CryoSD: Score Distillation for Heterogeneous ab initio Reconstruction in Cryo-EM
Update ICLR 2027 submission J878EJfVsr: 1 note
@openreview[bot] · 2026-11-24 15:38 UTC · 930b43b20e3c ·
reviews/openreview/j878ejfvsr/notes/8tq497neih.json modified
+++ b/reviews/openreview/j878ejfvsr/notes/8tq497neih.json@@ -10,15 +10,15 @@"presentation": 1,"informativeness": 1,"soundness": 1,"critical_strengths": "This paper’s biggest strength is the novel approach of using score distillation sampling (SDS) to do ab initio reconstruction.",- "critical_weaknesses": "This paper has a few critical weaknesses:\n\n**(W1) I find it very hard to understand this paper**: I found this paper difficult to understand for a few reasons: one, I felt that the main ideas of the paper were not clear. In particular, I think this paper would benefit from a section that explains the key ideas at a high level, with links to the sections that provide the details of each idea. Second, at times this paper is a wall of text that is not organized into paragraphs or sections. Examples include Section 3.2, which is one huge paragraph that takes up approximately one page, and the EMPIAR-10295 results paragraph, which also takes up approximately one page. I think separating these sections into paragraphs would help highlight the different ideas. For example, on Section 3.2, it may help to separate it into subsections or paragraphs regarding preprocessing, training the diffusion model, denoising, etc. Third, the notation in the math sections is confusing. There are a lot of variables in the paper and some are not defined until significantly after they are used in equations, such as $w_s, w_a$. Perhaps the authors should include a chart explaining all the variables in the Appendix.\n\n**(W2) The empirical support for this paper is weak**: This weakness primarily comes from two sources: gaps in performance against the baselines when the comparison is fair, and unfair comparisons where CryoSD has a gap in performance.\n\nOn IgG-1D and IgG-RL, the proposed method’s performance lags behind cryoDRGN-AI’s. This can be seen from the FSC curves in Figure 3, where the red curve representing cryoDRGN-AI is always at or above the blue curve representing CryoSD. Additionally, quantitative metrics, such as FSC or FSC-AUC, are not reported, which would allow a quantitative comparison against competing methods that were not benchmarked in this paper but were benchmarked in other papers, such as cryoDRGN 2 (benchmarked in the CryoBench paper). \n\nOn the synthetic capsidHA dataset, the comparison to cryoDRGN-AI is unfair. CryoDRGN-AI assumes Gaussian white noise and could easily be adapted to handle the case of colored noise, for example by whitening the input data. CryoSD should be compared against a cryoDRGN-AI model that is adapted to colored, for example by whitening or changing the likelihood as was done for CryoSD, so we can assess how score distillation compares without the colored noise confound. \n\nOn EMPIAR-10295, I don’t think it’s fair to compare CryoSD against the result of a RELION ab initio job. A RELION ab initio job is just the initial stage of the RELION pipeline, so the results should be compared against the whole RELION pipeline, not its first stage. Second, both RELION and cryoDRGN-AI were only run on their default settings. Given that the input images represent large cages, I think it makes sense at a minimum to tune RELION’s mask diameter parameter and cryoDRGN-AI’s frequency marching parameters. Even better would be a more thorough attempt to tune the baselines on this dataset, perhaps as a grid search over each method’s most important hyperparameters. This is also possibly relevant for the capsidHA dataset as well. Additionally, it’s my experience that several runs of an ab initio algorithm may be needed to get one that converges, so multiple runs should be carried out for cryoDRGN-AI.\n\n**(W3) Missing comparisons**: I believe that the paper should compare their diffusion model-based denoising to other denoisers, with one motivation being to establish whether the gap in performance with cryoDRGN-AI on IgG-1D and IgG-RL is due to poor denoising.\n\n**Post-rebuttal updated assessment**. CryoSD proposes the new approach of using score distillation from 2D generative models to do reconstruction. However, I have the following unresolved concerns about this paper:\n\n**Empirical results on synthetic datasets**. While it is good that the authors now report FSC and FSC-AUC metrics for the CryoBench datasets they used, I have some remaining concerns on this. The first is that the FSC-AUC computation is done in a non-standard way, as the reported FSC-AUC metrics for cryoDRGN-AI are significantly higher than what the original CryoBench paper reported, making a head-to-head comparison with other papers difficult. Second, the results show that CryoSD is far from competitive on the CryoBench datasets. Third, the capsidHA comparison is confounded by the colored noise issue and does not isolate the paper's main contribution of score distillation. Given the CryoBench results, it's reasonable that the results will look quite different and have a different ordering of the methods once the colored noise confound is removed. The confound could be removed by ablating CryoSD by removing their colored noise-handling component, giving cryoDRGN-AI a proper colored noise likelihood, or by re-simulating the dataset with white noise instead of colored noise, which would be relatively cheap since there are only 25K projections. \n\n**Empirical results on experimental datasets**. It is good that the authors have clarified the scope of their method to the initial ab initio stage of the cryo-EM reconstruction pipeline. However, as noted by Reviewer NZ7w, the authors should compare their method as part of the full pipeline, which necessitates running downstream refinement for all methods and comparing the results. This would justify CryoSD as a replacement for the ab initio reconstruction steps of RELION or cryoSPARC and remove any differences in performance due to the preliminary nature of these steps in RELION and cryoSPARC.