Beyond Overconfidence: Revisiting Calibration in Modern Vision Models
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 19:54 UTC · c0e3e6522e30 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "5nQ1kZteT3"- }- ],- "title": "Beyond Overconfidence: Revisiting Calibration in Modern Vision Models",- "authors": [],- "abstract": "Modern training recipes for large-scale vision models — combining aggressive augmentation, strong regularization, and web-scale pretraining — have driven substantial gains in image classification accuracy across diverse architectures and benchmarks. Their joint effect on calibration, however, remains poorly characterized. We present a large-scale calibration benchmark comprising 1218 ImageNet classifiers, a controlled ablation across 2015 ViT configurations, and a transfer evaluation on four medical imaging tasks, spanning training paradigms from classical from-scratch baselines to web-scale pretrained models with aggressive augmentation and regularization. Four findings emerge: (i) in the high-accuracy regime, modern classifiers are systematically underconfident: 98.4% of the checkpoints in the top 5% of accuracy have negative calibration bias; (ii) the training recipe, not the architecture, is the primary driver of the calibration regime, evidenced by a recipe-shaped Pareto front, consistent shifts across two architecture families, and a controlled ViT ablation; \n(iii) under severe distribution shift, in-distribution underconfidence reverses to overconfidence; while post-hoc calibration mitigates underconfidence in the in-distribution setting, this exacerbates overconfidence under severe distribution shifts; and (iv) the recipe-driven regime holds for medical imaging: modern-recipe models remain underconfident across four imaging modalities, while supervised ResNet baselines are overconfident on the same tasks. Together, these findings suggest that modern training recipes induce a structural calibration regime that can reverse under distribution shift.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "28b47e22-5953-462e-92ca-2373f33f8e8f"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "Beyond Overconfidence: Revisiting Calibration in Modern Vision Models",+ "authors": [],+ "abstract": "Modern training recipes for large-scale vision models — combining aggressive augmentation, strong regularization, and web-scale pretraining — have driven substantial gains in image classification accuracy across diverse architectures and benchmarks. Their joint effect on calibration, however, remains poorly characterized. We present a large-scale calibration benchmark comprising 1218 ImageNet classifiers, a controlled ablation across 2015 ViT configurations, and a transfer evaluation on four medical imaging tasks, spanning training paradigms from classical from-scratch baselines to web-scale pretrained models with aggressive augmentation and regularization. Four findings emerge: (i) in the high-accuracy regime, modern classifiers are systematically underconfident: 98.4% of the checkpoints in the top 5% of accuracy have negative calibration bias; (ii) the training recipe, not the architecture, is the primary driver of the calibration regime, evidenced by a recipe-shaped Pareto front, consistent shifts across two architecture families, and a controlled ViT ablation; \n(iii) under severe distribution shift, in-distribution underconfidence reverses to overconfidence; while post-hoc calibration mitigates underconfidence in the in-distribution setting, this exacerbates overconfidence under severe distribution shifts; and (iv) the recipe-driven regime holds for medical imaging: modern-recipe models remain underconfident across four imaging modalities, while supervised ResNet baselines are overconfident on the same tasks. Together, these findings suggest that modern training recipes induce a structural calibration regime that can reverse under distribution shift.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}