potentialpaper

Prefix-Adaptive and Utility-Aware Stopping for EEG Closed-Loop Resource-Efficient Sleep Staging

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:01 UTC · 36e2e54ce62d ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "q51pe701g5"
- }
- ],
- "title": "Prefix-Adaptive and Utility-Aware Stopping for EEG Closed-Loop Resource-Efficient Sleep Staging",
- "authors": [],
- "abstract": "Continuous EEG acquisition dominates the resource budget of wearable sleep staging. Efficiency-oriented models fully observe a time period for decision, which is difficult to apply to resource-constrained actual deployment systems. Early time-series classification (ECTS) would stop once the observed prefix is decisive, but its instance-wise formulation assumes a stopping decision affects only the instance that made it. However, consecutive epochs are dependent, so stopping early truncates the history later epochs rely on, and a model trained on complete histories meets policy-induced covariate shift at inference. We introduce Prefix-Adaptive and Utility-Aware Stopping (PAUSE), a closed-loop framework in which each stopping decision controls both the current acquisition and the memory passed forward. A utility-aware finite-horizon stopper weighs stopping risk against expected continuation risk plus acquisition cost, a causal endpoint-memory backbone conditions each epoch on summaries taken at the policy-determined stopping points of its predecessors, and paired-history training combines complete and randomly truncated histories to reduce sensitivity to policy-induced history truncation. On four public datasets validation, PAUSE raises the macro-F1 versus acquisition frontier by 11.4 to 13.7 points over state-of-the-art ECTS baselines with 5.5 to 7.4 times less EEG. These results demonstrate the effectiveness of PAUSE for evidence-driven EEG acquisition in resource-constrained sleep monitoring.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "5128af6c-28fd-487f-be73-4b7105fc2ac9"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "Prefix-Adaptive and Utility-Aware Stopping for EEG Closed-Loop Resource-Efficient Sleep Staging",
+ "authors": [],
+ "abstract": "Continuous EEG acquisition dominates the resource budget of wearable sleep staging. Efficiency-oriented models fully observe a time period for decision, which is difficult to apply to resource-constrained actual deployment systems. Early time-series classification (ECTS) would stop once the observed prefix is decisive, but its instance-wise formulation assumes a stopping decision affects only the instance that made it. However, consecutive epochs are dependent, so stopping early truncates the history later epochs rely on, and a model trained on complete histories meets policy-induced covariate shift at inference. We introduce Prefix-Adaptive and Utility-Aware Stopping (PAUSE), a closed-loop framework in which each stopping decision controls both the current acquisition and the memory passed forward. A utility-aware finite-horizon stopper weighs stopping risk against expected continuation risk plus acquisition cost, a causal endpoint-memory backbone conditions each epoch on summaries taken at the policy-determined stopping points of its predecessors, and paired-history training combines complete and randomly truncated histories to reduce sensitivity to policy-induced history truncation. On four public datasets validation, PAUSE raises the macro-F1 versus acquisition frontier by 11.4 to 13.7 points over state-of-the-art ECTS baselines with 5.5 to 7.4 times less EEG. These results demonstrate the effectiveness of PAUSE for evidence-driven EEG acquisition in resource-constrained sleep monitoring.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}