\n\n**Noise scale**. As the authors concede, there is no set procedure for setting the noise scale, and it is a manual step that relies on human judgement. While it is fine to have manual steps, the authors should include a sensitivity study of CryoSD to the noise scale because there is no reproducible way to set the noise scale. \n\n**As a result of these concerns, I firmly favor rejection.**",+ "critical_weaknesses": "This paper has a few critical weaknesses:\n\n**(W1) I find it very hard to understand this paper**: I found this paper difficult to understand for a few reasons: one, I felt that the main ideas of the paper were not clear. In particular, I think this paper would benefit from a section that explains the key ideas at a high level, with links to the sections that provide the details of each idea. Second, at times this paper is a wall of text that is not organized into paragraphs or sections. Examples include Section 3.2, which is one huge paragraph that takes up approximately one page, and the EMPIAR-10295 results paragraph, which also takes up approximately one page. I think separating these sections into paragraphs would help highlight the different ideas. For example, on Section 3.2, it may help to separate it into subsections or paragraphs regarding preprocessing, training the diffusion model, denoising, etc. Third, the notation in the math sections is confusing. There are a lot of variables in the paper and some are not defined until significantly after they are used in equations, such as $w_s, w_a$. Perhaps the authors should include a chart explaining all the variables in the Appendix.\n\n**(W2) The empirical support for this paper is weak**: This weakness primarily comes from two sources: gaps in performance against the baselines when the comparison is fair, and unfair comparisons where CryoSD has a gap in performance.\n\nOn IgG-1D and IgG-RL, the proposed method’s performance lags behind cryoDRGN-AI’s. This can be seen from the FSC curves in Figure 3, where the red curve representing cryoDRGN-AI is always at or above the blue curve representing CryoSD. Additionally, quantitative metrics, such as FSC or FSC-AUC, are not reported, which would allow a quantitative comparison against competing methods that were not benchmarked in this paper but were benchmarked in other papers, such as cryoDRGN 2 (benchmarked in the CryoBench paper). \n\nOn the synthetic capsidHA dataset, the comparison to cryoDRGN-AI is unfair. CryoDRGN-AI assumes Gaussian white noise and could easily be adapted to handle the case of colored noise, for example by whitening the input data. CryoSD should be compared against a cryoDRGN-AI model that is adapted to colored, for example by whitening or changing the likelihood as was done for CryoSD, so we can assess how score distillation compares without the colored noise confound. \n\nOn EMPIAR-10295, I don’t think it’s fair to compare CryoSD against the result of a RELION ab initio job. A RELION ab initio job is just the initial stage of the RELION pipeline, so the results should be compared against the whole RELION pipeline, not its first stage. Second, both RELION and cryoDRGN-AI were only run on their default settings. Given that the input images represent large cages, I think it makes sense at a minimum to tune RELION’s mask diameter parameter and cryoDRGN-AI’s frequency marching parameters. Even better would be a more thorough attempt to tune the baselines on this dataset, perhaps as a grid search over each method’s most important hyperparameters. This is also possibly relevant for the capsidHA dataset as well. Additionally, it’s my experience that several runs of an ab initio algorithm may be needed to get one that converges, so multiple runs should be carried out for cryoDRGN-AI.\n\n**(W3) Missing comparisons**: I believe that the paper should compare their diffusion model-based denoising to other denoisers, with one motivation being to establish whether the gap in performance with cryoDRGN-AI on IgG-1D and IgG-RL is due to poor denoising.","questions_for_authors": "1. Can the authors explain how they get a denoising model with no access to clean groundtruth images?\n2. Can the authors explain how the anchors work? \n3. Can the authors explain where the score distillation part actually gets used?\n4. What are the quantitative metrics(FSC, per-image FSC-AUC) for CryoSD and cryoDRGN-AI in the IgG-1D and IgG-RL experiments? What are the FSC metrics for CryoSD and the baselines in the capsidHA and EMPIAR-10295?\n5. How does a cryoDRGN-AI model that is adapted for colored noise (either by whitening or changing the likelihood) compare to CryoSD in the capsidHA dataset?\n6. How does a tuned full RELION pipeline compare to CryoSD on EMPIAR-10295?\n7. How does a tuned cryoDRGN-AI model compare to CryoSD on EMPIAR-10295?\n8. How sensitive is CryoSD to scale $\\sigma$, which is estimated by visual inspection?\n9. How does the denoising model compare to other cryo-EM denoising methods?","flag_for_ethics_review": "No","rating": 1,"confidence": 4},"createdAt": "2026-10-21T04:34:18.923Z",- "modifiedAt": "2026-11-21T22:40:37.001Z",+ "modifiedAt": "2026-11-23T17:00:37.545Z","url": "https://openreview.net/forum?id=J878EJfVsr¬eId=8Tq497nEih","license": "CC-BY-4.0"}