross-system differences favoring Pixio-L are 13.38 percentage points for Direct fine-tuning and 6.52 points after LV supervision. The LV stage improves mean Dice in both systems at every fraction, with the largest gains at 5%: 2.29 points for Pixio-L and 9.15 for EchoFM. An additional 60-run frozen-MYO-encoder ablation shows that the effect of encoder updates depends on the system and initialization route. These exploratory results on one fixed patient split identify Pixio-L with Mask2Former as a strong low-data baseline and support intermediate LV supervision for both systems. Differences in architecture, input, and training recipe prevent attributing the ranking to pretraining domain or distillation alone.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}